• Title/Summary/Keyword: Air Velocity

Search Result 2,853, Processing Time 0.031 seconds

Effect of Fin Spacings on Air-side Heat Transfer in Louvered Fin Heat Exchangers (핀 간격(間隔)이 루우버핀 열교환기(熱交換器)의 공기측(空氣側) 열전달(熱傳達)에 미치는 영향(影響))

  • Kim, S.J.;Chung, T.H.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.2 no.4
    • /
    • pp.288-294
    • /
    • 1990
  • A study has been conducted experimentally on heat transfer characteristics of louvered fin heat exchangers with various fin spacings in air. The experimental results are as follows; 1. Mean heat transfer coefficient is increased with increasing air velocity and the optimum fin spacing shows at S=5mm. 2. Pressure drop is increased with increasing air velocity and its maximum value shows at S=3.5mm and its minimum value shows at S=6mm. 3. $\bar{h}/{\Delta}P$ is decreased with increasing air velocity and its maximum value shows at S=5mm and its minimum value shows at S=3.5mm.

  • PDF

Experimental Study on Coefficient of air Convection with boundary layer and boiling effects (경계층과 비등효과를 고려한 외기대류계수에 관한 실험연구)

  • Choi Myoung sung;Kim Yun Yong;Song Young Chul;Woo Sang Kyun;Kim Jin Keun;Lee Yun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.711-714
    • /
    • 2004
  • The setting and hardening of concrete is accompanied with nonlinear temperature distribution caused by development of hydration heat of cement. In order to predict the exact temperature history in concrete structures it is required to examine thermal properties of concrete. In this study, the coefficient of air convection, which presents thermal transfer between surface of concrete and air, was experimentally investigated with variables such as velocity of wind, boiling and layer effects. Finally, the prediction model for equivalent coefficient of air convection was theoretically proposed. The coefficient of air convection in the proposed model increases with velocity of wind, and its dependance on wind velocity is varied with types of form. For determining the initial coefficient of air convection, boiling effects must be considered. The coefficient of air convection is affected by boundary layer with respect to the distance from the surface.

  • PDF

An Experimental Study on Flame Spread in One-Dimensional Droplet Array with Forced Convection (강제 대류하에서 일차원 액적 배열내의 화염 퍼짐에 관한 실험적 연구)

  • Park, Jeong;Lee, Kiman;Niioka, Takashi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.68-74
    • /
    • 2000
  • Experimental investigation on flame spread along suspended droplet arrays have been conducted with various droplet spacings and ambient air velocities. Especially, an opposed air stream is introduced to simulate fundamental flame spread behaviors in spray combustion. High-speed chemiluminescence imaging technique of OH radicals has been adopted to measure flame spread rates and to observe various flame spread behaviors. The fuel used is n-Decane and the air velocity varies from 0 to 17cm/s. The pattern of flame spread is grouped into two: a continuous mode and an intermittent one. It is found that there exists droplet spcings, above which flame spread does not occur. The increase of ambient air velocity causes the limit droplet spacing of flame spread to become small due to the increase of apparent flame stretch. As the ambient air velocity decreases, flame spread rate increases and then decreases after taking a maximum flame spread rate. This suggests that there exists a moderate air flowing to give a maximum flame spread rate due to enhanced chemical reaction by the increase of oxidizer concentration.

A Study on Response Characteristics of ionization Smoke Detector Influenced by Air Stream (이온화식 연기감지기의 기류응답특성 연구)

  • 이복영;정길순;이병곤
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.6-9
    • /
    • 2003
  • Recently, forced ventilating air conditioning system has been widely used in modern buildings. However, It is obvious that this kind of system may affect on the response of fire detectors at real fire incidents, especially, on the ionization smoke detector, which is critically influenced by air stream. Therefore we studied to verify the response characteristics of air stream by ionization smoke detector for the design of facilities in practice. In this study, experiments were executed to examine the correlation between air velocity and the ionization detector's responses with var-ious air velocity and smoke densities in the simulated test room. As a result of experiments, ionization detector's operating time is in reverse proportion to air velocity. And the detector shows more sensitive reaction when the velocity of smoke stream increase over 60 cm/s. In addition, it was shown that ionization smoke detector is more sensitive to smoldering fires in paper than that in petro-chemicals.

A Study on Indoor Thermal Environment in an Tower Type Apartment House at Tropical Nights (여름철 열대야 발생시 탑상형 아파트의 실내온열환경에 대한 연구)

  • Chang, Hyun-Jae;Kim, Hyung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.1
    • /
    • pp.20-25
    • /
    • 2010
  • In this study, As a basic research for improving indoor thermal environment at tower type apartment houses, specifications of heat storage and heat emission in the structures of apartment houses were investigated, and the ratio of indoor and outdoor air velocity at tower type apartment house was examined, too. Indoor temperature at night time was higher than outdoor air temperature because heat emission from the structure of wall, ceiling and floor those are constructed by use of reinforced concrete which has large heat capacity. The ratio of indoor and outdoor air velocity was lower than 0.1 and this was caused by the plan of tower type apartment house. PMV was in the range of 0.3~1.9, and was about 1.0 (it means slightly warm) at 10 : 00 p.m.. To improve indoor thermal environment in summer season at tower type apartment houses, it needs more investigation on specifications of heat storage and heat emission in the structure including winter season, and on the improvement of the ratio of indoor and outdoor air velocity.

