• Title/Summary/Keyword: Air Hygiene

Search Result 410, Processing Time 0.02 seconds

The Issue of Modern Dwelling in Sinhaksinseol(新學新說: New Knowledge New Theory) by Ji, Syok-young (지석영의 "신학신설" (1891)에서 근대적 주거 문제)

  • Kim, Myung-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.3
    • /
    • pp.765-770
    • /
    • 2008
  • Ji, Syok-young wrote a book named Sinhaksinseol(新學新說) in 1891, one of the first hygiene books in Korea. There were the conditions of modern housing like lighting, ventilation and dry and fresh air of a housing site in the contents of the book. Because the book was written when the modern hygiene theory had just been accepted, traditional concept of 'Yangseng(養生),' but it dealt the main environmental conditions of hygienic housing at first, which makes it the leader of modern housing discourses through the newspapers, magazines, academic journals or textbooks from 1890s mid to 1910.

Effect of non-thermal atmospheric pressure nitrogen and air plasma on the surface properties and the disinfection of denture base resin (상온대기압 질소 및 공기 플라즈마가 의치상용 레진의 표면 특성과 살균효과에 미치는 영향)

  • Seo, Hye-Yeon;Yoo, Eun-Mi;Choi, Yu-Ri;Kim, Soo-Hwa;Kim, Kwang-Mahn;Kim, Kyoung-Nam
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.5
    • /
    • pp.783-788
    • /
    • 2014
  • Objectives : The purpose of this study was to investigate the effect of non-thermal atmospheric pressure plasma jet(NTAPPJ) on surface properties and Streptococcus mutans disinfection of denture base resin. Methods : Self-cured denture base resin (Jet denture repair resin, Lang dental Mfg, co., USA) was used to make specimen($12mm{\times}2mm$). To observe surface change before and after plasma process, surface roughness and contact angle were measured. For sterilization experiments, the surfaces of specimens were treated with nitrogen and air NTAPPJ for 1 minute after S. mutans was inoculated on the material surfaces. Results : Before plasma process, surface roughness of denture base resin was $0.21{\mu}m{\pm}0.02{\mu}m$. After air and nitrogen NTAPPJ process, surface roughness was $0.19{\mu}m{\pm}0.03{\mu}m$ and $0.18{\mu}m{\pm}0.01{\mu}m$ respectively. There was no significant difference(p>0.05). Contact angle of control group without plasma process was $83.81^{\circ}{\pm}3.14^{\circ}$, while after plasma treatment, contact angles of air NTAPPJ and nitrogen NTAPPJ groups were $63.29^{\circ}{\pm}2.27^{\circ}$ and $46.68^{\circ}{\pm}5.82^{\circ}$ respectively. The result showed a significant decrease in contact angle after plasma process(p<0.05). Compared to the control group 6020.33(CFU/mL) without plasma process, CFU decreased significantly after air NTAPPJ 90.75(CFU/mL) and nitrogen NTAPPJ 80.25(CFU/mL) treatment(p<0.05). Conclusions : It was considered that NTAPPJ can be used for denture disinfection without changing surface properties of materials.

Application of Air Lift Pump for Sludge Discharger (공기 양정(air lift) 펌프를 응용한 슬러지 배출장치에 대한 연구)

  • Ahn Kab-Hwan;Park Young-Seek
    • Journal of Environmental Science International
    • /
    • v.13 no.10
    • /
    • pp.929-938
    • /
    • 2004
  • Sludge discharger applied the principle of the air lift pump was investigated experimentally for the different design( diameter of discharge pipe, diameter and height of the inside and outside wall) and operating parameters(air flow rate, water level). And it was conducted that performance comparison about sludge discharger and conventional air lift pump. The result indicated that discharged liquid were increased with the increase of air flow rate and water level and decrease distance between inside and outside wall. The discharge pressure was increased with an increase of air flow rate and a decrease of the diameter of the discharge pipe, for both the sludge discharger and the airlift pump. The discharge pressures of the sludge discharger were 3-6 times higher than those of the air lift pump.

