• 제목/요약/키워드: Age of Building

검색결과 781건 처리시간 0.032초

적산온도 방법을 활용한 초지연 모르타르의 응결특성 고찰 (Setting Time of Super-Retarding Mortar Applying Maturity)

  • 한수환;임군수;현승용;윤치환;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.229-230
    • /
    • 2021
  • This study is conducted to identify the setting time of mortar mixed with super retarding agent as a series of studies to predict setting time based on the equivalent age method. The experimental results showed that mixing super-retarding agents did not adversely affect the quality of mortar, and the equivalent age calculation showed similar results regardless of curing temperature.

  • PDF

고로슬래그 미분말의 치환율을 고려한 압축강도예측모델에 관한 실험적 연구 (An Experimental Study on the Prediction Model for the Compressive Strength of Concrete according to Replacement Ratio of Ground Granulated blast-furnace slag)

  • 양현민;박원준;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.89-90
    • /
    • 2013
  • This study is to predict the compressive strength for the concrete of ground granulated blast-furnace slag, and use Plowman's, Gompertz's model. The results are as follows; The prediction compressive strength were simiar using Rastrup's equivalent age model. but The prediction compressive strength using Freiesleben's equivalent age model weren't simiar in bfs replacement Ratio of 50%, because it is analyzed as the activation energy.

  • PDF

초기재령에서 보통 및 경량골재 콘크리트의 경과시간에 따른 압축강도 및 초음파 펄스 속도의 평가 (Evaluation of Compressive Strength and Ultrasonic Pulse Velocity according to Elapsed Time on Normal and Lightweight Aggregate Concrete at Early Age)

  • 김원창;최형길;남정수;김규용;이태규
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.409-410
    • /
    • 2023
  • In this study, the compressive strength and ultrasonic pulse velocity were evaluated according to the elapsed time on concrete mixed with normal and lightweight aggregates at early age. For evaluation in various strength ranges, the design compressive strength was set to 30, 45, and 60MPa and evaluated. As a result of the experiment, the compressive strength of concrete mixed with lightweight aggregates developed 5MPa earlier compared to normal aggregate concrete, and the UPV showed a similar tendency.

  • PDF

고효율 로이유리 창호의 정량적 단열성능 평가 (An Evaluation for the Quantitative Thermal Performance of High Energy Efficiency Low-e Window)

  • 최경석;최현중;강재식;양관섭;이숭언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.970-975
    • /
    • 2006
  • In the high oil prices age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating large percentage whole building loads, and are regarding as the primary target of energy efficiency. The purpose of this study is to draw up a technical counterplan for the intensification of windows energy efficiency and spread promotion by quantitative thermal performance with KS test method for a comparison between the general Pair glass windows and the Low-e pair glass windows.

  • PDF

신뢰 및 충성도 구축 메커니즘에서 유대전략과 점포 운명기간의 상호작용 효과에 관한 연구 (The Study on the Interactive Effects of Bonding Tactics and Store's Age on Building Mechanism of Trust and Loyalty)

