• Title/Summary/Keyword: Air accident

Search Result 397, Processing Time 0.025 seconds

Study of hydrodynamics and iodine removal by self-priming venturi scrubber

  • Jawaria Ahad;Talha Rizwan ;Amjad Farooq ;Khalid Waheed ;Masroor Ahmad ;Kamran Rasheed Qureshi ;Waseem Siddique ;Naseem Irfan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.169-179
    • /
    • 2023
  • Filtered containment system is a passive safety system that controls the over-pressurization of containment in case of a design-based accidents by venting high pressure gaseous mixture, consisting of air, steam and radioactive particulate and gases like iodine, via a scrubbing system. An indigenous lab scale facility was developed for research on iodine removal by venturi scrubber by simulating the accidental scenario. A mixture of 0.2 % sodium thiosulphate and 0.5 % sodium hydroxide, was used in scrubbing column. A modified mathematical model was presented for iodine removal in venturi scrubber. Improvement in model was made by addition of important parameters like jet penetration length, bubble rise velocity and gas holdup which were not considered previously. Experiments were performed by varying hydrodynamic parameters like liquid level height and gas flow rates to see their effect on removal efficiency of iodine. Gas holdup was also measured for various liquid level heights and gas flowrates. Removal efficiency increased with increase in liquid level height and gas flowrate up to an optimum point beyond that efficiency was decreased. Experimental results of removal efficiency were compared with the predicted results, and they were found to be in good agreement. Maximum removal efficiency of 99.8% was obtained.

Transient Stability Analysis of Vessel Power System Using Alternative Marine Power (육상전원공급장치(AMP) 이용한 선내 전원 공급 시 계통 안정도 분석)

  • Seung-pyo Kang;Jang-mok Kim;Hyun-jun Cho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.2
    • /
    • pp.215-222
    • /
    • 2023
  • Alternative marine power (AMP) is continuously used in ports and on docks because of regulations on global ship emission reduction. In Korea, the use of AMP is also mandatory under the Special Act on Port Air Quality Improvement, and efforts are under way in connection with various eco-friendly ships, such as electric-propulsion ships. In this study, AC load flow analysis was performed by modeling the situation in which onboard power is supplied through AMP. This analysis made it possible to study the electrical parameters and losses when power was supplied to the ship. In addition, through a transient stability analysis, the high-speed generation transfer limit value for uninterruptible conversion through onboard generators in the event of a system accident was derived. The results obtained when it was applied are presented

A study on Preventive Measures for Fire and Explosion Accidents During Acetic Acid Handling in Manufacturing the Semiconductor Material (반도체 소재 제조 공정에서 아세트산 취급 작업 시 발생한 화재·폭발 사고 예방대책에 관한 연구)

  • Dae Joon Lee;Sang Ryung Kim;Sang Gil Kim;Kyo Shik Park;Joon Won Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.65-70
    • /
    • 2023
  • Flammable materials used in semiconductor supply facilities are manufactured at high temperatures and high pressures, and as the semiconductor industry becomes more sophisticated and larger, the amount of materials used is rapidly increasing. Recently, fires and explosions occurred during the handling of acetic acid, which is a raw material for making products in the semiconductor material manufacturing process. Overall problems such as lack of air inflow prevention for fire and explosion prevention were identified. Therefore, in this study, in order to accurately identify the cause of the accident and prevent fire and explosion that may occur in the process of handling large amounts of flammable liquids, opinions from various perspectives, such as construction of facilities such as hoppers, installation of AOPS components, and change in workers' perceptions would like to present.

Study on the Methods of Detection and Analysis for Responding Inorganic Acids Spill (무기산 누출 사고 대응을 위한 탐지·분석 방법 연구)

  • Lee, Jin Seon;Jung, Mi Suk;Kim, Ki Joon;Ahn, Sung Young;Yoon, Young Sam;Yoon, Junheon
    • Korean Journal of Hazardous Materials
    • /
    • v.2 no.1
    • /
    • pp.6-11
    • /
    • 2014
  • There have been frequent chemical leaks over the past 10 years. Particularly, inorganic acids like sulfuric acid, nitric acid, and hydrogen chloride take up 37 % of the total chemical accidents which took place for the past 10 years. When an acid chemical leak happens, fume is generated, diffusing into the air, which might cause serious damage to health of local residents and the environment. However, most of the acid-based chemicals, detecting and analysis methods have not been settled considering the frequency of accidents. In this study, we investigated detection and analysis methods to quickly analyze accident sites and evaluate the impacts on environments. Reviewing local and international test analysis methods of acids suggested that nitric acid, sulfuric acid, hydrogen chloride and hydrogen fluoride can be analyzed with IC. It was also found that UV is better for the analysis of hydrogen fluoride and GC/MS for acrylic acid. The analytical methods suggested in the official test methods basically have limitations of consuming much time at stages of preparation and analysis. Considering prompt responses to chemical accidents, further studies should be done to compare the applicability of rapid monitoring methods such as FT-IR, IMR-MS and SIFT-MS.

