• Title/Summary/Keyword: Air Temperature

Search Result 10,359, Processing Time 0.038 seconds

The Effect of Operating Conditions on the Frost Formation in a Vertical Plate at a Low Temperature (저온 수직평판에서 착상에 대한 운전조건의 영향)

  • 이관수;이태희;김우승
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3305-3314
    • /
    • 1994
  • In this study, the influence of a frost formed on the vertical plate for different operating conditions(the temperature of the air, the humidity of the air, the velocity of the air, and the temperature of the cooling plate) is investigated. The performance of the heat exchanger is examined by introducing a parameter such as the energy transfer resistance. Correlations which relate frost density, frost thickness and energy transfer resistance to Reynolds number, air temperature and humidity, and cooling plate temperature are developed. Static pressure drop and air flow rate are expressed as a function of free flow area of air.

Evaluation of Indoor Air Quality in the Railroad Electric Rolling Stock - Focused on Temperature and Humidity - (철도 전동차내의 실내공기질 평가 - 온도 및 습도를 중심으로 -)

  • Park Duck-Shin;Bae Sang-Ho;Jung Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.610-615
    • /
    • 2003
  • Electric rolling stock is one of major public transportation because of an increase in population and heavy traffic problems. The passengers under the influenced of indoor air quality such as air temperature, relative humidity and air velocity. Ventilation system on passenger cars should be designed for the health and comfort of the passengers. One of the main aim is to create an acceptable thermal environment without draught problems. The draught sensation increases when the air temperature decreases and the air velocity increases. Airflow in passenger cars is turbulent. Lateral temperature and humidity gradients in the electric rolling stock have been studied. And, the difference in the mean temperature and relative humidity measured at 0.7, 0.9, 1.2, 1.7 m above from the floor.

  • PDF

Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems (사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험)

  • Cho, Yong;Kwon, Hyurk-Seung;Kim, Sung-Hyun;Kim, Young-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

Effect of Temperature Conditions on Electrochemical Properties for Zinc-Air Batteries (온도조건에 따른 아연-공기 전지의 전기화학적 특성)

  • Lee, Ju Kwang;Jo, Yong Nam
    • Korean Journal of Materials Research
    • /
    • v.30 no.12
    • /
    • pp.687-692
    • /
    • 2020
  • A zinc-air battery consists of a zinc anode, an air cathode, an electrolyte, and a separator. The active material of the positive electrode is oxygen contained in the ambient air. Therefore, zinc-air batteries have an open cell configuration. The external condition is one of the main factors for zinc-air batteries. One of the most important external conditions is temperature. To confirm the effect of temperature on the electrochemical properties of zinc-air batteries, we perform various analyses under different temperatures. Under 60 ℃ condition, the zinc-air cell shows an 84.98 % self-discharge rate. In addition, high corrosion rate and electrolyte evaporation rate are achieved at 60 ℃. Among the cells stored at various temperature conditions, the cell stored at 50 ℃ delivers the highest discharge capacity; it also shows the highest self-discharge rate (65.33 %). On the other hand, the cell stored at 30 ℃ shows only 2.28 % self-discharge rate.

Development of wireless wind chill temperature measurement system (무선 체감온도 측정 시스템 개발)

  • Kim, Hyung-Pyo;Kim, Jin-Gyu;Sohn, Kyung-Rak
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.245-250
    • /
    • 2009
  • The paper presents the wireless wind chill temperature measurement system that is composed of IEEE 802.15.4 standard wireless communication devices, hot film anemometer and serial communication temperature sensor. It's sometimes very difficult for a person, who lives in a high-rise apartment, to see the outside wind chill temperature due to harsh outside weather. The wind chill temperature is calibrated from an air velocity and air temperature. IEEE 802.15.4 standard wireless communication is ZigBee compatible, and consumes low power in communication. Under the air temperature of 5 $^{\circ}C$ and air velocity ranging from 0 to 50 km/h, the experimental result of wind chill temperature shows good accuracy within 5%.

Evaluation of Indoor Air Environment by Changing Diffuser Location and Air Temperature with Under Floor Air Conditioning System (바닥취출 및 흡입시스템 공조방식에서 취출조건 변경시 실내공기환경 평가)

  • Kim Se-hwan;Park Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.397-403
    • /
    • 2005
  • The thermal comfort of occupants is directly related to several environmental factors such as velocity of air flow, turbulence intensity and temperature distribution of indoor air. The purpose of this study is to evaluate the indoor air flow and temperature distribution in office area using under-floor air-conditioning system (UFAC System) based on the results from physical measurements and to perform a Computer Fluid Dynamics (CFD) under the same condition of inlet and outlet as field measurement. The results from the CFD simulation are similar to those from the field measurement. The results show that UFAC system is provide proper indoor condition for occupants.

