• Title/Summary/Keyword: Air Hygiene

Search Result 410, Processing Time 0.033 seconds

The relationship between dental hygiene problems and dental hygiene planning according to oral health status (구강건강상태에 따른 치위생문제와 치위생계획의 연관성)

  • Kang, Hyun-Kyung;Kim, Yu-Rin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.18 no.5
    • /
    • pp.665-674
    • /
    • 2018
  • Objective: The purpose of this study was to reduce the burden on dental hygienists in performing dental hygiene processes in the clinic. This study systematically analyzed dental hygiene problems and dental hygiene planning according to the oral condition of patients by applying an oral health care program based on the dental hygiene process. Methods: This study analyzed influential factors of 17 dental hygiene problems and 12 dental hygiene plans according to the oral health index and charts of 185 patients. This study was approved by the Institutional Review Board (IRB No. 1041449-201801-HR-003) of Silla University. The frequency of dental hygiene problems and dental hygiene planning was analyzed and correlations among the oral health index, dental hygiene problems, and dental hygiene planning were analyzed. Results: The higher the bleeding on probing score was, the more scaling was planned. The higher the calculus rate was, the more air-jet and jaw joint disorder prevention education was planned. The higher the O'Leary index was, the more dietary education and air-jet was planned. The higher the Simplified Oral Hygiene Index was, the more air-jet and jaw joint disorder prevention education was planned. The higher the Periodontal Screening and Recording index was, the more scaling and professional tooth cleaning was planned (p<0.05). Conclusions: The burden of oral preventive duties on dental hygienists will be minimized by systematically establishing problems and planning of dental hygiene according to patients' oral health index scores. Therefore, it is expected that dental hygienist can actively use the dental hygiene process in oral health care programs.

A Proposal for a Predictive Model for the Number of Patients with Periodontitis Exposed to Particulate Matter and Atmospheric Factors Using Deep Learning

  • Septika Prismasari;Kyuseok Kim;Hye Young Mun;Jung Yun Kang
    • Journal of dental hygiene science
    • /
    • v.24 no.1
    • /
    • pp.22-28
    • /
    • 2024
  • Background: Particulate matter (PM) has been extensively observed due to its negative association with human health. Previous research revealed the possible negative effect of air pollutant exposure on oral health. However, the predictive model between air pollutant exposure and the prevalence of periodontitis has not been observed yet. Therefore, this study aims to propose a predictive model for the number of patients with periodontitis exposed to PM and atmospheric factors in South Korea using deep learning. Methods: This study is a retrospective cohort study utilizing secondary data from the Korean Statistical Information Service and the Health Insurance Review and Assessment database for air pollution and the number of patients with periodontitis, respectively. Data from 2015 to 2022 were collected and consolidated every month, organized by region. Following data matching and management, the deep neural networks (DNN) model was applied, and the mean absolute percentage error (MAPE) value was calculated to ensure the accuracy of the model. Results: As we evaluated the DNN model with MAPE, the multivariate model of air pollution including exposure to PM2.5, PM10, and other atmospheric factors predict approximately 85% of the number of patients with periodontitis. The MAPE value ranged from 12.85 to 17.10 (mean±standard deviation=14.12±1.30), indicating a commendable level of accuracy. Conclusion: In this study, the predictive model for the number of patients with periodontitis is developed based on air pollution, including exposure to PM2.5, PM10, and other atmospheric factors. Additionally, various relevant factors are incorporated into the developed predictive model to elucidate specific causal relationships. It is anticipated that future research will lead to the development of a more accurate model for predicting the number of patients with periodontitis.

Isolation and Identification of Bacteria from Air Conditioners and its Hygiene (에어컨내 세균의 분리, 동정 및 위생)