  • 유동근;서승원;이동일
    • 한국유통학회지:유통연구
    • /
    • 제13권2호
    • /
    • pp.29-57
    • /
    • 2008
  • 본 연구는 유통경로 상에서 서비스기업의 공급업체에 대한 신뢰 및 충성도 구축과정에서 공급업체의 유대관계전략과 서비스기업의 점포 운영기간 사이에 상호작용효과를 실증적으로 분석하였다. 실증을 위해 한국동물병원협회 소속의 214개 동물병원을 표본으로 하여 설문을 수집한 후, 구조방정식 모델을 활용하여 가설을 검증하였다. 실증분석의 결과는 다음과 같다. 첫째, 유통경로 구성원인 공급업체의 서비스기업에 대한 유대관계 전략에 따라 서비스기업이 구축하고자하는 신뢰의 유형에 대해 서로 다른 영향을 주는 것을 확인하였다. 즉, 공급업체의 사회적 유대전략은 서비스기업의 두 가지 유형의 감정적 신뢰 및 인지적 신뢰구축에 모두 영향을 주지만, 구조적 유대전략은 서비스기업의 감정적 신뢰에 영향을 주지만 인지적 신뢰에는 영향을 주지 않았다. 둘째, 공급업체의 사회적 유대전략은 서비스기업의 공급업체에 대한 충성도 구축에 직접적인 영향을 미치지만, 구조적 유대는 충성도 구축에 직접적으로 영향을 미치지 않고 감정적인 신뢰를 통하여 영향을 미쳤다. 셋째, 서비스기업의 감정적 신뢰는 그들의 공급업체에 대한 충성도 구축에 직접적인 영향을 주지만, 서비스기업의 인지적 신뢰는 공급업체에 대한 충성도 구축에 직접적인 영향을 주지 않고 감정적 신뢰를 통하여 형성되었다. 넷째, 서비스기업의 점포 운영기간이 길수록 공급업체는 사회적 유대를 활용하여 서비스기업의 신뢰 및 충성도를 직접적으로 구축하나, 점포 운영기간이 짧을수록 사회적 유대 및 구조적 유대를 부분적으로 활용하여 신뢰를 먼저 구축하고 그런 다음 충성도를 간접적으로 구축하였다. 따라서 유통경로 구성원들 사이에 서비스기업이 그들의 사업파트너인 공급업체에 대한 신뢰의 유형 및 충성도를 구축하기 위해서 서로 다른 유대관계 전략을 활용하며, 공급업체는 서비스 기업의 점포 운영기간에 따라 공급업체에 대한 서비스기업의 신뢰 및 충성도를 구축하는 과정에서 해당점포의 운영기간에 대한 상호작용효과를 고려할 필요가 있다. 마지막으로 연구의 시사점, 한계점 그리고 향후 연구방향에 대해 논의하였다.

  • PDF

경년변화에 따른 우리나라 서중 콘크리트 적용기간의 변천 (Variation of the Period of Hot Weather Concrete with Elapse of Age in Korea)

  • 최성용;홍석민;이충섭;김성일;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 추계 학술논문 발표대회
    • /
    • pp.53-56
    • /
    • 2008
  • This paper is to investigate the change of the period of hot weather concrete with elapse of age based on climate data. Climate data for 30 years and 5 years are used respectively. Determination of the period of hot weather concreting on architectural execution in Korea according to the specifications of AIJ, KSCE, and ACI are discussed. According to the research, the period of hot weather concreting with each specification in most regions lasts over 35 days. Compared with the period of cold weather concreting in hillside and inland area, coastal areas have shorter period in the same latitude. The period of hot weather concreting tends to decrease with high latitude. As expected, with the elapse of age, the period of hot weather concrete exhibited to decrease, especially, big city like Seoul, Busan etc had remarkably increased period by as much as a week. This is due to the global warming and industrialization effect with the elapse of age.

  • PDF

고온조건하에서 플라이애시를 사용한 콘크리트의 압축강도증진 해석 (Estimation of Compressive Strength of Fly Ash Concrete subjected to High Temperature)

  • 한민철
    • 한국건축시공학회지
    • /
    • 제6권3호
    • /
    • pp.99-105
    • /
    • 2006
  • In this paper, the estimation of compressive strength of concrete incorporating fly ash subjected to high temperature is discussed. Ordinary Portland cement and fly ash cement(30% of fly ash) were used, respectively. Water to binder ration ranging from 30% to 60% and curing temperature ranging from $20^{\circ}C{\sim}65^{\circ}C$ were also adopted for the experimental parameters. According to results, at the high temperature, FAC had higher strength development at early age than OPC concrete and it kept its high strength development at later age due to accelerated pozzolanic reaction subjected to high temperature. For strength estimation, Logistic model based on maturity equation and Carino model based on equivalent age were applied to verify the availability of estimation model. It shows that fair agreements between calculated values and measured values were obtained evaluating compressive strength with logistic curve. The application of logistic model at high temperature had remarkable deviations in the same maturity. Whereas, the application of Carino model showed good agreements between calculated values and measured ones regardless of type of cement and W/B. However, some correction factors should be considered to enhance the accuracy of strength estimation of concrete.

