DEVELOPMENT OF INTERFACIAL AREA TRANSPORT EQUATION

  • ISHII MAMORU;KIM SEUNGJIN;KELLY JOSEPH
    • Nuclear Engineering and Technology
    • /
    • 제37권6호
    • /
    • pp.525-536
    • /
    • 2005
  • The interfacial area transport equation dynamically models the changes in interfacial structures along the flow field by mechanistically modeling the creation and destruction of dispersed phase. Hence, when employed in the numerical thermal-hydraulic system analysis codes, it eliminates artificial bifurcations stemming from the use of the static flow regime transition criteria. Accounting for the substantial differences in the transport mechanism for various sizes of bubbles, the transport equation is formulated for two characteristic groups of bubbles. The group 1 equation describes the transport of small-dispersed bubbles, whereas the group 2 equation describes the transport of large cap, slug or chum-turbulent bubbles. To evaluate the feasibility and reliability of interfacial area transport equation available at present, it is benchmarked by an extensive database established in various two-phase flow configurations spanning from bubbly to chum-turbulent flow regimes. The geometrical effect in interfacial area transport is examined by the data acquired in vertical fir-water two-phase flow through round pipes of various sizes and a confined flow duct, and by those acquired In vertical co-current downward air-water two-phase flow through round pipes of two different sizes.

전산 가시화를 통한 무인 항공기용 연료전지 양극 산소 유로 최적화 연구 (Optimization study on fuel cell cathode oxygen flow path for Unmanned Aerial Vehicle using computational visualization)

  • 전지아;이재준;송영수;김민수;김건우;나영승;리광훈
    • 한국가시화정보학회지
    • /
    • 제17권1호
    • /
    • pp.85-92
    • /
    • 2019
  • Numerical visualization is conducted to confirm the variation of flow characteristics and pressure drop by the shape of channels on the cathode flow path in hydrogen fuel cells for unmanned aerial vehicles(UAVs). Generally, a light-weight fan is commonly used rather than a heavy air compressor at UAVS. However, in case of blower fan, a large pressure drop in the flow path causes the blocking of the oxygen supply to the fuel cell. Therefore, the uniformity of flow inside the cathode has to be achieved by changing the shape of the cathode. The flow channel, the duct shape, and the diameter of the fan are changed to optimize the flow path. As a result, it is confirmed that the optimal flow path can decrease the velocity difference between the center and outer flow by 1.8%. However, It should be noted that the channel size can increase the pressure drop.

무창계사의 환기 시스템이 케이지 사육 육계의 초기 생산성에 미치는 영향 (Effect of Ventilating System on the Performance of Broiler Chicks in an Environmental Controlled Cage House)

  • 황보종;홍의철;이병석;배해득;이성재;조성백;김학규;김재황;박병성;송준익
    • 한국가금학회지
    • /
    • 제33권1호
    • /
    • pp.57-63
    • /
    • 2006
  • 본 연구는 신축한 무창 실험 계사의 환기 시스템이 육계의 생산성에 미치는 영향을 조사하고자 하였다. 본 실험은 신축 실험계사에서 무창 육계사의 환기 시스템이 케이지 사육 육계의 성장에 미치는 영향을 구명하고자 계사의 내부 환경을 외부와 완전히 차단하여 각종 질병 요인으로부터 계사의 내부 환경을 보호할 수 있는 무창 계사에서 실시하였다. 환경요인 중에서 제일 중요한 온도, 습도, 공기 속도가 육계의 성장에 미치는 영향에 대하여 조사하고자 2주간 실행하였으며, 실험 결과는 다음과 같다. 1. 암모니아 가스 발생량은 케이지 2단(13.7 ppm), 3단(13.5 ppm)에서는 케이지 1단(14.6 ppm)에 비하여 낮게 측정되었다. 오후에 측정한 결과 오전과 비슷한 경향이었다. 이산화탄소는 오전과 오후 케이지간 큰 차이는 없었지만 신선한 공기가 유입되는 4단 높이에서 낮은 경향이었다. 2. 공기 풍속에 있어서는 무창 계사는 상부 0.57 m/sec, 중앙 0.22 m/sec, 하부 0.04 m/sec로 각각 나타나, 계사내 적정 풍속 유지를 위한 덕트 입기구의 천공으로 인하여 계사내 전체 공간에서 공기의 유속 흐름 분포가 고르게 나타났다. 3. 증체량은 시험 전 기간동안 케이지 1에서 케이지 2, 3, 4단에서 보다 높게 나타났지만 유의적인 차이는 없었다(p>0.05). 섭취량은 시험기간 동안 전 처리구에서 유의적인 차이가 없었다(p>0.05). 사료 효율은 증체량과 마찬가지로 케이지 1에서 다른 케이지에 비해 높았으나 유의성은 나타나지 않았다. 이상의 실험 결과를 종합해 볼 때 조사대상이 된 무창 실험 계사의 온도 및 습도 환경 조절이 우수하게 나타났으며 케이지간 공기의 흐름은 원활하였다.