Analysis of Internal Overpressure by Pipe Cross-Sectional Area Ratio and Filling Rate in the Hydraulic Test of Shipboard Tank (수압시험 시 관 단면적 비 및 충수 속도별 탱크 내부 과압 발생에 관한 해석)

  • Geun-Gon Kim;Tak-Kee Lee
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.6
    • /
    • pp.460-472
    • /
    • 2023
  • This study was conducted based on the case of an accident (excessive deformation) that occurred during the hydraulic test of a shipboard tank manufactured in accordance with the design regulations. Over-pressure phenomenon was noted as the main cause of accidents in the process of testing tanks without physical damage, which can be found in external factors such as cross-sectional difference between inlet pipe and air pipe and higher water filling rate than the recommended one. The main goal of this paper is to establish a safe water filling rate according to the range of sectional area ratio(SAR) reduced below the regulations for each test situation. The simulation was conducted in accordance with the hydraulic test procedure specified in the Ship Safety Act, and the main situation was divided into two types: filling the tank with water and increasing the water head to the test pressure. The structural safety evaluation of the pressure generated inside the tank and the effect on the structure during the test was reviewed according to the SAR range. Based on the results, guidelines for the optimal filling rate applicable according to SAR during the hydraulic test were presented for the shipboard tanks used in this study.

Ventilation Performance Study on Hydrogen Leakage Characteristics of Container Packaged Water Electrolysis Production System (컨테이너 패키지형 그린수소 수전해 생산 시스템의 수소 누출 특성에 관한 환기 성능 연구)

  • SOOIN KWON;BYUNGSEOK JIN;CHEEWOO LEE;SEONGYONG EOM;GYUNGMIN CHOI
    • Journal of Hydrogen and New Energy
    • /
    • v.35 no.3
    • /
    • pp.324-335
    • /
    • 2024
  • The container package type sealed water electrolysis production system installs mechanical balance of plant and electrical balance of plant as an integrated unit to enable independent operation within the package module. The auxiliary equipment required to operate the water electrolysis system must be integrated to reduce the installation area and shorten the installation time. At this time, as leak risk factors are placed in a dense space, when a hydrogen gas leak accident occurs, it can have a mutual influence on other adjacent facilities, so it contains various risk factors. In this study, when a gas leak occurs in a container packaged water electrolysis system, possible sources of leakage in the system according to the KS C IEC 60079-10-1:2015 and KGS GC101 standards were identified, and the leak rate and leak characteristics were calculated. did. The hazardous area and its range were calculated according to ventilation and dilution characteristics. In order to optimize ventilation characteristics, design of experiment was used to analyze the influence to evaluate the adequacy of ventilation, and overseas ventilation standards were analyzed and compared. In addition, the optimal ventilation structure and characteristics of the container packaged water electrolysis system were presented according to the results of the experimental design method.

A Study of the "erlaubtes Risiko" in Aviation (항공 운항에서의 허용된 위험 법리에 대한 연구)

  • Ham, Se-Hoon
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.25 no.2
    • /
    • pp.201-230
    • /
    • 2010
  • With starting the industry of automobiles, railroads and mining, the legal principle of "erlaubtes Risiko" that began as a means of maintaining the revitalized world for the cause of social utility has interpreted as a system of negligence theory in the precedent while it has gained academic recognition. Yet in aircraft operation, which is one area of high technology, CAT which can be the cause of some accidents or events or thunderstorm with turbulence is an abnormal meteorological phenomenon with frequent change that cannot be monitored perfectly just as some patient with unstable condition and that cannot be ascertained about not only the possibility of its happening but also the degree of how big the accident is. Yet the use of jet current which has the possibility of CAT can be an act of high social utility where we not only drastically cut down on time fuel also guarantee the arrival and departure on schedule when landing in airports that have thunderstorm which does not appear as fatal risk. Although we could take some measures where we can predict and avoid the potential risk, easing the regular duty of care is necessary by applying the legal principles of permitted risk concerning the incidents and accidents caused by operating in areas with the risk of turbulence or CAT with the low probability by the reason of social utility.

