• Title/Summary/Keyword: Air -conditioners

Search Result 227, Processing Time 0.027 seconds

Isolation and Identification of Bacteria from Air Conditioners and its Hygiene (에어컨내 세균의 분리, 동정 및 위생)

  • Hong, Seong-Gap;Jeong, Yong-Tae;Cheon, Gyeong-Ho;Baek, Sun-Yeong
    • Korean Journal of Microbiology
    • /
    • v.39 no.4
    • /
    • pp.283-287
    • /
    • 2003
  • This study was performed to identify the microorganisms from air conditioners and to investigate hygiene management on air conditioners. Eight species of bacteria were isolated and identified from twenty samples of coolers in air conditioners; Pantoea sp., Bacillus circulans, Bacillus pumilus, Corynebacterium, Flavimonas oryzihabitans, Ochrobacterum anthropi, Micrococcus sp., and non fermented bacilli (NFB). One thousand and three hundreds twenty-two persons who used air conditioners in their houses were investigated about the state of hygiene management in their air conditioners. One thousand and one hundred thirty eight persons (86%) of the total investigated persons ventilated their air conditioners and 1,128 persons (85%) of them cleaned their air conditioners. However, 864 persons (66%) of them did not clean filters and 1,089 persons (82%) did not clean the heat exchangers, both of which air conditioners could be easily contaminated by microorganisms. From these results, we could conclude that the contaminants, bacteria as mentioned the above, in air conditioners could cause human disease such as respiratory infections if the number of bacteria increase in air conditioners. Thus, the removal of contaminants and the improved hygiene of the air conditioners can prevent human diseases caused by the released bacteria during the use of air conditioners.

The Development of the Certification System for Remote Controlled Air Conditioners (원격제어에어컨 인증시험 장치 개발)

  • Kim, Myong-Soo;Hyun, Duck-Hwa;Cho, Seon-Ku;Kim, Choong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2455-2457
    • /
    • 2001
  • The Remote controlled air conditioner is to effectively suppress the peak load generated from air conditioners in summer. It is important that remote controlled air conditioners are operated well in the real field. Almost 3,200 remote controlled air conditioners has been distributed as of the end of June, 2001. This paper describes a development of the certification system for the air conditioners.

  • PDF

Performance Evaluation of Heat Exchangers due to Air-side Particulate Fouling in the Air Conditioners (공기측 파울링에 의한 에어컨 열교환기의 성능분석 연구)

  • 안영철;조재민;이재근;이현욱;안승표;윤덕현;하삼철;강태욱
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.447-453
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the cooling performance and pressure drop on the air-side particulate fouling of heat exchangers for air conditioners. Air conditioners being used in the field such as inn, restaurant, and office are collected in chronological used order. Test results show 15% decrease of the cooling capacity and 44% increase of the pressure drop for the 7 years air conditioners used in the seaside inn.

Characteristics of the Air-side Particulate Fouling Materials in Finned-Tube Heat Exchangers of Air Conditioners (공기조화기용 열교환기의 공기측 파울링 입자 분석 연구)

  • 안영철;신희수;황유진;이창건;이재근;이현욱;안승표;윤덕현;하삼철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.611-617
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the characteristics of the air-side particulate fouling materials in finned-tube heat exchangers of air conditioners. Air conditioners being used in the field such as inns, restaurants, and offices are collected in chronological order in use. Typical fouling materials on the heat exchangers include fibers and dusts ranged from 6.6 to 20.9 ${\mu}{\textrm}{m}$ in mass median diameter.

A study on the present operation status and the efficient maintenance program of the air-conditioners in each train model (철도차량용 냉방기의 차종별 운용현황고찰과 효율적인 유지보수방안 연구)

  • Hwang, Myeong-Yeon;Sin, Myeong-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.426-430
    • /
    • 2008
  • Though the air-conditioners in each train model have almost identical function, there is incompatibility between them because of their different electric capacity and parts, even spares manufactures are different in the manufactured year. It cause over cost in the maintenance and repair of the each air-conditioner. In this paper, all the air-conditioners in each train model have been classified by their capacity and features so that grasp the operation status and the repair process of the air-conditioners, and draft systematically cost-effective solutions. By finding a way to deal with the emergency repair and extending the air-conditioner life though improvement of checking up progress, increase of passenger revenue can be reached considerably.

