• Title/Summary/Keyword: Air Volume Change

Search Result 272, Processing Time 0.028 seconds

Comparative Analysis of the Optical Aging Patterns in Different Partitions of the Beeswax-Treated Volume during Dry Heating Aging at $105^{\circ}C$ (건식 인공열화 시 밀랍본 시제품의 제본부위별 광학적 특성변화 비교분석)

  • Choi, Kyoung-Hwa;Jeong, Hye-Young;Kang, Yeong-Seok;Cho, Jung-Hye
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.43 no.3
    • /
    • pp.98-105
    • /
    • 2011
  • Patterns and levels of aging vary between the book volume and sheets, even though both are made from the same paper materials. In case of book format, the outside is more easily affected than inner side by environmental factors such as temperature, humidity and air. In this study, the change in optical properties after dry heating accelerated aging was comparatively analyzed to understand the difference of the optical aging characteristics between outside and inner side of the duplicated beeswax-treated volume. It is found that the cover pages of the beeswax-treated volumes were more optically deteriorated than their middle pages. This indicates that outer sides of aging book volume directly exposed to the air is more vulnerable to serious deterioration than inner sides. Also, aromatic compounds such as benzoic acid and cinnamic acid were observed in the investigation of UV/VIS absorbance of the beeswax in each aged sample.

Impacts of Three-dimensional Land Cover on Urban Air Temperatures (도시기온에 작용하는 입체적 토지피복의 영향)

  • Jo, Hyun-Kil;Ahn, Tae-Won
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.3
    • /
    • pp.54-60
    • /
    • 2009
  • The purpose of this study is to analyze the impacts of three-dimensional land cover on changing urban air temperatures and to explore some strategies of urban landscaping towards mitigation of heat build-up. This study located study spaces within a diameter of 300m around 24 Automatic Weather Stations(AWS) in Seoul, and collected data of diverse variables which could affect summer energy budgets and air temperatures. The study also selected reflecting study objectives 6 smaller-scale spaces with a diameter of 30m in Chuncheon, and measured summer air temperatures and three-dimensional land cover to compare their relationships with results from Seoul's AWS. Linear regression models derived from data of Seoul's AWS revealed that vegetation volume, greenspace area, building volume, building area, population density, and pavement area contributed to a statistically significant change in summer air temperatures. Of these variables, vegetation and building volume indicated the highest accountability for total variability of changes in the air temperatures. Multiple regression models derived from combinations of the significant variables also showed that both vegetation and building volume generated a model with the best fitness. Based on this multiple regression model, a 10% increase of vegetation volume decreased the air temperatures by approximately 0.14%, while a 10% increase of building volume raised them by 0.26%. Relationships between Chuncheon's summer air temperatures and land cover distribution for the smaller-scale spaces also disclosed that the air temperatures were negatively correlated to vegetation volume and greenspace area, while they were positively correlated to hardscape area. Similarly to the case of Seoul's AWS, the air temperatures for the smaller-scale spaces decreased by 0.32% ($0.08^{\circ}C$) as vegetation volume increased by 10%, based on the most appropriate linear model. Thus, urban landscaping for the reduction of summer air temperatures requires strategies to improve vegetation volume and simultaneously to decrease building volume. For Seoul's AWS, the impact of building volume on changing the air temperatures was about 2 times greater than that of vegetation volume. Wall and rooftop greening for shading and evapotranspiration is suggested to control atmospheric heating by three-dimensional building surfaces, enlarging vegetation volume through multilayered plantings on soil surfaces.

Thermal Performance of Air receiver with a Change of Flow direction for Dish Solar Collector (공기식 흡수기의 유동 방향에 따른 $5kW_t$급 접시형 태양열 집열기의 열성능 분석)

  • Seo, Joo-Hyun;Kang, Kyung-Moon;Lee, Ju-Han;Oh, Sang-June;Seo, Tae-Beom
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.182-185
    • /
    • 2008
  • The thermal performance of air receiver with a change of flow direction for dish solar collector. This system is installed and operated in Incheon, Korea. The thermal capacity of the system is about 5 kW thermal. The aperture diameter of the cylindrical-shape receiver which is made of stainless steel is 100 mm, and the height is 210 mm. Experiments are being carried out to investigate the thermal performance variation of the receivers with several design parameters such as the shape of the receiver, the flow directions and the flow rate of air. First, air flows into the upper part of the receiver, which is the opposite side of the aperture. After the air flows through the inside receiver, that goes out of the receiver through 3 exits which are located near the aperture. Second, air flows into the backside of the receiver, Which is the forward side of the aperture. After the air flows through the inside receiver, that goes out of the receiver through 1 exit. The results show that the system efficiency and receiver efficiency increase as the volume flow rate increases as expected.

