• 제목/요약/키워드: Air Borne

검색결과 235건 처리시간 0.033초

차량용 에어컨 부밍 소음의 전달 특성에 관한 연구 (A Study on Transfer Characteristics of Vehicle Air-conditioner Booming noise)

  • 임승택;주경훈;안휴남;박영덕;강연준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 춘계학술대회 논문집
    • /
    • pp.476-481
    • /
    • 2013
  • Transfer path analysis(TPA) and operational deflection shape(ODS) have been widely utilized to analyze the characteristics of noise. TPA enables to decompose a noise into air-borne and structure-borne noises then estimate the path contribution of noise. ODS enables to analyze a moving shape and direction of interest components at a particular frequency. In this paper, TPA and ODS are applied to transfer paths of air-conditioner booming noise in a vehicle to reduce noise level, then a fixture is mounted it's path for distributing the high portion path contribution to the low portion path contribution. Through this experiment, the reduction of sound pressure level in air-conditioner booming noise is observed. Thereafter, TPA is again employed to verify the results of contribution.

  • PDF

구조 진동 시스템을 이용한 흡차음재 음향 성능 실험시 공기 층 삽입의 효과 (The Effect of Air gap Insertion in Test Acoustic Performance of Sound Barrier using Structural Vibration System)

  • 신재성;강연중;성명호;김현석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.646-650
    • /
    • 2001
  • In this paper, it is presented that the effect of air gap insertion in testing the transmission loss of sound barrier using structural vibration system. In this study, we use the APAMAT based on the structure-borne-noise. The measured results show that air gap insertion improves transmission loss as results of test based on the air-borne-noise. The measured results are compared with the predicted transmission loss using the transfer matrix method. The predicted results were found to be in reasonable agreement with measured results.

  • PDF

공기감염 전파방지를 위한 UVC 공기살균기 성능평가에 관한 연구 (The Study on the Performance Estimation of UVC Air Sterilizer for Preventing Transmission of Air Borne Contagion)

  • 최상곤;홍진관
    • 설비공학논문집
    • /
    • 제17권6호
    • /
    • pp.581-586
    • /
    • 2005
  • Recently, the use of UVGI system has been increasing in both medical and nonmedical buildings for the control of environmental microorganisms. In the present study, irradiance performance test of UVC lamp was carried out and indoor air sterilization effect of UV ray for preventing transimission of air borne contagion was investigated by using manufactured UVC air sterilizer. Experimental results show that the effective irradiance of UVC lamp is strongly dependent on air velocity and temperature in irradiance performance test. An individual microbiological killing effectiveness experiment also shows that the average kill rate of two microbiological samples such as bacteria and fungus is about $92\%$ by using manufactured UVC air sterilizer. Additionally irradiance performance experimental results also show that the ballast is very important factor to keep up irradiance performance of UVC lamp.

앤티롤바의 취부위치에 따른 철도차량의 실내소음에 대한 연구 (The study of the effects to the structure borne noise in terms of the Anti-Roll Bar's mounting position)

  • 박희준;우관제
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1794-1798
    • /
    • 2008
  • Inside noise level of a running train in open field is the summation of air borne noise and structure-borne noise. Anti-roll bar is the major transmission path of vibration from bogie. And this vibration gives an effect to the structure borne noise. In this paper, the effect of anti-roll bar is investigated. Structure borne noise is analyzed in terms of changing the mounting position of anti-roll bar to reduce inside noise levels.

  • PDF

국내 해안의 비래염분량 조사결과 (Air-borne Chloride Content in Domestic Marine Environment)

  • 정해문;안태송;류종현;안성순
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.66-69
    • /
    • 2003
  • Chloride ingress into concrete followed by reinforcement corrosion and deterioration of concrete structures is a major problem for many structures under chloride attacks. It is necessary to investigate the environmental conditions of concrete structures exposed to chloride attacks. In this study, the air-borne chloride contents in domestic marine environment were investigated.

  • PDF

건축 설비기기 소음의 특성 및 평가에 관한 연구 (A Study on the Evaluation and Characteristics of Architectural Facility-equipment Noise in Building)

  • 변운섭;최둘;김재수
    • 설비공학논문집
    • /
    • 제21권10호
    • /
    • pp.537-544
    • /
    • 2009
  • On account of the technological development, intelligent building is on increasing where the artificial regulation on indoor environment is possible, thence the concern about those facilities such as water-supply facility, water-heater and drainage facility has becomes higher. However, due to diversification and complicated system of the facility-equipments, the noise generating from such facility equipment is gradually becoming a problem, and since especially equipment noises arising at the machine room frequently infringe into the resident's pleasant living environment with the complex types of an air-borne sound and a structure-borne sound, it is becoming the civil complaint. On such viewpoint, this Study ever observed the characteristics of noise generating from various facility-equipments in the building, and intended to evaluate the facility-noises by use of the valuation index such as PSIL, N, NC, NR. As result of, the facilities noise which happens in the machine room makes normal conversation very difficult due to high sound pressure level. Based on such data, this study is willing to present it as an essential material for establishment an efficient measure against the facility-noises arising at machine room hereafter.

