• Title/Summary/Keyword: Air Flow Control

Search Result 1,022, Processing Time 0.028 seconds

Construction of Map for Transient Condition of a Sl Engine and Refinement of Intake Air Model & Fuel Model (가솔린 엔진의 비정상 상태에 대한 Map 구성과 공기 및 연료 모델 개선)

  • 심연섭;강태성;강승표;고상근
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.1-8
    • /
    • 2002
  • For gasoline engines, a three-way catalytic converter that has the maximum efficiency at stoichiometric air/fuel ratio is used to clean up the exhaust gas. So a precise air/fuel ratio control is necessary to maximize the catalytic conversion efficiency, For a transient condition, a fred-forward air/fuel ratio control method that estimates the air mass inducted into a cylinder is being used. In this study, a fuel injection map that makes an accurate air/fuel ratio control possible was constructed for the very same transient condition. For the same condition above, intake air model and fuel model were refined so that fuel injection values based on air mass through a throttle valve and intake manifold pressure are equal to the map values.

Study on the Passive Shock/Boundary Layer Interaction Control in Transonic Moist Air Flow (습공기 유동에서 발생하는 충격파와 경계층 간섭의 피동제어에 관한 연구)

  • Baek, Seung-Cheol;Kwon, Soon-Bum;Kim, Heuy-Dong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.8
    • /
    • pp.21-29
    • /
    • 2002
  • In the present study, a passive control method, using a porous wall and cavity system, is applied to the shock wave/boundary layer interactions in transonic moist air flow. The two-dimensional, unsteady, compressible, Navier-Stokes equations, which are fully coupled with a droplet growth equation, are solved by the third-order MUSCL type TVD finite difference scheme. Baldwin-Lomax model is employed to close the governing equations. In order to investigate the effectiveness of the present control method, the total pressure loss of the flow and the time-dependent behaviour of shock motions are analyzed in detail. The computed results show that the present passive control method considerably reduces the total pressure losses due to the shock wave/boundary layer interaction in transonic moist air flow and suppresses the unsteady shock wave motions over the airfoil as well. It is also found that the location of the porous ventilation significantly affects the control effectiveness.

A Study on the Frequency Response Characteristics of High Response Flow Control Servo Valve (고 응답 유량제어 서보밸브의 주파수 응답특성에 관한 연구)

  • 서종수;신유식;지명국;전영흥;정효민;정한식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.480-488
    • /
    • 2003
  • The purpose of this research Is to derive the principal design parameters governing the dynamic characteristics of the high response flow control servo valve. For this purpose, a numerical modeling of the servo valve system and a parameter sensitivity analysis to a frequency response characteristics was peformed. As a result of these analysis, a basis for improvement of a dynamic characteristics of servo valve was arranged.

Auto Flow Rate Regulating System Synchronized with Room Control (난방시 실별 연동형 세대자동유량제어 시스템)

  • Kim, Young-Kyun;Kim, Nam-Gun;Seo, Bum-Suk
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.77-82
    • /
    • 2009
  • If we can supply accurate minute flow rate to the households, we can solve many problems that are occurring in consequences of uncontrolled flow rate for the households. Therefore, this paper presents an innovative solution to the source of the problems by illustrating how we can control the flow rate to the household. This paper proves such problems even can be solved in a case when there is a room turned off the heating.

  • PDF

A Study on the Implementation of Air flow Control System using Profibus and Inverter (Profibus와 인버터를 이용한 공기량 제어시스템 구현)

  • 문용선;이명복;김동권;정철호
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.10
    • /
    • pp.808-815
    • /
    • 2003
  • Fieldbus technology is having a massive impact on the development of faster, smarter and less expensive industrial networking systems. However, there have been a few of practically applied cases and channels for obtaining technical advices. Moreover, the users in the industry don't trust the Fieldbus technology like they didn't trust PLC control system in 1970s. Therefore, in this paper, Air flow control system is constructed by Fieldbus technologies, Profibus and Inverter that controls the motor speed. With the features of the motor control, the amount of electric power consumption by the speed control of motor is measured by the constructed control system. From this measured result, the effectiveness of the airflow control system and Feasibility to the practical industry field is demonstrated To improve the confidence of Fieldbus technology, practically embodied cases and technical methods are presented.