  • PDF

Study on Improvement for selecting the optimum voice channels in the radio voice communication (무전기 음성통신에서 최적음성채널 선택을 위한 개선방안에 관한 연구)

  • Lew, Chang-Guk;Lee, Bae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.2
    • /
    • pp.171-178
    • /
    • 2016
  • An aircraft in flight and ATC(: Air Traffic Controllers) working in the Ground Control Center carry out a voice communication using the radio. Voice signal to be transmitted from the aircraft is received to a plurality of terrestrial sites around the country at the same time. The ATC receives the various quality of voice signal from the aircraft depending on the distance, speed, weather conditions and adjusted condition of the antenna and the radio. The ATC carries out a voice communication with aircraft in the optimal conditions finding the best voice signal. However, the present system chooses the values of the CD(: Carrier Dectect) which is determined to be superior to, based on the input voice level, as optimal channel. Thus this system can not be seen to select the optimal channel because it doesn't consider the effect of the noise which influences on the communication quality. In this paper, after removing the noise in the voice signal, we could give the digitized information and an improved voice signal quality, so that users can select an optimal channel. By using it, when operating the training eavesdropping system or the aircraft control, we can expect prevention accident and improvement of training performance by selecting the improved quality channel.

3D Visualization Techniques for Volcanic Ash Dispersion Prediction Results (화산재 확산 예측결과의 삼차원 가시화 기법)

  • Youn, Jun Hee;Kim, Ho Woong;Kim, Sang Min;Kim, Tae Hoon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.1
    • /
    • pp.99-107
    • /
    • 2016
  • Korea has been known as volcanic disaster free area. However, recent surveying result shows that Baekdu mountain located in northernmost in the Korean peninsula is not a dormant volcano anymore. When Baekdu mountain is erupting, various damages due to the volcanic ash are expected in South Korea area. Especially, volcanic ash in the air may cause big aviation accident because it can hurt engine or gauges in the airplane. Therefore, it is a crucial issue to interrupt airplane navigation, whose route is overlapped with volcanic ash, after predicting three dimensional dispersion of volcanic ash. In this paper, we deals with 3D visualization techniques for volcanic ash dispersion prediction results. First, we introduce the data acquisition of the volcanic ash dispersion prediction. Dispersion prediction data is obtained from Fall3D model, which is volcanic ash dispersion simulation program. Next, three 3D visualization techniques for volcanic ash dispersion prediction are proposed. Firstly proposed technique is so called 'Cube in the Air', which locates the semitransparent cubes having different color depends on its particle concentration. Second technique is a 'Cube in the Cube' which divide the cube in proportion to particle concentration and locates the small cubes. Last technique is 'Semitransparent Volcanic Ash Plane', which laminates the layer, whose grids present the particle concentration, and apply the semitransparent effect. Based on the proposed techniques, the user could 3D visualize the volcanic ash dispersion prediction results upon his own purposes.

Numerical Study on Characteristics of Gas Leakage in an Underground Combined Cycle Power Plant (지하 복합발전 플랜트 내부의 가스 누출 특성에 대한 수치해석 연구)

  • Bang, Joo Won;Sung, Kun Hyuk;Ryou, Hong Sun;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.594-600
    • /
    • 2016
  • The present study numerically investigated the gas leakage characteristics in a simplified underground combined cycle power plant. The effect of obstacles near a crack location on the gas concentration in the confined space was analyzed by using the lower flammable limit (LFL) of methane gas. When the jet flow was close to the vertical walls, the longitudinal leakage distance increased by about 60% (when an obstacles was present) compared to the case without any obstacle, because these obstacles prevented transverse flows. In addition, when an air filter was installed near to the trajectory of the gas flow, the longitudinal leakage distance was similar to the distance between the crack and obstacle, whereas the transverse leakage distance increased up to 8 times compared to the case without any obstacle. As the jet flow impacts on the obstacle and changes its direction, the gas flows recirculate. Therefore, it is necessary to consider the effect of the structure and facility locations on the trajectory of the jet flow to propose an accident prevention system in confined spaces.