• 제목/요약/키워드: Aeration system

Search Result 297, Processing Time 0.024 seconds

Study to enhance the settleability of deep aeration tank MLSS (Mixed Liquor Suspended Solid) by air sparging (탈기에 의한 심층포기 호기조 MLSS (Mixed Liquor Suspended Solid) 침전성 향상 방안 연구)

  • Jisoo Han;Jeseung Lee;Byonghi Lee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.38 no.3
    • /
    • pp.165-175
    • /
    • 2024
  • The dissolved air at the bottom layer of the deep aeration tank transforms into fine gas bubbles within the MLSS (Mixed Liquor Suspended Solid) floc when exposed to the atmosphere. MLSS floc flotation occurs when MLSS from the deep aeration tank enters the secondary clarifier for solid-liquid separation, as dissolved air becomes fine air within the MLSS floc. The floated MLSS floc causes a high SS (Suspended Solid) concentration in the secondary effluent. The fine air bubbles within the MLSS floc must be removed to achieve stable sedimentation in the secondary clarifier. Fine bubbles within the MLSS floc can be removed by air sparging. The settleability of MLSS was measured by sludge volume indexes (SVIs) after air sparging MLSS taken at the end of the deep aeration tank. MLSS settling tests were performed at MLSS heights of 200, 300, 400, and 500 mm, and compressed air was fed at the bottom of the settling column with air flow rates of 100, 300, and 500 ml/min at each MLSS height, respectively. Also, at each height and air flow rate, air was sparged for 3, 5, and 7 minutes, respectively. SVI was determined for each height, air flow rate, and sparging time, respectively. Experimental results showed that a 300 mm MLSS height, 300 ml/min air flow rate, and 3 minutes of sparging time were the least conditions to achieve less than 120 ml/g of SVI, which was the criterion for good MLSS settling in the secondary clarifier.

Sedimentation and EPS Production by the Change of Dissolved Oxygen Concentration for the Aeration Tank to treat Wastewater with Bacillus sp. (바실러스 미생물을 이용한 하수처리에서 포기조의 DO농도 변화에 따른 EPS 물질생성과 슬러지 침강성에 관한 연구)

  • Lee, Sang-Ho;Son, Han-Hyung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.3
    • /
    • pp.627-631
    • /
    • 2007
  • The factors affecting on sludge sedimentation are reported as F/M ratio, ingredient, composition of influent substrate, dissolved oxygen concentration, temperature, pH, filamentous bacteria and SRT. Aeration tank applying Bacillus sp. has an important role for maintaining the dominant microorganism species to make steady progress for spore growth affecting sedimentation. This research aims to investigate the affecting factor for the sedimentation in B3 system and RABC system with aeration tank applying tapered aeration. Extracellular polymeric substances(EPS), protein and carbohydrate can be produced for the extreme condition, that is down to 0.2 mg/L of dissolved oxygen in the aeration tank. This research found out the relation between the sedimentation and the EPS production, especially the ratio of protein/carbohydrate. The spore of Bacillus sp. was formed at the low DO then microorganisms produced EPS. The results showed that the production of EPS was 109.95 mgEPS/gSS at 1.6 mg/L of DO, however it was 131.77 mgEPS/gSS at 0.5 mg/L of DO. The sedimentation was affected by protein content in EPS and the ratio of protein and carbohydrate. The settleability of sludge was not affected by the ratio of protein/carbohydrate in B3 process, meanwhile settleability was affected by the ratio of it in RABC process, respectively.

  • PDF

Effect of Agitation and Aeration Rate on Nicotiana tabacum Suspension Cell Culture in Bioreactors (Bioreactor를 이용한 담배세포 현탁배양에서 교반형태와 통기량이 미치는 영향)

  • Lee, Sang-Yun;Kim, Dong-Il
    • KSBB Journal
    • /
    • v.14 no.5
    • /
    • pp.534-538
    • /
    • 1999
  • For the optimization of operating conditions for plant cell suspension culture in bioreactors, effects of bioreactor types, various kinds of impellers, and aeration rates were examined using Nicotiana tabacum cells as a model system. Stirred tank bioreactor and airlift bioreactor were used for the comparison of bioreactor type. Growth rates in both bioreactors were lower than in shake flasks. In terms of final cell concentration, stirred tank bioreactor supported a little bit better growth compared to airlift bioreactor. Impeller type did not affect cell growth significantly, but it was apparent that cell size index decreased in the case of using hollowed paddle impeller. When the aeration rate was maintained at 0.3 vvm, cell growth was the best. At above 1.0 vvm, growth inhibition as well a browning was noticed. In addition, it was found that cell size index reduced proportionally to the increased of aeration rate.

  • PDF

Relationship Between C/N Ratio and Nitrogen Removal in Intermittently Aerated Activated Sludge System (간헐폭기 활성슬러지공정에서 C/N비와 질소제거의 관계)

  • 서인석;김병군;이상일
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.2
    • /
    • pp.57-65
    • /
    • 1998
  • In this research, Effect of C/N ratio on nutrient removal in intermittently aerated activated sludge system(IAASS) was investigated with dormitary, building and swine wastewater. Three types (2-stage, 4-stage, modified) of IAASS were operated. Time interval of aeration/nonaeration in IAASS was 1hr/1hr. In treatment of Dormitary wastewater(BOD/T-N ratio : 4.4), Building wastewater (BOD/T-N ratio : 3.14) and swine wastewater(BOD/T-N ratio : 3.84), Nitrogen removal efficiency of 80, 70 and 90.4% was achieved, respectively. Nitrogen removal in IAASS was a great influenced on influent C/N ratio, efficient nitrogen removal was achieved at BOD/T-N ratio over 4. In IAASS operation, $\Delta $BOD mg/L/$\Delta $ nitrogen mg/L ratio was about 4-6. Simultaneous removal of organic, nitrogen and phosphorus in IAASS can achieved. And influent organic was efficiently utilized in denitrification. IAASS could be one of the best alternative process for the retrofit of conventional activated sludge system for the removal of nutrients.