무균 돈사 환경 모니터링을 위한 대기 중 미생물 탐지기법 확립 (Optimization of monitoring methods for air-borne bacteria in the environmental conditions of pig facilities)

  • 이덕용;서연수;강상균;유한상
    • 대한수의학회지
    • /
    • 제46권3호
    • /
    • pp.255-261
    • /
    • 2006
  • Experimental animals have been used to biological and medical purposes and the animals must be, for these purposes, healthy and clean to microbial infection. However, the animals can be easily exposed to pathogenic microorganism via several routes. Of the routes, environmental conditions are the most important factors to keep the animals healthy and clean, especially air condition. Monitoring of air-condition has been required to keep the animal healthy and clean. However, any guideline is not available for experimental conditions with pigs. Therefore, the sampling times and points were compared in different conditions to establish an optimal protocol for monitoring of air borne bacteria. Tryptic soy agar(TSA), blood agar containing 5% defibrinated sheep blood and Sabraud dextrose agar(SDA) were used as media to capture total bacteria, pathogenic bacteria and fungi, respectively. Two methods, compulsive capture using an air-sampler and capturing fall-down bacteria were used to capture the microorganisms in the air. The points and time of capturing were different at each experiment. Air borne microorganisms were captured at three and five points in the open and closed equipments, respectively. Air was collected using an air-sampler for 1 min and 5 min and the agar plates as open status were left from 30 min to 2hr. At first, we monitored an experimental laboratory which dealt with several pathogenic bacteria and then, a protocol obtained from the investigation was applied to open or close experimental conditions with pigs. Number of bacteria was high from 10:00 to 15:00, especially on 13:30-15:30 but sharply decreased after 17:00. The tendency of the number of bacteria was similar between two methods even though the absolute number was higher with air sampler. Critical difference in the number of cells was observed at 5 min with air sampler and 2 hr with fall-down capturing method. However, 1 min with air sampler and 1 hr with fall-down capturing were the best condition to identify bacterial species collected from the air. Number of bacteria were different depending on the sampling points in closed condition but not in opened condition. Based on our results, a guide-line was suggested for screening air-borne microorganism in the experimental conditions with pigs.

철골조 공동주택의 차음성능 실태조사에 관한 연구 (I) (A Study on the Sound Insulation Performance of Steel-Structured Apartment Buildings (I))

  • 차상곤;이상우;정병욱;정대업;이수열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.151-156
    • /
    • 2000
  • The sound insulation performance of walls and floors for air-borne and structure-borne sounds in an apartment building is an important environmental factor which should be contemplated at the intial design stage for their thorough control. Recent increasing residents' demands for quality living spaces strongly urge the development of more accurate and efficient measurement and evaluation methods for the control of air-borne and structure-borne sound insulation. However, steel-structured apartment buildings, recently emerged as new building structures in the market, have not been thoroughly examined. The present work carried out an extensive survey for steel-structured apartment buildings, in an attempt to provide useful design data, and their sound insulation performances were compared with those of R.C. apartment buildings.

  • PDF

The Power of "Mass Law"

  • 김정태;김정수;김운경;김석현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.710-714
    • /
    • 2002
  • Whenever a noise problem of a product is concerned, a first step is to identify the energy transmission path whether it is an air-borne or a structure-borne. Depending on the characteristic of the noise path, tools on the noise reduction are different. In this paper. an important aspect of the “mass law” in a noise transmission has been investigated. Since an air-borne has 20 dB/Decade, and a structure-borne 10 dB/Decade of a sound transmission loss due to a mass, an engineer who aims to have a light product design should have an enough knowledge on the mass law, especially, the sensitivity of the weight itself. A honeycomb plate is examined as a sample of a light structure to implement a mass law.

  • PDF

고속 CD-ROM Drive의 구조 및 음장 해석 (Structural and Sound Field Analysis of the High Speed CD-ROM Disk Drive)

  • 임웅섭;차성운;이재승;문용락
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.210-215
    • /
    • 2001
  • CD-ROM Drives Rotating high speed as 10000 rpm cause serious noise and vibration problems. At the high speed, dominant noise is Air Borne Noise produced from high-speed airflow and Structure Borne Noise produced from structural vibration. In this research, vibration and sound characteristics in CD-ROM Drive were studied by the use of experimental analysis and computational simulation. Sound intensity techniques and ODS(Operational Deflection Shape) techniques are applied to identify the acoustic noise source of CD-ROM drive. And Computational simulation using SYSNOISE is conducted for describing the noise behavior.

  • PDF