  • Hong, Seong-Gap;Jeong, Yong-Tae;Cheon, Gyeong-Ho;Baek, Sun-Yeong
    • Korean Journal of Microbiology
    • /
    • v.39 no.4
    • /
    • pp.283-287
    • /
    • 2003
  • This study was performed to identify the microorganisms from air conditioners and to investigate hygiene management on air conditioners. Eight species of bacteria were isolated and identified from twenty samples of coolers in air conditioners; Pantoea sp., Bacillus circulans, Bacillus pumilus, Corynebacterium, Flavimonas oryzihabitans, Ochrobacterum anthropi, Micrococcus sp., and non fermented bacilli (NFB). One thousand and three hundreds twenty-two persons who used air conditioners in their houses were investigated about the state of hygiene management in their air conditioners. One thousand and one hundred thirty eight persons (86%) of the total investigated persons ventilated their air conditioners and 1,128 persons (85%) of them cleaned their air conditioners. However, 864 persons (66%) of them did not clean filters and 1,089 persons (82%) did not clean the heat exchangers, both of which air conditioners could be easily contaminated by microorganisms. From these results, we could conclude that the contaminants, bacteria as mentioned the above, in air conditioners could cause human disease such as respiratory infections if the number of bacteria increase in air conditioners. Thus, the removal of contaminants and the improved hygiene of the air conditioners can prevent human diseases caused by the released bacteria during the use of air conditioners.

The satisfaction and subjective symptom level by indoor air quality in dental parlor in Capital and Jeon-nam area (일부지역 치과위생사의 치과진료실 실내공기질에 대한 만족도 및 자각증상 비교)

  • Choi, Mi-Suk
    • Journal of Korean society of Dental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.405-417
    • /
    • 2011
  • Objectives : A precedent research has documented that indoor air pollution is closely associated with increased the risk of symptom and decreased in job satisfaction. This study was conducted in an effort to assess the relationship of indoor air quality to self-perceived symptom and satisfied with working environment. Methods : This research is based on self-filling survey which 393 dental hygienists who work in seoul and Jeon-nam area participated on October 2010 through January 2011. This survey was compared and analyzed about the level of satisfaction and subjective symptom by the indoor air quality that dental office's working environment. Results : The result of satisfaction degree of hospital working environment was pretty low about office air. Most people mentioned that they were sore and dull all over the back, shoulder, and neck. Also, they were drowsy and exhausted in work place. Conclusions : In conclusion, it is need to improve their quality of life and mental health by developing proper air conditioning system and using one in their work place.

Development of an Sampling Tube for Organic Solvents and Study on the Adsorption Capacity of the Activated Charcoal (유기용제용 시료채취기 개발을 위한 활성탄 성능검정에 관한 연구)

  • Bai, Ya Soung;Park, Doo Young;Lim, Dai Soung;Park, Byung Moo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.8-18
    • /
    • 2005
  • Adsorption capacity for the charcoal were tasted in this study to verify the performance of them for the use of the sampling media in industrial hygiene field. Two set of experiments were conducted. The first experiment was to test performance of the tested charcoal tube that were assembled in the laboratory with the use of the GR grade charcoal. The other tests were investigate the adsorption capacity of the charcoal tested in this study and charcoals embedded in the commercial charcoal tubes. Known air concentration samples for benzene, toluene, and o-xylene were prepared by the dynamic chamber. 1. At low air concentration levels (0.1${\times}$TLV), there was no significant differences between the tested charcoal tubes and the SKC charcoal tubes. This implies that there is no defect with the adsorption capacity of the charcoal. 2. At high concentration with 60 minutes sampling, the breakthrough were found only in the tested charcoal while no breakthrough were shown in the SKC charcoal. 3. From the breakthrough tests for the charcoal, the micropore volume(Wo) were calculated by the curve fitting with the use of Dubinin/Radushkevich(D/R) adsorption isotherm equation. The calculated values were 0.687cc/g for SKC, 0.504cc/g for Sensidyne, and 0.419cc/g for the tested charcoal(Aldrich). 4. Adsorption capacities were obtained from the isotherm curves shown adsorption capacities at several levels of the challenge concentration. All range of the air concentration concerned in industrial hygiene, the SKC charcoal showed approximately two times of adsorption capacity compared to the tested charcoal.

