• Title/Summary/Keyword: Ag(Ⅰ) ion

Search Result 410, Processing Time 0.023 seconds

A New Cone Shaped Asymmetrically Substituted Calix[4]arene as an ExcellentIonophore in Construction of Ag(I) ion-Selective Membrane Electrode

  • Ganjali, Mohammad Reza;Babaei, Leila Hajiagha;Taghvaei-Ganjali, Saeed;Modjallal, Atoosa;Sahmsipur, Mojtaba;Hosseini, Morteza;Javanbakht, Mehran
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.2
    • /
    • pp.177-181
    • /
    • 2004
  • A PVC membrane electrode for silver ion based on a new cone shaped calix[4]arene (CASCA) as membrane carrier was prepared. The electrode exhibits a Nernstian response for $Ag^+$ over a wide concentration range ($1.0{\times}10^{-1}-8.0{\times}10^{-6}$M) with a slope of 58.2 {\pm}$ 0.5 mV per decade. The limit of detection of the sensor is $5.0{\times}10^{-6}$M. The sensor has a very fast response time (~5 s) in the concentration range of ${\leq}=1.0{\times}10^{-3}$ M, and a useful working pH range of 4.0-9.5. The proposed sensor displays excellent discriminating ability toward $Ag^+$ ion with respect to common alkali, alkaline earth, transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of $Ag^+$ with EDTA and in direct determination of silver ion in wastewater of silver electroplating.

A Study on the Removal of Silver in Copper Electrolyte (황산동전해액(黃酸銅電解液) 중 은(銀(Ag)) 제거(除去)를 위한 연구(硏究))

  • So, Sun-Seob;Ahn, Jae-Woo
    • Resources Recycling
    • /
    • v.17 no.5
    • /
    • pp.60-65
    • /
    • 2008
  • A study on the removal of silver(Ag) in copper electrolyte was carried out to produce high purity copper by using various method such as ion exchange resin, activated carbon adsorption, copper cementation with powder and wire, CuS precipitation. Parameters, such as reaction time, reaction temperature, addition amount etc. were investigated to determine the effective condition of silver removal. CuS precipitation and ion exchange using Lewatit TP214 was found to be effective. Especially, silver content in copper electrolyte was reduced from 10 ppm to less than 0.1 ppm by ion exchange with Lewatit TP214.

Electrochemical Determination of Ag(I) Ion at Chemically Modified Carbon-Paste Electrode Containing 1,5,9,13-Tetrathiacyclohexadecane (1,5,9,13-Tetrathiacyclohexadecane 수식전극을 사용한 Ag(I)의 전기화학적 정량)

  • Ha, Kwang Soo;Jang, Mi-Kyeong;Seo, Moo Lyong
    • Analytical Science and Technology
    • /
    • v.10 no.3
    • /
    • pp.187-195
    • /
    • 1997
  • Chemically modified electrodes(CMEs) for Ag(I) were constructed by incoporating 1,5,9,13-tetrathiacyclohexadecane([16]-ane-$S_4$) with a conventional carbon-paste mixture composed of graphite powder and nujol oil. Ag(I) ion was chemically deposited onto the surface of the modified electrode with [16]-ane-$S_4$ by immersion of the electrode in the acetate buffer solution(pH=4.5) containing $5.0{\times}10^{-4}M$ Ag(I) ion. And then the electrode deposited with Ag(I) was reduced at -0.3V vs. S.C.E. Well-defined stripping voltammetric peaks could be obtained by scanning the potential to the positive direction. The CME surface was regenerated with exposure to 0.1M $HNO_3$ solution and was reused for the determination of Ag(I) ion. When deposition/measurement/regeneration cycles were 10 times, the response could be reproduced with relative standard deviation of 6.08%. In case of differential pulse stripping voltammetry, the calibration curve for Ag(I) was linear over the range of $5.0{\times}10^{-7}{\sim}1.5{\times}10^{-6}M$. And the detection limit was $2.0{\times}10^{-7}M$. Various ions such as Cd(II), Ni(II), Pb(II), Zn(II), Mn(II), Mg(II), EDTA, and oxalate(II) did not influence the determination of Ag(I) ion, except Cu(II) ion.

  • PDF

A Study on the Adsorption Characteristics of Nitrogen and Oxygen on Ion Exchanged Zeolite Adsorbents (이온교환된 제올라이트 흡착제의 질소 및 산소 흡착 특성 연구)

  • Jeong, Heon-Do;Kim, Dong-Sik;Kim, Kweon-Ill
    • Applied Chemistry for Engineering
    • /
    • v.16 no.1
    • /
    • pp.123-130
    • /
    • 2005
  • Zeolite X adsorbents with large surface area were prepared for using oxygen PSA adsorbent. Selective adsorption performance of nitrogen on the synthesized zeolite X adsorbent was improved by the cation exchange of adsorbent. The zeolite X which had over $650m^2/g$ surface area was synthesized at the conditions of $SiO_2\;:\;Na_2O\;:\;H_2O\;:\;Al_2O_3$ = 2.5 : 3.5 : 150 : 1 mole ratio, $98^{\circ}C$ temperature and 18 h synthesized time in 50 L reactor. The metal ions Li, Ag, Ca, Br, Sr, etc. were investigated for ion exchange with zeolite X. Ag ion was showed the highest ion exchange rate among these metal ions and all metal ions were exchanged with Na ion at equivalent rate. Compared with the NaX adsorbent, the ion exchanged zeolite X adsorbent remarkably improved its adsorption performance of nitrogen at the conditions of $10{\sim}40^{\circ}C$ temperature and 0~9 atm pressure. At an equilibrium pressure under 0.5 atm, adsorption performance of nitrogen on the ion exchanged zeolite adsorbent increased in the order of Ag > Li > Ca > Sr> Ba > K, whereas at an equilibrium pressure over 1 atm showed in the order of Li > Ag > Ca > Sr > Ba > K. Nitrogen/oxygen separation factor of Li ion exchanged zeolite X adsorbent was 13.023 at the partial pressure of nitrogen/oxygen gas mixture similar to air and $20^{\circ}C$ adsorption temperature.