  • PDF

Wearable wireless respiratory monitoring system (의복착용형 무선 호흡모니터 시스템)

  • Lee, In-Kwang;Kim, Seong-Sik;Jang, Jong-Chan;Kim, Koon-Jin;Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.133-142
    • /
    • 2008
  • Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. The present study implemented wireless wearable respiratory monitoring system with the conductive rubber cord in the patient's pants. Signal extraction circuitry was developed to obtain the abdominal circumference changes reflecting the lung volume variation caused by respiratory activity. Wireless transmission was followed based on the zigbee communication protocol in a size of 65mm${\times}$105mm easily put in pocket. Successful wireless monitoring of respiration was performed in that breathing frequency was accurately estimated as well as different breathing patterns were easily recognized from the abdominal signal. $CO_2$ inhalation experiment was additionally performed in purpose of quantitative estimation of tidal volume. Air mixed with $0{\sim}5%\;CO_2$was inhaled by 4 normal males and the respiratory air flow rate, abdominal dimension change, and end tidal $CO_2$ concentration were simultaneously measured in steady state. $CO_2$ inhalation increased the tidal volume in normal physiological state with a correlation coefficient of 0.90 between the tidal volume and the end tidal $CO_2$ concentration. The tidal volume estimated from the abdominal signal linearly correlated with the accurate tidal volume measured by pneumotachometer with a correlation coefficient of 0.88 with mean relative error of approximately 8%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.

Ventilatory Responses to Continuous Negative Pressure Breathing(CNPB) in Awake Dogs

  • Cha, Eun-Jong;Goo, Yong-Sook
    • The Korean Journal of Physiology
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 1993
  • Ventilatory responses to inhaled $CO_2$ were measured during continuous negative pressure breathing (CNPB) in awake dogs. End expiratory lung volume (EELV) decreased linearly with pressure level during CNPB (correlation coefficient= 0.81, p<0.005) during air breathing. When CNPB was applied during 5% $CO_2$ inhalation, the decrease in EELV was not significantly different (p<0.5) from that during air breathing. As a result of a lowered EELV, tidal volume ($V_T$) significantly decreased by 22% and breathing frequency ($f_B$) increased by 68% in the steady state during air breathing (p<0.0001). These responses were similar during 5% $CO_2$ inhalation, thus the $CO_2$ response curve measured during CNPB shifted upward without a change in sensitivity (p>0.05). These results indicate additive effects of CNPB and $CO_2$ inhalation. The degree of hyperventilation during CNPB at eupnea was estimated to be 63% of that during control ventilation and was significantly greater than zero (p<0.0001), which suggests an alveolar hyperventilation due to CNPB. These results suggest that the mechanical alterations associated with n decrease in lung volume could play an important role in ventilatory control independently of chemical regulation of breathing. Thus, exercise hyperpnea, which is associated with a lowered functional residual capacity (FRC), may in part be explained by this mechanical stimulation of breathing.

  • PDF

Cavitation Characteristics of a Pump-turbine Model by CFD Analysis

  • Singh, Patrick Mark;Chen, Chengcheng;Chen, Zhenmu;Choi, Young-Do
    • The KSFM Journal of Fluid Machinery
    • /
    • v.18 no.4
    • /
    • pp.49-55
    • /
    • 2015
  • The pumped storage plant operates with quick change of the discharge as well as quick changes between pump mode and turbine mode. This study focuses on the cavitation analysis of a pump-turbine model because in turbo-machinery, cavitation can reduce the performance and shorten service life. The pump-turbine model system consists of 7 blades, 20 stay vanes (including tongue) and 20 guide vanes. This study adopts the Rayleigh-Plesset model as a cavitation model, which illustrates cavitation by using the air volume fraction method. The pump mode and turbine mode at the operating condition of partial loading, normal and excessive loading are analyzed to investigate the cavitation performance of the pump-turbine. It was observed that this pump-turbine design showed very good cavitation characteristics with no cavitation bubbles in all operating conditions. Overall value of air volume fraction of both mode at different operating condition are lower than 1, which confirms low possibility of cavitation occurrence at current situation.

