The Number and Distribution of Bacteria falling in the Air of Dental Clinics

치과의원 공기중의 공중낙하세균수와 세균분포

  • Jang, Gye-won (Department of Dental Hygiene, Jinju Health College) ;
  • Kang, Yong-ju (Department of Dental Hygiene, Jinju Health College)
  • 장계원 (진주보건대학 치위생과) ;
  • 강용주 (진주보건대학 치위생과)
  • Received : 2004.06.01
  • Accepted : 2004.06.10
  • Published : 2004.06.30

Abstract

The purpose of this study was to investigate the distribution of microorganisms and the degree of contamination in the air of the dental clinics and to offer basic data as to the contamination of medical equipment and the prevention of the clinics. With this in mind, the researcher gathered air samples from the waiting rooms and medical offices of nine dental clinics in the city of J, South Korea with the use of a method of natural inattention and an air sampler and cultivated the samples on the plain table and drew from it bacteria falling and separated and sorted out the colony with the help of ATB and detected the distribution of the germs. The results are following, The number of bacteria falling in the air of the dental clinics was less than 10(CFU/Plate) with the exception of one dental clinic. This implies that they fit in with standards for hygiene. The number of bacteria falling in the air of the medical offices was less than 10(CFU/Plate) with the exception of one dental clinic. This implies that they fit in with standards for hygiene. The survey on the detection of staph. aureus reveals that all the dental clinics with the exception of B dental clinic proving to be positive had non-pathogenic staphylococci detected. The survey on the detection of pathogenic gram negative bacilli indicates that all the dental clinics but one were none detected. The survey on the distribution of germs shows that germs in 7 out of 9 dental clinics were none detected, and that they in four out of 9 waiting rooms were none detected. All the germs detected in the others were mostly non-pathogenic. The study shows that all the subject dental clinics but one were hygienically controlled and that there was a difference in accordance with cleaning and sterilization. This means that dental clinics should be equipped with systematic programs for cleaning and sterilization designed to prevent infection.

치과 진료실은 진료의 특성상 환자의 혈액과 타액 내에 있는 다양한 종류의 미생물에 노출되며, 진료 중 튀거나 에어로졸의 형태로 진료인과 환자의 신체 그리고 사용하는 모든 기구와 장비의 표면을 오염시키며 구강질병의 감염 가능성이 높아 치과영역의 교차감염에 관한 관심이 높다. 따라서 치과 진료실의 공기 중 미생물 분포와 오염정도를 조사하고 치과 진료기구의 오염과 치과 진료실의 감연방지에 대한 기초자료를 제공하고자 J시 9개 치과의원의 대기실과 진료실 공기를 자연방치법과 air sampler를 사용하여 공기시료를 채취하고 평판에 배양하여 공중낙하세균을 산출하고 생성된 집락을 세균 자동 동정기(ATB)로 분리 동정하여 세균의 분포를 검색한 결과는 다음과 같다. 1. 치과의원 환자 대기실 공기 중의 공중낙하 세균수는 자연방치법의 경우 1개 치과의원을 제외하고는 모두 10(CFU/Plate)이하여서 청결기준에 적합하였다. 2. 치과의원 진료실 공기 중의 공중낙하 세균수는 자연방치법의 경우 1개 치과의원을 제외하고는 모두 10(CFU/Plate)이하여서 청결기준에 적합하였다. 3. 황색포도상구균(Stapylococcus aureus) 검색결과는 1개 치과의원 만이 양성이었고 모두 비병원성 포도상 구균이 검출되었다. 4. 병원성 그람 음성간균의 검색결과는 1개 치과의원을 제외하고는 모두 검출되지 않았다. 5. 세균의 분포검사는 진료실의 경우 9개 치과의원 중 7개 치과의원에서 세균이 검출되지 않았고, 환자 대기실의 경우 4개 치과의원에서 세균이 검출되지 않았다. 또한 검출된 의원의 균주도 대부분 비병원균이었다. 이상과 같은 결과로 볼 때 J시 연구 선정 치과의원의 공기는 1개 치과의원을 제외하고 모두 위생적으로 관리하고 있음을 유추할 수 있었으나, 청소와 살균여부에 따라 증감을 보였기에 감염예방을 위한 체계적인 치과의원의 공기청정 및 살균관리 프로그램이 필요함을 시사하였다.

Keywords