A Study on the Variation of Airflow Velocity and Temperature upon the Design of Bio Clean Room(BCR) for Laboratory Animal Facilities by Numerical Simulation (실험동물 사육실용 바이오 크린룸(BCR)의 급기 온도 및 풍속 변화 특성에 관한 수치해석적 연구)

  • Park, Dong-Il;Chung, Kwang-Seop;Kim, Young-Il;Kim, Sung-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.578-584
    • /
    • 2012
  • In this study, the analysis on the distribution of indoor airflow velocity and temperature by using numerical simulation has carried out to make fundamental data for establishing the optimum design of laboratory animal facilities. From the results, it was found that replacement of cage lacks, air supply and exhaust system, supply air temperature, supply air velocity affect to the optimum design of laboratory animal facilities as a important element.

Effects of Relative Humidity on the Evaporator Pressure Drop (증발기의 압력강하에 대한 상대습도의 영향)

  • 김창덕;강신형;박일환;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.397-407
    • /
    • 2004
  • It is well known that some key parameters, such as evaporating temperature, refrigerant mass flow rate, face velocity and inlet air temperature, have significant influence on the evaporator performance. However performance studies related to a humid environment have been very scarce. It is demonstrated that the refrigerant mass flow rate, heat flux, water condensing rate and air outlet temperature of the evaporator significantly increase with air inlet relative humidity. As the air inlet relative humidity increases, the latent and total heat transfer rates increase, but the sensible heat transfer rate decreases. The purpose of this study is to provide experimental data on the effect of air inlet relative humidity on the air and refrigerant side pressure drop characteristics for a slit fin-tube heat exchanger. Experiments were carried out under the conditions of inlet refrigerant saturation temperature of 7 $^{\circ}C$ and mass flux varied from 150 to 250 kg/$m^2$s. The condition of air was dry bulb temperature of 27$^{\circ}C$, air Velocity Varied from 0.38 to 1.6 m/s. Experiments Showed that air Velocity decreased 8.7% on 50% of relative humidity 40% of that at degree of superheat of 5$^{\circ}C$, which resulted that pressure drop of air and refrigerant was decreased 20.8 and 8.3% for 50% of relative humidity as compared to 40%, respectively.

Analysis of NOx Emissions in Thrbulent Nonpremixed Hydrogen-Air Jet Flames with Coaxial Air (동축 수소 확산화염에서의 NOx 생성 분석)

  • Park, Y.H.;Kim, S.L.;Moon, H.J.;Yoon, Y.B.;Jeung, I.S.
    • Journal of the Korean Society of Combustion
    • /
    • v.5 no.1
    • /
    • pp.19-30
    • /
    • 2000
  • The characteristics of NOx emissions in pure hydrogen nonpremixed flames with coaxial air are analyzed numerically for the three model cases of coaxial air flames classified by varying coaxial air velocity and/or fuel velocity. In coaxial air flames, the flame length is reduced by coaxial air and can be represented as a function of the ratio of coaxial air to fuel velocity. Coaxial air decreases flame reaction zone, resulting in reducing flame residence time significantly. Finally, the large reduction of EINOx is achieved by the decrease of the flame residence time. It is found that because coaxial air can break down the flame self-similarity law, appropriate scaling parameters, which are different from those in the simple jet flames, are recommended. In coaxial air flames, the flame residence time based on the flame volume produces better results than that based on a cube of the flame length. And some portion of deviations from the 1/2 scaling law by coaxial air may be due to the violation of the linear relationship between the flame volume and the flame reaction zone.

  • PDF

Investigation into circulation of ground water by air sparging (Air sparging에 의한 지하수 순환에 관한 연구)

  • 이준희;강구영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.232-235
    • /
    • 1998
  • Air sparging system is a kind of in-situ bioremediation method in the contaminated ground water. When Air sparging, the both of water circulation and oxygen transfer happend in the same time. The hydraulic differential head is zero at the middle height of well, is negative below the height and is possitive above the height. Hydroraulic head gradient is proportioned to air superficial velocity in the well. But over 24m/min of the superficial velocity, the hydraulic head gradient increase little.

  • PDF

Air-Side Heat Transfer in Louvered Fin Heat Exchangers (Louvered fin 열교환기(熱交換器)의 공기측(空氣側) 열전달(熱傳達))

  • Kim, C.S.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.1
    • /
    • pp.82-86
    • /
    • 1989
  • A study has been conducted experimentally on heat transfer characteristics of the heat exchangers with louvered fins in air. The experimental results are as follows; 1. Mean heat transfer coefficient is decreased with increasing temperature difference and model III is the best at constant temperature difference. 2. Pressure drop is increased with increasing air velocity, but it is decreased as the heat transfer area increases. 3. $\bar{h}/^{\Delta}p$ is increased and then decreased as air velocity increases.

  • PDF