• 제목/요약/키워드: Air Leakage

검색결과 538건 처리시간 0.025초

건축물 구획실간 틈새에서의 누설유동에 대한 수치모델 연구 (Study on Numerical Model of Leakage Flow at Gap between Compartments in a Building)

  • 김정엽;김지석
    • 설비공학논문집
    • /
    • 제25권10호
    • /
    • pp.562-567
    • /
    • 2013
  • 1D-numerical analysis of the network algorithm with the orifice equation for the relationship between pressure difference and flowrate has been mostly used to analyse leakage flow at the gap. In this study, a 3D-numerical method applying momentum loss model to the gap region in the computational domain is represented to reflect effectively the effect of leakage flow by determining the proportion of pressure difference to air passage velocity. While the 3D-numerical method is verified through the computation of the two compartments model, the numerical analysis of the stack effect in a building stairway is performed. As the temperature of air outside drops, the pressure in the upper stairway and leakage flowrate through the gap in the door rise. The change of gap area does not have an effect on pressure in the stairway for the analysis conditions.

복공식 지하 압축공기에너지 저장공동 기밀시스템 설계변수의 민감도 해석 (Sensitivity Analysis of Design Parameters of Air Tightness in Underground Lined Rock Cavern (LRC) for Compressed Air Energy Storage (CAES))

  • 김형목;;류동우;선우춘;송원경
    • 터널과지하공간
    • /
    • 제21권4호
    • /
    • pp.287-296
    • /
    • 2011
  • 본 연구에서는 압축공기에너지 지하저장을 위한 복공식 암반공동의 기밀성능을 평가할 목적으로 다상유체 열유동 해석을 수행하였다. 기밀성능은 저장공동으로부터 누출되는 공기질량으로 평가하였으며, 저장공동 내부에 콘크리트 라이닝 기밀시스템을 설치하고 저장공동은 비교적 천심도인 지하 100m 심도에 위치하는 것으로 가정하였다. 저장공동 내 질량수지분석 결과, 콘크리트 라이닝 및 주변 암반의 투과계수가 누기량 및 저장공동의 장기적 기밀성능에 미치는 영향이 큰 것으로 파악되었으며 콘크리트 라이닝의 투과계수가 $1.0{\times}10^{-18}\;m^2$이하 일 경우, 저장공동 운영압력이 5 MPa에서 8 MPa 사이일 때 누기량은 1%이하 인 것으로 계산되었다. 또한, 콘크리트 라이닝의 초기포화도에 따른 공기누출량 계산결과, 라이닝 수분포화도를 증가시킬수록 누기량은 감소하고 저장공동 기밀성능이 향상됨을 확인하였다.

Experimental investigations on the resistance performance of a high-speed partial air cushion supported catamaran

  • Yang, Jinglei;Lin, Zhuang;Li, Ping;Guo, Zhiqun;Sun, Hanbing;Yang, Dongmei
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.38-47
    • /
    • 2020
  • The partial air cushion supported catamaran (PACSCAT) is a novel Surface Effect Ship (SES) and possesses distinctive resistance performance due to the presence of planing bottom. In this paper, the design of PACSCAT and air cushion system are described in detail. Model tests were carried out for Froude numbers ranging from 0.1 to 1.11, the focus is on the influence of air cushion system on resistance characteristics. Drag-reducing effect of air cushion system was proved by means of contrast tests in cuhionborne and non-cushionborne mode. Wave-making characteristics reflect that the PACSCAT would eventually enter planing regime, in which the air could just escape under the seals and the hull body could operate in a steady state. To acquire different air cushion pressure, air flow rate and leakage height were adjusted during tests. Experimental results show that the resistance performance in planing regime would decrease evidently as the increased air flow rate, however, the scheme with medium leakage height presents the best resistance performance in the hump region.

고기밀 고단열 주택의 기밀성능에 관한 실험적 연구 (Experimental Study on Airtightness Performance of the House with High Levels of Insulation and Airtight Construction)

  • 신우철;윤종호;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.61-67
    • /
    • 2005
  • The purpose of this study is to evaluate the air tightness of Zero Energy Solar House(ZeSH) and to propose the construction improvement of junctions and penetrations where air infiltration was identified. Air leakage rate were measured by means of blower door test in accordance with ASTM E779-87. The results showed that ZeSH has an excellent airtightness with ACH50/20 (air change per hour at a pressure difference of 50 Pa between inside outside) of 0.34hr-1 and leakage class E by normalized leakage area of ASHRAE.

건물의 유효누출면적 및 박스모델을 이용한 염소 실내 누출의 위험지역 완화에 관한 연구 (A Study on the Mitigation of Threat Zones for Indoor Chlorine Release using Effective Leakage Areas of Building and Box Model)

  • 곽솔림;이은별;최영보
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.51-59
    • /
    • 2018
  • It is difficult to determine the outdoor toxic level of hazardous chemicals that are leaked in the building, since there are no efficient ways to calculate how much percentage of the leaked chemicals is released into the outdoor atmosphere. In address to these problems, we propose a reasonable box model that can quantitatively evaluate the mass rate of the indoor chlorine leakage into the outside of the building. The proposed method assumes that the indoor chlorine leakage is fully mixed with the indoor air, and then the mixture of the chlorine and indoor air is exfiltrated into the outside of the building through effective leakage areas of the building. It is found that the exfiltration rate of the mixture of the chlorine and indoor air is strongly dependent on the temperature difference between inside and outside the building than the atmospheric wind speed. As compared with a conventional method that uses a vague mitigation factor, our method is more effective to evaluate the outdoor toxic threat zone of the chlorine that are leaked in the building, because it can consider the degree of airtight of the building in the evaluation of the threat zone.

