• Title/Summary/Keyword: Aerosol Particle

Search Result 667, Processing Time 0.022 seconds

The performance of Bio-aerosol Detection System (BDS) with 405 nm laser diode (405 nm 광원을 이용한 생물입자탐지기의 에어로졸 분석성능)

  • Jeong, Young-Su;Chong, Eugene;Lee, Jong-Min;Choi, Kibong
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.25-31
    • /
    • 2017
  • This paper offer the characteristics for the detection and classification of biological and non-biological aerosol particles in the air by using laser-induced-fluorescence (LIF) based Bio-aerosol Detection System (BDS). The BDS is mainly consist of an optical chamber, in-outlet nozzle system, 405 nm diode laser, an avalanche photo detector (APD) for scattering signal and photomultiplier tubes (PMT) for fluorescence signals in two different wavelength range ; F1, 510-600 nm and F2, 435-470 nm. The detection characteristics, especially ratio of fluorescence signal intensity were examined using well-known components : polystylene latex (PSL), fluorescence PSL, $2{\mu}m$ of SiO2 micro sphere, dried yeast, NADH, ovalbumin, fungicide powder and standard dust. The results indicated that the 405 nm diode laser-based LIF instrument can be a useful bio-aerosol detection system for unexpected biological threaten alter in real-time to apply for dual-use technology in military and civilian fields.

Vertical Aerosol Distribution and Flux Measurement in the Planetary Boundary Layer Using Drone (드론을 이용한 안면도 상공 대기경계층내의 미세먼지 연직분포 및 Flux 측정)

  • Kim, Heesang;Park, Yonghe;Kim, Wooyoung;Eun, Heeram;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.14 no.2
    • /
    • pp.35-40
    • /
    • 2018
  • Vertical particle size distribution, total particle concentration, wind velocity, temperature and humidity measurement was performed with a drone. The drone was equipped with a wind sensor, house-made optical particle count(Hy-OPC), condensation particle counter(Hy-CPC), GPS, Temperature, Relative Humidity, Pressure and communication system. Base on the wind velocity and the particle size vertical distribution measurement with drone, the particle mass flux was calculated. The vertical particle distribution showed that the particle number concentration was very strongly correlated with the relative humidity.

Characteristics of Aerosol Particle Concentration by the Versatile Aerosol Concentration Enrichment System (VACES) (VACES을 이용한 대기 중 입자상물질의 농축기술 및 특성 연구)

  • Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.21 no.11
    • /
    • pp.1339-1348
    • /
    • 2012
  • The versatile aerosol concentration enrichment system (VACES) have proven useful for providing elevated levels of atmospheric aerosol to human and animal exposures. In this study, we describe a VACES and tests conducted to both optimize the enhancement factor (EF) and characterize how it depends on experiment conditions. Particle number concentrations were measured from upstream and downstream of the system by scanning mobility particle sizer (SMPS) with a long differential mobility analyzer (DMA) in combination with a condensation particle counter (CPC). SMPS was used for to determine VACES particle EF. Particle EF tends to increase for higher the saturator temperature ($T_{Sat}$) and lower the condenser temperature ($T_{Con}$). $T_{Con}$ higher than $0^{\circ}C$ and $T_{Sat}$ lower than $50^{\circ}C$ was the best to obtain the most increase in particle concentration. Correlation analysis of EF with factor variables of $T_{Sat}$ and $T_{Con}$ resulted in correlation 0.662 and 0.416, respectively. With all five predictor variables included in a multiple regression model, the EF had a liner correlation with $R^2=0.643$.