Computational Study of the Mild Combustion and Pollutant Emission Characteristics in Wall-confined Jet (벽면으로 둘러싸인 제트 유동장에서의 마일드연소 및 오염물질 배출특성에 관한 전산해석 연구)

  • Song, Keum Mi;Oh, Chang Bo
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.263-266
    • /
    • 2012
  • The characteristics of mild combustion and pollutant emission were investigated computationally with supplied air stream temperature and dilution rate in jet flame. The air was diluted with main combustion products. As dilution rate increased at fixed air temperature, the temperature distribution of burner inside was uniformed and the maximum mole fraction of CO and NO was decreased. In addition, emission indices for NO, CO, and $CO_2$ were compared with air temperature and dilution rate.

  • PDF

Comparative Study of Fluidized Bed-type and Assmann Psychrometer (유동층습도계와 아스만습도계의 비교 연구)

  • 강희찬;강민철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.779-785
    • /
    • 2003
  • The present work proposed a newly developed fluidized bed-type psychrometer that could be applicable to the high temperature and contaminant gases. The psychrometer is a device that test gas passes through the water in a glass bottle as a bubbly flow to obtain the adiabatic saturation temperature. A fluidized bed-type psychrometer was made and its characteristics were compared with the Assmann Psychrometer. The characteristic time was in the order of a hundred seconds, and decreased for the decrease of the mass of water and the increase of the air flow rate. The air flow rate and the insulation of the glass bottle were definitely important in the accurate measurement of the wet bulb temperature. The error in wet bulb temperature became less than 5 percent of the difference of dry and wet bulb temperatures if the air velocity in the glass bottle was greater than 1.5m/s.

Analysis of Air Temperature Change Distribution that Using GIS technique (GIS 기법을 이용한 대기온도 변화 분포 분석)

  • Jung, Gyu-Young;Kang, In-Joon;Kim, Soo-Gyum;Joo, Hong-Sik
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2010.04a
    • /
    • pp.395-397
    • /
    • 2010
  • AWS that exist in Pusan is watching local meteorological phenomena established in place that the weather observatory does not exist by real time, and is used usefully to early input data of numerical weather forecasting model. I wished to display downtown of Pusan and air temperature change of peripheral area using this AWS data. Analyzed volatility using AWS observation data for 5 years to recognize air temperature change of Pusan area through data about temperature among them. Drew air temperature distribution chart by season of recapitulative Pusan area applying IDW linear interpolation with this.

  • PDF

Climate Change and Urban Air Temperature Increase in Korean Peninsula (기후변화와 한반도 도시지역의 기온 증가)

  • Oh, Sung-Nam;Ju, Ok-Jung;Moon, Yung-Su;Lee, Kyoo-Seock
    • Journal of Environmental Impact Assessment
    • /
    • v.19 no.2
    • /
    • pp.169-177
    • /
    • 2010
  • One of the most obvious climatic manifestations of urbanization in Korea is a trend towards higher air temperature. The trends of long-term annual temperature generally well describe the warming of urban areas. The increase of air temperature in urban area has been observed to the present since the meteorological observations in Korea began. The objective of this study is to explore the actual increase and the regional long-term trends of air temperature attributed to urbanization in the Korean Peninsula. Therefore, temperatures of the selected urban areas were compared with that of the surrounding rural areas, with the results varying by the application of the estimates of each region. The second objective is to separate the long-term trend of surface air temperature of global warming from urbanization and to find the actual temperature increase from urbanization in Korean peninsula. For the data analysis, daily air temperatures observed by the Korea Meteorological Administration (KMA) during between from 1961 and 2005 were used at five rural sites and cities. The re-analyzed surface air temperatures by the National Centers for Environmental Prediction (NCEP) was also carried out to compare the result from the observed air temperature in the Korean climate domain. In this study, the urban areas in Korea showed high increase rate of air temperature with $0.4^{\circ}C$ per decade during past 50 year period, while rural sites as Chupungryung with the $0.2^{\circ}C$ decadal increase rate. The analyses reflect that the urban area shows the high rate of temperature increase with $1.39^{\circ}C$ of regression value at the urban area, Seoul, and $0.43^{\circ}C$ at the rural site, Chupungnyeong during the period of 30 years. The temperature increas due to the urbanization only showed the increase range between $0.44^{\circ}C$ and $0.86^{\circ}C$, and the observed decrease in diurnal temperature range at five urban areas during the 30 years period.