• 제목/요약/키워드: Aging assessment

검색결과 396건 처리시간 0.026초

Changes of Gait Variability by the Attention Demanding Task in Elderly Adults

  • Yeo, Sang Seok
    • The Journal of Korean Physical Therapy
    • /
    • 제29권6호
    • /
    • pp.303-306
    • /
    • 2017
  • Purpose: Gait variability is defined as the intrinsic fluctuations which occur during continuous gait cycles. Increased gait variability is closely associated with increased fall risk in older adults. This study investigated the influence of attention-demanding tasks on gait variability in elderly healthy adults. Methods: We recruited 15 healthy elderly adults in this study. All participants performed two cognitive tasks: a subtraction dual-task (SDT) and working memory dual-task (WMDT) during gait plus one normal gait. Using the $LEGSys^+$ system, we measured the coefficient of variation (CV %=$100{\times}$[standard deviation/mean]) for participants' stride time, stride length, and stride velocity. Results: SDT gait showed significant increment of stride time variability compared with usual gait (p<0.05), however, stride length and velocity variability did not difference between SDT gait and usual gait (p>0.05). WMDT gait showed significant increment of stride time and velocity variability compared with usual gait (p<0.05). In addition, stride time variability during WMDT gait also significantly increased compared with SDT gait (p<0.05). Conclusion: We reported that SDT and WMDT gait can induce the increment of the gait variability in elderly adults. We assume that attention demanding task based on working memory has the most influence on the interference between cognitive and gait function. Understanding the changes during dual task gait in older ages would be helpful for physical intervention strategies and improved risk assessment.

6.6 kV급 고압전동기 고정자 권선의 절연열화 평가 (Assessment of Insulation Aging in 6.6 kV Class High Voltage Motor Stator Windings)

  • 김희동;김병한
    • 한국전기전자재료학회논문지
    • /
    • 제19권11호
    • /
    • pp.1067-1071
    • /
    • 2006
  • Prior to destructive testing, diagnostic tests were performed in ten high voltage motors. Diagnostic tests included polarization infer, ac current, dissipation factor$(tan{\delta})$ and partial discharge magnitude. The rewind of motet slater insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 8 motor failed near rated voltage of 19.0 kV. The breakdown voltage of No. 4 motet was 7.0 kV which is lower that expected for good quality coils in 6.6 kV class motors. The failure was located in a line-end coil at the exit from the core slot. These two motors began operation in 1994. While testing No. 7 motor, flashover occurred between the stator winding and the stator frame at 15 kV. The relationship between the diagnostic test and the drop in insulation breakdown voltage was analyzed.

Symptom-based reliability analyses and performance assessment of corroded reinforced concrete structures

  • Chen, Hua-Peng;Xiao, Nan
    • Structural Engineering and Mechanics
    • /
    • 제53권6호
    • /
    • pp.1183-1200
    • /
    • 2015
  • Reinforcement corrosion can cause serious safety deterioration to aging concrete structures exposed in aggressive environments. This paper presents an approach for reliability analyses of deteriorating reinforced concrete structures affected by reinforcement corrosion on the basis of the representative symptoms identified during the deterioration process. The concrete cracking growth and rebar bond strength evolution due to reinforcement corrosion are chosen as key symptoms for the performance deterioration of concrete structures. The crack width at concrete cover surface largely depends on the corrosion penetration of rebar due to the expansive rust layer at the bond interface generated by reinforcement corrosion. The bond strength of rebar in the concrete correlates well with concrete crack width and decays steadily with crack width growth. The estimates of cracking development and bond strength deterioration are examined by experimental data available from various sources, and then matched with symptom-based lifetime Weibull model. The symptom reliability and remaining useful life are predicted from the predictive lifetime Weibull model for deteriorating concrete structures. Finally, a numerical example is provided to demonstrate the applicability of the proposed approach for forecasting the performance of concrete structures subject to reinforcement corrosion. The results show that the corrosion rate has significant impact on the reliability associated with serviceability and load bearing capacity of reinforced concrete structures during their service life.

