• Title/Summary/Keyword: Air Gap Winding

Search Result 104, Processing Time 0.024 seconds

Development of Online Monitoring System for Induction Motors (유도전동기 온라인 감시진단 시스템 개발)

  • Kim, Ki-Bum;Youn, Young-Woo;Hwang, Don-Ha;Sun, Jong-Ho;Jung, Tea-Uk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.23-30
    • /
    • 2014
  • This paper presents an on-line diagnosis system for identifying health and faulted conditions in squirrel-cage induction motors using stator current, temperature, and partial discharge signals. The proposed diagnosis system can diagnose induction motor faults such as broken rotor bars, air-gap eccentricities, stator winding insulations, and bearing faults. Experimental results obtained from induction motors show that the proposed system is capable of detecting induction motor faults.

A Study on the Leakage Inductance in Current Transformers by 3D Integral Methods (3차원 적분법을 이용한 변류기의 누설 인덕턴스에 대한 연구)

  • Lee, Hee-Kab;Park, Yong-Pil;Lee, Sung-Ill
    • Proceedings of the KIEE Conference
    • /
    • 2002.11a
    • /
    • pp.116-118
    • /
    • 2002
  • This paper presents leakage magnetic field and leakage inductance calculations in current transformer by means of 3-D Integral methods. From the distribution diagram of leakage magnetic flux to be analyzed using program called TRACAL 3, it confirms a parallel to the winding axis direction of the leakage flux lines in the air gap between the windings. The leakage inductances $L_{r1}\;and\;L_{r2}$ of the primary and secondary windings were calculated, their values are 4.23 mH and 0.49 mH, respectively. They are also similar to the measured values of the leakage inductances for the experimental verification, 4.06 mH and 0.47 mH.

  • PDF

A Study on the EMF harmonics of Salient Synchronous Generator (돌극 동기발전기의 역기전력 고조파 연구)

  • Park, Jeong-Tae;Kim, Chang-Wook;Kim, Keun-Ung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1050-1052
    • /
    • 2005
  • In this paper, air gap flux density is calculated by permeance model which can consider the effects of the stator slot and the salient pole shape of the salient synchronous generator. No load Electro-motive force(EMF) of the short-pitched and distributed stator winding is also calculated. Therefore, it's very convenient to calculate the THD of the no load EMF for the user's request, in the first design state.

  • PDF

Numerical Analysis for Characterization of Single Phase Induction Motors by using Circuit Equations Coupled with Magnetic Field Distribution

  • Kim, Young Sun;Lee, Dong Yoon
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.255-259
    • /
    • 2013
  • In this paper a new coupling method for efficient and simple analysis of single phase induction motor is presented. The circuit representation of both the stator winding and each conducting rotor loop (composed of rotor bar and end ring segment) is used in conjunction with the distribution of magnetic flux linkage instead of inductance matrix. The flux linkage is calculated using air-gap flux density distributions driven by unit currents in the stator windings and rotor bars. The field distribution of one turn of a coil is calculated by FEM and the result is used to calculate total flux linkage by employing a coordinate transformation. The numerical results give good agreement with prior literature. The method is particularly effective in analyzing the effect of the number of rotor bars.

Construction of Current Sensor Using Hall Sensor and Magnetic Core for the Electric and Hybrid Vehicle (홀소자와 자기코어를 이용한 하이브리드 및 전기자동차용 전류센서 제작)

  • Yeon, Kyoheum;Kim, Sidong;Son, Derac
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.2
    • /
    • pp.49-53
    • /
    • 2013
  • A current sensor is one of important component which is used for the electrical current measurement during charge and discharge of the battery, and monitoring system of the motor controller in the electric and hybrid vehicle. In this study, we have developed an open loop type current sensor using GaAs Hall sensor and magnetic core has an air gap. The Hall sensor detect magnetic field produced by the current to be measured. The 3 mm air gap core was made by HGO electrical steel sheets after slitting, winding, annealing, molding, and cutting. Developed current sensor shows 0.03 % linearity within DC current range from -400 A to +400 A. Operating temperature range was extended to the range of $-40{\sim}105^{\circ}C$ using temperature compensating electronic circuit. To Improve frequency bandwidth limit due to the air flux of PCB (Printed Circuit Board) and Hall sensor, We employed an air flux compensating loop near Hall sensor or on PCB. Frequency bandwidth of the sensor was 100 kHz when we applied sine wave current of $40A{\cdot}turn$ in the frequency range from 100 Hz to 100 kHz. For the dynamic response time measurement, 5 kHz square wave current of $40A{\cdot}turn$ was applied to the sensor. Response time was calculated time reach to 90 % of saturation value and smaller than $2{\mu}s$.

