The Performance Characteristics of Heat Pump Using the Refrigerant Subcooling (냉매 과냉각을 이용한 열펌프 시스템의 성능 특성)

  • Roh, Geon-Sang;Son, Chan-Ghyo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.4
    • /
    • pp.413-421
    • /
    • 2007
  • In this paper, the performance characteristics of heat pump system using a new refrigerant subcooling system designed for the study, are introduced. The new heat pump system have the ice storage tank at the outlet of condenser. The experimental apparatus is a well-instrumented water/water heat pump which consisted of working fluid loop, coolant loop, and ice storage tank. The experiment parameters of subcooling ranged as the evaporating temperature from $-5^{\circ}C$ to $8^{\circ}C$, the condensing temperature from $30^{\circ}C$ to $35^{\circ}C$. The test of the ice storage was carried out at evaporating temperature of $-10^{\circ}C$ and the ice storage mode is Ice-On-Coil type. The working fluid was R-22 and the storage materials were city-water. The test results obtained were as follows; The refrigerant mass flow rate and compressor shaft power were unchanged by the degrees of subcooling, that is, they were independent of degrees of subcooling. The cooling capacity of the new heat pump system increase as the evaporating temperature and subcooling degrees increase and is higher by $25{\sim}30%$, compared to the normal heat pump system. The COP of the new heat pump system increases as the degrees of subcooling and evaporating temperature increase and is higher by 28% than that of the normal heat pump system.

Reduction in Indoor and Outdoor Temperature of Office Building with Cool Roof (쿨루프 적용에 따른 업무용 건물의 내·외부 온도 저감 효과)

  • Song, Bong-Geun;Kim, Gyeong-Ah;Park, Kyung-Hun
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: This study aims to identify the effect of temperature reduction by the application of cool roof coatings to Changwon City Hall in South Gyeongsang Province. The indoor and outdoor temperatures of the cool roofing building were analyzed and compared to that of an existing building with green-colored roof coated with waterproof polyurethane. Method: The surface temperatures and reflectivity of rooftops, surface temperatures of ceilings and the interior, and outdoor temperature and humidity of the two aforementioned buildings were measured from June to September in 2014. The measurements were taken every 10 min. Result: The surface temperature of the building with the cool roof was lower by a maximum of $9^{\circ}C$ with the reflectivity of the rooftop at an average of 0.55, which is higher than that of the building with green polyurethane by approximately 0.3. The temperature of the ceiling inside the building with the cool roof was about $1{\sim}2^{\circ}C$ lower than that of the ordinary building. Also, the indoor temperature of the office with cool roof coatings was about $0.5{\sim}1.0^{\circ}C$ lower than that of the office with green-colored roofing building. The results show that cool roof coatings can lower the temperature of buildings. In the next research, the reduction in consumption of energy for air conditioning will be investigated by utilizing building energy simulation tools.

Building Control Box Attached Monitor based Color Grid Recognition Methods for User Access Authentication

  • Yoon, Sung Hoon;Lee, Kil Soo;Cha, Jae Sang;Khudaybergenov, Timur;Kim, Min Soo;Woo, Deok Gun;Kim, Jeong Uk
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.1-7
    • /
    • 2020
  • The secure access the lighting, Heating, ventilation, and air conditioning (HVAC), fire safety, and security control boxes of building facilities is the primary objective of future smart buildings. This paper proposes an authorized user access to the electrical, lighting, fire safety, and security control boxes in the smart building, by using color grid coded optical camera communication (OCC) with face recognition Technologies. The existing CCTV subsystem can be used as the face recognition security subsystem for the proposed approach. At the same time a smart device attached camera can used as an OCC receiver of color grid code for user access authentication data sent by the control boxes to proceed authorization. This proposed approach allows increasing an authorization control reliability and highly secured authentication on accessing building facility infrastructure. The result of color grid code sequence received by the unauthorized person and his face identification allows getting good results in security and gaining effectiveness of accessing building facility infrastructure. The proposed concept uses the encoded user access authentication information through control box monitor and the smart device application which detect and decode the color grid coded informations combinations and then send user through the smart building network to building management system for authentication verification in combination with the facial features that gives a high protection level. The proposed concept is implemented on testbed model and experiment results verified for the secured user authentication in real-time.

