• Title/Summary/Keyword: Air Bubble

Search Result 406, Processing Time 0.027 seconds

Performance evaluation of bubble pump used on solar water heating system

  • Xuesong, Li;Park, Gi-Tae;Kim, Pil-Hwan;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.416-422
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and their relationship with the solar radiation intensity. The theory analysis of design bubble pump has been given and the experiment result analysis has been included in the paper.

  • PDF

Field Application to Evaluate the Effect of Various Surface Covered Curing Blankets on Temperature Profile and Crack Occurrence of the Concrete under Hot Weather Condition (서중환경에서 표면피복 양생재 종류변화가 콘크리트의 초기 온도이력 및 균열발생에 미치는 영향에 관한 현장적용성 평가)

  • Han, Min-Cheol;Lee, Sang-Woon
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.5
    • /
    • pp.27-34
    • /
    • 2018
  • Concrete placed under hot weather condition suffers from larger slump loss, rapid moisture evaporation due to high air temperature. Proper measures for material, transportation and curing should be taken to prevent the quality deterioration of the concrete under hot weather condition. In Korea, Although the period of hot weather concrete in Korea occupies only 2 months, there are a lot of quality problems including plastic, drying shrinkage and cold joint. Therefore, the objective of this paper is to investigate and compare the temperature history and crack occurrence of the concrete, which was placed in the actual apartment house construction field under hot weather condition, in response to the application of surface covered curing blankets including PE film, single layer clear bubble sheet, white colored bubble sheet and aluminum metalized bubble sheet. Test results indicated that the application of white colored bubble sheet and aluminum metalized bubble sheet showed most favorable results in terms of reduction in temperature rise and crack occurrence as well as easiness in handling. But, due to light reflection by aluminum metalized bubble sheet, it is believed that white colored bubble sheet is preferable.

Experimental Performance Study of the Bubble Pump for the Diffusion Absorption Refrigerating System (확산형 흡수식 냉동시스템의 기포펌프 성능실험)

  • 이재효;정의갑;윤재호;정의갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.287-292
    • /
    • 2004
  • An experimental investigation was carried out to study the performance of a bubble pump for the diffusion absorption refrigerating system. Ammonia was used as the refrigerant and the helium was charged in order to balance the pressure between the low and high pressure side. As experimental variables, the concentration of ammonia charged into system, heat input, and the pressure of helium were selected. Experimental results show that the generation rate of ammonia vapor and the circulation rate of diluted ammonia solution were increased as the heat input increases, but the ratio of the solution to vapor flow rate was decreased. The generation rate of refrigerant vapor and the circulation rate of diluted ammonia solution increased as the system pressure decreased. Finally under the condition of 25 bars, the concentration of rich ammonia solution was not affected by the generation rate of ammonia vapor and the circulation of diluted ammonia solution.

Effect of Bubble Size in DAF (DAF에서 기포크기의 영향)

  • Park, Yong-Hyo;Han, Moo-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.528-533
    • /
    • 2003
  • Bubble size is one of the most important parameters affecting DAF (Dissolved-Air-Flotation) process. It is generally known that small bubbles are preferred. However, the fact seems to be based on the particle removal efficiency at contact zone only, without considering separation zone. Besides, the effect of bubble size on the overall DAF process has not been fully investigated yet. Therefore, the effect of bubble size on collision efficiency, collision chances, and surface loading rate is calculated using theoretical models, and the results are discussed in this paper.

Size Characteristics of Micro-bubbles According to Applied Voltage and Electrode materials (전해부상에서 전압과 극판 재질에 따른 미세기포의 크기 특성)

  • Park, Yong-hyo;Han, Moo-young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.16 no.6
    • /
    • pp.663-669
    • /
    • 2002
  • Electro-flotation (EF) has shown advantages, such as a high removal efficiency and easy control of bubble generation, over dissolved air flotation. However, the fundamental characteristics of the process have not been investigated in detail. According to recent modeling results from trajectory analysis, the size of the bubble is one of the most important factors that affect the efficiency of collision between bubble and particle. In this paper, the size characteristics of bubbles generated from EF under various conditions are measured using a new method for bubble size measurement, the Particle Counter Method (PCM). The size of the generated bubbles was found to be constant with respect to applied voltage but to vary with the electrode materials. These results and their implications are discussed.

Thermal Performance of the Bubble Jet Loop Heat Pipe Using Eccentric Heater in Evaporating Section (증발부에 편심 가열부를 사용한 버블젯 루프 히트파이프의 열성능)

  • Kim, Jong-Soo;Kim, Sung-Bok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.12
    • /
    • pp.652-658
    • /
    • 2015
  • The Bubble Jet Loop Heat Pipe (BJLHP) is designed to operate in the horizontal orientation. The motion of the bubble generated by boiling working fluid on a heater surface in the evaporating section of the BJLHP helps the working fluid transfer heat to the condensing portion. In this study, we changed the position of the heater in the evaporating section from concentric to eccentric. The concentric heater is located at the center of the tube in the evaporating part, and the eccentric heater is located at the bottom of the inner surface of the same tube. We used R-134a as the working fluid, and the charging ratio was 50%vol. We measured the temperatures of the evaporating and condensing sections by changing the input electric power from 50 W to 200 W, measuring every 50 W. The results of the experiment show that the effective thermal conductivity of BJLHP using an eccentric heater is four times higher than the BJLHP obtained using a concentric heater. Additionally, we conducted a visualization experiment on the evaporating portion of BJLHP to determine why the effective thermal conductivity was higher. The working fluid was water, and we took pictures of the flow visualization for BJLHP. Nucleate boiling with the eccentric heater was more intense and generated more bubbles. Therefore, the eccentric heater was more saturated by the liquefied working fluid.

