Fatigue Behavior of Simply Supported Under Reinforcde Concrete Beams (과소철근콘크리트 단수보의 피로거동)

  • 변근주;김영진;노병철;장세창
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1991.04a
    • /
    • pp.41-48
    • /
    • 1991
  • In recent years, conskderable interest has developed in the fatigue strength of reinforced concrete members subjected to cyclic loading for the wide-spread adoption of ultimate strength design poecedures, the higher strength materials and the new recognition of the effect of repeated loading on structures such as bridges, concrete pavementes and offshore structures. In this study, a series of experiments is carried out to investigate the fatigue characteristics of deformed bars and underreinforced simply supported beams. The 69 reinforcing bar specimens with grade SD30 and designation of D16, D22, D25, and 24 beam specimens with D16 bars are prepared for this study. From these series of tests, it is found that I) a decrease of the bar deameter result in increased fatigue life, ii) the fatigue life of the bars embedded as main reinforcement within a concrete is more than that of bars in the air. iii) the fatigue strength at 2$\times$106 cycles of beams with steel ratio of 0.61% and 1.22% is 64.5% and 63.2% of the yielding strength, restectively. It is concluded that the low steel ratio has no significant effect on fatigue strength of underreinforced beams and the fatigue life of underreinforced concrete beams can be predicted conservatively by the fatigue life lf reinforcing bar.

  • PDF

A Study on Improvement of the Performance of Pulsed AC Ion Bar (2) (바 형태 정전기제거장치의 정전기제거성능 향상을 위한 연구 (2))

  • Lee, Dong Hoon;Choi, Dong Soo;Kim, Sang Min;Park, Jin Chul
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.40-45
    • /
    • 2014
  • In display such as LCD, LED, and AMOLED or semiconductor related industries are required to have static ionizer in order to produce reliable goods. The most general type of ionization is called, "corona discharge" that has a slight chances to generate unequal and unstable amount of each +/- ion to the target object. Then, the ionization performance will drastically decrease and end up with quality deterioration problem. continually "A study on the improvement of the performance of pulsed AC ion bar(1)", we have studied consecutive study to improve the current issue via appling "partition wall" at air nozzle surrounding. The results were that the charge decay time and the ion balance was maintained the satisfied range that was within 5 second and ${\pm}50$ V for a 180 days period of time. In additions, the contamination status on the electrode surface was investigated for a 180 days. The little particles was deposited on the electrode surface.

Orthogonality Calibration of a High Precision Stage using Self-calibration Method (자가보정법을 이용한 정밀 스테이지의 직각도 보정)

  • Kim, Ki-Hyun;Park, Sang-Hyun;Kim, Dong-Min;Jang, Sang-Don
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.3
    • /
    • pp.50-57
    • /
    • 2010
  • A high precision air bearing stage has been developed and calibrated. This linear-motor driven stage was designed to transport a glass or wafer with the X and Y following errors in nanometer regime. To achieve this level of precision, bar type mirrors were adopted for real time ${\Delta}X$ and ${\Delta}Y$ laser measurement and feedback control. With the laser wavelength variation and instability being kept minimized through strict environment control, the orthogonality of this type of control system becomes purely dependent upon the surface flatness, distortion, and assembly of the bar mirrors. Compensations for the bar mirror distortions and assembly have been performed using the self-calibration method. As a result, the orthogonality error of the stage was successfully decreased from $0.04^{\circ}$ to 2.48 arcsec.

