On-Line Diagnosis Method for Generator Rotor Windings (발전기 운전중 회전자 진단에 관한 연구)

  • Lee, Young-Jun;Kong, Tae-Sik;Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1846-1849
    • /
    • 2002
  • A shorted-turn test was performed at the Sininchon combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line diagnosis system. The flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change of the flux. This pattern of flux variation is a signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.

  • PDF

A Study on the Reliability Analysis for a Linear Type Pneumatic Actuator with Cross Roller Guide (리니어 타입 크로스 롤러 가이드 공압 액추에이터의 신뢰성 평가에 관한 연구)

  • Shin Bong-Cheol;Cho Myeong-Woo;Kang Sung-Min;Lee Soo-Jin;Choi Jin-Hwa
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.5 s.182
    • /
    • pp.184-189
    • /
    • 2006
  • This research presents the performance analysis of the linear type pneumatic actuators that are used in semi-conductor assembly line to transfer some product with high accuracy. To increase positioning and repetitive accuracies, a cross roller guide is implemented inside the pneumatic actuator. The finite element method is used to verify the force against working moments, and reliability analysis is performed to classify the breakdown cases. Also, reliability, failure rate, probability density function, and $B_{10}$ to life are estimated under the boundary of thrust or air leakage conditions. In this study, the failure probabilistic function of the pneumatic actuators is analyzed using Weibull distribution.

A Study on the Stack Effect Characteristics in High-Rise Apartments (초고층 주상복합 아파트의 연돌효과 특성에 관한 연구 -D 프로젝트를 중심으로-)

  • Choi, Dong-Tak;Son, Won-Tug;Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.1
    • /
    • pp.37-43
    • /
    • 2011
  • Study of stack effects in the early design stage is the most appropriate moment to draw any problems and provide the right solutions. However, In a real process, The pre-design planning stage review is not thoroughgoing enough to high-rise construction site. Therefore, this study has reviewed by selecting one of inappropriate project [D] to find the possible stack effect alternatives in an early design documentation stage and provide countermeasures to be a foundations of stack effect in the construction stages.

Development of Shorted-Turn Sensor for Synchronous Generator's Field Winding (동기발전기 계자권선의 층간단락 감지센서 개발)

  • Cho, Ji-Won;Lee, Byung-Ha;Lee, Young-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2114-2116
    • /
    • 1999
  • The shorted-turn sensor for synchronous generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a shorted-turn test was performed at the Seoinchon combined cycle power plant on gas turbine generator. This sensor will be used as a detecting of shorted-turn for synchronous generator's field winding.

  • PDF

Shorted-Turn Detction Techniques for Generator Rotor (발전기 운전중 회전자 계자권선의 단락 진단기법에 관한 연구)

  • Lee, Young-Jun;Kim, Hee-Dong;Park, Jong-Jeong;Ju, Young-Ho;Joe, Ji-Won;Lee, Byung-Ha
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1721-1724
    • /
    • 1998
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas. turbine generator #4. The test was conducted using a permanent flux probe and digital oscilloscope. The flux probe installed in the generator air gap, senses the field winding slot leakage flux and produces a voltage proportional to the rate of change of the flux. This pattern of flux variation is a signature unique to each field winding. We have also applied a waveform analysis technique that can identify the pole location, slot number, and number of shorted-Turns with each slot.

  • PDF

Electrical characteristics of low-k SiOCH thin film deposited by BTMSM/$O_2$ high flow rates (BTMSM/$O_2$ 고유량으로 증착된 low-k SiOCH 박막의 전기적인 특성)

  • Kim, Min-Seok;Hwang, Chang-Su;Kim, Hong-Bae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.1
    • /
    • pp.41-45
    • /
    • 2008
  • We studied the electrical characteristics of low-k SiOCR interlayer dielectric(ILD) films fabricated by plasma enhanced chemical vapor deposition (PECVD). The precursor bis-trimethylsilylmethane (BTMSM) was introduced into the reaction chamber with the various flow rates. The absorption intensities of Si-O-$CH_x$, bonding group and Si-$CH_x$, bonding group changed synchronously for the variation of precursor flow rate, but the intensity of Si-O-Si(C) responded asynchronously with the $CH_x$, combined bonds. The SiOCH films revealed ultra low dielectric constant around 2.1(1) and reduced further below 2.0 by heat treatments.

  • PDF

Assessment of Insulation Condition for Generator Rotor Windings (발전기 회전자 권선의 건전성 평가)

  • Lee, Young-Jun;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.59-60
    • /
    • 2006
  • A shorted-turn test was performed at the Pyungtaek combined cycle power plant on gas turbine generators. The test was conducted using a permanent flux probe and on-line shorted-turn diagnosis system. The permanent flux probe installed in the generator air gap senses the field winding slot leakage flux and produces a voltage proportional to the rate of change signature unique to each field winding. We have also applied a voltage waveform analysis technique that can identify the pole location, slot number and number of shorted-turn with each slot.

