• Title/Summary/Keyword: Ag-paste

Search Result 223, Processing Time 0.028 seconds

Determination of Fluoroquinolone Antibacterial Agents by Square Wave Adsorptive Stripping Voltammetry (네모파 흡착 벗김 전압전류법에 의한 플루오로퀴놀론 계 항생제의 검출)

  • Boo, Han-Kil;Song, Youn-Joo;Park, Se-Jin;Chung, Taek-Dong
    • Journal of the Korean Electrochemical Society
    • /
    • v.13 no.1
    • /
    • pp.63-69
    • /
    • 2010
  • Electrochemical behavior of fluoroquinolone antibacterial agents on carbon paste electrode (CPE) were investigated by cyclic voltammetry and square wave adsorptive stripping voltammetry. The fluoroquinolone antibacterial agents tested in this study were Enrofloxacin (ENR), Norfloxacin (NOR), Ciprofloxacin (CIP), Ofloxacin (OFL) and Levofloxacin (LEV). In acetate buffer at pH 4.5, the oxidation peak potentials of the fluoroquinolone antibacterial agents of ENR, NOR, CIP, OFL, and LEV were 0.952 V, 1.052 V, 1.055 V, 0.983 V, and 0.990 V (vs. Ag/AgCl), respectively. And their oxidation peak currents from square wave adsorptive stripping voltammograms are proportional to the concentration of each antibacterial agent over the range from $0.2\;{\mu}M$ to $1\;{\mu}M$.

고출력용 인쇄회로기판을 위한 무전해 니켈 도금막의 특성 연구

  • Yun, Jae-Sik;Jo, Yang-Rae;Kim, Hyeong-Cheol;Samuel, Tweneboah-Koduah;Lee, Yeon-Seung;Na, Sa-Gyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.322-322
    • /
    • 2013
  • 최근 전자제품들의 소형화, 경량화, 다기능화가 활발히 진행됨에 따라, 고성능의 고출력용 인쇄회로기판(PCB)의 개발이 요구되고 있다. PCB는 전자제품의 각 부품을 전기적으로 연결하는 통로로서 전자제품의 소형화, 다기능화에 따라 고집적화가 요구되고 있다. 하지만 모든 전자장비의 고장의 85% 정도가 발열에 의한 것으로, PCB의 고집적화에 따른 발열문제가 매우 중요한 이슈가 되고 있다. 최근에는 이러한 문제점을 해결하기 위해 PCB의 방열층으로 양극 산화막을 금속 기판 위에 형성하고 이 절연층 위에 금속층을 회로로서 형성하는 방열 PCB 기판에 대한 연구가 활발히 진행되고 있다. 최근까지, 금속층 회로 형성을 위해 무전해 Ni 도금에 대한 연구가 활발히 이루어져 왔다. 하지만 주로 화학적, 전기화학적 관점에서 많은 연구자들에 의해 조사 연구되어 왔다. 본 실험에서는 anodized Al 절연층 위의 회로전극 부분으로 스크린 방법으로 Ag paste를 패턴 인쇄한 뒤, 무전해도금 방식으로 저렴한 Ni 전면 회로전극을 형성하여 전기전도도를 높이고, 저항을 낮출 수 있는 회로로서 기판의 손상을 최소화하고 선택적으로 Ag 패턴에만 Ni 전극회로를 형성시키는 것을 목표로 연구하였다. Ni-B 무전해 도금시 도금조의 온도는 $65^{\circ}C$, 무전해 도금액의 pH는 ~7 (중성)로 유지하였다. Al2O3 기판을 이용한 Ag Paste 패턴 위에 증착된 Ni-B 박막의 특성을 분석하기 위해 X-ray diffraction (XRD), AFM (Atomic Force Microscopy), SEM (Scanning Electron Microscope), XPS (X-ray Photoelectron Spectroscopy)을 이용하여 Ni-B 박막의 특성을 분석하였다.

