• 제목/요약/키워드: Aged pipe rate

검색결과 7건 처리시간 0.022초

수도사업자의 주요 운영지표와 ILI(Infrastructure Leakage Index)와의 상관관계 분석 (Correlation analysis of key operating indicators of waterworks with the Infrastructure Leakage Index (ILI))

  • 전승희;현인환;김두일
    • 상하수도학회지
    • /
    • 제35권3호
    • /
    • pp.237-246
    • /
    • 2021
  • The ILI, developed by the IWA (International Water Association), has been used in many countries as an indicator of water leakage. In Korea, the revenue water has been used as a performance indicator for waterworks although there is an opinion to replace it with the ILI. Hence, it has been necessary to investigate whether the ILI can replace the revenue water in Korea. The four main operating indicators (i.e., water service population, profit-loss ratio, fiscal self-reliance, and aged pipe rate) of 162 Korean waterworks were compared with the ILI with the linear regression method. Local water authorities with more than 1 million water service population, with more than 60% profit-loss ratio, more than 40% and less than 60% fiscal self-reliance, and more than 20% aged pipe rate showed meaningful correlation between the four parameters and the ILI. In the remaining cases, their correlations were little or weak. This means that using the ILI may not be an efficient method to represent the performance of the water supply system in Korea because of the lack of UARL (Unavoidable Annual Real Losses) data accuracy. To use the ILI in Korea, it will be required to carry out an additional research to accumulate reliable CARL (Current Annual Real Losses) and UARL data in the future.

이음매 없는 304L 스테인리스강관의 부식특성에 미치는 열처리의 영향 (Effect of Heat Treatment on the Corrosion Properties of Seamless 304L Stainless Steel Pipe)

  • 김기태;엄상빈;김영식
    • Corrosion Science and Technology
    • /
    • 제16권6호
    • /
    • pp.305-316
    • /
    • 2017
  • Austenitic stainless steels have been widely used for various systems of nuclear power plants. Among these stainless steels, small pipes with diameter less than 14 inch have been produced in the form of seamless pipe. Annealing and cooling process during the manufacturing process can affect corrosion properties of seamless stainless steels. Therefore, 12 inch-diameter of as-received 304L stainless steel pipe was annealed and aged in this study. Intergranular corrosion resistance was evaluated by ASTM A262 Practice A, C, and E methods. The degree of sensitization was determined using a DL-EPR test. U-bend method in an autoclave was used to evaluate the SCC resistance in 0.01 M $Na_2S_4O_6$ or 40% NaOH solution at $340^{\circ}C$. As-received specimen showed relatively high degree of sensitization and intergranular corrosion rate. Carbon segregation was also observed near grain boundaries. Annealing treatment could give the dissolution of segregated carbon into the matrix. Aging treatment could induce segregation of carbon and finally form carbides. Microstructural analysis confirmed that high intergranular corrosion rate of the as-received seamless pipe was due to micro-galvanic corrosion between carbon segregation and grains.

직류전위차법을 이용한 AISI 316강 시효재의 탄소성 파괴인성 평가 (Evaluation of Elastic-Plastic Fracture Toughness of Aged AISI 316 Steel Using DC-electric Potential Method)

  • 임재규;장진상
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.519-527
    • /
    • 1997
  • AISI 316 steel has been used extensively for heater and boiler tube of the structural plants such as power, chemical and petroleum plants under severe operating conditions. Usually, material degradation due to microcrack or precipitation of carbides and segregation of impurity elements, is occured by damage accumulated for long-term service at high temperature in this material. In this study, the effect of aging time on fracture toughness was investigated to evaluate the measurement of material degradation. The elastic-plastic fracture toughness behaviour of AISI 316 steel pipe aged at $550^{\circ}C$for 1h-10000h (the aged material) was characterized using the single specimen J-R curve technique and eletric potential drop method at normal loading rate(load-line displacement speed of 0.2mm/min) in room temperature and air environment. The fracture toughness data from above experiments is compared with the $J_{in}$ obtained from predicted values of crack initiation point using potential drop method.

개미군집 최적화 알고리즘을 이용한 상수도관망 시스템의 최저비용설계 모델의 현장 적용 (Field Application of Least Cost Design Model on Water Distribution Systems using Ant Colony Optimization Algorithm)

  • 박상혁;최홍순;구자용
    • 상하수도학회지
    • /
    • 제27권4호
    • /
    • pp.413-428
    • /
    • 2013
  • In this study, Ant Colony Algorithm(ACO) was used for optimal model. ACO which are metaheuristic algorithm for combinatorial optimization problem are inspired by the fact that ants are able to find the shortest route between their nest and food source. For applying the model to water distribution systems, pipes, tanks(reservoirs), pump construction and pump operation cost were considered as object function and pressure at each node and reservoir level were considered as constraints. Modified model from Ostfeld and Tubaltzev(2008) was verified by applying 2-Looped, Hanoi and Ostfeld's networks. And sensitivity analysis about ant number, number of ants in a best group and pheromone decrease rate was accomplished. After the verification, it was applied to real water network from S water treatment plant. As a result of the analysis, in the Two-looped network, the best design cost was found to $419,000 and in the Hanoi network, the best design cost was calculated to $6,164,384, and in the Ostfeld's network, the best design cost was found to $3,525,096. These are almost equal or better result compared with previous researches. Last, the cost of optimal design for real network, was found for 66 billion dollar that is 8.8 % lower than before. In addition, optimal diameter for aged pipes was found in this study and the 5 of 8 aged pipes were changed the diameter. Through this result, pipe construction cost reduction was found to 11 percent lower than before. And to conclusion, The least cost design model on water distribution system was developed and verified successfully in this study and it will be very useful not only optimal pipe change plan but optimization plan for whole water distribution system.