FATIGUE LIFE ASSESSMENT OF REACTOR COOLANT SYSTEM COMPONENTS BY USING TRANSFER FUNCTIONS OF INTEGRATED FE MODEL

  • Choi, Shin-Beom;Chang, Yoon-Suk;Choi, Jae-Boong;Kim, Young-Jin;Jhung, Myung-Jo;Choi, Young-Hwan
    • Nuclear Engineering and Technology
    • /
    • 제42권5호
    • /
    • pp.590-599
    • /
    • 2010
  • Recently, efficient operation and practical management of power plants have become important issues in the nuclear industry. In particular, typical aging parameters such as stress and cumulative usage factor should be determined accurately for continued operation of a nuclear power plant beyond design life. However, most of the major components have been designed via conservative codes based on a 2-D concept, which do not take into account exact boundary conditions and asymmetric geometries. The present paper aims to suggest an effective fatigue evaluation methodology that uses a prototype of the integrated model and its transfer functions. The validity of the integrated 3-D Finite Element (FE) model was proven by comparing the analysis results of individual FE models. Also, mechanical and thermal transfer functions, known as Green's functions, were developed for the integrated model with the standard step input. Finally, the stresses estimated from the transfer functions were compared with those obtained from detailed 3-D FE analyses results at critical locations of the major components. The usefulness of the proposed fatigue evaluation methodology can be maximized by combining it with an on-line monitoring system, and this combination, will enhance the continued operations of old nuclear power plants.

Setting a Direction for United States Water Policy

  • Reid, Kenneth D.;Engberg, Richard A.
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.121-121
    • /
    • 2010
  • The water resources of the United States are increasingly at risk and the nation's water policy is in serious difficulty. Water resources protection laws primarily passed since 1950 often contradict water resources development laws passed before 1950. These contradictions complicate efficient and effective responses to the nation's water resources challenges including climate change, our aging infrastructures, changing population dynamics, drought, floods, wetlands and aquatic species loss, ecosystem restoration and many others. In addition, water law and policy determination, management and enforcement are so broadly distributed between, local, state and federal responsibilities that effective responses again are difficult. For example, at the national level alone, more than a dozen federal agencies have water resources responsibilities including resource development, resource assessment, and resource protection. They are presided over by six cabinet (Ministerial) departments, at least 13 congressional (parliamentarian) committees and 23 subcommittees, and are funded by five appropriations subcommittees. Lastly, good science and the public accountability associated with it are often overshadowed by political considerations at local, state and federal levels. The United States approach to solving water resources challenges is ad hoc - we address problems as they appear or as they merit political support rather than using good science to address our long term water resources needs.

  • PDF

Assessment of 23 kV Capacitive Coupler for On-line Partial Discharge Measurements

  • Jeong, J.Y.;Kang, D.S.;Sun, J.H.;Heo, J.C.;Park, C.H.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.123-130
    • /
    • 2009
  • The partial discharge (PD) measurement is a very effective method to assess the winding insulation condition of high-voltage machines, since most of the insulation failure processes are directly or indirectly caused by PD. On-line PD measurements, which can detect insulation defects of winding in the early stages on rotating machines in operation, have been accepted as the most important technique. The epoxy mica capacitive coupler is currently and extensively used for on-line detection of PD pulses of high-voltage rotating machines. To evaluate the feasibility of developing a capacitive coupler that is easier to manufacture at a lower cost compared to epoxy mica couplers, a 100pF capacitive coupler made of ceramic material is designed, fabricated and tested for on-line PD measurements of 23 kV electrical machines. A series of electrical tests and accelerated aging tests are performed on the ceramic coupler to evaluate the performance requirements, long-term reliability and thermal stability for in field application. The test results show that the newly developed ceramic coupler provides equal and improved performance at a lower cost compared to epoxy mica couplers, and estimated voltage life is anticipated to surpass 100 years.