Analysis on the Age of Air and the Air Change Effectiveness of the Personal Environmental Module System in Intelligent Buildings

  • Cho, Dongwoo
    • Architectural research
    • /
    • 제1권1호
    • /
    • pp.47-53
    • /
    • 1999
  • An interesting of desktop air-conditioning system is the Personal Environmental Module(PEM) System. The PEM system allows the occupant to choose the desired temperature, air volume and direction of the discharged air. In this study, the measurements on the age of air and the air change effectiveness, using the tracer gas method, are carried out to analyze the ventilation performance for provision of fresh air near the breathing zone by the PEM. The relations between the PEM for optimal control and other factors related to indoor air quality, and the ventilation for the PEM are examined. Also, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The minimum local age of air was measured in the breathing zone, which is directly supplied with air from the PEM diffusers, and the measured local air change effectiveness of the desktop diffuser in the breathing zone was about 1.13 to 1.23 times greater than that of the ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

Experimental study on deformation of concrete for shotcrete use in high geothermal tunnel environments

  • Cui, Shengai;Liu, Pin;Wang, Xuewei;Cao, Yibin;Ye, Yuezhong
    • Computers and Concrete
    • /
    • 제19권5호
    • /
    • pp.443-449
    • /
    • 2017
  • Taking high geothermal tunnels as background, the deformation of concrete for shotcrete use was studied by simulating hot-humid and hot-dry environments in a laboratory. The research is made up by two parts, one is the influence of two kinds of high geothermal environments on the deformation of shotcrete, and the other is the shrinkage inhibited effect of fiber materials (steel fibers, polypropylene fibers, and the mixture of both) on the concrete in hot-dry environments. The research results show that: (1) in hot and humid environments, wet expansion and thermal expansion happened on concrete, but the deformation is smooth throughout the whole curing age. (2) In hot and dry environments, the concrete suffers from shrinkage. The deformation obeys linear relationship with the natural logarithm of curing age in the first 28 days, and it becomes stable after the $28^{th}$ day. (3) The shrinkage of concrete in a hot and dry environment can be inhibited by adding fiber materials especially steel fibers, and it also obeys linear relationship with the natural logarithm of curing age before it becomes stable. However, compared with no-fiber condition, it takes 14 days, half of 28 days, to make the shrinkage become stable, and the shrinkage ratio of concrete at 180-day age decreases by 63.2% as well. (4) According to submicroscopic and microscopic analysis, there is great bond strength at the interface between steel fiber and concrete. The fiber meshes are formed in concrete by disorderly distributed fibers, which not only can effectively restrain the shrinkage, but also prevent the micro and macro cracks from extending.

아파트의 실내외 공기질 향상을 위한 주동 배치 계획 연구 (A Study on the Site Planning of an Apartment Complex for Improving the Outdoor and Indoor Air Quality)

  • 신지웅;김태연;이경회
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.195-202
    • /
    • 2004
  • This study focuses on the impacts of apartment building arrangements on the outdoor and indoor air quality - the efficiency of natural ventilation in the outside/inside area of an apartment with consideration to the characteristics of an air flow in outside area depending on the types of the arrangements, the main direction of the wind, and the outside wind pressure on the building facade. As indices to evaluate the efficiency of natural ventilation, the concepts of "Age of Air" and "Purging Flow Rate(PFR)" were used in this study. As indices to classify the efficiency of indoor natural ventilation, the mean values of the wind pressure differences between the front and the back elevations of an apartment building were used. The research showed that the PFR of each apartment building arrangement ranges from 0.867 to 3.253. The "minus-shaped" arrangement showed the highest PFR, 2.306; the "zigzag-shaped" arrangement measured 1.889; the "angle-shaped" arrangement measured 1.465, and the "square-shaped" arrangement measured 1.241. Depending on the direction of the wind, the pressure differences range extremely, with variations from 170% to 2300%. Thus, the indoor natural ventilation efficiency can be changed by the pressure differences of the wind, which are sensitive to the main direction of the wind even though the structure and planning of the apartment complexes are the same. Despite the same direction of the wind, even the efficiency can be diverse. This study showed how to predict the most beneficial apartment building arrangement for the profitable natural ventilation efficiency in each direction of the wind.