• Title/Summary/Keyword: Air and water environment

Search Result 1,162, Processing Time 0.03 seconds

A Study on the Evaluation and Characteristics of Architectural Facility-equipment Noise in Building (건축 설비기기 소음의 특성 및 평가에 관한 연구)

  • Byun, Woon-Seob;Choi, Dool;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.537-544
    • /
    • 2009
  • On account of the technological development, intelligent building is on increasing where the artificial regulation on indoor environment is possible, thence the concern about those facilities such as water-supply facility, water-heater and drainage facility has becomes higher. However, due to diversification and complicated system of the facility-equipments, the noise generating from such facility equipment is gradually becoming a problem, and since especially equipment noises arising at the machine room frequently infringe into the resident's pleasant living environment with the complex types of an air-borne sound and a structure-borne sound, it is becoming the civil complaint. On such viewpoint, this Study ever observed the characteristics of noise generating from various facility-equipments in the building, and intended to evaluate the facility-noises by use of the valuation index such as PSIL, N, NC, NR. As result of, the facilities noise which happens in the machine room makes normal conversation very difficult due to high sound pressure level. Based on such data, this study is willing to present it as an essential material for establishment an efficient measure against the facility-noises arising at machine room hereafter.

Estimation of the thermal performance on the double slab floor with supplying air (급기가 되는 이중바닥 구조체의 열 성능 평가)

  • Cha, Kwang-Seok;Park, Myung-Sig;Lee, Dae-Woo;Nam, Woo-Dong
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.866-871
    • /
    • 2006
  • Recently according to the fashion of well-being, the case study of under floor heating system type for residential space is increasing. Specially double slab floor system can make several roles as reducing the acoustic noises and also supplying fresh air through the gap. So in present study floor heating performance was examined with various location of the space in the case of floor supply air and ceiling supply air. In both cases return air went out through ceiling opening. As one of the result is that when using the heat pipe type floor heating system the temperature difference between supply and return water was $15.2^{\circ}C$, but in case of commercial type floor heating system the temperature difference was $5.3^{\circ}C$ when the supply water temperature was $50^{\circ}C$.

  • PDF

Design Capacity Evaluation of 2-stage Hot Water Heat Exchanger in Apartment Mechanical Rooms with District Heating System (지역난방 공동주택에 설치하는 급탕 2단 열교환기의 용량 적정성 평가에 관한 연구)

  • Chung, Kwang-Seop;Sa, Ki-Yong;Kim, Lae-Hyun;Lee, Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.8
    • /
    • pp.456-461
    • /
    • 2009
  • Recently, an increasing interest in district heating system has emerged rapidly, In this paper, the physical measurements and data to be monitoring through the internet were carried out with regard to hot water heating energy consumption at the three apartment housings with district heating system in Sang-am district of Seoul, Korea, Measurements were made of the thermal factors such as the pressure of heating pipe, flow rates, hot water temperature and etc, The objective of this study is to compare the design capacity of reheat exchanger with that of preheat exchanger in order to evaluate for the number of plates of two exchangers to be distributed properly.

Freezing of Micro-size Water Droplet on Micro Porous Surface (박판형 미세다공 표면에서의 미소액적의 동결)

  • Park, Chun-Wan;Lee, Dong-Gyu;Peck, Jong-Hyeon;Kang, Chae-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.3
    • /
    • pp.173-178
    • /
    • 2011
  • Gas diffusion layer(GDL) in PEMFC performs the discharge of water vapor smoothly. When GDL is revealed to cold environment, the freezing of the water droplet or water net in GDL occurs. The purpose of this work is to observe the cooling and freezing behavior of the water droplet which meets to the microporous surface and air under the various low temperature conditions. GDL was coated with waterproof material, which has three types of coating rate, 0, 40 and 60%. Water droplets in series of sizes on GDL were supercooled, frozen and crystalized orderly by circulating low temperature brine. The process of cooling was investigated with the temperature and the snapshot of the water droplet.

