• Title/Summary/Keyword: Aerosol size distribution

검색결과 204건 처리시간 0.022초

Hy-SMPS의 개발 및 성능평가 (Development and Evaluation of Hy-SMPS)

  • 이홍규;은희람;이건호;안강호
    • 한국입자에어로졸학회지
    • /
    • 제11권2호
    • /
    • pp.57-61
    • /
    • 2015
  • Atmospheric nano-particles along the altitude is one of the main factors causing severe weather phenomena. It is a challenge to find the precise particle size distribution. One useful instrument includes a scanning mobility particle sizer (SMPS). This measures the size distribution of submicron aerosols. The SMPS consists of a condensation particle counter (CPC), differential mobility analyzer (DMA), high voltage power supplier (HVPS), and neutralizer. Due to the many components, it is difficult to install a commercial SMPS into a tethered balloon package system (Eun, 2011). In this study, we customized a SMPS for the tethered balloon package system called Hy-SMPS. It is portable, compact in structure, and evaluated by TSI SMPS using mono and poly-dispersed particles.

에어로졸 데포지션 공정으로 제작된 BaTiO3 필름 성장에 출발 원료가 미치는 영향 (Effect of Starting Powder on the Growth of BaTiO3 Film Prepared by Aerosol Deposition Process)

  • 조명연;김익수;이동원;구상모;오종민
    • 한국전기전자재료학회논문지
    • /
    • 제33권3호
    • /
    • pp.208-213
    • /
    • 2020
  • Four types of BaTiO3 powders are prepared and successfully deposited on glass and Pt/Si substrates using the aerosol deposition process. Particles with sizes of 0.45 ㎛ and 0.3 ㎛ are selected as the starting powder, while those powders are treated using a different milling method. The jet-milled and ball-milled powders not only showed a smaller particle-size distribution, but compared with the non-milled powder, it also had a higher deposition rate using the uniformly generated aerosol. Although the films deposited using particles with size 0.45 ㎛ exhibited some craters on the surface, significantly flat film surfaces were obtained. However, particles with size 0.3 ㎛ create a slightly rough film surface, but the dielectric constant was greater than in the case involving particles with size 0.45 ㎛. Consequently, a suitably large particle size significantly influences the deposition rate and improvement in the surface roughness, and a uniform particle size distribution appears to contribute to an improved dielectric constant. Therefore, it is believed that the dielectric properties along with the growth characteristics can be enhanced by limiting particle size and shape.

초음파에 의한 액체 미립화 특성에 관한 연구 (A study on Characteristics of the Liquid Atomization by Ultrasonic)

  • 주은선;나우정;최우창
    • 한국자동차공학회논문집
    • /
    • 제7권5호
    • /
    • pp.31-39
    • /
    • 1999
  • A good atomization in uniform size brings the elevation of thermal efficiency in spray combustion, the beautiful painting on surfaces, and the economical sprinkling of chemicals. Ultrasonic atomization has been expected as a good uniform atomization mechanism due to its uniform size distribution. Influx, load, and physical properties of liquids are the effecting factors to atomize liquids. In this study, distilled water and city water are selected as reference liquids and gasoline, kerosene, and petroleum as fuel liquids. Characteristics and affinity to get the maximum effect for the ultrasonic atomization are observed by using the two ultrasonic transducers with 28kHz and 2MHz. Results show that the size distributions of liquid spray dorplet by the direct vibration method prevail over those by the aerosol method in uniform droplet size and as a whole, sizes of spray liquid droplets are increased slightly according to increasing influx in the direct vibration method and quantities of spray droplets in the aerosol method decreasing according to increasing liquid load h.

  • PDF

황사의 크기 및 침착량에 대한 수치 모의 (A Numerical Study on the Size and Depositions of Yellow Sand Events)

  • 정관영;박순웅
    • 한국대기환경학회지
    • /
    • 제14권3호
    • /
    • pp.191-208
    • /
    • 1998
  • Estimations of dry and wet depositions in Korea and the size distributions of yellow sand above Korea have been carried out using the Eulerian aerosol model with the simulated meteorological data from the SNU mesoscale meteorological model. The estimated particle size distribution in Korea shows a bimodal distribution with peak values at 0.6 pm and 7 pm and a minimum at 2 pm in the lower layer However, as higher up, the bimodal distribution becomes an unimodal distribution with a peak value at 4∼5mm. Among the total amount of yellow sand deflated in the source regions , the dry and wet deposition fluxes were about 92%, and about 1.3∼0.5%, repectively, and the rest(5∼6%) is suspended in the air, Most of dust lifted in the air during the clear weather is deposited in the vicinity of the source regions by dry deposition and the rest undergoes the long -range transport with a gradual removal by the wet deposition processes. Over Korean peninsula, the total amount of yellow sand suspended in the air was about 6∼8% of the emissions in the source region and the dry and wet deposition fluxes were about 0.005∼0.7% and 0.003∼0.051% of the total emitted amount, repectively. It is estimated that 2.7∼8.9 mesa-tons of yellow sand is transported annually over the Korean peninsula with the annual mean dry deposition of 2.1∼490 kilo-tons and the annual mean wet deposition of 1.5∼65 kilo-tons.

