• Title/Summary/Keyword: Air Condition

Search Result 4,333, Processing Time 0.038 seconds

Cycle Simulation of the Air-Conditioner Using Alternatives to R22 (R22의 대체냉매를 사용한 공기조화기의 성능 시뮬레이션)

  • Chang, S.D.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.1
    • /
    • pp.47-53
    • /
    • 1994
  • Cycle simulation of the air-conditioner was carried out using a number of candidate alternatives to R22;R32/R125/R134a(30/10/60, by mass percent), R32/R125/R134a(10/70/20), R32/R134a(25/75), R32/R134a(30/70), R32/R125(60/40), R290(propane) and R134a. In this study, we considered only the basic parts of the air-conditioner such as the compressor, the evaporator, the condenser and the capillary tube, for the purpose of analysis. The performance characteristics of alternatives considered here were examined by comparing with the case using R22 at the constant volumetric flow rate condition. The results of our analysis revealed that the use of refrigerant mixtures, R32/R134a(30/70) and R32/R125/R134a(30/10/60), was appropriate for the alternatives to R22 in view of the cooling capacity and the COP. For the case of using R134a and R290, the COP was observed to increase under the same volumetric flow rate condition, but the cooling capacity was substantially decreased. Therefore the use of R134a and R290 should be accompanied with increasing considerably the size of compressor in order to maintain the same cooling capacity of R22.

  • PDF

Forest Stratification Effect of Air Temperature and Humidity in the Green Space (수림의 계층구조가 녹지내의 기온 및 습도에 미치는 영향)

  • Yoon, Yong-Han
    • Korean Journal of Environmental Biology
    • /
    • v.21 no.2
    • /
    • pp.120-125
    • /
    • 2003
  • For this study grasp coverage condition and forest stratification to various green space, observed air temperature and relative humidity. With this data, coverage condition and air temperature, relative humidity distribution, analyzed relationship of forest rate and air temperature or relative humidity, tree numbers and green volume and humidity by revolution analysis. In this result, higher none is formed artificiality and barren area, lower zone did fores and water area. Relative humidity have corresponding type of air temperature distribution. lower Tone was higher humidity. Different of Idlest type or water area, surround of forest showed relatively higher humidity. Increasing tree numbers or green volume effect higher humidity and this efficiency order of an arbor, subarbor, shrub.

A Study on the Indoor Air Quality in the bedroom with respect to Temperature and Humidity conditions (온도 및 습도 조건에 따른 침실 공기환경에 관한 연구)

  • Kim, Dong-Gyu;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.11 no.3
    • /
    • pp.31-36
    • /
    • 2011
  • People spend most of their time inside buildings recently, so the indoor air quality is one of the most important factors to human health. Furthermore, minimum energy use with proper ventilation systems for pleasant indoor environment is necessary because of energy shortage over the world. The concern to maintain proper indoor air quality at home has been increased, and a proper indoor air quality is continuously requested by the residents. By measuring and analyzing the density fluctuation of $CO_2$ through indoor humidity and testing personal reactions regarding comfort condition, we can obtain a way to effective ventilation. Heat and carbon dioxide emissions from resident's metabolism and construction materials could be the causes of indoor air pollution. If these materials stay indoors for a long time, it could directly influence the resident's health condition with diseases. It also leads massive energy use. Therefore, the way to save energy and to have effective control of indoor ventilation is needed. This study presented the control method of bedroom ventilation by $CO_2$ concentration change and subjective evaluation.

Heat and Mass Transfer of Parallel Plate Heat Exchanger under Frosting Condition (착상조건하에서 평행 평판 열교환기의 열 및 물질전달)

  • Lee, K.S.;Lee, T.H.;Kim, W.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.155-165
    • /
    • 1994
  • In this study, the following factors are investigated from experiments for a vertical parallel plate heat exchanger under the frosting condition ; the growth of frost layer, the characteristics of heat and mass transfer, the change of mass flow rate of the air passing through the heat exchanger, and the pressure drop of the air in the heat exchanger. The amount of heat and mass flux of water vapor transferred from the air stream to the heat exchanger surface is large at the early stage of frosting and then decreases dramatically, and the extent of decreasing rate becomes moderate with time. The frost layer formed near the inlet of the heat exchanger is thicker and denser than that formed near the outlet. It is found that the gradient of the amount of frost along the flow direction increases with time. In the early period of frost formation, the thermal resistance between the air and the cooling plate increases dramatically and then the extent of change decreases with time. Initially the convective thermal resistance is dominant. Then, while the convective thermal resistance decreases with time, the conductive thermal resistance continues to increase with time and finally the conductive thermal resistance becomes dominant.

  • PDF

A Study on the Removal Performance of PM10 by the Air-washer and the Ultrasonic Humidifier (자연 기화식 가습기와 초음파 가습기의 PM10 제거성능)

  • Lee, Joo-Ho;Kim, Sun-Sook;Park, Sung-Kwan;Park, Jun-Hyung;Lee, Yun-Gye
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.720-724
    • /
    • 2008
  • The purpose of this study is to evaluate the PM10 removal efficiencies of an Air-washer and an Ultrasonic humidifier by mock-up experiments. The concentrations of PM10 were measured at 5 minute intervals using $\beta$-Ray method. The average PM10 removal efficiency of the Air-washer was 79.8%, while the PM10 concentrations increased with the operation of Ultrasonic humidifier. In the case of operating the Air-washer, the R.H(Relative Humidity) level of the test room was maintained at around 45%, regardless of initial R.H condition. The R.H of the test room with Ultrasonic humidifier was influenced by the initial R.H condition.

