• Title/Summary/Keyword: Aerodynamic Analysis

Search Result 1,343, Processing Time 0.031 seconds

Effect of Proton Pump Inhibitors, Mucolytics and Steroids on Voice Outcomes After Laryngomicrosurgery (후두미세수술 후 양성자펌프억제제, 점액용해제, 스테로이드가 음성에 미치는 영향)

  • Choi, Yeon Soo;Kim, Ji Won
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.33 no.1
    • /
    • pp.31-36
    • /
    • 2022
  • Background and Objectives Proton pump inhibitors (PPIs), mucolytics, and steroids were commonly recommended after phonomicrosurgery to prevent worsening of vocal fold (VF) scar formation and subglottal swelling. However, there is no consensus about whether laryngeal reflux and thick discharge are associated with the voice outcomes following phonomicrosurgery in benign VF lesions. The purpose of this study is to examine voice outcomes of use of PPIs, mucolytics,and steroids after phonomicrosurgery. Materials and Method This randomized controlled study is performed with patients undergoing laryngomicroscopic surgery for VF polyp and cyst. Participants were randomly assigned to 1) no medication, 2) PPIs, 3) PPIs+mucolytics, and 4) PPIs+mucolytics+steroids for 2 months postoperatively. Grade, roughness, breathiness, asthenia, and strain (GRBAS) scale, stroboscopic examination, aerodynamic assessment, acoustic analysis, and Voice Handicap Index-10 (VHI-10) were performed pre- and post-operatively at 2 months. Parameters were compared among four groups. Results Among 85 patients, a total of 50 patients were included. The VHI-10, perceptual and acoustic parameters improved in all groups after surgery. However, there was no significant difference in those parameters among all groups. Conclusion PPIs, mucolytics, and steroids did not significantly influence voice outcomes after phonomicrosurgery in patients with benign VF lesions.

Galloping characteristics of a 1000-kV UHV iced transmission line in the full range of wind attack angles

  • Lou, Wenjuan;Wu, Huihui;Wen, Zuopeng;Liang, Hongchao
    • Wind and Structures
    • /
    • v.34 no.2
    • /
    • pp.173-183
    • /
    • 2022
  • The galloping of iced conductors has long been a severe threat to the safety of overhead transmission lines. Compared with normal transmission lines, the ultra-high-voltage (UHV) transmission lines are more prone to galloping, and the damage caused is more severe. To control the galloping of UHV lines, it is necessary to conduct a comprehensive analysis of galloping characteristics. In this paper, a large-span 1000-kV UHV transmission line in China is taken as a practical example where an 8-bundled conductor with D-shaped icing is adopted. Galerkin method is employed for the time history calculation. For the wind attack angle range of 0°~180°, the galloping amplitudes in vertical, horizontal, and torsional directions are calculated. Furthermore, the vibration frequencies and galloping shapes are analyzed for the most severe conditions. The results show that the wind at 0°~10° attack angles can induce large torsional displacement, and this range of attack angles is also most likely to occur in reality. The galloping with largest amplitudes in all three directions occurs at the attack angle of 170° where the incoming flow is at the non-iced side, due to the strong aerodynamic instability. In addition, with wind speed increasing, galloping modes with higher frequencies appear and make the galloping shape more complex, indicating strong nonlinear behavior. Based on the galloping amplitudes of three directions, the full range of wind attack angles are divided into five galloping regions of different severity levels. The results obtained can promote the understanding of galloping and provide a reference for the anti-galloping design of UHV transmission lines.