Study on Machine Characteristics in Interior Permanent Magnet Synchronous Motor According to Pole/Slot Combinations with Radial Vibration Force Consideration (극수/슬롯수 조합에 따른 Radial Vibration Force 고려한 매입자석 동기모터 특성 연구)

  • Fang, Liang;Lee, Su-Jin;Lee, Byeong-Hwa;Hong, Jung-Pyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.949-954
    • /
    • 2011
  • This paper presents a comparative study on motor characteristics with specific consideration of radial vibration force in interior permanent magnet synchronous motors (IPMSM) according to pole/slot combinations. Three IPMSM models, 16-pole/15-slot design, 16-pole/18-slot design and 16-pole/24-slot design are built, in which 16-pole/15-slot and 16-pole/18-slot designs provide high winding factor and 16-pole/24-slot design is known as a general pole/slot combination. By coupling finite element analysis (FEA) with equivalent circuit method, motor characteristics, back electro-motive force (Back-EMF), inductances, cogging torque, etc. as well as machine output performances are analyzed and compared. The radial vibration force (RVF) distribution in air gap causing stator vibration and noise is interested. It is expected that this study help with appropriate choice of pole/slot combination in IPMSM design.

Fabrication and Characteristics of 30〔kVA〕 Superconducting Generator (30(kVA) 초전도발전기 제작 및 특성)

  • ;;;;;;;I. Muta;I. Hoshino
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.32-38
    • /
    • 2001
  • A 30[kVA] superconducting generator (SCG) is built and tested at Korea Electrotechnology Research Institute (KERI) in Korea. This superconducting generator has an air-gap winding instead of the typical steel teeth structure. The rotor has 4 field coils of race-track type with NbTi superconducting wired. The rotor is composed of two dampers and a liquid helium composed of two dampers and a liquid helium container in which the field poles reside. The space between the outermost damper and the container is vacuum insulated. A ferrofluid seal is used between the stationary part connected to the couping and the rotor. A helium transfer coupling(HTC) has 3 passages of the recovered heilum gas and a gas flow control system. The open circuit test and sustained short circuit test are preformed to obtain the open circuit characteristics (OCC) and short circuit characteristics (SCC) Also. the test results usder the light load (up to 3.6[kW]) are given. The structure, manufacturing and basis test of the 30[kVA]SCG are discussed.

  • PDF

Transient Characteristic Analysis of Damper in Superconducting Synchronous Generator by the Compensated 2D Analysis Model (보정된 2차원 해석모델에 의한 초전도 동기발전기의 댐퍼 과도특성 해석)

  • Chun, Yon-Do;Lee, Hyung-Woo;Lee, Ju;Hong, Jung-Pyo;Kwon, Young-Kil;Ryu, Kang-Sik
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.2
    • /
    • pp.93-101
    • /
    • 2000
  • This paper presents a novel method for the transient of eddy currents in the dampers of a super-conducting synchronous generator(SCG). The method proposes a 2-D corrected model which takes into account the influence of leakage fluxes of the field winding ends by increasing the effective air gap in order to consider the high precision of the analysis for the conventional 2-D model. The electromagnetic fields for the corrected model are analyzed by the time-stepping finite element method, thus the eddy currents in the dampers and electro-motive forces(EMF) in the stator windings are calculated. As the results, it is proved the presented method is comparatively accurate by comparing measured phase EMF values and the simulation ones, where about 6.4% error at the maximum value of EMF is occurred between them.

  • PDF

Analysis of Permanent Magnet Synchronous Generator for Vortex Induced Vibration Hydrokinetic Energy Applications Based on Analytical Magnetic Field Calculations

  • Choi, Jang-Young;Shin, Hyun-Jae;Choi, Jong-Su;Hong, Sup;Yeu, Tae-Kyeong;Kim, Hyung-Woo
    • Journal of Magnetics
    • /
    • v.17 no.1
    • /
    • pp.19-26
    • /
    • 2012
  • This paper deals with the performance analysis and estimation of the electrical parameters of a permanent magnet synchronous generator (PMSG) for hydrokinetic energy conversion applications using vortex induced vibration (VIV). The analytical solutions for the magnetic fields produced by permanent magnets (PMs) and stator winding currents are obtained using a 2D polar coordinate system and a magnetic vector potential. An analytical expression for the 2D permeance is also derived, which takes into account stator skew effects. Based on these magnetic field solutions and the 2D permeance function, electrical circuit parameters such as the backemf constant and the air-gap inductance are obtained analytically. The performances of the PMSG are investigated using the estimated electrical circuit parameters and an equivalent circuit (EC). All analytical results are validated extensively using 2D finite element (FE) analyses. Experimental measurements for parameters such as the back-emf and inductance are also presented to confirm the analyses.

30kVA Superconducting Generator Development : Design and Performance Test (30kVA 초전도전기 개발(II) ; 설계 및 성능평가)

  • Baik, S.K.;Sohn, M.H.;Kwon, Y..K.;Ko, R.K.;Lee, E.Y.;Ryu, K.S.;Park, D.Y.;Kim, Y.J.;Ahn, J.B.;Kim, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.232-234
    • /
    • 1999
  • A 30kVA superconducting generator (S.G.) has been designed, developed and successfully tested in KERI before the end of last year. The design is based on 2-dimensional electromagnetic field analysis of cylindrical coordinate. The field winding of rotor has been wound with superconducting wire of Nb-Ti alloy and tested after assembled with other rotor components. The stator has air-gap type armature windings which allow higher terminal voltage and more sinusoidal voltage waveform than conventional iron cored machines. Steady-state open & short-circuit test and lamp load test have been conducted also. The results of tests are given in this paper and compared with design quantities. Moreover the cooling scheme and characteristics of test system is included.

  • PDF