  • PDF

Preliminary Study on the Recycled Composting System for Reducing Bulking Agent Cost (부자재 비용 저감을 위한 순환 퇴비화 시스템의 예비연구)

  • 홍지형;최명환;박금주
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.405-410
    • /
    • 1999
  • This study was performed to find the recycling performance and to provide design data during recycle solid composting system to reduce bulking agent cost, Dairy manure amended with rice hulls and recycled compost was composted in a laboratory -scale vessel by continuous aeration for 10 days. The temperature and ammonia emission variations according to the ratios of bulking agents during the primary aeration stage were surveyed. Also, the influence of fresh compost quality on the recycling performance were anlayzed. While recycled composting system were operatured. The temperature in compost was maintained in the range of 40∼60$^{\circ}C$ needed for biodegradation and death of pathogenic organisms, but the ammonia emission was different by the ratios of recycled compost. The ammonia emission increased due to the low C/N ratio(17.6), high pH value(8.1) of the recycled compost.

  • PDF

Study on the Standard Oxygen Transfer Efficiency Monitoring System in the Aeration Tank for Reuse and Discharge of Wastewater (하폐수의 재사용 및 방류를 위한 폭기조 내 표준산소전달 효율 모니터링 시스템에 관한 연구)

  • Kim, Hong-Seok;Kim, Yong-Beom;Ko, Kyung-Han;Kim, Sang-Woo;Shim, Hwan-bo
    • Resources Recycling
    • /
    • v.28 no.6
    • /
    • pp.73-78
    • /
    • 2019
  • In this investigation, off-gas generated from the activated sludge in wastewater treatment plant was monitored. Through monitoring, the oxygen transfer efficiency in the aeration system and the reliability was evaluated by comparing to clean water. First, the dissolved oxygen, oxygen transfer coefficient, and standard oxygen transfer efficiency were measured based on clean water, and the values were 8.60 mg/L, 9.490/hr and 23.96%, respectively. The off-gas monitoring at the wastewater treatment plant indicated that the standard oxygen transfer efficiency was 22.81%. Little difference in oxygen transfer efficiency this data inferred that the performance was improved through diffuser installation in the field monitoring system.

Model Development of Aeration System using Small Wind Turbine (소형 풍력 터빈을 이용한 폭기시스템 모델 개발)

  • Kim, Myoung-Jun;Chea, Gyu-Hoon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.1
    • /
    • pp.59-65
    • /
    • 2013
  • In recent years, the crisis of energy is growing seriously and also the contamination of ecology has been reverberated as international problem. The social concerns on energy crisis have been growing for the last several years and also the interests in new and renewable energy have been increased. Therefore, in order to solving these problems, as solution of one, this paper is investigated using the aeration system at the fish farm, etc from nature energy such as wind power. This study suggests the fundamental data of designing for these similar apparatus and examines the parameters of wind velocity and wind receiving area. Especially, the water outlet position was mainly investigated with optimum outlet angle of wind pump.

Optimum Geometry of Glass Lined HOMEBASE Impeller for Gas-Liquid System of Low Viscosity Liquid (저점도 액 통기 교반용 글라스라이닝 홈베이스 임펠러의 최적 형상)

  • Koh, Seung-Tae
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.542-547
    • /
    • 2021
  • Glass lined impellers are corrosion resistant to most chemicals, including strong acids, and also have a smooth, non-stick surface, easy to clean and free from impurities in the process. Glass lined home base impeller is a multi-purpose impeller designed to stir a wide viscosity range of liquids from low viscosity fluids to high viscosity fluids, among others, cell culture, yeast culture, and beer fermentation pots, especially used for air-water system breathable stirring. The glass lining for HB impellers, which are simple in structure and competitive in performance, is essential to have upper and lower division in order to make the joint area between the impeller and shaft as small as possible. The upper and lower division of the impeller hardly affects the mixing performance, but the aeration performance. In this study, in order to optimize the shape of the Glass Lining HB impeller, a study was conducted on the effect of the angle between the upper and lower impellers, the clearance between the impellers, and the number of baffles on the aeration power. The optimal shape and baffle plate conditions for the Glass lined HB impeller were derived through the study results that the angle and the clearance between the upper and lower impellers decreased the ration of the power consumption with aeration Pg and that without aeration P0, Pg/P0.

The Effect of Coagulant on Filtration Performance in Submerged MBR System (침지형 MBR 공정에서 응집제가 여과성능에 미치는 영향)

  • Kim Kwan-Yeop;Kim Ji-Hoon;Kim Young-Hoon;Kim Hyung-Soo
    • Membrane Journal
    • /
    • v.16 no.3
    • /
    • pp.182-187
    • /
    • 2006
  • The purpose of this study was to investigate effect of coagulation on filtration performance of membrane in submerged MBR system and influence of continuous aeration to reduce fouling of membrane surface on coagulated floc. For this purpose, aeration tank sludge of MBR system was compared with jar-test sludge. The experimental results were analysed in terms of floc size and SRF (Specific resistance of Filtration). The more alum was added, the more content of floc below $10{\mu}m$ reduced and SRF decreased. But compared with jar-test results, it was found that effect of coagulation on MBR floc was reduced. Operation time of membrane in alum added MBR was longer than that in control MBR. But operation time was not proportional to alum dose. It was thought that the result was reason that floc below $10{\mu}m$ was not reduced sufficiently by shear force of continuous aeration. Moreover it was founded that if alum is added more than proper dose, it brings filtration resistance to increase.