Effect of Sludge Characteristics on the Thickening of Bulking Sludge using DAF (Dissolved Air Flotation) (슬러지의 성상이 DAF(Dissolved Air Flotation)를 이용한 팽화 슬러지 농축에 미치는 영향)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.97-103
    • /
    • 2006
  • Excess sludge treatment and disposal currently represent a rising challenge for domestic or wastewater treatment plants due to economic, environmental and regulation factors. Conventional gravity sedimentation process has been widely used in sludge thickening. The operation method of the process is very simple, but the process requires long detention time for sludge thickening, uses polymers, and shows low sludge thickening efficiency. To solve the problems, we studied on DAF (Dissolved Air Flotation) system. We use bulking sludge of a paper manufacturing plant. The effects of parameters such as SVI (Sludge Volume Index), storage time, initial concentration and wet density of excess sludge were examined. The results showed that the more SVI was low, the more sludge was thickened. As storage time goes by, SVI was increased and thickening performance was deteriorated. In order to improve flotation performance at high concentration, high recycling ratio and pressure did not increase the concentration due to thickening limitation. The addition of 0.8 g/L of loess was increased flotation efficiency of 1.41 times.

A Study on Water Quality Standard for the Protection of Human Health and Aquatic Life (인체의 위해성과 수생태계를 고려한 수질환경기준 설정에 관한 연구)

  • Lee, Jae-Hyun;Kim, Yoon-Shin
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.985-992
    • /
    • 2007
  • There are about 40,000 chemicals used in Korea and 300 new types of chemicals are added to the list every year, influencing quality of air, soil and water. Water quality standards that serve as the basis for water quality management have been proved inefficient and insufficient compared to those of advanced countries. This study aims to improve the existing water quality standards. Most importantly, the water quality standards need to take into account not only protection of human health but also aquatic resources. To that end, water quality criteria need to be set by monitoring each watershed every year and conducting risk assessment. Criteria for human health are set at $10^{-6}$ cancer risk level, and for aquatic life at conservative level, adopting the methodology of the U.S. and Australia, respectively. After carrying out technical and economic feasibility studies, more conservative criteria will be used to decide final water quality standards. The development of this system to establish integrated water quality standards for both human health and aquatic resources protection is urgently needed.

Analysis of Water-quality Improvement Efficiency of Constructed Wetland Using NPS-WET Model (NPS-WET 모형을 이용한 인공습지의 수질정화효과 분석)

  • Rhee, Han-Pil;Jung, Kwang-Wook;Lee, Bok-Soo;Ham, Jong-Hwa;Son, Yeong-Kwon
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.320-331
    • /
    • 2012
  • A combination system of catch canal and constructed wetland was designed and suggested to improve water quality in gagricultural region of lower Dong-jin river basin. In order to evaluate an water quality improvement efficiency of the designed combination system, the NPS-WET model was applied in this study. Simulation result of the NPS-WET shown that the nutrient load removal rate of constructed wetland was BOD, T-N, T-P and SS was 30.7~39.0%, 46~60%, 40.7~57.0% and 68.2~74.7%, respectively. Nutrients reduction of constructed wetland was higher in growing season than winter season because vital activity of microorganism, macrophyte and algae was augmented with high air and water temperature. Effluents from constructed wetland can affect water-quality of catch canal drains, especially, water-quality on junction point to Dong-jin river. Water-quality improvement in low-flowed catch canal (Un-san) was more significant than in high-flowed catch canal (Won-pyeong). In conclusion, a feasible design of constructed wetland is necessary to treat large quantity of receiving water. The NPS-WET is useful tool for assessing water-quality improvement efficiency using constructed wetland.

