• 제목/요약/키워드: Air Conditioning Unit

검색결과 377건 처리시간 0.03초

발포 금속 내 공기 유동 및 압력강하에 관한 시뮬레이션 (The Simulation about the Air Flow and Pressure Drop inside the Metal Foam)

  • 김필환;김미화;장석준;정한식;정효민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1053-1058
    • /
    • 2008
  • Porous medium was considered in the present study for the heat transfer enhancement. This was attributed to its high surface area to volume ratio as well as intensive flow mixing by tortuous flow passages. But when the air or water flow through in the porous medium, it is occurred the pressure drop between inlet and outlet. So in the present study investigated simulation result about the pressure drop in the porous medium before apply to heat exchanger. In this simulation, the thickness of the solid inside the porous medium region was varied 0.2 mm to 0.4 mm. And then the simulation result were compared the pressure drop in the same unit cell ($0.5\;mm{\times}0.5\;mm{\times}0.5\;mm$). To make the analysis model, it was assumed the 14-sided tetrakaidecahedron cell which has long been considered the optimal packing cell first proposed by the Lord Kelvin in 1887. And then the simulation is carried out using by STAR-CCM+ which is commercial software. The simulation result can be showed quantified pressure drop by solid effect in the porous medium.

  • PDF

식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석 (Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis)

  • 김태한;최부헌;최나현;장은숙
    • 한국환경농학회지
    • /
    • 제37권4호
    • /
    • pp.268-276
    • /
    • 2018
  • 본 연구는 일반인에게 안전한 실내공기질 개선수단으로 인식되는 공기정화식물의 효율적 적용을 위해 실내공조에 요구되는 총풍량 확보가 가능한 식생기반 바이오필터 시스템을 제안하고자 했다. 시스템의 정량적 성능평가는 강의실형태의 실험실 체적 $332.73m^3$ 내 16명의 재실자 조건에서 목업단위 시스템의 공조 성능, 실내공기질 및 쾌적지표 개선효과에 대한 시계열 분석으로 진행되었다. 우선, 시스템 구동을 통해 총 $1,411.22m^3/h$의 유출 총풍량을 확보하여, 4.24 ACH의 환기율을 제공할 수 있었다. 실내온도는 $1.6^{\circ}C$, 흑구온도는 $1.0^{\circ}C$ 감소가 확인되었으며, 상대습도는 24.4% 상승한 최대 82.0%까지 증가하였다. 상대습도 급증에 따른 쾌적도 감소현상은 송풍기 구동에 따라 발생되는 실내기류로 상쇄되는 것으로 판단된다. 또한, 시스템 가동에 따른 공기질 개선지표 중 $PM_{10}$은 39.5% 감소한 평균 $22.11{\mu}g/m^3$을 기록하였다. 반면, $CO_2$는 최대 1,329 ppm까지 지속적으로 농도가 상승했는데, 이는 광도조건이 광보상점을 만족하지 못해 적용 식물과 재실자에서 방출되는 $CO_2$가 처리되지 못한 것으로 해석된다. 실내쾌적지표의 경우 PMV는 평균 83.6 % 감소된 -0.082, PPD는 평균 47.0% 감소된 5.41%에 수렴하여 식생기반 바이오필터 구동에 의해 높은 쾌적범위의 실내공간조성이 가능한 것으로 판단되었다. 본 연구의 한계는 소수 참여인원과 단기간 실험으로 인하여 시스템의 성능 규명이 제한적인 부분이었으며, 보다 장기간의 실험을 통해 바이오필터에 도입된 식생의 생육상태에 따른 압력손실 변화, 미세먼지 저감에 대한 구체적인 메커니즘 규명 등의 후속연구가 진행되어야 할 것이다.

