• Title/Summary/Keyword: Air Conditioner

Search Result 775, Processing Time 0.033 seconds

Comfort Control Algorithm Development of Car Air Conditioner using Thermal Comfort Evaluation of The Driver : Part II-Physiological Response of Driver (자동차 에어컨 쾌적제어 알고리즘 개발을 위한 운전자 온열감성 평가 : 제 2보-운전자의 생리반응)

  • Kim, Minsoo;Kim, Donggyu;Park, Jongil;Kum, Jongsoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.217-223
    • /
    • 2016
  • In this study, we investigated the operating method of a driver for an air conditioning system according to the temperature difference between the indoor and outdoor environments of a car parked outside during the summer. Researchers of this study suggest the comfort mode of a car air conditioner to improve the thermal comfort of the driver, thereby maintaining longer comfort. This study separately, analyzed temperatures on a cloudy day and sunny day. The results showed the car indoor heat environment and physiological results (EEG, ECG) of the subject. It showed a difference of the car indoor heat environment by weather with the difference also appearing in the physiological response of the subject. In conclusion, in this paper, on the basis of the physiological response of a subject, a comfortable algorithm of automobile air conditioner is being suggested.

The Design of a Linear Compressor Based on the Resonance Characteristics for the Air Conditioner (공진특성을 고려한 냉동/공조용 횡자속 선형압축기의 설계)

  • Hong, Yong-Ju;Park, Seong-Je;Kim, Hyo-Bong
    • 연구논문집
    • /
    • s.34
    • /
    • pp.39-46
    • /
    • 2004
  • The compressors in the air conditioner have the role of the pressurization and circulation of the refrigerant. The hermetic reciprocating compressors driven by rotary motor have been used for the air conditioner. The linear compressor has very simple structure and enhancement in the efficiency in comparison to that of conventional reciprocating compressor. The linear compressors are widely used for the small cryogenic refrigerator (below 1 kW), such as the Stirling refrigerator and pulse tube refrigerator. In the cryogenic application, the pressure ratio of the linear compressor is below 1.5, but the linear compressor for the air conditioner should overcome the high pressure ratio and the large pressure difference between the each sides of the piston. The resonance characteristics of the linear compressor has the significant impacts on the power consumption. To minimize the power consumption, the linear compressor should be operated at the resonance point. In the resonance characteristics, the role of the mechanical and gas spring should be considered. In present study, the cycle of the analysis of the vapor compression refrigeration cycle with the different refrigerants (R134a, R4l0a, R600a) and the designs of the linear compressor are performed. The effects of the stiffness of the mechanical spring on the electromagnetic forces would be discussed. Finally, the results show the design specification of the linear compressor for the air conditioner.

  • PDF

Shape Optimization of an Air-conditioner Compressor Mounting Bracket (차량용 에어컨 컴프레서 브라켓의 형상최적화)

  • 제형호;김찬묵;강영규;이두호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.389-394
    • /
    • 2003
  • In this paper, a shape optimization technique is applied to design of an air-conditioner mounting bracket. The mounting bracket is a structural component of an engine, on which bolts attach an air-conditioner compressor. The air-conditioner mounting bracket has a large portion of weight among the engine components. To reduce weight of the bracket, the shape is optimized using a finite element software. The compressor assembly, composed of a compressor and a bracket is modeled using finite elements. An objective function for the shape optimization of the bracket is the weight of the bracket. Two design constraints on the bracket are the first resonant frequency of the compressor assembly and the fatigue life of the bracket. The design variables are the shape of the bracket including thickness profiles of the front and back surfaces of the bracket, radius of outer bolt-holes, and side edge profiles. The coordinates of the FE nodes control the shape parameters. Optimal shapes of the bracket are obtained by using SOL200 of MSC/NASTRAN.

  • PDF

Design Improvement via Structural Dynamics Modification - Application to Noise Reduction in Outdoor Unit of Air Conditioner (구조물 동특성 변경을 통한 설계 개선 -공조기 실외기 소음 저감 적용)

  • Choi, Sang-Hyeon;Park, Nam-Gyu;Park, Youn-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.5
    • /
    • pp.355-364
    • /
    • 2002
  • The goal of this research is to reduce noise level of an outdoor unit of air conditioner by changing its dynamic characteristics using SDM (structural dynamics modification) technique. At first, the emitting noise was measured and analyzed. The measurement records show the most critical frequency components which influences on the noise level. Then it was tried to move the natural frequencies outside the critical frequency region by SDM. Since it is very difficult to get a reliable FE model of air conditioner, experimentally measured frequency response functions were used to derive sensitivities that are very important to obtain design changes. The positions of modification and the thickness of modifying structures were determined to improve the dynamic characteristics of air conditioner. The recommended design guideline to move its natural frequencies outside the targeting frequency range was obtained. Then in order to prove its effectiveness, the changed design was experimentally tested and found that the SDM result is very effective to reduce not only its vibration but also its emitting noise.