Ammonia Nitrogen Removal in Wastewater Using Microwave Irradiation (마이크로웨이브를 이용한 폐수 내 고농도 암모니아성질소 제거)

  • Shin, Soyeun;Koo, Bonheung;Kim, Taehyun;Lee, Yuhak;Ahn, Johng-Hwa
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.5
    • /
    • pp.486-490
    • /
    • 2014
  • Industrial use of microwave heating as an alternative to conventional heating is becoming popular mainly due to dramatic reductions in reaction time. Therefore, this work experimentally determined the effect of microwave irradiation on ammonia nitrogen removal in wastewater. The effects of air flow rate (0.3~0.9 L/min), treatment temperature ($70{\sim}100^{\circ}C$), and initial pH (9~11) were characterized. As the air flow rate increased from 0.3 to 0.9 L/min, the ammonia removal rate constant (k) increased from -0.6642 to $-1.0755min^{-1}$. As the temperature increased from 70 to $100^{\circ}C$, k increased -0.0338 to $-1.0755min^{-1}$. As the pH increased from 9 to 11, k increased -0.2443 to $-1.0755min^{-1}$. Ammonia removal was strongly dependent on temperature and pH rather than air flow rate. The results show that microwave irradiation is effective in ammonia nitrogen removal in wastewater due to advantages of fast and effective processing.

Precision Control of Water Bath Temperature using Air Cooled Variable Refrigerant Flow Chiller (공랭식 변유량 냉매 냉동기를 적용한 수조 온도의 정밀 제어)

  • Jeong, Kwang-Ju;Kim, Young Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.27-34
    • /
    • 2018
  • This study compared constant water bath performances of conventional water-cooled refrigerator and electric heater with an air-cooled VRF chiller and electric heater equipped with optimal control algorithm. In heating mode, the air cooled VRF chiller and electric heater combination reduced the set temperature arrival time by an average of 42 minutes, and energy was also reduced by 18%. In cooling mode, the two systems took 70 minutes to reach the set temperature and showed no difference. Energy was reduced by 33.5% with the new system. For constant temperature maintaining experiment, after reaching the set temperature of $15^{\circ}C$, $20^{\circ}C$ and $22^{\circ}C$, temperature deviations were all in the range of $-0.2^{\circ}C$ to $+0.1^{\circ}C$. Energy was reduced by an average of 84.9%. Through this study, possibility of precise temperature control by an air cooled VRF chiller system was confirmed.

Physical, Chemical and Optical Properties of Fine Aerosol as a Function of Relative Humidity at Gosan, Korea during ABC-EAREX 2005

  • Moon, Kwang-Joo;Han, Jin-Seok;Cho, Seog-Yeon
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.3
    • /
    • pp.129-138
    • /
    • 2013
  • The water uptake by fine aerosol in the atmosphere has been investigated at Gosan, Korea during ABC-EAREX 2005. The concentration of inorganic ion and carbon components, size distribution, and light scattering coefficients in normal and dry conditions were simultaneously measured for $PM_{2.5}$ by using a parallel integrated monitoring system. The result of this study shows that ambient fine particles collected at Gosan were dominated by water-soluble ionic species (35%) and carbonaceous materials (18%). In addition, it shows the large growth of aerosol in the droplet mode when RH is higher than 70%. Size distribution of the particulate surface area in a wider size range ($0.07-17{\mu}m$) shows that the elevation of RH make ambient aerosol grow to be the droplet mode one around $0.6{\mu}m$ or the coarse mode one, larger than $2.5{\mu}m$. Hygroscopic factor data calculated from the ratio of aerosol scattering coefficients at a given ambient RH and a reference RH (25%) show that water uptake began at the intermediate RH range, from 40% to 60%, with the average hygroscopic factor of 1.10 for 40% RH, 1.11 for 50% RH, and 1.17 for 60% RH, respectively. Finally, average chemical composition and the corresponding growth curves were analyzed in order to investigate the relationship between carbonaceous material fraction and hygroscopicity. As a result, the aerosol growth curve shows that inorganic salts such as sulphate and nitrate as well as carbonaceous materials including OC largely contribute to the aerosol water uptake.