Ag(Ⅰ) Ion Selective Macrocyclic Ligands: The Complexation and Liquid Membrane Transport Phenomena of Benzylated Nitrogen-Oxygen Donor Macrocyclic Ligands (Ag(Ⅰ) 이온 선택성을 갖는 거대고리 리간드: 벤질 치환기를 갖는 질소-산소 주개 거대고리 리간드의 착물 형성과 액체막 이동 현상)

  • Kim, Jeong;Ahn, Tae Ho;Lee, Myoung Ro;Cho, Moon Hwan;Kim, Si Joong
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.2
    • /
    • pp.167-171
    • /
    • 1999
  • An investigation of the interaction of Co(II), Ni(II), Cu(II), Zn(II), Cd(II), Pb(II) and Ag(I) with two N,N'-dibenzylated nitrogen-oxygen mixed donor macrocyclic ligands, has been carried out. Tle log K values for the respective complexes in 95% methanol have been determined potentiometrically. Both ligands have formed stable complex with only Cu(II) and Ag(I) ion. Transport measurements in a bulk liquid membrane system exhibited a very high selectivity of Ag(I) ion over the other metal ions used.

  • PDF

A New PVC-Membrane Electrode Based on a Thia-Substituted Macrocyclic Diamide for Selective Potentiometric Determination of Silver Ion

  • Shamsipur, Mojtaba;Kazemi, Sayed Yahya;Niknam, Khodabaksh;Sharghi, Hashem
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.1
    • /
    • pp.53-58
    • /
    • 2002
  • A new PVC-membrane electrode for $Ag^+$ ion based on a thia-substituted macrocyclic diamide has been prepared. The electrode exhibited a Nernstian response for $Ag^+$ over a wide concentration range $(1.7{\times}10^{-6}-1.0{\times}10^{-1}M)$. It has a response time <15 s and can be used for at least 3 months without divergence. The proposed membrane sensor revealed good selectivities for $Ag^+$ over a variety of metal ions and can be used in a pH range 3.0-7.5. It has been used successfully for direct determination of $Ag^+$ in different real samples and, as an indicator electrode, in the titration of silver ion.

The Discussion of Glass Waveguide formed by ton-exchange (이온교환 방법에 의한 유리도파로 특성 고찰)

  • 박정일;김봉재;박태성;정흥배
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1994.05a
    • /
    • pp.130-132
    • /
    • 1994
  • We fabricated Ag ion exchange glass waveguide. Generally, ion-exchange glass waveguide. are suitable for passive integrated optical components such as directional and star couplers. Its advantages include low loss, ease of fabrication, and low material cost. So, we faricated Ag ion-exchange glass waveguides in AgNO$_3$ melt solution from 2 mole %. And we used Sodalime glass as a substrate in the fabrication process. As the results, we observed multivalent ion-exchange in a typical sodalime glass. Diffusion coefficient and depth are predicted by actual experimental data of Stewart. The exchange rate in silver-ion-exchanged waveguides are compared to the exchange time of waveguide fabrication.

  • PDF

Preparation of Ag Powder from AgNO3 by Wet Chemical Reduction Method1. The Establishment of Optimum Reaction System for the Preparation of Spherical Ag Powder (습식 화학적 환원법에 의한 AgNO3로부터 Ag 분말의 제조 1. 균일한 구형 Ag 분말의 제조를 위한 최적 반응계 확립)

  • Yuna, Ki-Seok;Park, Young-Chul;Yang, Beom-Seok;MIn, Hyun-Hong;Won, Chang-Whan
    • Journal of Powder Materials
    • /
    • v.12 no.1
    • /
    • pp.56-63
    • /
    • 2005
  • Ag powder was prepared from $AgNO_3$ by wet chemical reduction method using various reduction agent system involving $AgNO_3$, $AgNO_2$(AgCl) and Ag complex ion aqueous solution. The pure Ag powder could be prepared regardless of reaction system but the particle shape and distribution were affected very much according to the kind of reduction agents and reaction systems. The optimum reaction system for the preparation of the silver powder having the uniform particle shape and size distribution was Ag complex ion aqueous solution-reduction agent system and in particular, $H_2O_2$ and $C_6H_8O_6$as a reduction agent leaded the more uniform particle shape and size distribution.

Characterization of Planar Optical Waveguides by Ag$^{+}$ -Na$^{+}$ Ion Exchange in BK7 Glass (Ag$^{+}$ -Na$^{+}$이온교환법을 이용한 BK7 유리 평판형 광도파로의 특성)

  • 전금수;반재경
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.1
    • /
    • pp.84-93
    • /
    • 1998
  • Planar graded index optical waveguides have been formed by Ag$^{+}$ ion exchange in the BK7 optical glass. The experimental results of diffusion and modal characteristics of Ag$^{+}$-Na$^{+}$ exchanged BK7 glass waveguides are presented. Measurements of the mode indices have been measured. We found the relations between the process and device parameters such as the diffusion depth and the square root of the diffusion time, diffusion coefficient and diffusion temperature, and diffusion ion concentration and surface index change. A theoretical gaussian function refractive index profile matched best with the measured data for all the guided modes. The empirical relations between the process and the device parameters are derived and subsequently used to formulate a systematic procedure for fabricating singlemode and multimode waveguides.uides.

  • PDF