Particle-size-dependent aging time scale of atmospheric black carbon (입자 크기의 함수로 나타낸 대기 중 블랙카본의 변성시간척도)

  • Park, Sung Hoon
    • Particle and aerosol research
    • /
    • v.5 no.2
    • /
    • pp.45-52
    • /
    • 2009
  • Black carbon, which is a by-product of combustion of fossil fuel and biomass burning, is the component that imposes the largest uncertainty on quantifying aerosol climate effect. The direct, indirect and semi-direct climate effects of black carbon depend on its state of the mixing with other water-soluble aerosol components. The process that transforms hydrophobic externally mixed black carbon particles into hygroscopic internally mixed ones is called "aging". In most climate models, simple parameterizations for the aging time scale are used instead of solving detailed dynamics equations on the aging process due to the computation cost. In this study, a new parameterization for the black carbon aging time scale due to condensation and coagulation is presented as a function of the concentration of hygroscopic atmospheric components and the black carbon particle size. It is shown that the black carbon aging time scale due to condensation of sulfuric acid vapors varies to a large extent depending on the sulfuric acid concentration and the black carbon particle size. This result indicates that the constant aging time scale values suggested in the literature cannot be directly applied to a global scale modeling. The aging time scale due to coagulation with internally mixed aerosol particles shows an even stronger dependency on particle size, which implies that the use of a particle-size-independent aging time scale may lead to a large error when the aging is dominated by coagulation.

  • PDF

Particle deposition on a semiconductor wafer larger than 100 mm with electrostatic effect (정전효과가 있는 100mm보다 큰 반도체 웨이퍼로의 입자침착)

  • Song, Gen-Soo;Yoo, Kyung-Hoon;Lee, Kun-Hyung
    • Particle and aerosol research
    • /
    • v.5 no.1
    • /
    • pp.17-27
    • /
    • 2009
  • Particle deposition on a semiconductor wafer larger than 100 mm was studied experimentally and numerically. Particularly the electrostatic effect on particle deposition velocity was investigated. The experimental apparatus consisted of a particle generation system, a particle deposition chamber and a wafer surface scanner. Experimental data of particle deposition velocity were obtained for a semiconductor wafer of 200 mm diameter with the applied voltage of 5,000 V and PSL particles of the sizes between 83 and 495 nm. The experimental data of particle deposition velocity were compared with the present numerical results and the existing experimental data for a 100 mm wafer by Ye et al. (1991) and Opiolka et al. (1994). The present numerical method took into consideration the particle transport mechanisms of convection, Brownian diffusion, gravitational settling and electrostatic attraction in an Eulerian frame of reference. Based on the comparison of the present experimental and numerical results with the existing experimental results the present experimental method for a 200 mm semiconductor wafer was found to be able to present reasonable data.

  • PDF

Vertically Distributed Aerosol Sampling and Analysis using Tethered Balloon Sampler System in Ansan (안산지역 내에서의 Tethered Balloon 탑재형 포집기를 이용한 연직 분포된 Aerosol 포집 및 분석)

  • Eun, Hee-Ram;Kim, Whan-Ki;Lee, Hong-Ku;Yoo, Dong-Hyun;Yook, Se-Jin;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.7 no.4
    • /
    • pp.139-149
    • /
    • 2011
  • It is very important to measure atmospheric particles and evaluate the characteristics of them since aerosol can influence atmospheric environment, climate, and health. Satellite, aircraft, radio sonde are usually used to measure the vertical distribution of particle properties, temperature, humidity, and pressure. Although the method of using an aircraft is favorable to collect the horizontal distribution of the particles, but unadaptable to measure the vertical distribution of the particles. However, all-in-one balloon particle sampler system can collect particles depending on each altitude controling the balloon by winch. In this research, we performed the air sampling on the TEM grids using house made light weight impactor at the altitude of 300m and 900m. The collected particles were analyzed using TEM/EDS.