  • PDF

Clinical Evaluation of Spontaneous Pneumothorax A Review of 165 cases (자연기흉의 임상적 고찰: 165례)

  • 성후식
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.582-588
    • /
    • 1985
  • We have observed 165 cases of spontaneous pneumothorax from Aug. 1978 to May. 1985 at the department of Thoracic and Cardiovascular Surgery, School of Medicine, Keimyung University. The ratio of male to female cases were 8.2:1 in male predominance, and the incidence was highest in the adolescence between 21 to 30 year of age. There were 85 patients of primary spontaneous pneumothorax and 80 patients of secondary spontaneous pneumothorax. The etiologic factors of secondary spontaneous pneumothorax were tuberculous origin in 50 cases, chronic bronchitis with emphysematous bullae or blebs in 17 cases, asthma in 10 cases and lung cancer in 3 cases. Closed thoracotomy was performed for reexpansion of collapsed lung in 153 cases, bed rest in 3 cases, needle aspiration in 5 cases and open thoracotomy in 14 cases. Closed thoracotomy was the main therapeutic approach of choice in the great majority of spontaneous pneumothorax with recurrence rate of 21.6%. However, open thoracotomy was undertaken in patients with continuous air leakage, recurrent episodes, bilateral pneumothorax and large visible apical blebs or bullae.

  • PDF

Numerical analysis study on the concentration change at hydrogen gas release in semi-closed space (수치해석을 통한 반밀폐공간 내 수소가스 누출 시 농도변화에 관한 연구)

  • Baek, Doo-San;Kim, Hyo-Gyu;Park, Jin-Yuk;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.1
    • /
    • pp.25-36
    • /
    • 2021
  • Hydrogen in hydrogen-electric vehicles has a wide range of combustion and explosion ranges, and is a combustible gas with a very fast flame propagation speed, so it has the risk of leakage, diffusion, ignition, and explosion. The fuel tank has a Thermally active Pressure Relief Device (TPRD) to reduce the risk of explosion and other explosions, and in the event of an accident, hydrogen inside the tank is released outside before an explosion or fire occurs. However, if an accident occurs in a semi-closed space such as an underground parking lot, the flow of air flow is smaller than the open space, which can cause the concentration of hydrogen gas emitted from the TPRD to accumulate above the explosion limit. Therefore, in this study, the leakage rate and concentration of hydrogen over time were analyzed according to the diameter of the nozzle of the TPRD. The diameter of the nozzle was considered to be 1 mm, 2.5 mm and 5 mm, and ccording to the diameter of the nozzle, the concentration of hydrogen in the underground parking lot increases in a faster time with the diameter of the nozzle, and the maximum value is also analyzed to be larger with the diameter of the nozzle. In underground parking lots where air currents are stagnant, hydrogen concentrations above LFL (Lowe Flammability Limit) were analyzed to be distributed around the nozzle, and it was analyzed that they did not exceed UFL (Upper Flammability Limit).

The Comparative Analysis of Drying-Conditions, -Rates, -Defects and Yield, and Heat-Efficiency in Solar-Dehumidification-Drying of Oaks With Those in Conventional Air-, Semi-Greenhouse Type solar-, and Kiln- Drying (참나무류(類)의 제습태양열건조(除濕太陽熱乾燥)의 조건(條件), 속도(速度), 결함(缺陷), 수율(收率) 및 열효율(熱效率)과 관행(慣行) 천연(天然), 반온실형(半溫室型) 태양열(太陽熱) 및 열기건조(熱氣乾燥)와의 비교(比較)·분석(分析))

  • Lee, Hyoung-Woo;Jung, Hee-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.22-54
    • /
    • 1989
  • Seasonal semi-greenhouse type solar-drying of 2.5cm-and 5.0cm-thick lumber of Quercus aliena Blume and Quercus variailis Blume was carried out to investigate the possibility of solar-drying of wood and to decide the active solar-drying period in Korea. In the active solar-drying period obtained solar-dehumidification, semi-greenhouse type solar-, air- and kiln-drying of 2.5cm -thick lumber of oaks were carried out to analyze drying-rates. -defects, and -yield in each drying-method and to calculate daily total absorbed solar-radiation the solar dryers. The energy balance equations were set up, considering all the energy requirements, to analyze the heat efficiencies of semi-greenhouse type solar and solar-dehumidification-dryer. In a seasonal drying the drying rate of semi-greenhouse type solar-dryer was highest in summer, and greater in fall, spring, and winter in order. Solar-drying time was 45% in summer to 50% in winter of the air-drying rime, and more serious drying-defects occurred in air-drying than in solar-drying. In the active solar-drying period. April, May, and June, the average drying rate in solar-dehumidification-drying was 1.0%/day and greater than 0.8%/day in semi-greenhouse type solar-drying. In solar-dehumidification-drying the time required to dry lumber to 10% moisture content was less than 60 days, and solar-dehumidification-drying showed the highest drying-yield, 65.01%, than the other drying methods. The daily total absorbed solar radiations were 8.51MJ on the roof collector and 6.22 MJ on the south wall collector. In the energy blance 69.48% of total energy input was lost by heat conduction through walls, roof. and floor 11.68% by heat leakage, 0.33% by heating the internal structures of the solar-dryer and 5.38% by air-venting. Therefore the heat efficiency of semi-greenhouse type solar-dryer 13.13%, was lower than that of solar-dehumidification-dryer, 14.04%. Solar-drying of lumber in Korea showed the possibility to reduce the air-drying-time in every season and the efficiency of solar-dehumidification drying was higher than that of semi-greenhouse type solar-drying.

  • PDF