An Experimental Study on Exhaust Emission in a Gasoline Engine Using PDA and Spark Plug Location (점화플러그 삽입위치와 PDA 밸브를 이용한 가솔린엔진의 배출가스에 대한 실험적 연구)

  • Kim Dae-Yeol;Kim Dae-Yeol;Kim Yang-Sul
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.4
    • /
    • pp.32-40
    • /
    • 2005
  • The purpose of this study is to investigate variation of spark plug protrusion and PDA valve on the exhaust emission in a gasoline engine. Swirl is one of the important parameters that affects the characteristics of combustion. PDA valve has been developed to satisfy requirements of sufficient swirl generation for improving the combustion and reducing of emission level. Also, especially, the variation of spark plug protrusion have an important effect to the early flame propagative process. This is largely due to the high flame speed by short of flame propagation distance. So, this is forced that injection timing, spark timing and intake air motion govern the stable combustion. As a result, using two combustion chamber, without charge of engine specification and the variable spark plug location and PDA valve could be reduced exhaust gas at a part load engine conditions(1500rpm imep 3.9bar, 2000rpm imep 3.2bar, 2400rpm imep 3.9bar).

Effects of combined argon gas treatment on the quality of fresh-cut potatoes (Argon gas 병용처리가 신선편이 감자의 품질에 미치는 영향)

  • Son, Hyun-Ju;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.21 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • The effect of the combined argon (Ar) gas packaging treatment on the browning of fresh-cut potatoes was studied. Fresh-cut potatoes were prepared for the following six groups: dipping distilled water for 1 minute and air packaging (Cont); dipping in distilled water for 1 minute and argon gas packaging (AR); dipping in 1% ascorbic acid for 1 minute and air packaging (AA); dipping in 1% ascorbic acid for 1 minute and argon gas packaging (AAR); blanching at $35^{\circ}C$ for 30 minutes and air packaging (BL); and blanching at $35^{\circ}C$ for 30 minutes and argon gas packaging (BAR). The potatoes were washed, peeled, and sliced ($1.5{\times}1.5{\times}1.5$ cm) before treatment. The samples were packed with a 0.04-mm-thick OPP film and were stored at $5^{\circ}C$ for 9 days. During the storage, the $O_2$ concentration decreased in Cont but increased in the AR, AA, AAR, BL, and BAR groups. The $CO_2$ concentration increased during storage. The AR, AAR, and BAR groups showed high $L^*$ and low $a^*$, $b^*$ values (browning index). The growth of the total aerobic bacteria was also inhibited in the AR group. During storage, the PPO activity gradually increased, and the AR group showed lower PPO activity. The AA and AAR groups showed high DPPH radical scavenging activity. It was demonstrated that the argon gas packaging is effective in the quality maintenance of fresh-cut potatoes.

Design of Vane Rotary Air Compressor for Fuel Cell Application (연료전지용 베인 로타리 공기 압축기 설계)

  • Kim, Hyun-Jin;Lee, Yong-Ho;Kim, Ho-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.2
    • /
    • pp.29-37
    • /
    • 2008
  • Air supply is required to the cathode of fuel cells for the provision of oxygen to produce electricity through chemical reaction with hydrogen in the cell, and supplied air should be free of impurities such as oil mist and tiny particles separated from sliding surfaces. Hence, air compressor for fuel cell air supply must be oil-less type and have no severe sliding surfaces inside. This paper introduces the concept of single-vane type rotary air compressor whose structure is particularly suitable for the fuel cell application: sliding action of the vane against the cylinder wall, which causes severe friction in the conventional vane rotary compressors, is made to be prevented by attaching the vane to the driving shaft with the compliant device between the vane and the rotor in this new design. For 2 kW fuel cell application, preliminary design has been carried out, and its performance has been estimated by using computer simulation program: for discharge pressure of 2 bar, the volumetric, adiabatic, and mechanical efficiencies are calculated to be 82.5%, 92.5%, and 96.3%, respectively.