A Study on the Bubble Behavior in the Vertical-upward Gas Injection (수직상향 기체주입시 기포거동에 관한 연구)

  • Seo, Dong-Pyo;Oh, Yool-Kwon
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.712-716
    • /
    • 2003
  • In the present study, the gas injection system based on air-water model was designed to investigate the behavior characteristics of bubbles injected into a ladle. The parameters such as gas volume fraction and bubble rise velocity were exprementally measured in a gas-liquid flow region. To measure gas volume fraction, an electo-conductivity probe was used and bubble rise velocity was obtained by a high speed CCD camera. Gas volume fraction was symmetric to the axis of nozzle secured on the bottom of a ladle. The bubble rise velocity was calculated for two different experimental conditions. That is, gas flow conditions were following two case: 1) Q = $0.63{\times}10^{-4}$ $m^{3}/s$, 2) $1.26{\times}10^{-4}$ $m^{3}/s$. As a gas injected into the liquid ladle, the liquid-phase region is circulated by bubbles' behavior. The bubble rise velocity was influenced of the circulation flow of liquid phase. As a result, the bubble rise velocity was appeared higher middle region of ladle than near the nozzle.

  • PDF

Numerical Analysis of Effects of Velocity Inlet and Residual Layer Thickness of Resist on Bubble Defect Formation (레지스트 잔류층 두께와 몰드 유입속도가 기포결함에 미치는 영향에 대한 수치해석)

  • Lee, Woo Young;Kim, Nam Woong;Kim, Dong Hyun;Kim, Kug Weon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.3
    • /
    • pp.61-66
    • /
    • 2015
  • Recently, the major trends of NIL are high throughput and large area patterning. For UV NIL, if it can be proceeded in the non-vacuum environment, which greatly simplifies tool construction and greatly shorten process times. However, one key issue in non-vacuum environment is air bubble formation problem. In this paper, numerical analysis of bubble defect of UV NIL is performed. Fluent, flow analysis focused program was utilized and VOF (Volume of Fluid) skill was applied. For various resist-substrate and resist-mold angles, effects of velocity inlet and residual layer thickness of resist on bubble defect formation were investigated. The numerical analyses show that the increases of velocity inlet and residual layer thickness can cause the bubble defect formation, however the decreases of velocity inlet and residual layer thickness take no difference in the bubble defect formation.

Temperature Effect in the process of DAF as pretreatment of SWRO (해수담수화 전처리로서 DAF공정에서 고온의 해수에 대한 영향 특성)

  • Park, Hyunjin;Dockko, Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.6
    • /
    • pp.807-813
    • /
    • 2012
  • Flocculation and flotation are used as pretreatment steps prior to the reverse osmosis (RO) process. During seawater treatment, high temperature can change the water chemistry of seawater during the process of coagulation. It also affects bubble volume concentration (BVC) and bubble characteristics. Coagulants such as alum and ferric salts at $40^{\circ}C$ can also change flux rates in the seawater reverse osmosis (SWRO) process. In this study, the bubble characteristics in dissolved air flotation (DAF), used as a SWRO pretreatment process, were studied in synthetic seawater at $20^{\circ}C$ and $40^{\circ}C$. The flux of an RO membrane was monitored after dosing the synthetic seawater with coagulants at different temperatures. Results showed that BVC increases as the operating pressure increases and as the salt concentration decreases. The bubble size released at $40^{\circ}C$ is far smaller than that at $20^{\circ}C$The addition of a ferric salt is effective for turbidity removal in synthetic seawater at $20^{\circ}C$; it is more effective than alum. When synthetic seawater was dosed with a ferric salt, the RO membrane flux increased by 27 % at $40^{\circ}C$.

Zeta Potential Measurement of Micro Bubbles Generated by Electrolysis (전기분해(電氣分解)시 알루미늄 극판(極板)에서 발생(發生)한 미세기포(微細氣泡)의 제타전위(電位) 측정(測定))

  • Kim, Won-Tae;Han, Moo-Young;Lee, Sung-Woo;Han, Yi-Seon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.4
    • /
    • pp.343-349
    • /
    • 2000
  • Techniques such as dissolved air flotation and electroflotation, which utilize micro bubbles, are increasingly used for water and wastewater treatment. Most studies have concentrated on particle characteristics. Pretreatments that manipulate particle size and zeta potential were considered important. A recent study, which modeled the collision mechanism between micro bubbles and particles in dissolved air flotation, suggested bubble characteristics should also be important. Hydrogen micro bubbles were generated electrolytically and their zeta potentials measured under various conditions using a novel electrophoresis method. Effects of several parameters were investigated. Bubble zeta potentials were found to be pH dependent, and to have a negative value around neutral pH, becoming zero or positive at lower pH. The pH at zero zeta potential was 5.0 under study conditions. Using artificial solution and tap water, at fixed pH, bubble zeta potentials varied with solution composition. Zeta potentia]s of bubbles were affected by the types of cations and anions in solution but not by the voltage applied. These findings will help improve efficiencies of particle removal processes that utilize micro bubbles. As bubble zeta potential varies with solution composition, it needs to be measured for each composition to understand those effects, which increase removal efficiency.

  • PDF