  • PDF

Preparation of Ag/Ni-coated Cu Flakes for High-temperature Conductive Paste and Ag Dewetting Behavior (고온용 전도성 페이스트를 위한 Ag/Ni 코팅 Cu 플레이크의 제조 및 Ag dewetting 거동 분석)

  • Kim, Ji-Hwan;Lee, Jong-Hyeon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.151-153
    • /
    • 2015
  • 무전해도금법을 이용하여 Ag/Ni 코팅 Cu 플레이크를 제조한 후 Ni 코팅층의 P 함량에 따른 Ag dewtting 거동에 대한 연구를 수행하였다. Ni 코팅층 내 P 함량이 낮을수록 Ni 코팅층의 결정성 및 결정화 속도가 높아지는 것을 알 수 있었으며, 이는 Ni 코팅층 위에 형성된 Ag 코팅층의 dewetting 거동에 영향을 주는 것으로 분석되었다. 또한 격자 불일치도가 높을수록 잘 발생하는 dewetting 현상은 P 함량이 높아 결정성이 떨어지는 Ni 코팅층에서 더욱 빨리 일어남을 알 수 있었다.

  • PDF

Thermal Behaviors of Ag Conductive Thick Film with Firing Temperature for Plasma Display Panel (PDP용 Ag 전도성 후막의 열적거동)

  • Hwang, Seong-Jin;Lee, Sang-Wook;Kim, Hyung-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.278-278
    • /
    • 2007
  • Ag conductive thick film has been used in bus and address electrodes of PDP (Plasma display panel). In PDP fabrication, the firing temperature of electrode is normally $550{\sim}580^{\circ}C$. For the application of PDP industry, we investigated an Ag conductive thick film with firing temperature. Low melting glass frit was used in the conductive thick film. The thermal properties of Ag and frit were determined by a hot stage microscopy. Based on the our results, we suggest that the Ag conductive thick film should be considered of the firing temperature which is correlated to the shrinkage, conductivity, and shape of thick film.

  • PDF

Development of Miniaturized Textile Electrode for Measuring Heart Electric Activity (심장 전기활동 계측을 위한 소형 섬유전극 개발 및 특성 고찰)

  • Lee, Young-Jae;Lee, Jeong-Whan;Yang, Heui-Kyung;Lee, Joo-Hyeon;Kang, Da-Hye;Cho, Hyun-Seung;Ahn, Ihn-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1186-1193
    • /
    • 2009
  • Wearable ECG monitoring is regarded as one of the most essential part in the ubiquitous healthcare environment and subsequently day-life monitoring of a heart condition has been pursued especially for the elder people. However, there are many problems to accomplish this task such as; i) implementation of long-term monitoring device, ii) development of non-irritating electrode on skin and iii) stable signal acquisition. With these aims, we have focused on implementing a non-irritating electrode with an endurable monitoring device for day-life. To accomplish our tasks, we basically developed four different types of textile electrodes that are adapted by both shape and the composed material; flat or convex shape and Ag-conductive paste material or not. It turns out to be that a convex shape and Ag-paste textile electrode has the best performance in terms of both signal-to-noise ratio (SNR) and Impedance/Phase characteristics. Furthermore, ECG amplifier (35 ${\times}$ 35 mm) has developed to resolve the ECG signal and transfer the signal to desktop computing device or portable one by RF serial communication.

Amperometric Determination of Urea Using Enzyme-Modified Carbon Paste Electrode

  • Yang, Jae-Kyeong;Ha, Kwang-Soo;Baek, Hyun-Sook;Lee, Shim-Sung;Seo, Moo-Lyong
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1499-1502
    • /
    • 2004
  • An amperometric biosensor based on carbon paste electrodes (CPEs) for the determination of urea was constructed by enzyme (urease/GL-DH)-modified method. Urea was hydrolyzed to ${NH_4}^+$ by catalyzing urease onto the enzyme-modified electrode surface in sample solution. In the presence of ${\alpha}$-ketoglutarate and reduced nicotinamide adenine dinucleotide(NADH), a liberated ${NH_4}^+$ produce to L-glutamate and $NAD^+$ by Lglutamate dehydrogenase (GL-DH). After the chemical reaction was proceeded, the electrochemical reaction was occurred that an excess of the NADH was oxidized to $NAD^+$. The oxidation current of NADH was monitored at +1.10 volt vs. Ag/AgCl. An optimum conditions of biosensor were investigated: The optimum pH range for catalyzed hydrolysis reaction of urea was pH 7.0-7.4. The linear response range and detection limit were $2.0\;{\times}\;10^{-5}{\sim}2.0\;{\times}\;10^{-4}M\;and\;5.0\;{\times}\;10^{-6}M$, respectively. Another physiological species did not interfere, except L-ascorbic acid.