An Evaluating of Daylighting Performance by Venetian Blind Shapes Type Change - Centre on Radiance Program (베네치안 블라인드 슬랫각도 형태변화에 따른 주광성능에 관한 연구 - Radiance Program 중심으로)

  • Lim, Tae Sub;Park, Jong Myung;Lim, Jung Hee;Kim, Byung Seon
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.59-66
    • /
    • 2013
  • Current Architectural Facade Designs have been trending to increased glass areas resulting in increasing impact on interior lighting and daylighting. In regards to indoor environmental quality, the increase in window space has a large impact on the daylighting received which ultimately impacts the liveability of a space. Especially when considering seasons, in the summer, excessive daylighting can result in glare as well as put an increased load in conditioning the air space further reducing energy efficiency. As a result, in order to improve the sustainability performance of a building, it is important to limit the natural lighting exposure to properly meet the needs and conditions of the building occupants. One of the most representative features to limit excessive sunlight exposure, is to incorporate operable blind systems. To this end, this research has been based on simulations performance through the Radiance Program. Radiance is capable of analyzing performance of daylight and impact of sunlight. Through analysis of different slat angles and blind shapes, impact and minimization of energy usage was evaluated. Furthermore, seasonal analysis was performed in order to understand the effects of seasonal climate factors. Ultimately this research provides an analysis of operable blinds optimization and effects of blind shape, control factors and angle of shading.

Calculating of 3-Dimensional Temperature Distribution for High-Temperature Exhaust Gas Using CT-TDLAS (CT-TDLAS를 이용한 고온 배기가스의 3차원 온도분포 측정)

  • YOON, DONGIK;KIM, JOONHO;JEON, MINGYU;CHOI, DOOWON;CHO, GYEONGRAE;DOH, DEOGHEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.1
    • /
    • pp.97-104
    • /
    • 2018
  • 3-dimensional temperature distribution of the exhaust gas of a fire flame of LPG have been measured by the constructed CT-TDLAS system. 3-Dimensional temperature distributions are measured by 2 layers of CT-TDLAS. Each layer has $8{\times}8$ laser beams implying the temperatures of 64 meshes are measured. SMART algorithm has been adopted for reconstructing the absorption coefficients on the meshes. The line strengths at 6 representative wave lengths of $H_2O$ have been used for obtaining the absorption spectra of the exhaust gas. The temperature distributions measured by the constructed CT-TDLAS have been compared with those by the thermocouples. The relative errors measured between by thermocouple and CT-TDLAS were 13% in average and 33% at maximum. The similarity of temperature distribution between by thermocouples and by CT-TDLAS has been shown at the lower layer than the upper layer implying an unstability of combustions.

A Comparative Analysis of Life Cycle Cost on the Window Glass and the Insulation Film Coated Glass for Window (창호 유리의 단열필름 시공에 따른 생애주기비용 비교 분석)

  • Jeong, Mingu;Kim, Gwang-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.6
    • /
    • pp.583-590
    • /
    • 2014
  • The purpose of this study is to analyze and compare the life cycle cost of window glass with insulation film and regular glass, to verify an economical window construction method. As an approach method, the thermal performance data of each type of glass was measured using Window 6.3 and ECO2-OD Simulation Program, applied it to the case building to calculate the air conditioning and heating maintenance costs and LCC, and compared the economic feasibility. As a result, installing an additional insulation film prevents the solar heat penetration in the summer, so it reduces the cooling cost, on the other hand, it increased heating cost in winter. From the life cycle cost perspective, the effect of cooling cost reduction does not counterbalance the increase in heating cost and the additional cost from film installation and repair; therefore, the installation of insulation film may not be a proper method.

An Exploratory Study of Energy Consumption and Management in the Home (가정에서의 열에너지 관리 현황조사 연구 -서울 지역을 중심으로-)

  • 윤복자
    • Journal of the Korean Home Economics Association
    • /
    • v.18 no.1
    • /
    • pp.67-82
    • /
    • 1980
  • The objectives of the study were to determine 1) energy uses for residential requirements, 2) if energy consumption and adoption of energy conservation attitudes and practices vary with independent variables family size, stage of family life cycle, homemaker's level of education, income, heating system, and number of electrical household items, and 3) if there is a correlation between energy conservation attitudes and practices. Questionnaires were given to the randomly selected homemakers I Seoul in the summer (September, 1979) and the winter (February, 1980). Analysis of variance and correlation were used to analyzed the data which consisted of 537 usable responses of 895 returned in the summer and 554 responses of 794 returned in the winter. The results are as follows: 1) The order of consumption rate of the direct energy uses for residential requirements was found to be heating and air conditioning, cooking, refrigeration, T.V., lighting, and miscellaneous. 2) Energy consumption and adoption of energy conservation attitudes and practices were significantly related to family size, homemaker's level of education, and the stage of family life cycle. (1) Families of five members revealed higher scores in attitudes and practices than families less than five or more than six. (2) The higher the homemaker's level of education, the more energy consumption and the higher scores I attitudes and practices were found. (3) Families in the middle stage of family life cycle tend to use more energy than younger or older families, but their scores in attitudes and practices were high. 3) There was a significant correlation between energy conservation attitudes and practices. However, the scores of the conservation practices were not as good as the attitudes. It may be attributed to either a lack of knowledge and/or financial difficulties, or a dissonance between the concept and implementation of energy conservation. 4) Recommendations for the energy-saving and energy-related public policies are: (1) to use such human resources as attitudes, values, feelings of agreement, and cooperation, as well as nonhuman resources for the energy conservation, (2) to develop a educational program and a creative system I order to implement energy conservation programs, and (3) to consider direct as well as indirect energy uses I selecting goods and services.