  • PDF

Response Surface Approach to Design Optimization of Regenerator Using Hot Air Heated by Solar Collector (태양열 온풍 이용을 위한 재생기의 설계 최적화 모델에 관한 연구)

  • Woo, Jong-Soo;Choi, Kwang-Hwan;Yoon, Jeong-In
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.3
    • /
    • pp.7-14
    • /
    • 2003
  • Absorption potential of desiccant solution significantly decreases after absorbing moisture from humid air, and a regeneration process requires a great amount of energy to recover absorption potential of desiccant solution. In an effort to develop an energy efficient regenerator, this study examines a regeneration process using hot air heated by solar radiation to recover absorption potential by evaporating moisture in liquid desiccant. More specifically, this study is aimed at finding the optimum operating condition of the regenerator by utilizing a well-established statistical tool, so-called response surface methodology(RSM), which may provide a functional relationship between independent and dependent variables. It is demonstrated that an optimization model to find the optimum operating condition can be obtained using the functional relationship between regeneration rate and affecting factors which is approximated on the basis experimental results.

A study on the Development and Evaluation of Sludge Occlusion Reduced Diffuser (폐색 저감형 산기관의 개발 및 적용성 평가)

  • Kim, Young-Hoon;Kim, Kwan-Yeop;Lee, Eui-Jong;Nam, Jong-Woo;Lee, Chang-Ha;Jeon, Min-Jung;Kim, Hyung-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.1
    • /
    • pp.41-49
    • /
    • 2011
  • The diffuser which is conventionally adapted to MBR, has problem that decreasing the cleaning effect of membrane module by inflexible air supply due to the occlusion of sludge from diffuser hole. To solve this problem, diffuser structure of submerged module should be improved to discharge sludge which is flow into the diffuser for prevent occlusion in the diffuser. In this study, the structure of the diffuser was reformed to open lower part for preclusion the blocking. And the outlet diameter of the diffuser was drawn through the condition for the depth of water and air rate, to prevent air-leak condition of improved diffuser. Moreover, application is evaluated by comparing test with occlusion effect of the conventional and improved diffuser. From the results, air-water boundary changes are steady with changes of water depth and it shows linear relation about air rate. By using this linear numerical formula, the height of diffuser's outlet can be decided. Also, it displays that it can prevent the occlusion effect during the comparing test. Hereafter, if this diffuser is applied to practical MBR process, the occlusion problem of diffuser will be disappeared.

Preparation of Polyethylene Micro-fibers by High Speed Centrifugal Melt Spinning (초고속 용융 원심방사를 이용한 폴리에틸렌 마이크론 섬유의 제조)

  • Yang, Seong Baek;Lee, Jungeon;Ji, Byung Chul;Joo, Nam Sik;Yeum, Jeong Hyun
    • Textile Coloration and Finishing
    • /
    • v.32 no.4
    • /
    • pp.239-244
    • /
    • 2020
  • Polyethylene (PE) micro-fiber have been prepared at different hot air temperature (60, 80 and 100 ℃) and different pressure (20, 40, 60 and 80 kPa) by melt centrifugal spinning technique. The parameters of melting centrifugal spinning including polymer contents, rotational velocity, temperature of hot air and pressure were optimized for the fabrication process. The study showed that 8000 rpm rotational velocity, 80 ℃ heated hot air and 40 kPa air pressure are the best condition to obtain uniform and strong PE fiber. The prepared PE fibers were analyzed by field emission scanning electron microscope and universal testing machine and found that fibers with reduced diameter and improved tensile strength are obtained at hot air condition.

A Survey on the Sanitary Condition of Kitchens of School Lunch Program

  • Kim, Jong-Gyu
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2003.06a
    • /
    • pp.174-176
    • /
    • 2003
  • A survey was conducted to investigate the sanitary condition of school kitchens in one region of Korea. A self-administered questionnaire recommended by the Korea Ministry of Education & Human Resources Development (MOEHRD) was offered to a random sample of dieticians of twenty-five elementary schools for food, sanitation and safety inspection of their kitchens. Air temperature, relative humidity, and airborne microbes in the kitchens were monitored during food preparation, processing and service. The inspection results showed their sanitary condition met the level B of the recommendation of the Korea MOEHRD. The range of air temperature of the kitchens was 21.4∼22.4$^{\circ}C$, and the range of relative humidity was 62.4∼69.6%. The microbiological evaluation of kitchen samples indicated aerobic plate count levels from 22.5 to 26.5 CFU/15 min. These results indicate that the levels of sanitary condition of kitchens in the schools were not satisfactory for safe foodservice although the inspection showed good results. This study suggests that the school kitchens should be monitored and strict inspection is necessary.

  • PDF

Optimum Design Condition of the Collins Cryocooler (Collins 내동기의 최적 설계조건)

  • Lee, S.W.;Kim, S.Y.;Jung, P.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.3
    • /
    • pp.183-190
    • /
    • 1992
  • The Collins cryocooler is numerically analysed with the optimization technique, and the optimum operating and design conditions are searched. This paper shows that liquefied helium quantity has an external maximum w.r.t. the total mass flow rate, the mass flow rates through expander and the capacities of heat exchangers. The liquefied helium quantity increases as the compressor exit pressure of the cryocooler does. The maximum quantity of liquefied helium and the maximum coefficient of performance have been found to exist in extremum, depending on the ratios of each heat exchanger capicities to the total one. At the optimum condition, the capacity of heat exchanger in high temperature region is larger than that in low temperature region.

  • PDF