• Title/Summary/Keyword: Air Conditioning Noise

Search Result 174, Processing Time 0.029 seconds

Load Modeling based on System Identification with Kalman Filtering of Electrical Energy Consumption of Residential Air-Conditioning

  • Patcharaprakiti, Nopporn;Tripak, Kasem;Saelao, Jeerawan
    • International journal of advanced smart convergence
    • /
    • v.4 no.1
    • /
    • pp.45-53
    • /
    • 2015
  • This paper is proposed mathematical load modelling based on system identification approach of energy consumption of residential air conditioning. Due to air conditioning is one of the significant equipment which consumes high energy and cause the peak load of power system especially in the summer time. The demand response is one of the solutions to decrease the load consumption and cutting peak load to avoid the reservation of power supply from power plant. In order to operate this solution, mathematical modelling of air conditioning which explains the behaviour is essential tool. The four type of linear model is selected for explanation the behaviour of this system. In order to obtain model, the experimental setup are performed by collecting input and output data every minute of 9,385 BTU/h air-conditioning split type with $25^{\circ}C$ thermostat setting of one sample house. The input data are composed of solar radiation ($W/m^2$) and ambient temperature ($^{\circ}C$). The output data are power and energy consumption of air conditioning. Both data are divided into two groups follow as training data and validation data for getting the exact model. The model is also verified with the other similar type of air condition by feed solar radiation and ambient temperature input data and compare the output energy consumption data. The best model in term of accuracy and model order is output error model with 70.78% accuracy and $17^{th}$ order. The model order reduction technique is used to reduce order of model to seven order for less complexity, then Kalman filtering technique is applied for remove white Gaussian noise for improve accuracy of model to be 72.66%. The obtained model can be also used for electrical load forecasting and designs the optimal size of renewable energy such photovoltaic system for supply the air conditioning.

An Experimental Study on the Supersonic Jet Noise from Multihole (다공 초음속 분류소음에 관한 실험적 연구)

  • Kwon, Y.P.;Suh, K.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.2
    • /
    • pp.96-105
    • /
    • 1992
  • The objective of this paper is to study experimentally on the noise characteristics of supersonic jet from multihole orifice in the range of jet pressure from $at_g$ to $at_g$ in the reverberation room. At first, the single orifice jets are investigated for various hole diameter from 3.8mm to 10mm. Through the noise spectrum, the turbulent mixing noise and the shock associated noise is analyzed. The noise for confined jets into a tube of diameter 30mm or 90mm with length 2m is investigated in comparision with that for the free jets. The sound power level is measured and compared with thoretical models for free jet. At second, multihole orifice jets are investigated to study the effect of multijet on noise reduction. The spectrum and power level of multijets are measured and compared with single jets. The multi-jets in a confined pipe are also investigated. It is found that the noise spectrum is significantly altered by increasing the number of jet with decrease in jet diameter and also by confining the jet into tube.

  • PDF

A Study on Changes in Characteristics of Drainage Noise from Water Closet Washing (대변기 세정시 발생하는 배수소음의 특성변화에 관한 연구)

  • Soul, Soo-Hwan;Jung, Chul-Woon;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.11
    • /
    • pp.789-796
    • /
    • 2007
  • It has been noted, in case of the apartments in collective form, the drainage noise from cleaning of toilet causes many problems in the basement and adjacent rooms, mainly hampering the pleasant housing environment. The problems are increasingly raised by civil complaints with the public offices. Therefore, if the drainage noise generates when wash out of toilet bowl is grasped how the characteristics change according to the sorts of drainpipe, it is considered that the establishment of an effective sound insulation countermeasure could be possible when a civil petition against the drainage noise of apartment house is submitted hereafter. On such viewpoint, this study measured and analyzed the characteristics of drainage noise per the type of drainage pipe, according to KS A ISO $1996-1{\sim}3$, with the horizontal branch pipe and riser pipes in the drainage noise experiment chamber which has the characteristics of the anechoic room. In the result, the pipe type with excellent noise reduction function. The result of this study is considered to become available as fundamental data, to take actions on reduction of drainage noise of the ceiling piping method.

A Study on Economic Analysis and Performance Appraisal of Compact Type Variable Air Volume (컴팩트형 VAV 공조기의 성능평가와 경제성 분석에 관한 연구)

  • Kim, Dong-Cheol;Chung, Kwang-Seop;Kim, Young Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.44-49
    • /
    • 2015
  • Ceiling cooling and heating system that consider load arrangement and space in the ceiling needs to be developed. Therefore, experimental and economic changes were done to verify the performance of compact type VAV. The test results were as follow. 1) Noise test result, measuring approximately 50.4 dB~56.6 dB (before ceiling in landfill), had a better ceiling deadline than the current measure, about a 10 dB noise reduction, so that the office baseline (40~50 dB) noise was judged to be less than test. 2) For the static pressure test result, taking out an outside hydrostatic 25 mmAq, 24.8 mmAq was measured, respectively, at the point. 3) For the life-cycle cost analysis result, the initial investment cost, maintenance replacement costs, and maintenance costs increased 0.2%, but the energy savings ratio was 19.5% while the whole life cycle savings of 40 years LCC was reduced 11.9%.