무전해 구리도금 박막의 특성분석

  • Jo, Yang-Rae;Yun, Jae-Sik;Samuel, Tweneboah-Koduah;Lee, Yeon-Seung;Kim, Hyeong-Cheol;Na, Sa-Gyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.281-281
    • /
    • 2013
  • 본 연구에서는 고출력 금속 인쇄회로기판(Metal PCB) 개발을 위해 절연층으로 양극산화막을 형성하고 이 절연층 위에 Screen Printing 법을 이용하여 Ag paste를 패턴 인쇄한 알루미늄 기판을 사용하였다. 이 기판 위에 무전해 방식으로 구리 박막을 성장시켜, 무전해 도금 조건이 구리 박막 성장에 미치는 영향에 대해 연구하였다. 무전해 도금 시, pH 농도와 plating 온도를 변화시켜 이 변화에 따른 무전해 구리도금 박막의 물리적/전기적 특성을 비교 분석하여 무전해 도금에 의해 형성된 구리 박막과 기판과의 상관 관계도 비교 검토하였다. XRD (X-ray Diffraction), 광학현미경, FE-SEM (Field Emission Scanning Electron Microscope)등을 이용하여 성장된 구리 박막 및 기판의 결정성, 표면 및 단면 형상 등을 측정하였고, XPS (X-ray Photoelectron Spectroscopy)를 이용하여 무전해 도금에 의한 Cu의 화학구조 및 불순물 상태를 조사하였다.

  • PDF

Contact Resistance and Electrode Degradation on Semiconducting PTC $BaTiO_3$ Ceramics (반도성 PTC $BaTiO_3$ 세라믹에서 전극의 접촉 저항 및 퇴화)

  • 박철우;조경호;이희영;이재열
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.11
    • /
    • pp.1231-1236
    • /
    • 1996
  • The electrode resistance of semiconducting PTC BaTiO3 ceramic material was studied in some detail. Comme-rical In-Ag paste In-Ga alloy and electroless plated Ni as well as evaporated Al were chosen as electrode. The contact resistance of electroded samples were measured by both dc resistivity and ac impedance analysis. The aging effect on contact resistance under cyclic loading from -1$0^{\circ}C$ to 85$^{\circ}C$ was also monitored for the prolonged period of time. In case of Al electroded samples the heat treatment and protective coating had effects on the stability against contact resistance degradation. It was also found that the samples with commercial In-Ag paste and electroless plated Ni electrode had good properties of contact resistance against aging.

  • PDF

Fabrication of ITO-less Sustain Electrodes for High Resolution Plasma Display Panel by X-Ray Lithographic Process

  • Ryu, Seung-Min;Yang, Dong-Yol;So, Jae-Yong;Park, Lee-Soon;Cheong, Hee-Woon;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.370-373
    • /
    • 2009
  • X-ray lithography was employed to fabricate ITO-less high resolution sustain electrodes for plasma display panel (PDP). A polyimide film based X-ray mask and Xray sensitive Ag electrode paste were fabricated to check their effect on the patterning of Ag electrodes with less than 30 ${\mu}m$ in width. The X-ray lithographic method was found to be useful for the high resolution sustain electrode patterns due to the high penetration power and low scattering property of X-ray source.

  • PDF

Electrical properties of thick film dissolved oxygen sensors (후막형 용존 산소 센서의 전기적 특성)

  • Lee, Kyung-Jun;Jung, Kyung-Jin;Lee, Sung-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.92-95
    • /
    • 2003
  • The dissolved oxygen sensors with thick film type were fabricated for low cost products and the electrical properties were investigated in the different operating temperatures. Pt paste was used for working electrode and Ag/AgCl paste for reference electrode. The fabricated devices have fast response of current changes according to dissolved oxygen concentrations in the applied voltage of $0.6{\sim}0.8V$. This is expected to apply a chip and/or disposal dissolved oxygen sensors.

  • PDF