Assessing the Health Benefits of PM2.5 Reduction Using AirQ+ and BenMAP (AirQ+와 BenMAP을 이용한 초미세먼지 개선의 건강편익 산정)

  • Sun-Yeong Gan;Hyun-Joo Bae
    • Journal of Environmental Health Sciences
    • /
    • v.49 no.1
    • /
    • pp.30-36
    • /
    • 2023
  • Background: Among various pollutants, fine particle (PM2.5, defined as particle less than 2.5 nm in aerodynamic diameter) shows the most consistent association with adverse health effects. There is scientific evidence documenting a variety of adverse health outcomes due to exposure to PM2.5. Objectives: This study aims to assess the health benefits of that would be achieved by meeting the World Health Organization's air quality guidelines for PM2.5 using AirQ+ and BenMAP. Methods: We estimated PM2.5 related health benefits in Korea from implementing the World Health Organization's air quality guidelines (annual average 5 ㎍/m3 and 10 ㎍/m3) and Korea's National Ambient Air Quality Standard (annual average 15 ㎍/m3). We used World Health Organization's AirQ+ and U.S. Environmental Protection Agency's Environmental Benefits Mapping and Analysis Program. Results: The annual number of avoided PM2.5 related premature deaths exceeding WHO guideline levels was assessed using both AirQ+ and BenMAP. We estimated that the health benefits of attaining the World Health Organization's air quality guidelines for PM2.5 (annual average 5 ㎍/m3) would suggest an annual reduction of 26,128 (95% confidence interval [CI]: 17,363~34,024) and 26,853 (95% CI: 18,527~34,944) premature deaths. Conclusions: Our study provided useful information to policy makers and confirms that the reduction of PM2.5 concentration would result in significant health benefits in Korea.

Fatigue Life Prediction for the Skin Structures of Aircraft Sensor Pod Under Acoustic Load with Mean Stress (평균 응력을 고려한 음향 하중을 받는 항공기 센서 포드 외피 구조의 내구 수명 분석)

  • Min-Hyeok Jeon;Yeon-Ju Kim;Hyun-Jun Cho;Mi-Yeon Lee;In-Gul Kim;Hansol Lee;Jae Myung Cho;Jong In Bae;Ki-Young Park
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • The skin structure of sensor pod mounted on the exterior of aircraft can be exposed to the acoustic dynamic load and static load such as aerodynamic pressure and inertial load during flight. Fatigue life prediction of structural model under acoustic load should be performed and also differential stiffness of model modified by static load should be considered. The acoustic noise test spectrum of MIL-STD-810G was applied to the structural model and the stress response power spectral density (PSD) was calculated. The frequency response analysis was performed with or without prestress induced by inplane static load, and the response spectrum was compared. Time series data was generated using the calculated PSD, and the time and frequency domain fatigue life were predicted and compared. The variation of stress response spectrum due to static load and predicted fatigue life according to the different structural model considering mean stress were examined and decreasing fatigue life was observed in the model with prestress of compressive static load.

The Phoniatric Evaluation of the Effect of the Laryngomicrosurgery for the Laryngeal Polyps and the Nodules (성대폴립및 결절의 치료 효과에 대한 음성의학적 고찰)

  • 김기령;홍원표;김광문;이경재;정태영;이명호
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1983.05a
    • /
    • pp.8.2-9
    • /
    • 1983
  • Recently, the laryngomicrosurgery has been done for the removal of benign laryngeal mass and for the improvement of voice. For the evaluation of the effect of the treatment, there must be any objective method such as aerodynamic study, vocal fold vibration study, acoustic analysis, psycho-acoustic evaluation and the neuro-muscular study. The authors evaluated the phoniatric effect of the laryngomicrosurgery for the patients of 15 laryngeal polyps and 9 laryngeal nodules, who received pre-op. and post-op. vocal function study from Jun. 1981 to Mar. 1983. The results obtained were as follows ; 1) The post-op. mean value of the maximum phonation time was increased 40 % in the unilateral polyps, 62 % in the bilateral nodules and 18 % in the unilateral nodules. 2) The post-op. mean value of the phonation quotient was decreased 25 % in comparison with pre-op. value in the case of the bilateral polyps, 26 % in the unilateral polyps, 55 % in the bilateral nodules and 12 % in the unilateral nodules. 3) The post-op. mean value of the mean air flow rate was decreased 27 % in comparison with the pre-op. value in the case of the bilateral polyps, 25 % in the unilateral polyps, 65 % in the bilateral nodules, 25 % in the unilateral nodules. 4) The glottic chink of the 10 cases of polyps among the 11 cases were disappeared, and the glottic chink of the 5 cases of nodules among 7 cases were also disappeared after surgery. 5) The pre-op. hoarseness of the 10 cases of polyps among the pre-op. hoarseness of the 11 cases of polyps were changed to clear and the 3 cases of nodules were also changed to clear.

