• Title/Summary/Keyword: Air Mattresses

Search Result 8, Processing Time 0.024 seconds

Development of Variable Air Mattresses for Shelter based on Disaster Prevention Design (방재디자인기반 구호소 가변식 에어매트 개발)

  • Noh, Hwang-Woo;Chung, Yong-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.2
    • /
    • pp.80-87
    • /
    • 2022
  • Most of the disaster relief items provided to sufferers and temporary evacuees that are supposed to be victims in Korea are not suitable for the shelter environment of temporary housing facilities, and are not satisfactory because they do not have the functions, proper size and types. The purpose of this study is to analyze the user needs of emergency rescue relief items by presenting problems about the use environment and to develop the variable air mattresses which are based on disaster prevention design. In order to secure objectivity such as usability, convenience, and durability, research data are limited. However, the difficulty of mass spreading of conventional fiber mat and the functional disadvantages of foam plastic mat are solved by adopting variable air mattresses. The variable air mattresses are expected to help rehabilitate people by helping victims of physical tiredness, illness worsening, poor sleep, and life instability that can happen during long-term shelter life.

Changes in the Comfort and Image Quality of the Patient According to the Application of Air Mattresses in the Computed Tomography Table (전산화단층촬영 테이블의 에어 매트리스 적용에 따른 환자의 편안함과 화질 변화)

  • Young-Hee, Lee;Yong-Ki, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.889-896
    • /
    • 2022
  • This study attempted to evaluate the usefulness of the air mattress by analyzing the subjective comfort of the patient due to the application of the air mattress to the table of computed tomography through a questionnaire and analyzing the change in image quality through quantitative and qualitative evaluation of the patient's clinical images. The subjects who participated in the study were 221 men and 229 women, and the age range was from 18 to 86. To evaluate the change in image quality, a total of 150 patients, 50 patients per group, were selected for quantitative evaluation, and 20 patients per group, a total of 60 patients were selected for qualitative evaluation. As a result of this study, the subjective comfort of patients increased due to air mattresses, and there was no difference in image quality as a result of quantitative and qualitative evaluation of clinical images. From the above results, it is believed that the air mattress can be usefully applied in a way that can increase the subjective comfort of the patient without any harm to the diagnostic image.

Use of Home Nursing Therapy and Need of Home Care Equipments (가정간호환자의 치료적 간호서비스 제공과 의료기구 사용 및 요구도)

  • Ryu, Ho-Shin;Park, Chai-Soon;Kim, In-A;Kwon, Young-Dae;Kang, Sung-Wook
    • Research in Community and Public Health Nursing
    • /
    • v.19 no.2
    • /
    • pp.157-166
    • /
    • 2008
  • This study was conducted with whole home care nurses nationwide to provide secondary analyzed data to understand on their usage of medical equipments and their need of them for a month. This study found that treatments given by home care nurses were nelaton catheterization, bladder washing/urethral washing, newborn care, exchange and care for nasogastric tube and suction in that order of frequency. Second, instruments and equipments used for home care were reported to be stethoscope, patient monitor, blood pressure measuring equipment, air flotation mattresses, beds for patients, mattresses, suctioning device sets, enteral feeding equipment and dressing set in that oder of frequency. Moreover, need assessment of medical instruments and equipments showed renal dialysis was most needed and patient monitor, blood pressure measuring equipment, enteral feeding equipment, solution and other supplies for renal dialysis and beds for patient were necessary in that order. In conclusion, the results of this study investigating special treatments and medical instruments and equipments used for home care patients and analyzing patients' need, were expected to be useful for expansion of application of long-term care insurance for the elderly and health insurance as well as for quality control of home care and development of medial instruments and equipments used at home.

  • PDF

Image Quality Evaluation according to the Application of Air Mattress on Computed Tomography Equipment Table (전산화단층촬영장비 테이블의 에어 매트리스 적용에 따른 화질평가)

  • Jeon, Sang-Won;Pak, Jae-Yun;Suh, Tae-Suk
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.819-825
    • /
    • 2020
  • The purpose of this study was to evaluate the usefulness of the developed air mattress for reducing the deterioration of image quality due to the scattered radiation generated on the computed tomography equipment table. 5 cm and 10 cm thick air mattresses were developed and the image quality was measured by scanning the AAPM phantom according to thickness and thickness. Statistical significance was confirmed by One Way Analysis of Variance(ANOVA) Compared with the AAPM phantom scanned in the standard method, the image with the air mattress did not show any difference, but when the air mattress was not applied, the CT number and uniformity were low and the noise was high, and the spatial resolution Respectively. The developed air mattress has no harmful effect on the diagnostic image, it is very effective in improving the image quality and can increase the CT image quality by simply applying Air Mattress to existing equipment without using the technology applied to the latest and high-cost equipment.

A Novel Approach to Prevent Pressure Ulcer for a Medical Bed using Body Pressure Sensors

  • Young Dae Lee;Arum Park
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.3
    • /
    • pp.146-157
    • /
    • 2024
  • Despite numerous air mattresses marketed to prevent Pressure Ulcers (PU), none have fully succeeded due to residual pressure surpassing critical levels. We introduces an innovative medical bed system aiming at complete PU prevention. This system employs a unique 4-bar link mechanism, moving keys up and down to manage body pressure. Each of the 17 keys integrates a sensor controller, reading pressure from 10 sensors. By regulating motor input, we maintain body pressure below critical levels. Keys are equipped with a servo drive and sensor controller, linked to the main controller via two CAN series. Using fuzzy or PI/IP controllers, we adjust keys to minimize total error, dispersing body pressure and ensuring comfort. In case of controller failure, keys alternate swiftly, preventing ulcer development. Through experimental tests under varied conditions, the fuzzy controller with tailored membership functions demonstrated swift performance. PI control showed rapid convergence, while IP control exhibited slower convergence and oscillations near zero error. Our specialized medical robot bed, incorporating 4-bar links and pressure sensors, underwent testing with three controllers-fuzzy, PI, and IP-showcasing their effectiveness in keeping body pressure below critical ulcer levels. Experimental results validate the proposed approach's efficacy, indicating potential for complete PU prevention.