오존 처리가 자돈사내 공기의 질과 자돈의 성장 효율에 미치는 영향 (Effects of Ozonation of the Swine Nursery Building on Indoor Air Quality and Growth Performance of Weanling Piglets)

  • 김광위;우종화;이철영;김두환
    • Journal of Animal Science and Technology
    • /
    • 제45권6호
    • /
    • pp.1061-1066
    • /
    • 2003
  • 본 연구는 자돈사의 오존 처리가 돈사내 공기의 질과 자돈의 성장 효율에 미치는 영향을 구명하고자 수행되었다. 오존 0.03ppm 처리하거나 처리하지 않은 각 처리별 40두의 21일령 이유자돈을 암수 같은 수로 하여 2개의 돈방에 배치하고 3주 동안 사양하였으며, 3회 반복하여 실시하였다. 오존은 상업용 장치를 이용하여 자돈사 밖에서 발생시켜 관을 통하여 자돈사 건물 안으로 0.03ppm 수준으로 유입시켰다. 돈사내 유해가스 농도는 3주 사양시험 중 24시간 동안 2 시간 간격으로 측정하였다. 오존 처리에 의해 황화수소 농도는 변하지 않았으나, 오존 처리했을 때 암모니아와 이산화탄소 농도는 처리하지 않았을 때의 농도에 비해 각각 21%와 7% 감소하였다(P〈0.01). 반면 자돈의 일당증체량, 사료섭취량 및 사료요구율은 오존 처리에 의해 변하지 않았다. 이상의 결과는 자돈사내 오존 처리가 자돈의 생산 효율에는 영향을 미치지 않으나 돈사내 공기의 질을 개선시킬 수 있음을 시사한다.

항공기 가스터빈용 오일쿨러 해석을 위한 1 차원 열유동 네트워크 수치적 모델 개발 및 연구 (Numerical Study on Surface Air-Oil Heat Exchanger for Aero Gas-Turbine Engine Using One-Dimensional Flow and Thermal Network Model)

  • 김영진;김민성;하만영;민준기
    • 대한기계학회논문집B
    • /
    • 제38권11호
    • /
    • pp.915-924
    • /
    • 2014
  • 항공기용 가스터빈 엔진에 있어서, 기어 어셈블리 및 전자장비에 사용되는 오일의 냉각을 위하여 열교환기가 사용되며 이를 Surface air-oil heat exchanger (SAOHE) 라고 한다. 이 열교환기는 엔진 팬 케이싱 내부에 설치되며 기어박스 시스템 및 전자장비로부터 바이패스 덕트 후류 쪽으로 열을 소산시킨다. 본 연구의 목적은 SAOHE 의 설계를 위한 효율적인 수치해석방법을 개발하는 것이다. SAOHE 설치에 따른 핀에서의 열공력학적 성능을 평가하기 위하여 다공성 모델을 활용한 2 차원 수치해석을 수행하였고, 열교환기 성능평가에 대해 시간 및 비용적으로 효과적인 1 차원 열유동 네트워크 프로그램을 개발하였다. 이 프로그램을 이용하여 열교환기의 압력강하 및 열전달 성능을 예측하였고, 1 차원 열유동 네트워크 프로그램을 검증하기 위해 2 차원 전산해석 결과 및 실험 결과와 비교하였다.

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

장대 광산갱도내 풍관 접속 통기선풍기 최적 설치 방안연구 - 벽면과 풍관간의 이격거리 중심으로 (A Study on the Optimal Installation of Ducted Fan Ventilation System in Long Mine Airways - Focused on the Wall Separation Distance and the Gap Length between Ducts)

  • 이창우;응우엔반득
    • 터널과지하공간
    • /
    • 제27권1호
    • /
    • pp.12-25
    • /
    • 2017
  • 국내 석회석광산은 주로 자연통기에 의존하고 있으나 자본 및 운전비용이 과다하게 소요되는 광산 전체통기방법보다 풍관과 선풍기를 이용한 국부통기방법이 바람직한 방법으로 평가된다. 국내 대단면 장대 광산갱도에 풍관이 접속된 국부선풍기를 직렬로 연결 설치하는 경우에 통기시스템의 경제성과 효율의 최적화가 반드시 요구된다. 최적화를 위한 가장 중요한 두가지의 설계변수는 벽면 이격거리와 풍관 간의 이격거리이다. 본 연구에서는 경제적 및 환경적으로 최적화된, 즉 풍관간의 이격 공간을 통한 압력손실, 누기 그리고 오염된 공기의 재유입을 최소화할 수 있는 두 설계변수 값을 도출하기 위하여 광범위한 CFD분석을 시행하였다. 기존 연구결과와 권고기준들을 고려하여 이들 변수의 연구대상 범위를 선정하였다. 본 연구의 궁극적 목표는 국내 장대 광산갱도내 설치되는 풍관 접속 선풍기의 직렬연결 국부통기시스템의 최적화를 통하여 깨끗하고 안전한 작업장 환경을 제공하기 위함이다.