Methods of Reducing Noise Levels of the Cross-flow Fans of the Air-conditioners (에어컨 실내기 직교류 홴의 저소음화 방안)

  • Koo, Hyoung-Mo;Choi, Weon-Seok;Lee, Jin-Kyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1416-1422
    • /
    • 2000
  • The cross-flow fans have been widely used to constitute the air moving systems in many air-ventilating and air-conditioning devices. The cross-flow fan system has many design parameters which have crucial influence on the performance and the noise characteristics of the devices. As a result, there are many difficulties in the design stage of the devices and the general design guide has not been sufficiently established yet. This study presents the experimental results of the parametric investigation of some chosen design parameters, which are the shape of the stabilizer, the profile of the scroll casing, and the diffusion angle of the flow exit. The results are expressed as the fan performance and the specific sound pressure level characteristic. These parts have been found to have crucial effects on the system performance/noise characteristics and should be considered with care in the design stage.

  • PDF

A Study on the Prediction of Building Equipment Noise Generates at Machine Room (기계실에서 발생하는 설비소음의 예측에 관한 연구)

  • You, Hee-Jong;Jung, Eun-Jung;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.6
    • /
    • pp.476-484
    • /
    • 2007
  • Recently, in accordance with the buildings are becoming to large-sizes, high-stories, the large scaled facilities and equipments in machine room are quite demanding, and the generated noise volume according to this situation is on increasing. Since such noise is becoming to the object of a serious civil appeal, it is the real situation that a reduction countermeasure against the machine room equipment noise is keenly necessitated. On such viewpoint, this study has recorded, measured the noises which were generated from each individual as same as the whole equipped machines and tools, on the object of the dormitory machine rooms of the 3 colleges that haying mutually different peculiarities, then after grasp-ing their characters and acoustic powers, this research has verified its prediction possibility and the authenticity by comparison the estimated numerical value with the actually measured numerical value through the acoustic simulation. After grasping the prediction possibility in such way, by utilization of the sound absorption material in the machinery room, from the stage of design, the soundproof measures for the noise reduction at machine room could be regulated effectively, and it is also considered that such data would be utilized as the fundamental material for an establishment of the measure for sound insulation.

An Experimental Study of the Influences of Basic Design Parameters on the Performance and the Noise Characteristics of Cross-flow Fans (직교류 홴의 설계인자가 성능 및 소음 특성에 미치는 영향에 대한 실험적 연구)

  • 구형모
    • Journal of KSNVE
    • /
    • v.10 no.3
    • /
    • pp.430-436
    • /
    • 2000
  • The cross-flow fans have been widely used to constitute the air moving systems in many air-ventilating and air-conditioning units. The cross-flow fan system has many design parameters which have crucial influence on the performance and the noise characteristics of the units. As a result there are many difficulties in the design stage of the system and the general design guide has not been sufficiently established yet. This study presents the experimental results of the parametric investigation of some chosen design parameters which are directly related to the shape of the stabilizer the profile of the scroll casing and the diffusion angle of the flow exit. The results are expressed in terms of the fan performance and the specific sound pressure level characteristics. Some parameters have been found to have crucial effects on the system performance/noise characteristics and should be considered with care in the design stage.

  • PDF

Noise Source Identification of a Pulse Combustion Burner Using Digital Signal Processing Techniques (디지탈 신호처리 기법을 이용한 맥동연소기의 소음원 규명에 관한 연구)

  • Kim, D.W.;Cho, J.G.;Lee, K.S.;Oh, J.E.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.2
    • /
    • pp.103-113
    • /
    • 1991
  • This paper presents a method for estimating the noise source contribution of a pulse combustion burner in a multiple input system where the input sources may be coherent each other. By coherence function method, it is found that the biggest part of the noise source in the pulse combustion burner is generated by the part of the combustion chamber. This analysis is modeled as three input / single output system because the noise generating mechanism of the pulse combustion burner is very complicated. The coherence function method is proved to be useful tool for the identification of noise source. The overall levels of the radiated source pressure by coherence function method are compared with those measured and calculated by the frequency response function approach. The experimental results have shown a good agreement with the results calculated by the coherence function method when the input sources are coherent strongly each other. The estimation of shield effect by FRF method indicates that significant reduction can be achieved in sound radiation if only transmission path generated by the part of combustion chamber is acoustically shield.

  • PDF

A Research on Vocabulary Materialization for Evaluation of Architecture Plumbing Noise (건축설비소음 평가를 위한 어휘의 유형화에 관한 연구)

  • You, Hee-Jong;Jung, Eun-Jung;Kim, Jae-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.4
    • /
    • pp.346-354
    • /
    • 2007
  • Recently, in accordance with the buildings are rapidly becoming to high-stories, large-sizes, and since the case that noise of equipment machinery, tool itself infringes the life environment is on increasing, this is becoming to the object of civil appeal. Accordingly, in order to set up a countermeasure against such equipment machinery noise, even a systemic evaluating method is required, up to now while the appraisal that considering on the physical characteristic only had been done, but the characteristic about subjective valuation was not reflected as yet. Therefore, in this research, through the 1st, 2nd Psycho-Acoustics Experiments, the 30 vocabularies were extracted for evaluation of the construction equipment noise. As the result of Element Analysis, the 3 Elements were extracted from these vocabularies, and it could be understood that these Elements have been trustfully selected. It is now considering that the extracted vocabularies as per the above result would be used to Psycho-Acoustic Evaluation on Equipment Noise, and Psycho-Acoustics Experiment.