신축 공동주택의 누기특성 및 기밀성능 분석에 관한 연구 (The Air Leakage Characteristics and Airtightness Performance of a Newly Built Apartment)

  • 이윤규;신철웅
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.606-611
    • /
    • 2013
  • In responding to the recent framework convention on climate change, and the rise of the need for energy efficient buildings, such as Zero Energy Buildings (ZEB), domestic insulation standards and energy conservation regulations are being reinforced, to prevent heat loss. Accordingly, the Ministry of Land, Infrastructure and Transport have made amendments in Chapter 21 "Enforcement regulations for building facilities standards etc.", and Chapter 22 "Energy conservation standard", to reflect these changes. To effectively implement these regulations, it is required to propose air-tightness test methods, and establish air-tightness standards, based on the air leakage characteristics of domestic apartment housings. This research has been done primarily to collect basic technical data, to provide guidance for the establishment of domestic air-tightness standards for new apartment housing, through studying air-tightness test methods, field measurement on air-tightness of new apartment housings, and air leakage characteristics of major developed countries.

진공용 공기베어링의 성능해석 (Performance Analysis of a Vacuum-Compatible Air Bearing)

  • 김경호;박천홍;이후상;김승우
    • 한국정밀공학회지
    • /
    • 제23권10호
    • /
    • pp.103-112
    • /
    • 2006
  • This paper describes a theoretical analysis and experimental verification on the performances of a vacuum-compatible air bearing, which is designed with a cascaded exhaust scheme to minimize the air leakage in a vacuum environment. The design of the vacuum-compatible air bearing equipped with the differential exhaust system requires great care because several design parameters, such as the number of exhaust stages, diameter of exhaust tube, pumping speed of a vacuum pump, and bearing clearance greatly influence the air leakage and thus degree of vacuum. In this study, a performance analysis method was proposed to estimate the performances of the air bearing, such as load capacity, stiffness, and air leakage. Results indicate that the load capacity and stiffness of the air bearing was improved as its boundary pressure, which was determined by the $1^{st}$ exhaust method, was lowered, and the dominant factors on the chamber's degree of vacuum were the number of exhaust stages, exhaust tube diameter and bearing clearance. A vacuum chamber and air bearing stage using porous pad were fabricated to verify the theoretical analysis. The results demonstrate that chamber pressure up to an order of $10^{-3}$ Pa was achieved with the air bearing stage operating inside the chamber, and this analysis method was valid by comparing predicted values with experimental data, for the mass flow rates from the porous pad, and pressures at each exhaust port and chamber, respectively.

자연급기구내 플리머필터 설치 시 외기 침기량 분석에 관한 연구 (A study on performance of outdoor air flow rate through viovent for hybrid ventilation equipment)

  • 이성환;최종악
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1337-1342
    • /
    • 2009
  • This test was progressed in the test house of KICT as sectional research of Center for Sustainable Housing. It included a ventilation rate of hybrid ventilation equipment, temperature, and gas test using the SF-6. The purpose of this test is to demonstrate the performance of viovent by estimating an outdoor air flow rate through viovent which the flimmer filter is installed and decide the leakage after operating the constant airflow fan within a house. First, the outdoor airflow rate through viovent measured $130\;m^3/h$ more than a legal required ventilation rate, $104\;m^3/h$. And then it sufficiently satisfy a legal standard, 0.7 air change/h. Secondly, the result of this test exposes that the leakage in the residence is about $20{\sim}25%$. Especially, the outdoor air flowing through the gate occupies 50% of the total leakage.

  • PDF

Air leakage due to the cuff hanging on the vocal cords during nasotracheal intubation: a case report

  • Seung-Hwa Ryoo;Myong-Hwan Karm;Se-Ung Park;Hyun Jeong Kim;Kwang-Suk Seo
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제23권1호
    • /
    • pp.39-43
    • /
    • 2023
  • Nasotracheal intubation is commonly performed under general anesthesia in oral and maxillofacial surgery. For the convenience of surgery, nasal Ring-Adair-Elwyn (RAE) tubes are mainly used. Because the nasal RAE tubes were bent in an "L" shape, the insertion depth was limited. Particularly, it is necessary to accurately determine the appropriate depth of the RAE tubes in children. Several types of nasal RAE tubes are used in the medical market, which vary in material and length. We performed endotracheal intubation using a nasal RAE tube for double-jaw surgery, but air leakage persisted even when the air pressure in the cuff was increased. When checked with a laryngoscope, it was confirmed that the tube was pushed out, and the cuff was caught on the vocal cords, causing air leakage. Since inserting the tube deeply did not solve the problem, replacing it with a nasal RAE tube (PolarTM, Preformed Tracheal Tube, Smith Medical, Inc., USA) did not cause air leakage; thus, we reported this case.

시뮬레이션을 기초로한 누기보상 공압제어밸브시스템의 Design Approach에 관한 연구 (A Study n the Simulation-based Design Approach for Pneumatic Control System with Anti-leakage)

  • 김태형;정원지;최은재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.488-491
    • /
    • 1997
  • In this paper, a ncw control 'ialvc which can misc air-iraksge pneumatically and compensate pressure drop for an alrho~ st system uas proposed A new control valve called "Pneuniatic C70ntro1 Valve (PCV)" functions as a control valve to compcns;ltc prcssure in thc casc of air-leakage. by using the pure pneummatic control ofpilot pressure. Based on the sirnulation of the proposed PCY, thc experimental system was fabricaied su as to illustrate the efficient pcrformance of the proposed PCV with anti-leakage. Such good perfo~manccs of PCV in the air-hoist system are shown by the simulation. In addition, the simulation bascd design approach presented in this paper can be applied to any hydraulic or pneumatic-hydraulic system.

  • PDF