The Simulation about the Air Flow and Pressure Drop inside the Metal Foam (발포 금속 내 공기 유동 및 압력강하에 관한 시뮬레이션)

  • Kim, Pil-Hwan;Jin, Mei-Hua;Jang, Seok-Jun;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1053-1058
    • /
    • 2008
  • Porous medium was considered in the present study for the heat transfer enhancement. This was attributed to its high surface area to volume ratio as well as intensive flow mixing by tortuous flow passages. But when the air or water flow through in the porous medium, it is occurred the pressure drop between inlet and outlet. So in the present study investigated simulation result about the pressure drop in the porous medium before apply to heat exchanger. In this simulation, the thickness of the solid inside the porous medium region was varied 0.2 mm to 0.4 mm. And then the simulation result were compared the pressure drop in the same unit cell ($0.5\;mm{\times}0.5\;mm{\times}0.5\;mm$). To make the analysis model, it was assumed the 14-sided tetrakaidecahedron cell which has long been considered the optimal packing cell first proposed by the Lord Kelvin in 1887. And then the simulation is carried out using by STAR-CCM+ which is commercial software. The simulation result can be showed quantified pressure drop by solid effect in the porous medium.

  • PDF

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

A Numerical Study on the Spray Dryer Characteristic for Manufacture of Deep Sea Water Salt (해양심층수 기능성소금 제조를 위한 분무건조기 특성의 수치해석적 연구)

  • Kim, Hyeon-Ju;Shin, Phil-Kwon;Park, Seong-Je
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.10a
    • /
    • pp.24-29
    • /
    • 2003
  • Deep sea water has cold temperature, abundant nutrients and minerals, and good water quality that is pathogen-free and stable. Compared with surface water, deep sea water contains more nutrition salt, such as nitrogen and phosphor. Moreover, if has the good balance of minerals. Because of the ability of the spray drying process to produce a free-flowing power considering of spherical particles with a well-defined size distribution and the rapid drying times for heat-sensitive material, spray drying is attractive for a wide range of applications spray drying is a unique unit operation in which powders are produced from a liquid feed in a single processing step. Key component of the process are atomizer, spray chamber. Design of spray chamber should be based on the atomizer type, the production rate, and the particle size required. Because of the complex processes taking place during spray drying, traditional design method are based on pilot-plant tests and empirical scale-up rules. Modern technique such as CFD have a role to play in design and troubleshooting.

  • PDF

Study on the effect of reducing consumption of domestic electric power by managing model energy mileage system in Busan (부산시 에너지마일리지제 시범운영을 통한 가정용 전력 소비절감 효과분석)

  • Lee, Eun-Ju;Pae, Min-Ho;Kim, Jae-Min;Song, Gook-Sup;Kwak, Ro-Yeul;Ok, Sung-Ae
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.934-939
    • /
    • 2009
  • To promote citizen's involvement in the GHG(Green House Gas) reduction policy, Busan city administration adopted an pilot energy incentive system called 'energy mileage'. The energy mileage system was designed to make energy end-users motivated to reduce domestic electricity use by providing financial rewards. Through the course of the pilot period, 5,3330 householders volunteerly participated the pilot system. About 66% of the participants managed to make energy saving against the same period of the previous year while 38.8% achieved the targeted reduction rate(i.e. over 10%) and received the equivalent rewards.

  • PDF

A Simulation Study for the Optimum Design of Cogeneration System (소형열병합발전 최적 시스템 설계 시뮬레이션)

  • Im, Yong-Hoon;Park, Hwa-Choon;Choi, Young-Ho;Chung, Mo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.325-331
    • /
    • 2009
  • In this paper, a simulation approach for the optimum design of cogeneration system is described. For the purpose of the systematic analysis, a simulation tool is developed with which the prediction of the energy load, calculation of operation data according to prime mover or capacity of it, and estimation of economic gains can be carried out. As for the criterion of the optimum design, the economic gains by adopting cogeneration system is taken. Based on the capital, operation, and maintenance costs etc, LCC analysis is to be carried out for the scenarios respectively. In this study, the simulation for the apartment complex is performed and the analysis of the results are described in detail. The effects of the operation parameters such as capital cost, fuel cost, and unit cost for the purchase or sale of heat and electricity on overall economy are also be considered by sensitivity study.

  • PDF

An Experimental Study on the Effect of Ground Heat Exchanger to the Overall Thermal Conductivity (지중열교환기 설치 조건이 지중 유효 열전도도에 미치는 영향에 관한 실험적 연구)

  • Kong, Hyoung-Jin;Lim, Hyo-Jae;Choi, Jae-Ho;Sohn, Byong-Hu
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.45-51
    • /
    • 2009
  • A ground-loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. The size and performance of this heat exchanger is highly dependent on ground thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U-tube configurations on ground effective thermal conductivity. In this study, thermal response tests were conducted using a testing device with 9-different ground-loop heat exchangers. From the experimental results, the length of ground-loop heat exchanger affects to the effective thermal conductivity. Among the various grouting materials, the bentonite-based grout with silica sand shows the largest thermal conductivity value.