The Effect of Ventilation and Concentration of Indoor Air Quality at Indoor Parking Lots (실내주차장의 실내공기질 농도특성 및 환기에 의한 저감효과)

  • Park, Jeong-Ho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.4
    • /
    • pp.241-247
    • /
    • 2010
  • Recently, indoor air quality (IAQ) has been one of the major concerns of people. Indoor parking lots are subject to be exposed to high concentrations of air pollutants emitted from vehicles. This study was performed to investigate indoor air quality (IAQ) at indoor parking lots. Sampling sites were selected 5 indoor parking lots. Target indoor air quality parameters include a number of criteria pollutants such PM$_{10}$, CO, CO$_2$, and HCHO. In addition, a variation of IAQ according to ventilation system operating was measured at C site (underground parking lot). In general, all pollutants were maintained below indoor air quality maintenance standards. The indoor air quality at indoor parking lots was affected by the availability of the ventilation facility and their operation frequency. At the underground parking lot (C site) with ventilation system, TVOC concentration according to ventilation system operating were found to be lower operating (488.2 ${\mu}g/m^3$) than non-operating (1,401.2 ${\mu}g/m^3$).

Changes in Air Temperature and Its Relation to Ambulance Transports Due to Heat Stroke in All 47 Prefectures of Japan

  • Murakami, Shoko;Miyatake, Nobuyuki;Sakano, Noriko
    • Journal of Preventive Medicine and Public Health
    • /
    • v.45 no.5
    • /
    • pp.309-315
    • /
    • 2012
  • Objectives: Changes in air temperature and its relation to ambulance transports due to heat stroke in all 47 prefectures, in Japan were evaluated. Methods: Data on air temperature were obtained from the Japanese Meteorological Agency. Data on ambulance transports due to heat stroke was directly obtained from the Fire and Disaster Management Agency, Japan. We also used the number of deaths due to heat stroke from the Ministry of Health, Labour and Welfare, Japan, and population data from the Ministry of Internal Affairs and Communications. Chronological changes in parameters of air temperature were analyzed. In addition, the relation between air temperature and ambulance transports due to heat stroke in August 2010 was also evaluated by using an ecological study. Results: Positive and significant changes in the parameters of air temperature that is, the mean air temperature, mean of the highest air temperature, and mean of the lowest air temperature were noted in all 47 prefectures. In addition, changes in air temperature were accelerated when adjusted for observation years. Ambulance transports due to heat stroke was significantly correlated with air temperature in the ecological study. The highest air temperature was significantly linked to ambulance transports due to heat stroke, especially in elderly subjects. Conclusions: Global warming was demonstrated in all 47 prefectures in Japan. In addition, the higher air temperature was closely associated with higher ambulance transports due to heat stroke in Japan.

Analysis of Air Quality and the Management Plan for Exposure to Hazardous Substances in the Garage of a Fire Station (소방청사 차고지 공기질 분석 및 유해물질 노출 관리 방안)

  • Park, Je-Seop;Han, Dong-Hun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.4
    • /
    • pp.394-404
    • /
    • 2020
  • Objectives: The aims of this study are to derive the characteristics of diesel exhaust gas emissions generated during vehicle checking in the garage of fire stations and of the related improvement plans for proper air quality management. Methods: The researcher measured changes in the air quality inside garages according to the operating conditions of the exhaust facility and before and after vehicle checking at three fire stations. Results: During the checking of fire engines, a large volume of hazardous substances exceeding management standards were generated, and improvement of the discharge facilities was required for proper air quality management. Conclusions: It is necessary to study the hazard evaluation of firefighters' exposure to exhaust gas, to operate exhaust gas ventilation facilities, and to prepare technical standards for proper indoor air quality management.

Knowledge about hepatitis B among dental hygiene students in one college (일부 M지역 치위생과 학생들의 B형간염에 대한 지식도 조사)

  • Park, Ji-Hye;Kim, Hye-Young;Kwun, Hyeon-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.9 no.1
    • /
    • pp.207-215
    • /
    • 2009
  • The purpose of this study was to evaluate knowledge and differences about hepatitis B among dental hygiene students in Masan university. The study surveyed by means of self-administered questionnaire consisted 193 of them. The converted score of knowledge of hepatitis B among 1st and 2nd grade students was 61.3(${\pm}22.4$) and 73.1(${\pm}18.3$) point respectively if 100 point for all statements were correctly answered. They have a good understanding of knowledge of hepatitis B except air bone infection and transmission by fomites. There is no differences of knowledge about hepatitis B according to socio-economic factor like father's education, mother's education and income. In conclusion, dental hygiene students should be educated more about hepatitis B.

  • PDF