A Study on Atomosphere Sintering to affect the Abnormal Expansion in Solid-Solid Reaction of $BaTiO_3$ (Barium Titanate를 고상반응으로 합성할 때 팽창에 영향을 주는 분위기조성에 관한 연구)

  • 이은상;임대영
    • Journal of the Korean Ceramic Society
    • /
    • v.23 no.4
    • /
    • pp.41-46
    • /
    • 1986
  • When barium titanate was synthesized in solid-solid reaction the abnormal expansion occurred from 90$0^{\circ}C$ to 110$0^{\circ}C$. The equi molecular mixture of $BaCo_3$ and $TiO_2$ was sintered from 90$0^{\circ}C$ to 130$0^{\circ}C$ on the condition of air vacuum and $CO_2$ atomosphere. After that the specimens were tested closely with XDR Dilatometer and SEM The result indicated that: 1, Volume expansion to be synthesized barium titanate in solid-solid reaction was affected by atomosphere sintering. 2. The solid reaction ot fiorm barium titanate in vacuum atomosphere occurred faster than that in air atomosphere. In vacuum atomosphere the maxium volume expansion was about 30% at 90$0^{\circ}C$ for 2hrs, 3. The solid reaction to form barium titanate in 4CO_2$ atomosphere occurred slower than that in air atomosphere. In $CO_2$ atomosphere the maximum volume expansion was 13% at 100$0^{\circ}C$ for 2 hrs. 4. According to the result of x-ray the expanison was caused by the reaction to form $BaTiO_3$ and change $Ba_2TiO_4$ into 4BaTiO_3$.

  • PDF

A Study on Humid Control Characteristics of Alkaline Desiccants (알칼리성 용해제의 조습특성에 관한 연구)

  • Hong, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.21 no.2
    • /
    • pp.169-173
    • /
    • 2010
  • Many salts have the ability to attract and remove water vapor from the surrounding environment. The ability of each salt to remove water vapor is based on the flow rate and temperature of air in surrounding. The objective of this study was toinvestigate the humid control characteristics in air-water system by using a desiccants. The aim is to asses the influence of three parameters on the humid control process which are air volume rate, air temperature and desiccant amount. Humidity control materials which consist of K (potassium) or Na (sodium) have been synthesized by the aqueous process. The humidity control properties of materials have been also investigated. Experiment results are as following. Thermal characteristics of desiccants showed similar properties regardless of processing condition. The experiments were examined by using artificial air-water system (humidity : 70~93%, air volume rate : $0.22{\sim}0.69m^3/s$). The results showed that the Na-type desiccant was an effective material. It was found that dew point increased with air volume rate, and the humidity change in humid control process was depended on desiccants amount.

Studies on the Total Suspended Particulates in Iksan City. (익산시의 부유먼지에 관한 연구)

  • 전병영
    • Journal of environmental and Sanitary engineering
    • /
    • v.14 no.4
    • /
    • pp.158-164
    • /
    • 1999
  • This study was carried out to investigate total suspended particulates (TSP) in Iksan area collected by nine stages Anderson air sampler and High volume air sampler from Jul. 1996 to Jul. 1998.The results are as follows1. The average of TSP concentration to be collected by Anderson air sampler and High volume air sampler in Iksan city are $59{\mu}g/m^3$, $67{\mu}g/m^3$. It was below the level of environmental standard. 2. The average of TSP concentration by measured method are HVAS > AS > Gov. 3. The average of TSP concentration on seasonal change are higher spring than winter. It were $65.5{\mu}g/m^3$ of Spring, $57{\mu}g/m^3$ of Summer, $52.5{\mu}g/m^3$ of Fall, $61{\mu}g/m^3$ of Winter. 4. Particle size 3istribution of atmospheric particulate was divided into two groups, coarse group was made by particles larger than $1.1-2.1{\mu}m$ in diameter and fine groups smaller than $1.1-2.1{\mu}m$ in diameter. about 50% of total suspended particle measured by Anderson air sampler during the sampling period was coarse particle.

  • PDF

An Experimental Study on the Water Repellent Property of Mortar Applied Water Repellent Agent of Inorganic Polymer Type (무기질 폴리머계 흡수방지재를 도포한 모르터의 발수성능 평가에 관한 실험적 연구)

  • 김영삼;양승도;유재강;오상근
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2002.05a
    • /
    • pp.31-36
    • /
    • 2002
  • Recently, more interests in surface treatment of structure with water repellent agent are steadily increased, But, investigation of its properties such as protection, durability, morphology of micro structure is not sufficient. Therefore, This paper is aimed for the investigation of water repellent property and change of morphology of micro pores in mortar that is treated by water repellent agent(Inorganic polymer based material). Water repellent property, water absorption coefficient, air permeability, porosity and the observation of micro structure was investigated in different water repellent agent type. The test results indicated that water repellent treated mortar showed low absorption coefficient and air permeability(breathing effect). This is why inorganic polymer is coated at the wall of capillary and micro pores, also, the volume of micro pore is reduced without the change of morphology in micro structure.

  • PDF