  • PDF

도시대기중 호흡성 먼지의 이온성분 거동 특성 (Characteristics of Ion Compositions of the Respirable Particles in Seoul)

  • 신은상;강병욱
    • 환경위생공학
    • /
    • 제9권2호
    • /
    • pp.24-31
    • /
    • 1994
  • Aerosol size distribution were determined in Seoul by Anderson sampler from October 1989 to September 1991 for the major ionic species(SO$_{4}$$^{2-}$, NO$_{3}$$^{-}$, Cl$^{-}$, Na$^{+}$, Na$^{+}$, K$^{+}$, Ca$^{2+}$ and Mg$^{2+}$) and TSP( Total Suspended Particles ). The seasonal variations in concentrations and size distribution have been investigated. The size distributions of TSP and each of ionic species were bimodal throughout the year. The size distribution of these ions were divided as follows; (1) fine- mode dominant for SO$_{4}$$^{2-}$ and N%'. (2) coarse- mode dominant for NO$_{3}$$^{-}$, Cl$^{-}$, Ca$^{2+}$ and Mg$^{2+}$. (3) both- mode dominant for TSP.

  • PDF

황사 시 제주지역 에어로졸의 수농도 특성 (The Characteristics of the Aerosol Number Concentration in Jeju Area During Asian Dust Events)

  • 강창희;허철구
    • 한국환경과학회지
    • /
    • 제22권3호
    • /
    • pp.347-358
    • /
    • 2013
  • The aerosol number concentration have measured with an aerodynamic particle sizer spectrometer(APS) at Gosan in Jeju Island, which is known as background area in Korea, from March 2010 to February 2011. The obtained results of asian dust events and non-asian dust period have been compared. The results show that the entire averaged aerosol number concentration from APS measurement during asian dust events and non-asian dust period are about 341 particles/$cm^3$ and 240 particles/$cm^3$, respectively. During asian dust events, the number concentration in small size ranges(${\leq}0.4{\mu}m$) are similar to non-asian dust period, however, those in large size ranges(${\geq}0.7{\mu}m$) are very higher than non-asian dust period. The contributions of the size resolved number concentration(23 channel in $0.25{\sim}10.0{\mu}m$) to total number concentration in that range are dramatically decreased with increased particle size. The contributions of smaller size ranges(${\leq}0.4{\mu}m$) during asian dust events are very low compared with non-asian dust period, on the other hand, those of larger size ranges(${\geq}0.4{\mu}m$) are higher than non-asian dust period. The number concentration in each size range are strongly correlated with the concentration in adjacent size range. And the total aerosol number concentration are depended on the number concentration in range of smaller than $0.58{\mu}m$ during non-asian dust period and asian dust events. On the other hand, $PM_{10}$ mass concentration has mainly affected with the number concentration in range of smaller than $1.0{\mu}m$ during non-asian dust period, however, during asian dust events, the mass concentration has mainly affected with the number concentration in range of $0.65{\sim}3.0{\mu}m$.

무인항공기를 이용한 대기갈색연무의 기후효과 연구 (Using Unmanned Aerial Vehicles (UAVs) to Study on the Climate Impacts of the Atmospheric Brown Clouds)

  • 김상우;윤순창
    • 대기
    • /
    • 제20권4호
    • /
    • pp.519-530
    • /
    • 2010
  • In this paper we review current research on Atmospheric Brown Clouds (ABCs) with lightweight Unmanned Aerial Vehicles (UAVs) and miniaturized instruments. The UAV technology for in-situ measurements, including aerosol concentration, aerosol size distribution, aerosol absorption, cloud drop size distribution, solar radiation fluxes (visible and broadband), and spectral radiative fluxes, is a leading-edge technology for cost-effective atmospheric sounding, which can fill the gap between the ground measurement and satellite observation. The first experimental observation with UAVs in Korea, Cheju ABC Plume Monsoon Experiment (CAPMEX), conducted during summer 2008 revealed that the Beijing plumes exerted a strong positive influence on the net warming and fossil-fuel-dominated black-carbon plumes were approximately 100% more efficient warming agents than biomass-burning-dominated plumes. Long-term sustainable routine UAV measurements will eventually provide truly three-dimensional data of ABCs, which is necessary for the better understanding of their climate impacts and for the improvement of numerical models for air pollution, weather forecast and climate change.