  • PDF

CFD and Experimental Study of Gas Flow Inside the Steel Pipe Fitted in Reciprocating Hydrogen Compression System (왕복동식 압축시스템에 연결된 파이프 내부의 유동특성에 관한 CFD와 실험)

  • Rahman, Mohammad-Shiddiqur;Lee, Gyeong-Hwan;Lee, Kwang-Sung;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1513-1520
    • /
    • 2009
  • Renewability and pollutant free energy source makes hydrogen energy popular rapidly. Hydrogen gas pressure which is after passing through reciprocating compressor part has high pulsation wave form. A unit, snubber is used as compressor components to reduce the harmful pulsation waveform and to remove the impurities in the hydrogen gas. An experiment has been conducted to investigate the pulsation reduction performance of a steel pipe used in snubber system. The amplitude of pressure reduction were varied from $0.054{\sim}0.321\;kPa$ for 10 hz to 60 hz motor speed. Compressor operation by motor with 10 to 60 hz were resulted in reduction of pressure pulsation from 16.415% to 35.151%. Pressure losses were varied from $0.001%{\sim}0.759%$, and pressure drop per centimeter of the steel pipe were varied from $0.0160{\sim}16.03\;Pa$.

  • PDF

Consideration of Cost Allocation Methodology on Cogeneration (열병합발전에서 비용배분 방법론의 고찰)

  • Kim, Deok-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1197-1202
    • /
    • 2009
  • Cost allocation on cogeneration is a methodology dividing the input of common cost to electricity cost and heat cost. In the cost allocation methodology of the electricity and heat on a cogeneration, there are energy method, work method, proportional method, benefit distribution method, reversible work method, various exergetic methods, and so on. In previous study, various cost allocation methodologies have been applied and analyzed on a gas-turbine cogeneration producing the 33.1 MW of electricity and the 32.2 Gcal/h of heat, a steam-turbine cogeneration producing the 22.2 MW of electricity and the 44.3 Gcal/h of heat, and combined-cycle cogeneration producing the 314.1 MW of electricity and the 279.4 Gcal/h of heat. In this study, we integrately analyze the results of previous studies and examine the generality and rationality each methodology. Additionally, a new point of view on the values of alternative electricity efficiency and alternative heat efficiency in the previous methodologies was proposed. As the integrated result, we conclude that reversible work method of various common cost allocation methodologies is most rational.

  • PDF

Analysis of City Level Energy Usage in Busan (부산시 도시차원에서의 에너지 사용 현황 분석)

  • Kim, Nam-Wook;Hong, Jin-Young;Park, Yool
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1185-1190
    • /
    • 2009
  • Korea is an industrial country that overspends energy and has a policy that is more focused on a supply side. When an urban developmental program is to set up, surveys are carried out only with the respect to electricity, telecommunication, gas, and heating sources. Based on the existing survey results, the problems related to the supply side are being dealt with more importantly and the quantities of those supplies are estimated only by each energy source. The aim of this study is to provide basic information on energy consumption patterns of a diverse comsumer groups including industry, transportation, commerce, public and household to plan diverse energy policies. Through this basic information, it may be possible to analyze the energy consumption pattern by each consumer group and provide data for setting up efficient energy policies by the government. The energy consumption map that are analyzed and developed by the data obtained from Busan municipal area will be deposited and used as a part of the national energy statistics.

  • PDF

Numerical Study on the Evaporation Flow Phenomena of Natural Refrigerant CO2 through Small Diameter Tubes (천연냉매인 이산화탄소의 세관 유동시 발생하는 증발 유동 현상에 대한 수치해석 연구)

  • Choi, In-Su;Park, Byung-Duck
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.2
    • /
    • pp.89-96
    • /
    • 2007
  • For the environment protection, carbon dioxide as a natural refrigerant has been studied to use in an automotive air conditioning system. Hence, a numerical model has been developed to describe the evaporation phenomena of carbon dioxide flowing through very small diameter tubes. The two dimensional low-Reynolds $k-{\varepsilon}$ model was used to predict the flow phenomena of carbon dioxide in the two phase during its evaporation. Furthermore, the results obtained from the model were compared with the experiments for the validation. The heat transfer coefficient is lower, as the tube inner diameter becomes smaller. However, the amount of heat absorbed by a unit mass of carbon dioxide is greater due to more surface area. Therefore, the small diameter tube has advantage in terms of compact design of evaporator. When the inlet condition of pressure and temperature is low, the heat transfer coefficient is slightly high at the same size of tube because of the thermal properties of carbon dioxide.

  • PDF