  • PDF

The Analysis of PM10 Concentration and Emission Contribution in the Major Cities of Korea (한반도 주요 대도시의 PM10 농도 특성 및 배출량과의 상관성 분석)

  • Kang, Minsung;Kim, Yoo-Keun;Kim, Taehee;Kang, Yoon-Hee;Jeong, Ju-Hee
    • Journal of Environmental Science International
    • /
    • v.25 no.8
    • /
    • pp.1065-1076
    • /
    • 2016
  • This study analyzes the $PM_{10}$ characteristics (particulate matter with aerodynamic diameter less than $10{\mu}m$), concentration, and emissions in eight large South Korean cities (Seoul, Incheon, Daejeon, Daegu, Gwangju, Ulsan, Busan, Jeju). The annual median of $PM_{10}$ concentration showed a decline of $0.02{\sim}1.97{\mu}g/m^3$ in the regions, except for Incheon, which recorded an annual $0.02{\mu}g/m^3$ increase. The monthly distribution levels were high in spring, winter, fall, and the summer, but were lower in summer for all regions except for Ulsan. These differences are thought to be due to the dust in spring and the cleaning effect of precipitation in summer. The variation in concentrations during the day (diurnal variation) showed that $PM_{10}$ levels were very high during the rush hour and that this was most extreme in the cities (10.00 and 18.00-21.00). The total annual $PM_{10}$ emissions analysis suggested that there had been a general decrease, except for Jeju. On-road mobile (OM) sources, which contributed a large proportion of the particulates in most regions, decreased, but fugitive dust (FD) sources increased in the remaining regions, except for Daegu. The correlation analysis between $PM_{10}$ concentrations and emissions showed that FD could be used as a valid, positive predictor of $PM_{10}$ emissions in Seoul (74.5% (p<0.05)), Dajeon (47.2% (p<0.05)), and Busan (59.1% (p<0.01)). Furthermore, industrial combustion (IC) was also a significant predictor in Incheon (61.7% (p<0.01)), and on-road mobile (OC) sources were a valid predictor in Daegu (24.8% (p<0.05)).

Capsule Train Dynamic Model Development and Driving Characteristic Analysis Considering the Superconductor Electrodynamic Suspension (초전도 유도 반발식 부상특성을 고려한 캡슐트레인 동특성 해석 모델 구축 및 주행 특성 분석)

  • Lee, Jin-Ho;Lim, Jungyoul;You, Won-Hee;Lee, Kwansup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.38-45
    • /
    • 2020
  • A magnetically levitating capsule train, which runs inside the sub-vacuum tube, can reach ultra-fast speeds by dramatically reducing the aerodynamic drag and friction. The capsule train uses the superconductor electrodynamic suspension (SC-EDS) method for levitation. The SC-EDS method has advantages, such as a large levitation gap and free of gap control, which could reduce the infra-construction cost. On the other hand, disadvantages, such as the large variation of the levitation-guidance gap and small damping characteristics in levitation-guidance force, could degrade the running stability and ride comfort of the capsule train. In this study, a dynamic analytical model of a capsule train based on the SC-EDS was developed to analyze the running dynamic characteristics. First, as important factors in the capsule train dynamics, the levitation and guidance stiffness in the SC-EDS system were derived, which depend non-linearly on the velocity and gap variation. A 3D dynamic analysis model for capsule trains was developed based on the derived stiffness. Through the developed model, the effects of the different running speeds on the ride comfort were analyzed. The effects of a disturbance from infrastructure, such as the curve radius, tube sag, and connection joint difference, on the running stability of the capsule train, were also analyzed.