  • PDF

The Factor Analyses of Service Quality Components in University Libraries (대학도서관 서비스 질의 구성요인 분석)

  • Paik, Hang-Ki;Lee, Eun-Chul
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.34 no.4
    • /
    • pp.5-26
    • /
    • 2000
  • The purpose of this study was to measure performance of university libraries, especially investigating the components of service quality and their relationship to the customer satisfaction. The result of the study was summarized as follows: First, the factors on satisfaction of library service revealed 12 factors such as access of information, quality of employees, suitable collections, issues related to civil petitions, equipments and facilities, timeliness, operating hours, use of information technology, library user education, reference service, public relation and individual service. Second, the factors of library service on customer satisfaction showed the following primary factors: suitable collections, issues related to civil petitions, access of information, equipments and facilities, timeliness, public relation, reference service, operating hours, and individual service. Third, the components of library service on customwe satisfaction showed the following primary components: availability, the number of books and journals, facilities of air conditioning, public relation, usefulness of retrieval system, waiting time for Internet use, operating hour, speed of repairs, receipt of civil petitions, use of non-book materials.

  • PDF

An Evaluation and Prediction of Performance of Road Snow-melting System Utilized by Ground Source Heat Pump (지열원히트펌프를 활용한 도로융설시스템의 성능 평가 및 예측)

  • Choi, Deok-In;Hwang, Kwang-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.138-145
    • /
    • 2012
  • Because of the climate changes and the development of building technologies, the cooling loads have been increased. Among the various renewable energies, geothermal energy is known as very useful and stable energy for heating and cooling of building. This study proposes a road snow-melting system of which heat is supplied from GSHP(Ground source heat pump) in viewpoint of the initial investment and annual running performance, which is also operating as a main facility of heating and cooling for common spaces. The results of this study is as followings. From the site measurement, it is found out that the road surface temperature above the geothermal heating pipe rose up to $5^{\circ}C$, which is the design temperature of road snow-melting, after 2 hours' operation and average COP(Coefficient of performance) was estimated as 3.5. The reliability of CFD has confirmed, because the temperature difference between results of CFD analysis and site measurement is only ${\pm}0.4^{\circ}C$ and the trend of temperature variation is quite similar. CFD analysis on the effect of pavement materials clearly show that more than 2 hours is needed for snow-melting, if the road is paved by ascon or concrete. But the road paved by brick is not reached to $5^{\circ}C$ at all. To evaluate the feasibility of snow-melting system operated by a geothermal circulation which has not GSHP, the surface temperature of concrete-paved road rise up to $0^{\circ}C$ after 2 hour and 40 minutes, and it does never increase to $5^{\circ}C$. And the roads paved by ascon and brick is maintained as below $0^{\circ}C$ after 12 hours geothermal circulation.

Energy Saving Strategies for Ice Rink using Sea-Water Heat Source Cooling System (해수열원을 이용한 빙상경기장의 에너지절약 방안에 관한 연구)

  • Kim, Samuel;Park, Jin-Young;Park, Jae-Hong
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.2
    • /
    • pp.53-59
    • /
    • 2014
  • Ice Rink is energy intensive building type. Concern of energy saving from buildings is one of very important issues nowadays. New and renewable energy sources for buildings are especially important when we concern about energy supply for buildings. Among new and renewable energy sources, use of seawater for heating and cooling is an emerging issue for energy conscious building design. The options of energy use from sea water heat sources are using deep sea water for direct cooling with heat exchange facilities, and using surface layer water with heat pump systems. In this study, energy consumptions for an Ice Rink building are analyzed according to the heat sources of air-conditioning systems; existing system and sea water heat source system, in a coastal city, Kangnung. The location of the city Kangnung is good for using both deep sea water which is constant temperature throughout the year less than $2^{\circ}C$, and surface layer water which should be accompanied with heat pump systems. The result shows that using sea water from 200m and 30m under sea lever can save annual energy consumption about 33% of original system and about 10% of that using seawater from 0m depth. Annual energy consumption is similar between the systems with seawater from 200m and 30m. Although the amount of energy saving in summer of the system with 200m depth is higher than that with 30m depth, the requirement of energy in winter of the system with 200m depth is bigger than that with 30m depth.