고분자 필름의 두께변화에 따른 열전소자의 출력 특성변화에 관한 연구 (Research on the Output Characteristic of Thermoelectric Module according to the thickness variation of Polymer Pad)

  • 장호성;김재정;김인관;김영수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.976-981
    • /
    • 2006
  • In case of attaching thermoelectric module and heat source, the polymer pad is attached on the $Al_2O_3$ plate, which is cooling side of thermoelectric module, in order to enhance mechanical safety of the system. It is impossible to calculate the exact distribution of temperature and flow pattern of inner gap of thermoelectric module. Therefore CFD(Computational Fluid Dynamics) analysis was executed to determine the thermo-fluid phenomena and distribution by Fluent. As the result of these analysis, heat transfer was dominated by conduction and the difference of temperature was linear distribution according to the thickness of polymer sheet.

  • PDF

환기시스템 설치 강의실에서 시스템에어컨과 팬코일유닛의 열쾌적성 및 환기성능 평가 (Evaluation of Thermal Comfort and Ventilation Performance in the Lecture Room with Ventilation System and Two Different Air-conditioning Systems: System Air-conditioner or Fan Coil Unit)

  • 한창우;노광철;오명도
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.1079-1087
    • /
    • 2005
  • In this paper, thermal comfort and ventilation performance characteristics in the lecture room with the ventilation system and two different air-conditioning systems, system air-conditioner or fan coil unit, were evaluated by experimental and numerical methods. We compared the measured data with the computational results of the predicted mean vote and carbon dioxide concentration. Additionally the ventilation effectiveness was calculated numerically. From a viewpoint of the uniformity of PMVs in the lecture room, the thermal distribution performance of the system air-conditioner was more effective than the fan coil unit. Carbon dioxide concentration and ventilation effectiveness were barely affected by the type of the air-conditioning system.

고밀도 데이터센터의 열환경제어를 위한 수치해석 (Numerical Analysis of Thermal Environment Control in High-Density Data Center)

  • 권오경;김현중;차동안
    • 대한기계학회논문집B
    • /
    • 제36권8호
    • /
    • pp.821-828
    • /
    • 2012
  • CPU의 발열량 증가는 서버를 통과하는 배출공기와 유입공기와의 상당한 온도차를 발생시키고 이로 인해 배출공기의 재순환 현상과 유입공기의 바이패스 현상이 발생한다. 이는 데이터센터 냉각시스템의 효율저하를 발생시킨다. 따라서 CRAC의 제어를 통해 유입공기와 배출공기를 분리하는 것이 데이터센터 냉각시스템의 중요한 목표이다. 본 연구에서는 CFD 해석 코드인 ICEPAK을 이용하여 데이터센터에 대한 수치해석을 진행하였다. 실내부로 유입되는 공기유량의 변화에 따른 CPU의 온도와 실 전체의 온도분포를 분석하였다. 이를 통해 CPU의 발열량에 따른 최적 유입유량을 선정하였다. CPU 발열량이 100, 120, 140 W인 경우 유입유량이 $0.15m^3/s$인 지점에서 발열제거와 온도분배가 가장 잘 이루어졌다. RTI 성능지표를 이용하여 해석결과를 검증하였고 RTI 값이 81인 경우 가장 안정적인 결과를 보였다.

충돌판에 의한 원판형 분무의 공간분포에 관한 실험적 연구 (A Study on the Distribution of Cylindrical Disk Spray by a Impinging Disk)

  • 차건종;김덕줄
    • 대한기계학회논문집
    • /
    • 제19권1호
    • /
    • pp.251-262
    • /
    • 1995
  • The goal of this study is to provide fundamental information on the design of a new diesel injector system. The cylindrical disk spray was made by an impinging disk insited below the exit of air-assist atomizor. The disintegration processes on a twin-fluid atomization by air-assist atomizor were investigated. Liquid jet was disintegrated at the condition that wavelength was equal and longer than the circumference of the liquid jet, .lambda. .geq. .pi.do. However, the wavelength and the diameter of the liquid jet were decreased according to the increasing of air velocity. The relative density distribution of droplets and pattern of spray by impinging disk were investigated with a C-CCD. Optimum design conditions for cylindrical disk spray were also achieved. The pattern of cylindrical spray can classified according to the size of the disk and the distance from the nozzle tip to the disk. When the space of the disk and the nozzle tip was narrow and the diameter of the disk was larger than that of the air orifice of the nozzle exit, the good distribution of spray could be achieved. When the air flowrate was constant, the spray width was decreased according to the increasing of the liquid flowrate. When the liquid flowrate was constant, the spray width was decreased according to the increasing of the air flowrate.

간헐적인 연료분무의 유동특성에 관한 연구 (A Study on the Flow Characteristics of an Intermittent Fuel Spray)

  • 김원태;강신재
    • 대한기계학회논문집B
    • /
    • 제21권9호
    • /
    • pp.1198-1206
    • /
    • 1997
  • The flow characteristics of an intermittent fuel injection into a stationary ambient air were investigated using gasoline. The measurements were made by two-channel, air cooling type Phase Doppler Anemometer(PDA) system (DANTEC, 750 MW). And a pintle type injector of MPI (Multi-point Port Injection) system was utilized as a fuel injector. The PDA receiver optic was set up in a 60.deg. C forward scatter arrangement to obtain the optimum scattering signal of fuel droplets. The data were obtained by synchronizing PDA system with the fuel injection period, and the axial and radial velocity and turbulent components of fuel droplets were mainly measured for the analysis of temporal and spatial distribution depending upon the fuel injection pressures.