The Number and Distribution of Bacteria falling in the Air of Dental Clinics (치과의원 공기중의 공중낙하세균수와 세균분포)

  • Jang, Gye-won;Kang, Yong-ju
    • Journal of dental hygiene science
    • /
    • v.4 no.1
    • /
    • pp.7-11
    • /
    • 2004
  • The purpose of this study was to investigate the distribution of microorganisms and the degree of contamination in the air of the dental clinics and to offer basic data as to the contamination of medical equipment and the prevention of the clinics. With this in mind, the researcher gathered air samples from the waiting rooms and medical offices of nine dental clinics in the city of J, South Korea with the use of a method of natural inattention and an air sampler and cultivated the samples on the plain table and drew from it bacteria falling and separated and sorted out the colony with the help of ATB and detected the distribution of the germs. The results are following, The number of bacteria falling in the air of the dental clinics was less than 10(CFU/Plate) with the exception of one dental clinic. This implies that they fit in with standards for hygiene. The number of bacteria falling in the air of the medical offices was less than 10(CFU/Plate) with the exception of one dental clinic. This implies that they fit in with standards for hygiene. The survey on the detection of staph. aureus reveals that all the dental clinics with the exception of B dental clinic proving to be positive had non-pathogenic staphylococci detected. The survey on the detection of pathogenic gram negative bacilli indicates that all the dental clinics but one were none detected. The survey on the distribution of germs shows that germs in 7 out of 9 dental clinics were none detected, and that they in four out of 9 waiting rooms were none detected. All the germs detected in the others were mostly non-pathogenic. The study shows that all the subject dental clinics but one were hygienically controlled and that there was a difference in accordance with cleaning and sterilization. This means that dental clinics should be equipped with systematic programs for cleaning and sterilization designed to prevent infection.

  • PDF

Hygienic Aspects of Campylobacter Enteritis (Campylobacter장염에 의한 식품위생학적인 고찰)

  • 이용욱;홍종해
    • Journal of Food Hygiene and Safety
    • /
    • v.1 no.1
    • /
    • pp.57-66
    • /
    • 1986
  • Campylobacter jejuni has been recognized as one of the causes of human gastroenteritis. The feces of a variety of reservoir animals contain c. jejuni as commensals in the intestinal tracts, and are fundamental source of contamination. The intestinal organisms contaminate carcasses, equipment tools hands of the processing line workers and air of the processing facility. Once the contamination happens in the slaughterhouses or the meat processing facilities, it is very difficult to keep the carcasses free from the infection of c. jejuni. Various disinfectants are effective in minimizing the number of Campylobacter infections in the processing facilities by washing contaminated carcasses, tools, and hands. Direct contact with infected animals has been incriminated in transmission of infection caused by C. jejuni. Freezing, cooling with dry air and gamma irradiation are an effective way for preserving the meat and eliminating the transmission, but broad and enforced studies are needed for the practical use.

  • PDF

Determination of Benzene in the Casting Process by GC-MS and GC (주조작업장 공기 중 벤젠의 정량)

  • Oh, Doe Suk;Lee, Byoung Jae;Lee, Seong Min;Kim, Young Ju
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.206-211
    • /
    • 2001
  • This article describes identification and quantification of benzene in the casting process. Air samples around the casting process were taken by using personal air sampler attached charcoal tube and desorbed by carbon disulfide. The identification and quantitative analysis of benzene have been performed by GC-MS and GC-FID. Calibration range of standard solutions for benzene was prepared in range from 0.1 to 2 times of TLVs concentrations($1.4{\sim}28{\mu}g/1m{\ell}$ CS2) and the limit of detection was $0.11{\pm}0.002{\mu}g/1m{\ell}$ CS2. Benzene detected in airborne was ranged in 4.0ppb~104.7ppb.