해양심층수 기능성소금 제조를 위한 분무건조기 특성의 수치해석적 연구 (A Numerical Study on the Spray Dryer Characteristic for Manufacture of Deep Sea Water Salt)

  • 김현주;신필권;박성제
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 추계학술대회 논문집
    • /
    • pp.24-29
    • /
    • 2003
  • Deep sea water has cold temperature, abundant nutrients and minerals, and good water quality that is pathogen-free and stable. Compared with surface water, deep sea water contains more nutrition salt, such as nitrogen and phosphor. Moreover, if has the good balance of minerals. Because of the ability of the spray drying process to produce a free-flowing power considering of spherical particles with a well-defined size distribution and the rapid drying times for heat-sensitive material, spray drying is attractive for a wide range of applications spray drying is a unique unit operation in which powders are produced from a liquid feed in a single processing step. Key component of the process are atomizer, spray chamber. Design of spray chamber should be based on the atomizer type, the production rate, and the particle size required. Because of the complex processes taking place during spray drying, traditional design method are based on pilot-plant tests and empirical scale-up rules. Modern technique such as CFD have a role to play in design and troubleshooting.

  • PDF

부산시 에너지마일리지제 시범운영을 통한 가정용 전력 소비절감 효과분석 (Study on the effect of reducing consumption of domestic electric power by managing model energy mileage system in Busan)

  • 이은주;배민호;김재민;송국섭;곽노열;옥성애
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.934-939
    • /
    • 2009
  • To promote citizen's involvement in the GHG(Green House Gas) reduction policy, Busan city administration adopted an pilot energy incentive system called 'energy mileage'. The energy mileage system was designed to make energy end-users motivated to reduce domestic electricity use by providing financial rewards. Through the course of the pilot period, 5,3330 householders volunteerly participated the pilot system. About 66% of the participants managed to make energy saving against the same period of the previous year while 38.8% achieved the targeted reduction rate(i.e. over 10%) and received the equivalent rewards.

  • PDF

소형열병합발전 최적 시스템 설계 시뮬레이션 (A Simulation Study for the Optimum Design of Cogeneration System)

  • 임용훈;박화춘;최영호;정모
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.325-331
    • /
    • 2009
  • In this paper, a simulation approach for the optimum design of cogeneration system is described. For the purpose of the systematic analysis, a simulation tool is developed with which the prediction of the energy load, calculation of operation data according to prime mover or capacity of it, and estimation of economic gains can be carried out. As for the criterion of the optimum design, the economic gains by adopting cogeneration system is taken. Based on the capital, operation, and maintenance costs etc, LCC analysis is to be carried out for the scenarios respectively. In this study, the simulation for the apartment complex is performed and the analysis of the results are described in detail. The effects of the operation parameters such as capital cost, fuel cost, and unit cost for the purchase or sale of heat and electricity on overall economy are also be considered by sensitivity study.

  • PDF

지중열교환기 설치 조건이 지중 유효 열전도도에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the Effect of Ground Heat Exchanger to the Overall Thermal Conductivity)

  • 공형진;임효재;최재호;손병후
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.45-51
    • /
    • 2009
  • A ground-loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. The size and performance of this heat exchanger is highly dependent on ground thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U-tube configurations on ground effective thermal conductivity. In this study, thermal response tests were conducted using a testing device with 9-different ground-loop heat exchangers. From the experimental results, the length of ground-loop heat exchanger affects to the effective thermal conductivity. Among the various grouting materials, the bentonite-based grout with silica sand shows the largest thermal conductivity value.

  • PDF

왕복동식 압축시스템에 연결된 파이프 내부의 유동특성에 관한 CFD와 실험 (CFD and Experimental Study of Gas Flow Inside the Steel Pipe Fitted in Reciprocating Hydrogen Compression System)

  • 라흐만;이경환;이광성;정한식;정효민
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1513-1520
    • /
    • 2009
  • Renewability and pollutant free energy source makes hydrogen energy popular rapidly. Hydrogen gas pressure which is after passing through reciprocating compressor part has high pulsation wave form. A unit, snubber is used as compressor components to reduce the harmful pulsation waveform and to remove the impurities in the hydrogen gas. An experiment has been conducted to investigate the pulsation reduction performance of a steel pipe used in snubber system. The amplitude of pressure reduction were varied from $0.054{\sim}0.321\;kPa$ for 10 hz to 60 hz motor speed. Compressor operation by motor with 10 to 60 hz were resulted in reduction of pressure pulsation from 16.415% to 35.151%. Pressure losses were varied from $0.001%{\sim}0.759%$, and pressure drop per centimeter of the steel pipe were varied from $0.0160{\sim}16.03\;Pa$.