광학적 입자계수기를 이용한 2004년 황사기간 인천지역 에어로졸 특성 (Characteristics of Incheon Aerosol during Asian Dust Period in 2004 using Optical Particle Counter (OPC))

  • 정창훈;조용성;이종태
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.565-575
    • /
    • 2005
  • The characteristics for the aerosol number distribution was studied during spring, 2004 in Incheon. Optical Particle Counter (OPC, HIAC/ROYCO 5230) was used in order to measure the number concentration of aerosol in the range of $0.3\~25{\mu}m.$. The obtained results were compared with $PM_{2.5}\;and\;PM_{10}$ data during Asian dust events. The results show that the size resolved aerosol number concentration from OPC measurement has a similar tendency with $PM_{10}\;and\;PM_{2.5}$ mass concentration. During Asian dust periods, the number concentrations in large particle $(CH5\~CH8)$ increase more than small particles which diameter is less than $2.23{\mu}m(CH5)$ and the same results were shown when $PM_{10}$ was compared with $PM_{2.5}$ data compared with non-dust days, Consequently, this study shows that size resolved aerosol number concentration from OPC measurement can be used as a useful tool in comparison of mass concentration data.

Performance assessment of HEPA filter to reduce internal dose against radioactive aerosol in nuclear decommissioning

  • Hee Kwon Ku;Min-Ho Lee;Hyunjin Boo;Geun-Dong Song;Deokhee Lee;Kaphyun Yoo;Byung Gi Park
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1830-1837
    • /
    • 2023
  • The thermal cutting of contaminated or activated metals during decommissioning nuclear power plants inevitably results in the release of radioactive aerosol. Since radioactive aerosols are pernicious particles that contribute to the internal dose of workers, air conditioning units with a HEPA filter are used to remove radioactive aerosols. However, a HEPA filter cannot be used permanently. This study evaluates the efficiency and lifetime of filters in actual metal cutting condition using a plasma arc cutter and a high-resolution aerosol detector. The number concentration and size distribution of aerosols from 6 nm to 10 ㎛ were measured on both the upstream and downstream sides of the filter. The total aerosol removal efficiency of HEPA filter satisfies the standard of removing at least 99.97% of 0.3 ㎛ airborne particles, even if the pressure drop increases due to dust feeding load. The pressure drop and particle size removal efficiency at 0.3 ㎛ of the HEPA filter were found to increase with repeated cutting experiments. By contrast, the efficiency of used HEPA filter reduced in removing nano-sized aerosols by up to 79.26%. Altogether, these results can be used to determine the performance guidance and replacement frequency of HEPA filters used in nuclear power plants.

스카이라디오미터 관측을 통한 서울 상공 에어러솔의 광학적 특성 분석 (Analysis of Aerosol Optical Properties in Seoul Using Skyradiometer Observation)

  • 구자호;김준;김미진;조희구
    • 대기
    • /
    • 제17권4호
    • /
    • pp.407-420
    • /
    • 2007
  • Optical characteristics of aerosols in Seoul are investigated from the measurements of sky radiance by Skyradiometer at Yonsei University from December 2005 to November 2006. Aerosol optical depth (AOD) shows a maximum in June due to weak ventilation and particle growth by aging process and hygroscopic effect. Single scattering albedo (SSA) and Angstrom Exponent (AE) show the lowest value in spring due to the Asian dust. It is clear that coarse mode is dominant in spring and fine mode is dominant in summer from the volume size distribution measured in this study. The explanations on the changes of aerosol loadings are provided through the correlation between AOD and AE, while the pattern of wavelength dependency related to particle size is shown through the correlation between SSA and AE. Backward trajectory analysis by HYSPLIT provides information about origin of aerosol, which allows us to classify the case according to the source region and the path distance. Although the direction of backward trajectory traces back mostly to west, coarse mode particle is dominant in the case of long pathway and fine mode particle is dominant in the case of short pathway. This discrepancy is caused by the regional difference of emitted particles.