Effectiveness of Active Warming Intervention for Women Undergoing Cesarean Section: A Systematic Review and Meta-analysis (제왕절개 환자에서 적극적 가온 요법의 효과: 체계적 문헌고찰 및 메타분석)

  • Choi, Jung Eun;Kim, Mee Sun;Song, Jin Ran
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.24 no.3
    • /
    • pp.167-180
    • /
    • 2017
  • Purpose: The aim of this study was to synthesize the best available evidence for active warming interventions during cesarean section. Methods: A database search was done for randomized controlled trials utilizing active warming interventions. Maternal temperature, shivering and neonatal temperature were evaluated as outcome variables. Data were analyzed using Cochrane Review Manager software Version 5.3. Results: Thirteen studies including 1306 patients were reviewed. The degree of lowering of maternal temperature decreased in the warmed fluids (MD 0.51; p=.004) and warming mattress interventions (MD 0.22; p<.001) compared with control groups. Incidence of shivering was also lower in the active warming group (OR 0.55; p=.003). There was no statistically significant difference in maternal temperature with a forced air warming intervention (MD 0.64; p=.15) or in neonatal temperature (MD 0.12; p=.26). Conclusion: Findings show that with warmed fluids and warming mattresses applied during cesarean sections maternal temperature decline was reduced and also the incidence of shivering declined, but no significant effect was observed for forced air warming interventions. These findings provide a basis for developing a warming guideline for women having a cesarean section and will help to improve the quality of care for cesarean section patients.

Exposure Assessments on Biological Contaminants in Homes of Allergy Patients - Bacteria, Fungi, House Dust Mite Allergen and Endotoxin (알레르기 환자 가정에서 생물학적 유해인자에 대한 노출평가 -세균, 진균, 집먼지 진드기 알레르겐, 내독소를 대상으로)

  • Moon Kyong Whan;Byeon Sang Hoon;Choi Dal Woong;Kim Young Whan;Lee Jang Hee;Lee Eun Il
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.2 s.83
    • /
    • pp.120-126
    • /
    • 2005
  • To assess exposure of allergy patients to a biological environment, measurements were made of levels of airborne bacteria and fungi, house dust endotoxin and mite allergens in homes of 7 allergy patients and 12 healthy families. Concentrations of airborne total bacteria and the ratio of indoor and outdoor concentrations(I/O) in allergy patient's homes were high compared to non-allergy houses. But no significant differences could be shown for the concentration of spores of viable fungi and staphylococcus in indoor air between the homes of allergic patients and healthy families. The results of investigation on house dust mites, Dermatophagoids farinae were detected in all mattress samples and the levels in the allergy patient's homes were generally high, with individual measurements exceeding $2{\mu}g/g$ dust found in $30\%$ samples. In contrast with, Dermatophagoids pteronyssinus were detected in only $60\%$ samples and the concentrations were very low. The levels of endotoxin in dust samples collected from the allergy patient's home mattresses were higher than those of control houses. There was a positive correlation between the endotoxin levels and the house dust mite allergens.

Characteristics of Internal and External Exposure of Radon and Thoron in Process Handling Monazite (모나자이트 취급공정에서의 라돈 및 토론 노출 특성)

  • Chung, Eun Kyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.167-175
    • /
    • 2019
  • Objectives: The purpose of this study was to evaluate airborne radon and thoron levels and estimate the effective doses of workers who made household goods and mattresses using monazite. Methods: Airborne radon and thoron concentrations were measured using continuous monitors (Rad7, Durridge Company Inc., USA). Radon and thoron concentrations in the air were converted to radon doses using the dose conversion factor recommended by the Nuclear Safety and Security Commission in Korea. External exposure to gamma rays was measured at the chest height of a worker from the source using real-time radiation instruments, a survey meter (RadiagemTM 2000, Canberra Industries, Inc., USA), and an ion chamber (OD-01 Hx, STEP Co., Germany). Results: When using monazite, the average concentration range of radon was $13.1-97.8Bq/m^3$ and thoron was $210.1-841.4Bq/m^3$. When monazite was not used, the average concentration range of radon was $2.6-10.8Bq/m^3$ and the maximum was $1.7-66.2Bq/m^3$. Since monazite has a higher content of thorium than uranium, the effects of thoron should be considered. The effective doses of radon and thoron as calculated by the dose conversion factor based on ICRP 115 were 0.26 mSv/yr and 0.76 mSv/yr, respectively, at their maximum values. The external radiation dose rate was $6.7{\mu}Sv/hr$ at chest height and the effective dose was 4.3 mSv/yr at the maximum. Conclusions: Regardless of the use of monazite, the total annual effective doses due to internal and external exposure were 0.03-4.42 mSv/yr. Exposures to levels higher than this value are indicated if dose conversion factors based on the recently published ICRP 137 are applied.