  • PDF

열병합발전에서 비용배분 방법론의 고찰 (Consideration of Cost Allocation Methodology on Cogeneration)

  • 김덕진
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1197-1202
    • /
    • 2009
  • Cost allocation on cogeneration is a methodology dividing the input of common cost to electricity cost and heat cost. In the cost allocation methodology of the electricity and heat on a cogeneration, there are energy method, work method, proportional method, benefit distribution method, reversible work method, various exergetic methods, and so on. In previous study, various cost allocation methodologies have been applied and analyzed on a gas-turbine cogeneration producing the 33.1 MW of electricity and the 32.2 Gcal/h of heat, a steam-turbine cogeneration producing the 22.2 MW of electricity and the 44.3 Gcal/h of heat, and combined-cycle cogeneration producing the 314.1 MW of electricity and the 279.4 Gcal/h of heat. In this study, we integrately analyze the results of previous studies and examine the generality and rationality each methodology. Additionally, a new point of view on the values of alternative electricity efficiency and alternative heat efficiency in the previous methodologies was proposed. As the integrated result, we conclude that reversible work method of various common cost allocation methodologies is most rational.

  • PDF

부산시 도시차원에서의 에너지 사용 현황 분석 (Analysis of City Level Energy Usage in Busan)

  • 김남욱;홍진영;박률
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1185-1190
    • /
    • 2009
  • Korea is an industrial country that overspends energy and has a policy that is more focused on a supply side. When an urban developmental program is to set up, surveys are carried out only with the respect to electricity, telecommunication, gas, and heating sources. Based on the existing survey results, the problems related to the supply side are being dealt with more importantly and the quantities of those supplies are estimated only by each energy source. The aim of this study is to provide basic information on energy consumption patterns of a diverse comsumer groups including industry, transportation, commerce, public and household to plan diverse energy policies. Through this basic information, it may be possible to analyze the energy consumption pattern by each consumer group and provide data for setting up efficient energy policies by the government. The energy consumption map that are analyzed and developed by the data obtained from Busan municipal area will be deposited and used as a part of the national energy statistics.

  • PDF

천연냉매인 이산화탄소의 세관 유동시 발생하는 증발 유동 현상에 대한 수치해석 연구 (Numerical Study on the Evaporation Flow Phenomena of Natural Refrigerant CO2 through Small Diameter Tubes)

  • 최인수;박병덕
    • 한국산업융합학회 논문집
    • /
    • 제10권2호
    • /
    • pp.89-96
    • /
    • 2007
  • For the environment protection, carbon dioxide as a natural refrigerant has been studied to use in an automotive air conditioning system. Hence, a numerical model has been developed to describe the evaporation phenomena of carbon dioxide flowing through very small diameter tubes. The two dimensional low-Reynolds $k-{\varepsilon}$ model was used to predict the flow phenomena of carbon dioxide in the two phase during its evaporation. Furthermore, the results obtained from the model were compared with the experiments for the validation. The heat transfer coefficient is lower, as the tube inner diameter becomes smaller. However, the amount of heat absorbed by a unit mass of carbon dioxide is greater due to more surface area. Therefore, the small diameter tube has advantage in terms of compact design of evaporator. When the inlet condition of pressure and temperature is low, the heat transfer coefficient is slightly high at the same size of tube because of the thermal properties of carbon dioxide.

  • PDF