Smoking and Associated Factors Among the Population Aged 40-64 in Shahroud, Iran

  • Hamrah, Mohammad Shoaib;Harun-Or-Rashid, Md.;Hirosawa, Tomoya;Sakamoto, Junichi;Hashemi, Hassan;Emamian, Mohammad Hassan;Shariati, Mohammad;Fotouhi, Akbar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권3호
    • /
    • pp.1919-1923
    • /
    • 2013
  • Background: Smoking is known as a major risk factor for different types of cancer, as well as cardiovascular disease. Its prevalence is increasing in developing countries. The aims of this study were to determine the prevalence of smoking and its associated factors among the population aged 40-64 years in the city of Shahroud which is a representative urban population in Iran. Materials and Methods: A cross-sectional population-based study with stratified random cluster sampling was conducted in 2009 as the first phase of Shahroud Eye Cohort Study. Of 6,311 people, 5,190 participated (82.2%). Information about smoking habit was obtained by face-to-face interview. Results: The overall prevalence of current tobacco smoking was 11.3% (95%CI: 10.5-12.3). It was significantly higher among males than females (25.7% and 0.71%, P<0.001). The prevalence of current cigarette smoking was 10.8% and 1.75% were past smokers. The smoking rate of water-pipe was 0.67%. Unemployed people smoked more than employed (OR=2.66, 95%CI: 1.38-5.14). Conclusions: The prevalence of smoking is low in Shahroud compared with other parts of Iran and other countries. Age, sex, job and marital status were associated with smoking. The low smoking rate among women may be attributed to cultural and social reasons.

Acute Effects of Dokha Smoking on the Cardiovascular and Respiratory Systems among UAE Male University Students

  • Shaikh, Rizwana B.;Haque, Noor Mohammad Abdul;Al Mohsen, Hassan Abdul Hadi Khalil;Al Mohsen, Ali Abdul Hadi Khalil;Humadi, Marwa Haitham Khalaf;Al Mubarak, Zainab Zaki;Mathew, Elsheba;Al Sharbatti, Shatha
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권5호
    • /
    • pp.1819-1822
    • /
    • 2012
  • Background: In the United Arab Emirates (UAE) tobacco use is rampant. A less reported, yet widely used form of smoking native to UAE is midwakh or dhokha. The aim of the study is to assess the acute effects of smoking dokha (Arabian pipe) on the cardiovascular and respiratory systems among male university students in the UAE. Method: A quasi-experimental study was conducted among 97 male volunteers aged more than 17 years. Blood pressure, heart rate and respiratory rate of each participant, were measured before and immediately after smoking. A self administered questionnaire was used to collect personal details and data about smoking pattern. Results: Mean increases in systolic blood pressures ($12{\pm}1$ mmHg), heart rates ($20{\pm}2$ bpm) and respiratory rates ($4{\pm}1$ breaths/min) were observed (p < 0.001). A mean decrease in diastolic blood pressures ($1{\pm}1$ mmHg) was observed (p = 0.483). Conclusion: Smoking dokha has a significant acute effect on systolic blood pressure, heart rate and respiratory rate. Anti smoking campaigns must address the ill effects of this form of smoking. Results from the study warrant further research into this method of smoking which is becoming more popular.

$10{\sim}50$년이 경과한 콘크리트구조물의 사용 용도별 탄산화 현상에 의한 열화도 판정 (Investigation on Carbonation Phenomenon of Type of Use for Concrete Structures aged a decade to fifty years)

  • 박현;김광기;한다희;김성진;임남기;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.1017-1020
    • /
    • 2008
  • 콘크리트구조물에서의 탄산화 현상은 단독 또는 복합적으로 작용하고 사용환경의 조건에 따라 각각 상이한 탄산화 현상을 나타나게 된다. 이에 본 연구에서는 사용연수가 $10{\sim}60$여년이 경과되고 사용환경이 상이한 건축물과 토목구조물에 대하여 탄산화 깊이와 알칼리 농도를 측정하여 열화 정도를 판단하였다. 그 결과 건축물(옥내)은 외기에 노출된 토목구조물 보다 빠르고 해안가에 근접 할수록 열화현상이 심화된 것으로 나타났다. 또한, 공동구 또는 지하터널 보다는 하수암거의 용도로 사용하는 콘크리트구조물에서의 열화현상이 큰 것으로 조사되었다.

  • PDF