  • PDF

A development of direct load control system for air-conditioner (원격제어 에어컨 개발 보급현황 및 향후전망)

  • Gang, Won-Gu;Kim, Choong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2446-2448
    • /
    • 2001
  • In addition to the stabilization of electricity supply and the quality management of electricity, load balance has been an important strategy for achieving high quality load management. Among many techniques for load management, direct load management has been actively studied and applied for increasing the efficiency of power facility and suppressing peak load. In Korea, the highest peak load is demanded in summer rather than in winter, and almost 50% of the peak load comes from cooling load. Currently, applicable systems are limited to air conditioners that have the cooling capacity less than 2kW. This paper describes the development of remote controlled air conditioners and the result of the field test of the new type air conditioner. The technical specification based on the test will be applied to the new model of the remote controlled air conditioner. The wide distribution of the air conditioners to the public will be helpful to control peak demand due to cooling load in summer time. Financial investment to generating, transmission, distribution facilities will be decreased from flatting the seasonal power load.

  • PDF

An Overview on Standards for Seasonal Performance Evaluation of Multi-type Air Conditioners (멀티형 에어컨의 기간에너지소비효율 평가규격에 관한 연구)

  • 박윤철;문제명;홍주태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.91-100
    • /
    • 2004
  • Energy efficiency evaluation method for a multi-type air conditioning system still has not been developed. In this study, analysis on capacity range and evaluating method of standards for air conditioners was conducted with world-wide Standards. It is not a proper approach to use the standards for residential air conditioner to multi type air conditioners. Some difficulties and problems are commented in this study with overview of the standards. Through the analytic research, an evaluating method for multi type air conditioner was suggested with Integrated Part Load Value (IPLV). The suggested concept for evaluating energy efficiency during part load condition considers building load pattern and operating hours of the system at different locations. Load was weighted in IPLV to consider not only the concept of occurrence of outdoor temperature such as bin method but also operation hours of the system. An experiment about the IPLV was conducted with variable air volume ducted type air conditioning system and multi-type system through modified code tester to give a glance at quantitative value of the IPLV.

A Study on the Evaluation of Heating-Conditioned Environment with the Size of Classroom - Focused on Inlet Temperature of Ceiling Type Air-Conditioning System - (교실 규모에 따른 난방 공조환경 평가에 관한 연구 -천장형 냉난방기의 취출온도를 중심으로 -)

  • 최정민;김용이;박효석
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.12
    • /
    • pp.1035-1042
    • /
    • 2003
  • As the desire for a better condition in classroom increases, the distribution rate of warming and cooling conditioners increases. But it is known that according to the way by which the equipments put and are operated the comfortableness felt by persons who are in classroom can make a difference. Therefore, proper equipments in accordance with the size of classroom should be considered as well as operational methods when ceiling warming and cooling conditioners put. This study makes conclusions as follows through a simulation to get improvements in accordance with the size of classroom and to improve the heating performance of ceiling warming and cooling conditioners in classroom.

An Analysis on the Improvement Plan of energy efficiency standard for household refrigerator and air conditioner (냉장고와 에어컨의 에너지 효율 기준 개선 방안 분석)

  • Oh, Min-Hyuk;Baek, Jung-Myoung;Lee, Byung-Ha;Kim, Jung-Hoon;Hwang, Sung-Wook;Won, Jong-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.216-218
    • /
    • 2006
  • Economy of world has grown rapidly. This growth has increased the ownership of household electrical appliances including room air conditioners. The number of users of air conditioners is predicted to grow dramatically in the future. This paper discusses the present status of residential appliance energy efficiency standards around the world. The study found that the energy efficiency standards for room all conditioners would mitigate a significant amount of emissions in Korea.

  • PDF

Performance of Alternative Refrigerants for R12 and R134a in Automobile Air-Conditioners (자동차 공조기용 R12 및 R134a 대체 냉매의 성능평가)

  • Baek, In-Cheol;Park, Ki-Jung;Shim, Yun-Bo;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.5
    • /
    • pp.403-410
    • /
    • 2007
  • In this study, natural refrigerants and their mixtures that can supplement and replace R12 and R134a in automobile air-conditioners are studied. R134a is currently used as the refrigerant in new motor vehicle air conditioners, replacing the ozone depleting refrigerant R12. Although R134a has no ozone depletion potential, it has a relatively large global warming potential, approximately 1300 times that of $CO_2$ over a 100 year time horizon. For this reason, performance of natural refrigerants and their mixtures containing R152a, RE170 (Dimethylether, DME) and R600a (Isobutane) are measured under 2 different temperature conditions. They were tested in a refrigerating bench tester with an open type compressor. The test bench provided about 4 kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. Test results show that the coefficient of performance (COP) of these refrigerants is up to 21.55% higher than that of R12 in all temperature conditions. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for automobile air-conditioners.