Determination of an Optimum Orbiting Radius for an Oil-Less Scroll Air Compressor

  • Kim, Hyun-Jin;Lee, Yong-Ho;Kwon, Tae-Hun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.4
    • /
    • pp.124-129
    • /
    • 2008
  • Design practice has been made on an oil-less scroll air compressor as an air supply device for a 2 kW fuel cell system where air pressure of 2 bar and flow rate of 120 liter/min are required. Basic structure of the scroll compressor includes double-sided scroll wrap for the orbiting scroll driven by two crankshafts connected to each other by a timing belt. These features can eliminate thrust surface which otherwise would produce frictional heat and jeopardize reliable operation of the orbiting scroll and the scroll element's deformation as well. This study focuses on optimum scroll wrap design; orbiting radius has been chosen as an independent design parameter. As the orbiting radius changes, scroll sizes such as scroll base plate and discharge port diameters change accordingly. Gas compression-related losses and mechanical loss also change with the orbiting radius. With a scroll base plate diameter of 120mm at most and discharge port of at least 10mm, the orbiting radius should be within the range of 2.5-4.0mm. With this range of the orbiting radius, it was estimated by performance analysis that the compressor efficiency reached to a maximum of ${\eta}_c$=96% at the orbiting radius of $r_s$=3.5mm for the scroll wrap height-to-thickness ratio of h/t=5.

A Study on Detection of Broken Rotor Bars in Induction Motors Using Current Signature Analysis (전류신호를 이용한 유도전동기의 회전자봉 결함검출에 관한 연구)

  • 신대철;정병훈
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.4
    • /
    • pp.287-293
    • /
    • 2002
  • The unexpected failure of the induction motor makes the downtime of production, and the cost of the process cessation enormous. To reduce the downtime and increase the reliability of the motor, the vibration measurements for the fault detection have been used previously. Recently motor current signature analysis(MCSA) has been adapted for the fault detection and diagnosis of the motors. MCSA provides a powerful analysis tool for detecting the presence of mechanical and electrical faults in both the motor and driven equipment. In this paper, the fault severity of the rotor bar has been derived in terms of the resistance change which is calculated from the equivalent circuit model. Results show that the fault of the rotor can be easily detected and the measured value of the resistance change is verified by the detected fault from on-site tests using MCSA for the induction motors in an iron foundry.

A Study on Spray Characteristics Analysis of Free Spray of Diesel Fuel with Ultra High Pressure (극초고압영역에서의 디젤연료의 자유분무특성에 관한 연구)

  • Jeong, D.Y.;Lee, J.T.;Hong, G.B.
    • Journal of ILASS-Korea
    • /
    • v.7 no.4
    • /
    • pp.16-22
    • /
    • 2002
  • The characteristics of free spray with ultra injection pressure was analyzed to clear the limit pressure of diesel engine. To obtain final goal, ultra high pressure injection equipment was developed, spray patterns were visualized under various ultra injection pressures. Spray penetration and spray width, volume and entrained air mass were increased with the increase of injection pressure. Sauter mean diameter and injection durstion wert decreased. But over 3,000bar of ultra injection pressure region the rates of increase show almost similar and finally the reversed tendencies at 4,140bar.

  • PDF

The Study on Performance Characteristics in Freon Refrigeration System using Shell and Disk Type Heat Exchanger (셸앤디스크형 열교환기를 적용한 프레온 냉동장치의 성능특성 연구)

  • Kim, Yang-Hyun;Park, Chan-Soo;Lee, Seong-Jae;Kim, Jin-Hyun;Ha, Ok-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.579-584
    • /
    • 2005
  • Nowadays heat exchangers that have been applied for freon refrigerating systems, a shell and tube type condenser and a flooded evaporator have been used, but because of their large size, large space for installation and amount of refrigerants are needed. In this study, we will find the most suitable operating condition of shell and disk type optimum heat exchanger which can minimize the amount of a refrigerant and allow its minimum leakage. The condensing pressure of refrigeration system is increased from 15.0bar to 16.0bar and degree of superheat is increased from 0 to $10^{\circ}C$ at each condensing pressure. As a result of study, It revealed that shell and disk type heat exchanger was applicable to the freon refrigeration system

  • PDF