Gil, Joo Hyun;Lee, Jung Ah;Kim, Ji Young;Hong, Young Mi
Clinical and Experimental Pediatrics
/
v.51
no.6
/
pp.597-603
/
2008
Purpose : Obesity is associated with insulin resistance. Insulin resistance and the presence of pro-inflammatory mediators are thought to cause a state of vascular endothelial dysfunction, an abnormal lipid profile, hypertension, and vascular inflammation. These chronic inflammatory responses, which are characterized by abnormal cytokine production, lead to activation of a pro-inflammatory signaling pathway. Leptin is an important mediator of inflammatory processes and immune-mediated diseases. The purpose of this study was to investigate the relationship between leptin and various cytokines associated with obesity in adolescents. Methods : Sixty-six obese adolescents (between 16-17 years of age, obesity index >130%) and 26 normal controls were included in this study. Obesity index and body mass index (BMI) were calculated. Serum lipid profile, AST and ALT were tested after 10 hours of fasting. Tumor necrosis factor alpha (TNF-${\alpha}$) and Interleukin-6 (IL-6) levels were measured by ELISA. Insulin, adiponectin, and leptin levels were estimated by radioimmunoassay. Results : Leptin was significantly higher in the obese adolescents compared to the control adolescents ($12.0{\pm}6.8ng/mL$ vs $6.3{\pm}1.0ng/mL$). TNF-${\alpha}$, IL-6, and insulin were significantly higher in the obese adolescents. Adiponectin was significantly lower in the obese group than the control group ($3.3{\pm}1.9{\mu}g/mL$ vs $5.0{\pm}1.4{\mu}g/mL$). Leptin had positive correlations with obesity index, BMI, and IL-6. Conclusion : In obese adolescents, leptin, TNF-${\alpha}$, IL-6, and insulin might be important mediators of obesity. Further clinical research is necessary to ascertain leptin as a predictor of cardiovascular diseases and to develop a guideline for clinical intervention.
Kim, Jung-Su;Rho, Young-Hoon;Lee, In-Ju;Kim, Sung-Su;Kim, Kyoung-Ah;Kim, Jung-Min
Journal of radiological science and technology
/
v.39
no.4
/
pp.527-534
/
2016
Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude.
Park, Mi-Sook;Park, Kyung-Soon;Kim, Kyung-Ah;Cha, Young-Joo;Jun, Myung-Hee;Kim, Tae-Im;Lee, Tae-Soo;Cha, Eun-Jong
The Journal of Korean Academic Society of Nursing Education
/
v.12
no.2
/
pp.265-271
/
2006
Purpose: To analyze the newly developed vacuum assisted auto-lancing technique applied to the forearm for the purpose of obtaining an adequate blood sample for glucose test with minimal pain. Methods: Visual and facial pain measures were introduced to compare lancing pain between the forearm and fingertip in 58 normal females. Sampled blood volumes were accurately measured by computer scanning technique. Results: Visual pain measure demonstrated significant pain reduction effect of the forearm sampling compared with the traditional fingertip sampling, which was also consistent with facial pain measure results. Blood volume more than $0.5{\mu}L$, enough for blood glucose testing with modern glucometers, was collected in 399(86%) of 464 forearm samples. Conclusions: Capillary blood sampling could be performed with minimal pain on the forearm by the newly developed vacuum assisted auto-lancing technique. With some resampling when necessary, the forearm sampling seemed very useful, considering almost no pain felt by the patients.
Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
/
2007.11a
/
pp.510-510
/
2007
Titanate nanotube(TNT)는 높은 비표면적과 우수한 물리화학적 특성을 가지고 있어 광촉매, 수소 저장재료, 태양전지용 전극재료 등에 적용되고 있다. 또한, 티타네이트 나노튜브는 전자 이동이 원활한 구조적 특징을 가지고 있어 리듐 이차전지용 호스트 재료로서 많은 연구가 진행 중이다. 이에 본 연구에서는 저온균일침전법으로 제조한 루틸상 $TiO_2$ 분말에 Lithium chloride를 1~10wt%를 동시에 첨가한 후 10M의 sodium hydroxide 수용액 내에서 수열합성하여 리튬이 도핑된 티타네이트 나노튜브를 제조하였다. 제조된 분말의 입자형상 및 크기는 전자주사 현미경을 이용하여 관찰하였으며, X-선 회절분석을 이용하여 리튬 첨가에 따른 결정상 변화를 관찰하였다. 또한 리튬이 도핑된 티타네이트 나노튜브의 전기화학적 특성 평가를 위해 양극 활물질 : 도전제 : 바인더를 75 : 20 : 5의 비율로 혼합한 후 coin cell을 제조하였고, potentiostat를 이용하여 용량 측정 및 cycle 특성을 실시하였다. 수열 합성법에 의해 형성된 입자는 직경 10nm, 길이 수 ${\mu}m$로 관찰되었으며, X-선 회절 시험 결과 LiO와 같은 이차상은 발견되지 않았다. 측정된 coin cell의 용량은 240mAh/g을 나타내었으나, 싸이클 특성이 빠르게 저하됨을 확인할 수 있었다.
Usually, bacterial spores are hundreds or thousands of times more resistant to chemical sanitizers than are vegetable bacteria. Consequently, it is hard to assess whether a commercial sterilant, containing hydrogen peroxide and peracetic acid as ingredients, has or does not have sporicidal activity under certain conditions using the National Standard Test Method for assessing bactericidal activity against Escherichia coli and Staphylococcus aureus. Hence we established alternative the standard test method and requirements to determine whether they are effective in showing at least reduction of $10^3$ in the number of Bacillus subtilis ATCC 6633 spores under the required test condition for evaluation of sporicidal activity including verification methodology. This standardized method has proved to be suitable for evaluating effectiveness of commercial sterilants and could be used as Standardization Test Method for assessing sporicidal activity.