호남-제주 해저터널 가상설계의 공기압력 제어 덕트가 열차 주행에 미치는 영향에 대한 수치해석 연구 (A Numerical Study on the Effect of Pressure Relief Ducts on the Normal Pressure in a Preliminary Design of Honam-Jeju Subsea Tunnel)

  • 서상연;하희상
    • 한국지반환경공학회 논문집
    • /
    • 제17권8호
    • /
    • pp.17-27
    • /
    • 2016
  • 최근에는 고속 열차와 관련된 인프라가 발전한 유럽, 일본 같은 고속철도 선진국뿐만 아니라 미국과 중국에서도 고속철도 건설에 대한 구체적인 계획이 증가하고 있으며, 국내의 경우 수도권 광역급행철도(GTX)와 같은 대심도 지하 교통망의 건설이 추진되고 있다. 열차가 고속으로 주행할 경우 발생하는 공기저항을 최대한 감소시키기 위하여 열차의 선두부는 유선형으로 설계된다. 열차가 터널 내로 진입할 때, 터널 내에서 발생한 공기저항으로 인하여 열차가 터널을 주행할 때 개활지에서 주행하는 경우보다 훨씬 큰 동력이 요구된다. 따라서 일반적으로 열차가 터널로 진입할 때 공기저항 저감을 위하여 열차의 주행속도를 감소시킨다. 이렇게 열차의 속도를 감소시킬 경우 고속 열차의 운송 능력 및 장점이 감소되기 때문에 터널 내에서 열차의 주행 시에 발생하는 공기저항을 감소시키는 설비가 필수적이다. 이 연구에서는 터널 내에서 열차의 고속 주행을 위해 필요한 공기압력 제어 시스템의 효과를 분석하기 위하여 터널의 단면적 및 공기압력 제어 덕트의 단면적과 덕트의 간격이 열차 주행으로 인한 공기저항에 미치는 영향을 1차원 네트워크 수치해석 프로그램을 이용하여 분석하였다.

바이오 필터를 이용한 비육돈사 배기덕트 시설의 악취저감 효과 (Odor Removal Efficiency of Biofilter Ducting Systems in Indoor Pig House)

  • 송준익;최홍림;최희철;권두중;유용희;전중환
    • 한국축산시설환경학회지
    • /
    • 제13권3호
    • /
    • pp.195-200
    • /
    • 2007
  • 무창 육성 비육돈사에 대한 악취 제어 효율 비교분석을 위하여 Biofilter 덕트에 의한 악취 제어 연구를 수행하였다. 본 실험은 서울대 부속목장 실험돈사에서 실시하였으며 실험결과는 다음과 같다. 1. 무창 육성비육돈사에서 여름철 최대 배기시 바이오필터 외부로 배출되는 공기속도는 볏짚(.0.77 m/s), ALC(0.56 m/s)으로 측정되었다. 2. 실험시작 5일 후 가스검지기(GV-100)에 의한 간이측정시 암모니아($NH_3$) 농도는 필터 통과 후 볏짚($2mg/{\ell}$), ALC(3ppm)로 측정되어 부자재 사이의 공극율이 높은 볏짚이 높게 나타났다. 부자재에 따른 필터외부에서의 먼지측정 결과 볏짚($93\;mg/m^3$), ALC($32\;mg/m^3$)으로 측정되어 볏짚은 볏짚 간의 넓은 공극에서 발생하는 먼지 및 돈사내부의 먼지가 혼합되어 필터 외부로 배출되어 돈사내부보다 높게 측정되었다. 3. 황화수소($H_{2}S$) 가스농도 변화는 돈사내부에서는 측정일 7일(6 ppm), 21일(5 ppm) 및 36일(7 ppm) 경과함에 따라 어느 일정 시점에서 황화수소 가스농도는 증가하지 않았으나 다른 필터여재에서는 일정한 경향은 보이지 않았다. 이상의 실험결과를 종합해 볼 때 무창 육성비육 돈사에서 Biofilter를 이용한 악취저감 효과를 확인할 수 있었다.

  • PDF

공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001-)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.