Effect of Performance of Aerosol Charge Neutralizers on the Measurement of Highly Charged Particles Using a SMPS (에어로졸 중화기의 성능이 고하전 입자의 크기분포 측정에 미치는 영향)

  • Ji, Jun-Ho;Bae, Swi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1498-1507
    • /
    • 2003
  • A SMPS(scanning mobility particle sizer) system measures the number size distribution of particles using electrical mobility detection technique. An aerosol charge neutralizer, which is a component of the SMPS, is a bipolar charger using a radioactive source to apply an equilibrium charge distribution to aerosols of unknown charge distribution. However, the performance of aerosol charge neutralizers is not well known, especially for highly charged particles. In this study, the effect of the particle charging characteristics of two aerosol charge neutralizers on the measurement using a SMPS system was experimentally investigated for highly charged polydisperse particles. One has radioactive source of $^{85}$ Kr (beta source, 2 mCi) and the other has $^{210}$ Po (alpha source, 0.5 mCi). The air flow rate passing through each aerosol charge neutralizer was changed from 0.3 to 3.0 L/min. The results show that the non-equilibrium character in particle charge distribution appears as the air flow rate increases although the particle number concentration is relatively low in the range of 1.5∼2x10$^{6}$ particles/㎤. The low neutralizing efficiency of the $^{85}$ Kr aerosol charge neutralizer for highly charged particles can cause to bring an artifact in the measurement using a SMPS system. However, the performance of the $^{210}$ Po aerosol charge neutralizer is insensitive to the air flow rate.

Effects of Aerosol Hygroscopicity on Fine Particle Mass Concentration and Light Extinction Coefficient at Seoul and Gosan in Korea

  • Choi, Eun-Kyung;Kim, Yong-Pyo
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.1
    • /
    • pp.55-61
    • /
    • 2010
  • The sensitivity of aerosol light extinction coefficient to the aerosol chemical composition change is estimated by (1) calculating the aerosol water content and chemical concentrations by a gas/particle equilibrium model and (2) calculating the aerosol light extinction coefficient by a Mie theory based optical model. The major chemical species are total (gas and particle phase) sulfuric acid, total nitric acid, and total ammonia which are based on the measurement data at Seoul and Gosan. At Seoul, since there were enough ammonia to neutralize both total sulfuric acid and total nitric acid, the dry ionic concentration is most sensitive to the variation of the total nitric acid level, while the total mass concentration (ionic concentration plus water content) and thus, the aerosol light extinction coefficient are primarily determined by the total sulfuric acid. At Gosan, since the concentration of ambient sulfuric acid was the highest among the inorganic species, sulfate salts determined aerosol hygroscopicity. Thus, both ionic and total mass concentration, and resultant aerosol light extinction coefficient are primarily determined by the sulfuric acid level.

Single Particle Characterization of Aerosol Particles Collected at Jeju Island, Korea, During 'ACE-Asia' Intensive Observation Period, Using Low-Z Particle Electron Probe X-ray Microanalysis (Low-Z Particle Electron Probe X-ray Microanalysis법을 이용한 2001년 ACE-Asia 집중 측정 기간 중 제주도 고산에서의 입자상 물질의 특성분석)

  • An Yong Hoon;Kim HyeKyeong;Ro Chul-Un
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.6
    • /
    • pp.811-821
    • /
    • 2004
  • Low-Z particle electron probe X-ray microanalysis (low-Z particle EPMA) was applied to characterize aerosol particles collected at Gosan in Jeju island during an IOP (intensive observation period) for an international ACE-Asia project in April, 2001. Various types of atmospheric particles such as organics, carbon-rich, aluminosilicates, silicon oxide, sodium nitrate, sodium chloride, and ammonium sulfate were observed. The reacted sea salt particles such as sodium nitrate were the most abundantly encountered, but original sea salt particles were rarely observed. Since the Low-Z particle EPMA can provide quantitative information on the chemical composition of aerosol particles, many different particle types on the basis of their chemical compositions were observed and identified. In this study, it is demonstrated that the Low-Z particle EPMA can provide detailed information on the chemical compositions for the aerosol particles collected for six consecutive days in April, 2001, at Gosan super-site.