A study on Development and Application of Sequential Control Algorithm of Ventilation and Air Cleaning System for Improving Indoor Air Quality in School Classroom (학교교실의 실내공기질 개선을 위한 환기장치 및 공기청정기의 연동제어 알고리즘 개발 및 적용 연구)

  • Park, Hwan-Chul;Lee, Dong-Hyeon;Yee, Jurng-Jae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.5
    • /
    • pp.187-194
    • /
    • 2020
  • This study presents the energy-saving sequential control algorithm to handle indoor CO2 and PM2.5 for the improvement of the air quality of school classrooms. To solve indoor air quality (IAQ) problems, air cleaning and ventilation systems are mainly used for school classrooms. Although air cleaning is able to collect PM2.5, it is difficult to remove harmful gas substances. The ventilation system is suitable to tackle CO and CO2, the volume ventilation, however, is relatively small. In this paper, to remove CO2 and PM2.5, the pollutant balance equation for improving indoor air quality is reviewed. The sequential control algorithm of the ventilation and air cleaning system with four levels of criteria is introduced for the effective removal of pollutants. The proposed sequential control algorithm confirms that indoor CO2 and PM2.5 can be properly controlled below the standard value. In addition, the sequential operation of air cleaning and ventilation systems has shown significant improvement in IAQ compared to the independent ventilation system operation. Particularly, such systems are efficient when outdoor PM2.5 is high.

Assessment of Ventilation System for Ro/Ro Ship Using CFD (전산 유체 해석에 의한 자동차 운반선 내부 환기 시스템 평가)

  • Lee, Sung-Su;Kim, Hak-Sun;Chun, Seung-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.1 s.139
    • /
    • pp.10-17
    • /
    • 2005
  • Due to emission of vehicles during loading/unloading, ventilation system in Roll-on/Roll-off ship is inevitable; however it is very difficult to predict the ventilation performance before it is finally built in. Although the requirements for the ventilation system include air change rate and maximum allowable concentration of CO in the cargo holds, even prototype tests are hardly able to quantify the ventilation performance. In the present paper, a new method to assess the ventilation performance of Roll-on/Roll-off ship is proposed by using computational fluid dynamics. The air exchange is modeled by introducing multi-species transport of existing air In the holds and new air from the ventilation system. Conservation of multi-species as well as 3D Navier-Stokes equation are solved numerically in time dependent manner. Several cases of different configuration are considered. The results include predicted mass fraction of new air in the holds. It is also presented that CO concentration can be estimated based on the predicted air change performance. Due to the lack of experimental data, the computed results are not verified; however the proposed method can be applied as au assessment tool.

분배계통에 따른 지하주차장 환기설비 성능의 예측

  • 김경환;이재헌;오명도;김종필
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.10
    • /
    • pp.982-992
    • /
    • 2001
  • In this paper, the performance of ventilation equipments in enclosed parking garages were investigated for several air distribution systems by numerical method. Air change effectiveness of the non-mixing system was 0.42. It meant that more supply air as much as the design supply air was needed to maintain good indoor air quality. In the high speed nozzle ventilating system which is most expensive one, air change effectiveness was 0.54. Therefore this system satisfied to ventilation design. In the jet fan ventilating systems, air change effectiveness for jet fan ventilating system-A with 18 jet fans and jet fan ventilating system-B with 6 jet fans in circulation mixing arrangement were 0.565 and 0.42 respectively. Jet fan ventilating system-C with 6 jet fans in transport mixing arrangement was 0.535. Jet fan ventilating system-A and jet fan ventilating system-C met the ventilation design. But velocity in jet fan ventilating system-A was over 2.0m/s which is inappropriate in human comfort. Therefore this system is not proper to ventilation. Jet fan ventilating system-C was the optimum one for enclosed parking garages among 5 systems examined in this paper.

  • PDF

The Effect of Ventilation and Concentration of Indoor Air Quality at Indoor Parking Lots (실내주차장의 실내공기질 농도특성 및 환기에 의한 저감효과)

  • Park, Jeong-Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.4
    • /
    • pp.241-247
    • /
    • 2010
  • Recently, indoor air quality (IAQ) has been one of the major concerns of people. Indoor parking lots are subject to be exposed to high concentrations of air pollutants emitted from vehicles. This study was performed to investigate indoor air quality (IAQ) at indoor parking lots. Sampling sites were selected 5 indoor parking lots. Target indoor air quality parameters include a number of criteria pollutants such PM$_{10}$, CO, CO$_2$, and HCHO. In addition, a variation of IAQ according to ventilation system operating was measured at C site (underground parking lot). In general, all pollutants were maintained below indoor air quality maintenance standards. The indoor air quality at indoor parking lots was affected by the availability of the ventilation facility and their operation frequency. At the underground parking lot (C site) with ventilation system, TVOC concentration according to ventilation system operating were found to be lower operating (488.2 ${\mu}g/m^3$) than non-operating (1,401.2 ${\mu}g/m^3$).

A Development of Coupled Simulation Tool to Evaluate Performance of Ventilation System (환기시스템의 성능평가를 위한 통합 시뮬레이션 Tool의 개발)

  • Cho Wang-Hee;Song Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.112-121
    • /
    • 2006
  • To evaluate the performance of ventilation system properly, the correlations among the ventilation rate, indoor air-quality and cooling/heating load should be analysed. In this study, simulation tool to analyze the performance of ventilation system was developed. The simulation tool is based on the TRNSYS and some modules to calculate concentration of pollutants with the operation of ventilation system and to decide the signal of ventilation system were newly developed in this study. And these modules coupled with building load and heating/cooling simulation modules. To verify the validity of developed simulation tool, comparison study between simulation and field study were accomplished. As results, the simulation tool developed in this study can be used to predict the performance of ventilation system with accuracy.