Influence of Control Variables on the Aerobic Biodegradation Performance in Bin Composting System (회분식 퇴비화 시스템에서 제어변수가 호기성 분해성능에 미치는 영향)

  • 박금주;홍지형
    • Journal of Biosystems Engineering
    • /
    • v.24 no.4
    • /
    • pp.359-364
    • /
    • 1999
  • A theoretical model was developed to evaluate the influence of control variables on the composting performance in a bin composting system. The model was verified using pilot scale composting system. Simulation of the composting temperature according to air flow rate and composting bin size was conducted using the mathematical model. High composting temperature above 55$^{\circ}C$ needed to kill a pathogen was maintained for longer periods as the air flow rate was lower and the bin size was larger. Optimum air flow rate was 0.77L/min/kg.DM for the experimental pilot scale bin system. The size of composting bin should be large enough to maintain the higher composting temperature for required periods.

  • PDF

Development of Pressure Differential Smoke Control System for Separating the Leakage Air Flow and the Supplementary Air Flow (분리급기형 급기가압 제연시스템 개발)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.310-313
    • /
    • 2011
  • 국내에서 고층건물의 제연시스템으로 급기가압 제연시스템이 일반적으로 사용되고 있는데, 기존의 급기가압 제연시스템의 설계방안과 같이 한개의 급기풍도를 통해 누설량과 보충량이 동시에 공급될 경우에는 부속실과 옥내간에 형성되는 차압이 설계기준에 미달하거나 과압이 될 가능성이 매우 높아져서 급기가압 제연시스템의 설치목적을 달성하지 못할 수 있다. 이에 대한 개선방안으로 본 연구에서는 누설량의 공급과 보충량의 공급을 각기 다른 유로를 통해 수행하는 방안 및 장치구성을 제시함으로서 고층건물에서 화재 발생시 안전한 피난환경을 제공하고자 한다.

  • PDF

Analysis of PI air-fuel ratio feedback control system (비례적분 방식의 피드백 공연비 콘트롤 시스템 해석)

  • 이대영;박경석;노승탁;김응서;고상근
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.73-80
    • /
    • 1991
  • Air/fuel ratio control system for gasoline engines has been analyzed to determine the control gain of the system. In this analysis the engine is modelled to be a simple time delaying element and the ramp-and-jump method is used to control air/fuel ratio. The result shows that it is necessary to measure the air flow rate accurately to enhance the control performance. And also it is shown that the control gain must be determined in some bounded region to meet the fast dynamic response and high catalyst conversion efficiency together.

  • PDF

A Numerical Study of the Air Quality Inside Automobiles According to the HVAC System Operating Conditions (HVAC 작동특성에 따른 자동차 실내 공기질 평가에 관한 수치해석적 연구)

  • Yoon, Seonghyun;Seo, Jinwon;Choi, Yunho
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.3
    • /
    • pp.299-309
    • /
    • 2014
  • When using an automotive heating, ventilation, and air conditioning (HVAC) system, we can obtain fresh outside air while maintaining the interior vehicle temperature. In this study, a correction equation considering experimental data for automotive indoor air leakage is defined to simulate the ratio of fresh air to recirculated air in the automobile cabin. With this correction equation, numerical results are compared with experimental data and validated. The $CO_2$ concentration in the automotive cabin is evaluated by considering various boarding conditions and mass flow rates of the HVAC system. The $CO_2$ concentration model derived in this study is expected to be used to control the effective air conditioning and become a basic research tool for automotive air quality control system development.

A Numerical Study on Effects of Flow Analysis with Flow Control Valve on Turbine of OWC Type Wave Power Generator (유량 조절 밸브가 탑재된 진동수주형 파력발전장치의 터빈 내 유동해석을 위한 수치해석 연구)

  • Ro, Kyoung-Chul;Oh, Jae-Won;Kim, Gil-won;Lee, Jung-Hee
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.801-808
    • /
    • 2021
  • In this paper, a numerical analysis was conducted on the effect of the flow control valve of a oscillation water column(OWC) type wave power generator turbine. The OWC wave power turbine operates with compressed air in the air chamber according to the change of wave height. When the wave height changes rapidly, a flow control valve is required due to overload of the turbine and reduced efficiency. Therefore, in this paper, a flow control valve with an opening angle of 60 degrees was installed in the front of the turbine, and the pressure drop, torque, and overall performance were calculated according to the change of turbine RPM and flow rate of turbine inlet. In conclusion, the flow control valve with an opening angle of 60 degrees affects when the turbine rotates at low rotation and the inlet flow rate is large. But it does not have a significant effect on overall turbine performance and it is necessary to find the optimal angle in the future works.