  • PDF

A Study on Antibacterial Assesment of High Efficiency Antibacterial Air Filter (고효율 항균 필터의 항균력 평가에 관한 연구)

  • 권혁구;정진도;류해열;정우성;박덕신
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.549-554
    • /
    • 2002
  • Recently, interest in hygiene has been arouse in the health care field. Consequently, Filters with antibacterial agent applied to improve air quality by sterilizing bacteria, fungi, etc. We actually installed antibacterial air filter containing 2.5wt%Ag zeolite on the air intake route to air-conditioner in passenger cu, and evaluated filter's performance on antibacterial effect. By the microbe liquid spattering method, we found that the antibacterial air filter has notably sufficient antibacterial efficiency against standard strains and wild type strains. Antibacterial effect was observed at whole area of filter media by zone of inhibition test. The evaluation of microbe quantity was conducted through mixing dilution plate culture method. In comparison with ordinary filter, the amount of germs attached on antibacterial air filters was larger. The amount of germs attached on ordinary filters was very small since ordinary filters contained less dust. In comparison in antibacterial air filter with thickness, the amount of germs attached on 9mm filter was smaller than that of on 6mm filter. i.e. thicker filter, superior efficiency.

  • PDF

Characteristics of Rainfall Protection for Stacks (굴뚝의 우수유입방지 특성)

  • Kim, Jong-Chul;Kim, Tae-Hyeung
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.18-31
    • /
    • 2000
  • A stack must be designed to 1) reduce or eliminate rainfall or snowfall into a industrial exhaust system, 2) minimize a resistance to flow, 3) maximize the vertical dispersion of the contaminated air and 4) minimize maintenance. The weather cone stacks and the elbow-type stacks are very popular in Korea. But they add some resistance to the exhaust system resulting in reduction of air flow rate, but also deflect the noxious contaminants downward in undiluted form. To solve these problems, ACGIH (American Conference of Governmental Industrial Hygienists) suggested the vertical discharge stack with concentric space between the upper stack with larger diameter and the lower stack with smaller diameter. The preliminary test showed that the vertical discharge stacks did not have the good rainfall protection. The reversed cone were newly devised to satisfy the requirements for the good stack. Subsequently, the amount of rain being penetrated through the stacks was measured while the stacks were simultaneously and naturally exposed to rain in the same area outside. Test results indicate that none of the stacks tested completely exclude rain. The efficiency of rainfall protection and the pressure loss coefficient were compared. The temporary conclusion was reached to the point that the reversed cone stack is the best one. Further research is underway.

  • PDF

Occupational Exposure to Chemicals for Workers and Levels of Airborne Chemicals in Hairdressing Salon (미용실 작업자의 화학물질에 대한 직업적인 노출과 실내공기오염 수준)

  • Yun, Jung Soon;Han, Don-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.4
    • /
    • pp.375-384
    • /
    • 2006
  • Hairdressers may be exposed to many chemicals from hair dye, permanent, shampoo, hair spray and so on. The study was conducted to evaluate occupational exposure to 8 chemicals (isopropanol, ethanol, xylene, toluene, ethylbenzene, acetone, ammonia and formaldehyde) for workers and levels of these materials in airborne of a hairdressing salon. Since compared to ACGIH TLVs these 8 chemicals were very low, it is thought that there has no problem to occupational exposure to these chemicals. Even if hairdressing salon is not enforced on Korean Standards for Indoor Air Quality, level of TOVC was thought to be below the standards. At the aspect of indoor air quality formaldehyde needs to be controlled in the future. The results imply that emission of isopropanol, ethanol, acetone and ammonia are related with hairdressing job, but emission of xylene, toluene and ehtylbenzene is more related with traditional indoor air pollution than hairdressing job. Sources of formaldehyde is thought to be little related with hairdressing job. HVAC system was a little effective on general ventilation.