Journal of the Korean Applied Science and Technology
/
v.33
no.4
/
pp.717-725
/
2016
This study was designed to examine the in vitro antioxidant, antimicrobial and anti-inflammation effects of essential oils of Erigeron annuus L. Flower. Erigeron annuus L. essential oils were obtained by solvent extraction. Antioxidative ability was evaluated by bioassays using ABTS (2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid diammonium salt) radical scavenging effect and 2, 2-diphenyl-1-1-picrydrazyl (DPPH) free radical scavenging activity. Erigeron annuus L. essential oil exhibited free radical scavenging activity on ABTS and DPPH 98.6%, 48.3% respectively, at a concentration of $500{\mu}g/ml$. Antimicrobial activity of essential oils of Erigeron annuus L. were tested against Staphylococcus aureus (S. aureus), Propionibacterium acnes (P. acne) and Escherichia coli (E. coli) by paper disc method, MIC and MBC. Erigeron annuus L. essential oil showed excellent antibacterial activities against S. aureus with MIC and MBC values of 0.31 mg/mL. The clear zone, indicating antimicrobial activity against P. acnes, was 14 mm, MIC and MBC values 0.31 mg/mL, 0.63 mg/mL, respectively. For the anti-inflammatory activity in RAW 264.7 cell, the Erigeron annuus L. essential oils inhibited not only NO production but also the expression of pro-inflammatory cytokines such as, TNF-${\alpha}$, IL-6 in a dose-dependent manner. These results suggested that Erigeron annuus L. essential oils has considerable potential as a cosmetic ingredient with antioxidative, antimicrobial and anti-inflammation effects.
We investigated the quality characteristics and antioxidant capacities of Korean commercial yogurt. Twenty commercial yogurt samples exhibited a pH of 4.05-4.51, titratable acidity of 0.80-1.45%, viable counts of 6.65-9.39 log CFU/g, and total phenolic content of 0.71-2.92 mg gallic acid equivalent/g dry weight (dw). Lactic acid was the major organic acid detected by HPLC with UV detection, and its content was 5.4 times and 46.5 times higher than that of malic acid and citric acid, respectively. The tested commercial yogurt samples exhibited antioxidant potential (1.62-8.95 mM trolox equivalent/g, dw) measured based on scavenging activities of DPPH and ABTS radicals. The average antioxidant potentials of commercial set yogurt containing fruit syrup were significantly (p<0.05) higher than that of cream and plain yogurt. A positive linear correlation was observed between the total phenolic content and the antioxidant capacities, suggesting that phenolic components are likely to contribute significantly to the antioxidant potential of commercial yogurt.
Purpose: This study was to find out whether the rendering screen difference affect to measuring distance in a CAD program according to three types of CAD programs. Materials and methods: The model presented in ISO 12836 for dental scanner evaluation was reduced by 70%. This model was repeatedly scanned 15 times using Trios II (3Shape, Denmark). Using the output STL file, 3Shape CAD, inLab 15, and ExoCAD programs were used to measure the horizontal distance (H) and vertical distance (V) between adjacent point angle, and for each experiment, three groups were set according to the CAD program type. Statistical analysis was performed using One-way ANOVA test and post hoc was performed using Dunnett T3 test. Results: In the horizontal and vertical distance measurement, there was no difference in the average of the measured values between the three groups according to the CAD program (P>.05). Conclusion: There were no effect of the difference in the rendering screen in the horizontal and vertical linear distance measurements of the inlay model on the dental CAD program.
Chemometrics using near-infrared (NIR) and Raman spectroscopy have found significant uses in a variety quantitative and qualitative analyses of pharmaceutical products in complex matrixes. Most of the pharmaceutical can be measured directly with little or no sample preparation using these spectroscopic methods. During pharmaceutical manufacturing process, analytical techniques with no or less sample preparation are very critical to confirm the quality. This study showed NIR and Raman spectroscopy with principal component analysis (PCA) was very effective for the blending processing control. It is of utmost importance to evaluate critical parameters related to quality of products during pharmaceutical processing. The blending is confirmed by off-line determination of active pharmaceutical ingredient (API) by a conventional method such as high performance liquid chromatography (HPLC) and UV spectroscopy. These analytical methods are time-consuming and ineffective for real time control. This study showed the possibility for the determination of blend uniformity end-point of CR tablets with the use of both NIR and Raman spectroscopy. The samples were acquired from six positions during blending processing with U-type blender from 0 to 30 min. Using both collected NIR and Raman spectral data, principal component analysis (PCA) was used to follow the uniformity of blending and finally determine the end-point. The variation of homogeneity of six samples during blending was clearly found and blend uniformity end-point was successfully confirmed in the domains of principal component (PC) scores.
An organic radical polymer (ORP) was prepared by radical polymerization and following oxidation into nitroxyl radical. Two different oxidation methods were employed and their radical concentrations were measured using electroparamagnetic resonance spectroscopy (EPR) and UV-visible absorption (UV-vis) spectroscopy. From these measurements, $H_2O_2-Na_2WO_4$ oxidation method exhibited a complete oxidation, which resulted in 97.6% spin concentration. Also, it was revealed that convenient and cheap UV-vis measurement was useful for preliminary radical concentration comparison. After applied as a cathode material in lithium ion batteries, ORP electrode showed a high initial capacity ($110mAh\;g^{-1}$), a good initial efficiency (96%), a very high rate performance (70% charging during 1.2 min) and stable cycle performance.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.