A Study of Hybrid Ventilation System applying to an Apartment House (공동주택용 하이브리드 환기설비에 관한 연구)

  • Yi, Seong-Hwan
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1137-1143
    • /
    • 2006
  • The purpose of this research lays on examining the adequacy of the hybrid ventilation system. The hybrid ventilation system must satisfy the next to be used. Firstly, the cold-draft phenomenon must not exist in the occupied zone. Secondly, the condensation must not happen on the surfaces of vents. Thirdly, the flow of make-up air must be happened in an each space by exhausted air of a rest room and living room. We used an examination and CFD method to verify these. Trough the examination of air-vents, We confirmed that the cold-draft to be induced by make-up air does not happen and could not find the condensation in the limits of outdoor temperature higher than 265K. Through CFD simulation, We confirmed that the rapid temperature change existed only within 0.5m the occupied zone and the flow of air was happened in an each space by only exhausted air in the rest room and living room. Consequently, the hybrid system is possible method to an apartment house.

  • PDF

Numerical Analysis on the Coupled Operation of Ventilation Window System and Central Cooling System (창호일체형 환기시스템 및 중앙냉방시스템 연계 운영에 대한 수치해석적 연구)

  • Park, Dong Yoon;Chang, Seongju
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.4
    • /
    • pp.385-395
    • /
    • 2015
  • This study evaluated indoor environmental characteristics in an office room equipped both with ventilation window system and central cooling system. Fresh air is supplied only by the central cooling system whereas indoor air is discharged outside through both ceiling diffuser and a ventilation window system. Numerical study is conducted by changing the volumetric flow rates of exhaust ports of each system. For estimating the performance of this coupled system, $CO_2$ concentration and Predicted Mean Vote (PMV) were calculated using Computational Fluid Dynamics (CFD) simulation. The more the ceiling diffuser exhausts indoor air, the more the $CO_2$ concentration decreases. However, when the ventilation window system exhausts more indoor air, thermal comfort level gets improved in the office room with cooling system. Therefore, when the ventilation window system is operated, the coupled operation with central cooling system should be considered for enhancing indoor air quality and thermal comfort, together.

A Numerical Analysis on Forced Ventilation using Indoor Air Cleaner in an Apartment House (아파트주택에 있어서 실내공기청정기에 의한 환기의 수치해석)

  • 고재윤;김일겸;최병훈;임장순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.217-223
    • /
    • 2001
  • There exist a number of approaches which can evaluate ventilation and indoor air quality. The measurement and analysis of indoor carbon dioxide concentrations can be useful for evaluating indoor air quality and ventilation. This paper describes a numerical analysis of carbon dioxide concentrations for evaluating indoor air quality and ventilation and the factors the need to be considered in their use. The conditions of this numerical analysis are tow types of positions and inlet velocities of ventilation system in a two-dimensional model of an apartment house. The simulation results could be used as a base data for further analysis for ventilation design of other industrial processes producing a proper ventilation system for a healthier and more comfortable environment in a building.

  • PDF

A Study on the Performance Evaluation of the Hybrid Ventilation System for Small Apartment Houses (소형 공동주택의 하이브리드 환기시스템 성능실험 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Lee, Jong-Sung;Kim, Sang-Hee
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.696-701
    • /
    • 2008
  • From Feb. 2006, the ventilating systems with air exchange rate of over 0.7times/hour are installed at the apartment houses (over 100 units). Installation cost and maintenance cost are very important factors for ventilating system because consumers have to pay the expenses of that system. Especially small apartment needs more considerations because small apartment is comparatively the economically weak part. The purpose of this study is to the performance evaluation of the hybrid ventilation system for small apartment houses. Hybrid system 1 consists of natural ventilation system and duct type exhaust diffusers. Hybrid system 2 has natural ventilation system and toilet exhaust system with static pressure fan. Infiltration of test apartment houses with ventilation system is under 0.1 times/hour. Mean air age of hybrid system 1 is 1.52 hours and hybrid system 2 is 1.42 hours. Mean ventilation effectiveness of hybrid system 2(93%) is higher than that of hybrid system 1(81%).

A Study on the using of the Ventilation System as the Method of Improvement of Air Quality in the Schools (학교건물의 공기질 개선을 위한 환기시스템 적용에 관한 연구)

  • Ahn, Chul-Lin;Kim, Jwa-Jin;Kum, Jong-Soo;Park, Hyo-Soon
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.2
    • /
    • pp.17-23
    • /
    • 2004
  • The purpose of this study concerns the improvement of air quality in school classrooms. Polluted indoor air is improved by efficient ventilation systems. So it is important to measure the amount of ventilation needed in classrooms. First, the amount of natural ventilation were measured through a tracer gas method. And we have established a heat recovery ventilation system from 4 cases of airflow in classrooms, and we have measured the change of $CO_2$ density. According to air quality measurements in the classrooms, the density of $CO_2$ is well above environmental standards which are acceptable. When the amount of ventilated airflow increases, indoor air quality is improved. It is surveyed that the most suitable amount of external inducted air is 770 CMH to satisfy $CO_2$ less than 1,000 ppm in classrooms. For improvement of air quality in classrooms, we must consider a suitable ventilation plan and installation of ventilation systems when constructing school buildings.