공조 시스템 내의 분배기 출구관의 삽입깊이에 따른 유량분포연구 (A Numerical Study on Refrigerant Distribution according to the Insertion Depth of the Distributor-Outlet Pipes in an Air-Conditioning System)

  • 이희원;박일석
    • 설비공학논문집
    • /
    • 제27권9호
    • /
    • pp.491-496
    • /
    • 2015
  • Generally, the phase of the refrigerants that circulate in air-conditioning systems is repeatedly changed from liquid to gas and from gas to liquid. In vapor-compression refrigeration, the refrigerant at the inlet of the evaporator is in a gas-liquid two-phase state; therefore, to enhance the heat-transfer performance of the evaporator, the even distribution of the refrigerant across multiple passages of the evaporator is essential. Unlike the distribution of a single-phase refrigerant, multi-phase distribution requires further considerations. It is known that the multi-phase distribution at the outlet of the distributor is affected by factors such as the operating condition, the distributor's shape, and the insertion depth of the outlet pipes; here, the insertion depth of the outlet pipes is especially significant. In this study, for a cylindrical distributor with a 90-degree bend entrance and three outlet pipes, the flow uniformity at the outlet pipes was numerically tested in relation to variations of the insertion depth of the outlet pipes.

Calculation of Outdoor Air Fraction through Economizer Control Types during Intermediate Season

  • Hong, Goopyo;Hong, Jun;Kim, Byungseon Sean
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose: In this study, we examined outdoor air fraction using historical data of actual Air Handling Unit (AHU) in the existing building during intermediate season and analyzed optimal outdoor air fraction by control types for economizer. Method: Control types for economizer which was used in analysis are No Economizer(NE), Differential Dry-bulb Temperature(DT), Diffrential Enthalpy(DE), Differential Dry-bulb Temperature+Differential Enthalpy(DTDE), and Differential Enthalpy+Differential Dry-bulb Temperature (DEDT). In addition, the system heating and cooling load were analyzed by calculating the outdoor air fraction through existing AHU operating method and control types for economizer. Result: Optimized outdoor air fraction through control types was the lowest in March and distribution over 50% was shown in May. In case of DE control type, outdoor air fraction was the highest of other control types and the value was average 63% in May. System heating load was shown the lowest value in NE, however, system cooling load was shown 1.7 times higher than DT control type and 5 times higher than DE control type. For system heating load, DT and DTDE is similar during intermediate season. However, system cooling load was shown 3 times higher than DE and DEDT. Accordingly, it was found as the method to save cooling energy most efficiently with DE control considering enthalpy of outdoor air and return air in intermediate season.

BLDC 전동기의 정현적 공극 자속밀도 구현에 의한 코깅 토크 저감 (Reduction of Cogging Torque of BLDC Motor by Sinusoidal Air-Gap Flux Density Distribution)

  • 김사무엘;정승호;류세현;권병일
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.57-65
    • /
    • 2007
  • Along with the development of power electronics and magnetic materials, permanent magnet (PM) brushless direct current (BLDC) motors are now widely used in many fields of modern industry BLDC motors have many advantages such as high efficiency, large peak torque, easy control of speed, and reliable working characteristics. However, Compared with the other electric motors without a PM, BLDC motors with a PM have inherent cogging torque. It is often a principle source of vibration, noise and difficulty of control in BLDC motors. Cogging torque which is produced by the interaction of the rotor magnetic flux and angular variation in the stator magnetic reluctance can be reduced by sinusoidal air-gap flux density waveform due to reduction of variation of magnetic reluctance. Therefore, this paper will present a design method of magnetizing system for reduction of cogging torque and low manufacturing cost of BLDC motor with isotropic bonded neodynium-iron-boron (Nd-Fe-B) magnets in ring type by sinusoidal air-gap flux density distribution. An analytical technique of magnetization makes use of two-dimensional finite element method (2-D FEM) and Preisach model that expresses the hysteresis phenomenon of magnetic materials in order for accurate calculation. In addition, For optimum design of magnetizing fixture, Factorial design which is one of the design of experiments (DOE) is used.

텔레매틱스 시스템을 이용한 항공 및 항만 물류 정보 연계에 관한 연구;인천 첨단물류도시 대상 (A Study on Concatenation of Air & Sea Logistics' Information Using Telematics System;Case of Inchoen u-City)

  • 홍승범;김웅이
    • 한국항공운항학회지
    • /
    • 제15권4호
    • /
    • pp.100-107
    • /
    • 2007
  • We proposed the concatenation of logistics' Information to constructing the intelligent logistics city that is to manage efficiently cargo distribution as providing at real-time information of cargo location trace and management through the Telematics/RFID. Case of the Incheon of the "Air Logistics Hub", this area is on an increasing trend on the quantity of cargo transport of the Air & Sea cargo system until 2006. As intelligent project of the Air's and the Sea's field is independently developed at each area, it is a problem on the concatenation of logistics' information such as freight location trace and management, operation management and route information of cargo vehicles. Therefore, we propose the advanced transport service model for the concatenating smoothly of Air & Sea cargo system. In this paper, we only manage the model of Air & Sea cargo system of the advance logistics city.

  • PDF

실내 에너지저장시스템 공조시스템의 열적 거동에 관한 연구 (Thermal Behavior of Air Conditioning System in an Indoor Energy Storage System)

  • 김준영;최낙삼;김진택
    • 신재생에너지
    • /
    • 제17권1호
    • /
    • pp.33-39
    • /
    • 2021
  • The energy use is increasing as the quality of human life improves. and research on the efficient use of energy in ESS (Energy Storage System) is ongoing. An air conditioner is required for the efficient use of an ESS, as are data on the distribution of the temperature of the latter based on the capacity of the air conditioner. In the absence of an air conditioner, the battery of the ESS reaches its maximum temperature of 40℃ after 2 h. When an air conditioner is present, the temperature of the battery stabilizes as the capacity of the former increases.