The correlation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner (가정용 에어컨 실외기의 기동 소음 분석)

  • Son, Young-boo;Lee, Seung-mock;Ha, Jong-hun;Lee, Byeoung-chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.577-582
    • /
    • 2012
  • Recently, noise reduction of air-conditioner is one of the important design factors for high quality product. Especially, customer complaints arise due to noise problem of the outdoor unit. After the operation of air-conditioner start, noise level of outdoor unit is increased gradually and sometimes abnormal noise occurs until it reaches steady state condition. The aim of this paper is to investigate the relation between noise of outdoor unit and thermodynamic properties of cycle at transient condition of room air-conditioner. In order to find out the noise characteristics of outdoor unit, noise and vibration measurements are carried out. Also, the thermodynamic properties of compressor and heat exchanger are measured by using temperature and pressure sensors and experimental results are discussed. Finally, we find out the relation between noise and cycle properties at starting of room air-conditioner and the improvement method to reduce noise level is proposed.

  • PDF

Fuzzy Precompensated PI Controller for Inverter-type Air-Conditioner (인버터형 에어컨의 온도 제어를 위한 퍼지 전단 보상된 PI 제어기)

  • 장보인;이선우;정문종;유장현;김상권;박윤서
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1997.10a
    • /
    • pp.185-188
    • /
    • 1997
  • In this paper, a fuzzy precompensated PI controller for inverter-type air-conditioner is presented. The presented control scheme is composed of a fuzzy logic precompensator and PI controller, in which two control schemes are serially connected. The rules of the fuzzy precompensator is designed to improve the performance by considering the nonlinear characteristics of a temperature dynamics. The experimental results show the effectiveness of the proposed controller.

  • PDF

Design and Effects of Power Factor Correction Circuit for Inverter Air-Conditioner (인버터 에어컨용 능동역률보상회로 설계 및 효과)

  • 박병욱;권경안
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.27-30
    • /
    • 1998
  • In this paper, the inverter air-conditioner with Power Factor Correction(PFC) circuit is Presented for obtaining the good system efficiency and cost merit compared with the conventional inverter air-conditioner. The detailed design procedures for getting the optimal passive components are implemented. Through the simulation and experimental results, it is shown that the system efficiency can be improved. Using the designed components, the prototype system is builted and tested to verify the additional good performances of the proposed circuit.

  • PDF

Reliability Analysis of Air-conditioner with Service Data (에어컨 서비스데이터 신뢰도분석)

  • Yun, Won-Young;Sung, Mun-Hyun;Choung, Seock-Joo
    • IE interfaces
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 1999
  • This paper presents a method for reliability analysis of the air-conditioner with service data. We explain how to acquire and analyze the service data and some problems in data analysis. We propose two procedures to analyze reliability of air-conditioner using operating time concept and predict the operating times by temperature and failure frequency. Finally, the prediction method for future service is studied by numerical example.

  • PDF

Corrosion Resistance of Zn and Cu Coated Steel Pipes as a Substitute for Cu Pipe in an Air Conditioner System

  • Shin, Jae-Gyeong;Park, Chan-Jin;Hong, Sung-Kil
    • Corrosion Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.40-43
    • /
    • 2009
  • We investigated the corrosion resistance of Zn and Cu coated steel pipes as a substitute for Cu pipe in an air-conditioner system. In addition, the galvanic corrosion tendency between two dissimilar metal parts was studied. The corrosion resistance of the Cu electroplated steel was similar to that of Cu, while the corrosion rate of the Zn electro- galvanized and the galvalume (Zn-55 % Al) coated steels was much higher and not suitable for Cu substitute in artificial sea water and acidic rain environments. Furthermore, the galvanic difference between Cu electroplated steel and Cu was so small that the Cu coated steel pipe can be used as a substitute for Cu pipe in an air-conditioner system.

Optimal Design of the Pipe Configuration of an Air Conditioner Outdoor Unit Considering Vibration Characteristics (진동특성을 고려한 에어컨 실외기 배관의 최적설계)

  • Kim, Jun-Hyung;Park, Chang-Bae;Choi, Soo-Yong;Min, Je-Hong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.655-660
    • /
    • 2004
  • The pipes in the outdoor unit of an air conditioner are designed to reduce the vibration effect of the compressor. Three-dimensional structure of the pipe could provide various design choices and the resultant vibration characteristics of the outdoor units. A design program has been developed for an eligible parametric study of pipe design and automatic vibration analysis using commercial software, I-DEAS, and its macro. Optimal design of pipe configuration has been performed using the commercial software, iSIGHT. The optimized design shows 70 percents improvement in the vibration characteristics of the outdoor unit of an air conditioner.

  • PDF