Computational Fluid Dynamic(CFD) Analysis-based Feasibility Study on Wind Power Generation due to Traveling Vehicles on Highway (전산유체역학해석을 통한 고속도로 주행차량 유도풍의 풍력발전 적용 가능성에 관한 연구)

  • Jeon, Je Yeon;Han, Kwan Mun;Song, Jong Sub;Park, Seunghee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.739-748
    • /
    • 2013
  • In this study, analytical works for the induced winds due to traveling vehicles on highway have been conducted by Computation Fluid Dynamics (CFD). The traveling condition was considered in two cases: (a) single direction and (b) bi-direction. The analysis was focused on the effects of the induced winds on the upper part of a median strip while the aerodynamic characteristics of the vehicles were directly analyzed in the previous studies. From the analysis results, it has been found that the maximum magnitude of the induced winds was 2.2 m/s when the vehicles travel with the speed of 50 km/h. Additionally, 4.0 m/s and 5.3 m/s were obtained with the speed of 90 km/h and 120 km/h, respectively. Especially, the induced winds was generated about 84% of the vehicle speed at 1.0 m above from the median strip when the vehicles travel with the speed of 120 km/h. The induced winds was maintained during the very short period while the traveling. conclusively, it is noted that the wind power generation can be possible by using the small-sized wind power generators installed on median strips throughout the analytical results in this study.

Development of high performance and low noise compact centrifugal fan for cooling automotive seats (자동차 시트 쿨링용 고성능·저소음 컴팩트 원심팬 개발)

  • Kim, Jaehyun;Ryu, Seo-Yoon;Cheong, Cheolung;Jang, Donghyeok;An, Mingi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.6
    • /
    • pp.396-403
    • /
    • 2018
  • In this paper, a high-performance and low-noise centrifugal fan is developed for cooling automotive seats which provide a driver with pleasant driving environment. First, the flow characteristics of the existing fan unit was analyzed using a fan performance tester and CFD (Computational Fluid Dynamics) simulations. The analysis of the predicted flow field indicated vortex flow near the tip of fan hub and stagnation flow on the top of fan hub. Two design points are devised to reduce the vortex flow and the stagnation flow observed in the existing fan unit. First, the cut-off clearance which is the minimum distance between the fan blade and the fan housing is increased to reduce the vortex strength and, as a result, to reduce the overall sound pressure level. Second, the hub shape is more modified to eliminate the stagnation flow. The validity of proposed design is confirmed through the numerical analysis. Finally, a prototype is manufactured with a basis on the numerical analysis result and its improved flow and noise performances are confirmed through the P-Q curves measured by using the Fan Tester and the SPL (Sound Pressure Level) levels measured in the anechoic chamber.

A comparative study of field measurements of the pressure wave with analytical aerodynamic model for the high speed train in tunnels (고속철도 터널내 압력파 측정과 공기압 해석모델에 대한 기초연구)

  • Kim, Hyo-Gyu;Choi, Pan-Gyu;Hong, Yoo-Jung;Yoo, Ji-Oh
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.319-332
    • /
    • 2015
  • The pressure wave formed by the piston effects of the train proceeds within the tunnel when a train enters the tunnel with a high speed. Depending on the condition of tunnel exit, the compression waves reflect at a open end, change to the expansion waves, transfer to tunnel entrance back. Due to interference in the pressure waves and running train, passengers experience severe pressure fluctuations. And these pressure waves result in energy loss, noise, vibration, as well as in the passengers' ears. In this study, we performed comparison between numerical analysis and field experiments about the characteristics of the pressure waves transport in tunnel that appears when the train enter a tunnel and the variation of pressure penetrating into the train staterooms according to blockage ratio of train. In addition, a comparative study was carried out with the ThermoTun program to examine the applicability of the compressible 1-D model(based on the Method of Characteristics). Furthermore examination for the adequacy of the governing equations analysis based on compressible 1-D numerical model by Baron was examined.