완화전류 측정에 의한 지중배전케이블의 열화진단 (Aging Diagnosis of Underground Distribution Power Cables by Isothermal Relaxation Current Measurement Equipment)

  • 김주용;송일근;김동명;윤태상;정상봉
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.502-505
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this papar we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

  • PDF

송전용 36,000 lbs 자기애자의 수명 예측 연구 (A Study of Life Prediction Assessment of T/L 36,000 Ibs Porcelain Insulators)

  • 최인혁;최연규;이동일;이원교;강병규;박준호
    • 한국전기전자재료학회논문지
    • /
    • 제20권7호
    • /
    • pp.636-644
    • /
    • 2007
  • 36,000lbs porcelain insulators of D-1995, D-1997 and D-2002 investigated mechanical and electrical qualities, where is process of using in the Korea 154 kV transmission lines. It analyzes the cause of the elapse of a year aging of the transmission insulators. Weibull distribution function, product quality and uniform quality, etc. investigated for prediction to extant life of insulator. It calculate change as statistical elapse of a year through product qualities of used insulator and new insulator, uniform equality and uniformity of insulator. In case of D-1995 year used insulator, it decided to badness decline index k by 0.0237, badness quality index by 1.0 and 3.0. Result of extant confidence life Ym was calculated that remain each 4 yens and 0.7 yens that uniformity index is considered. Extant life of D-1997 and D-2002 insulators Predicted by about 40 years.

초음파 전파특성을 이용한 열가소성 합성수지의 열화 평가 (Degradation Assessment of Thermoplastic Synthetic Resin Using Propagation Characteristics of Ultrasound)

  • 전우상;김기진;권성덕
    • 비파괴검사학회지
    • /
    • 제34권2호
    • /
    • pp.141-147
    • /
    • 2014
  • 경제성과 함께 다양한 기능성으로 유리 및 금속제를 대체하고 있는 고분자 합성수지인 플라스틱(plastic) 재료의 열화(thermal degradation) 및 열적 특성을 비파괴적으로 평가하기 위하여 초음파의 전파특성(속도 및 감쇠)이 사용되었다. 플라스틱 재료중 범용 열가소성 재료인 높은 투명도의 아크릴 수지(PMMA)에 대해 유리전이온도($T_g$) 범위내에서 열화온도 및 열화시간에 따른 다양한 열화시편에 대해 전파특성 변화가 측정되었다. 열화가 진전될수록 감쇄는 증가하였고 속도는 감소함을 보였으며, 초음파 전파특성의 측정을 통해 열가소성 플라스틱 재료의 정량적 열화평가 및 유리전이온도($T_g$) 영역의 정성적 추정이 가능하였다.

Morphological segmentation based on edge detection-II for automatic concrete crack measurement

  • Su, Tung-Ching;Yang, Ming-Der
    • Computers and Concrete
    • /
    • 제21권6호
    • /
    • pp.727-739
    • /
    • 2018
  • Crack is the most common typical feature of concrete deterioration, so routine monitoring and health assessment become essential for identifying failures and to set up an appropriate rehabilitation strategy in order to extend the service life of concrete structures. At present, image segmentation algorithms have been applied to crack analysis based on inspection images of concrete structures. The results of crack segmentation offering crack information, including length, width, and area is helpful to assist inspectors in surface inspection of concrete structures. This study proposed an algorithm of image segmentation enhancement, named morphological segmentation based on edge detection-II (MSED-II), to concrete crack segmentation. Several concrete pavement and building surfaces were imaged as the study materials. In addition, morphological operations followed by cross-curvature evaluation (CCE), an image segmentation technique of linear patterns, were also tested to evaluate their performance in concrete crack segmentation. The result indicates that MSED-II compared to CCE can lead to better quality of concrete crack segmentation. The least area, length, and width measurement errors of the concrete cracks are 5.68%, 0.23%, and 0.00%, respectively, that proves MSED-II effective for automatic measurement of concrete cracks.