• 제목/요약/키워드: Aeration efficiency

검색결과 230건 처리시간 0.023초

Performance of a Biofilter for Odor Removal during Manure Composting

  • Park, K.J.;Hong, J.H.;Choi, M.H.
    • Agricultural and Biosystems Engineering
    • /
    • 제3권2호
    • /
    • pp.59-64
    • /
    • 2002
  • Odor generated during composting of livestock manure is mainly due to ammonia emission. Biofiltration is a desirable method to control composting odor. This study was conducted to analyze the efficiency of using fresh compost as a biofilter. A mixture of cattle manure and recycled compost was composted in a bin equipped with a suction-type blower. The exhaust gas was filtered through the fresh compost. Residence time was controlled by the flow rate of exhaust gas and the depth of filtering materials. At the aeration rate of 30 L/min(experiment I), ammonia reduction rate varied from 100% to -15% for biofilter A(residence time 56.5 s) and almost 100% for biofilter B(residence time 113 s). At the aeration rate of 30 L/min, the cumulative ammonia reduction rate was 80.5% for biofilter A and 99.9% for biofilter B. At the aeration rate of 50 L/min(experiment II), the lowest reduction rate showed a negative value of -350% on the 8th and 9th day for biofilter A(residence time 33.9 5), and 50% on the loth day for biofilter B(residence time 67.8s). At the aeration rate of 50 L/min, the cumulative ammonia reduction rate was 82.5% fur biofilter A and 97.4% for biofilter B. Filtering efficiency was influenced by residence time. The moisture content(MC) and total nitrogen(T-N) of the filtering material were increased by absorbing moisture and ammonia included in the exhaust gas, while pH was decreased and total carbon(T-C) remained unchanged during the filtering operation.

  • PDF

양돈분뇨의 암모니아 저감을 위한 갈탄, 참숯 첨가제의 효능 분석 (Ammonia Reduction from Swine Manure Slurry with Additives of Brown Coal and Oak Charcoal)

  • 황현섭;오인환;장영수
    • 한국축산시설환경학회지
    • /
    • 제14권2호
    • /
    • pp.91-96
    • /
    • 2008
  • The odours from spreading the slurry, manure storage tanks, and the stall are a source of annoyance for the neighbors and sometimes even become a case for civil appeal. Reducing the odourant and ammonia emission is an urgent need to be addressed. It is known that brown coal and oak charcoal have an ability to absorb odour. We designed an experiment set in lab scale and used the brown coal and oak charcoal as additives in the test to reduce odour. The test are divided into two categories; namely aeration and no-aeration. The additives were added to the each sample at a concentration of 5% and 10% of total base solids, besides the control samples. We carried out the Phenate Method for ammonia analyzing. In the non-aerated case, the results showed a reducing efficiency of 23.7% and 26.4% with an addition rate of 5% and 10% of additives, respectively. In the aerated test, the reducing efficiency of ammonia was 17.8% and 21.0% with an addition rate of 5% and 10% of additives, respectively. In case of oak charcoal, non-aeration showed removal efficiencies of ammonia at 15.9% and 16.1% with addition rates of 5% and 10%, respectively, With aeration, they were 11.4% and 26.4% with addition rates of 5% and 10% oak charcoal, respectively. The tests show that brown coal and oak charcoal have a reducing effect on ammonia emissions.

  • PDF

소규모 간이상수도 시설에서 수온과 폭기량 변화에 따른 수중 라돈 제거 효율에 관한 연구 (A Study on Radon Removal Efficiencies in Drinking Water according to the Variations of Water Temperature and Aeration Rate in Small Waterwork Facility)

  • 김현구;최정수;주현종;김성철
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권3호
    • /
    • pp.52-57
    • /
    • 2013
  • Radon, which is one of the radioactive elements in the natural world, exists in the atmosphere and water. When this element inflows into the human body, it carries the risks of developing lung cancer and stomach cancer. Therefore, in this study, an effective 10 L scaled reactor was produced to mitigate radon in water and the radon mitigation efficiency in water following the changes in water temperature and amount of aeration were evaluated. Based on this, the radon mitigation efficiency (SRRR; Specific radon removal rate) was derived per unit air volume. According to the study result, when water temperature increased from $10^{\circ}C$ to $16^{\circ}C$, the SRRR value increased from 95 $nCi/m^3{\cdot}L$ to 134.4 $nCi/m^3{\cdot}L$, and when the amount of aeration increased from 0.2 L/min to 1 L/min, the SRRR value decreased from 198.1 $nCi/m^3{\cdot}L$ to 72.2 $nCi/m^3{\cdot}L$. Therefore, based on the experimental results, it is considered that it can be applied as a examination factor and objective indicator during the design of future radon-in-water mitigation systems.

Optimum Operation of a PVDF-type Hollow Fiber Membrane Bioreactor for Continuous Sewage Treatment

  • Shin, Choon-Hwan
    • 한국환경과학회지
    • /
    • 제19권11호
    • /
    • pp.1315-1322
    • /
    • 2010
  • A membrane bioreactor (MBR) was designed using polyvinylidene fluoride(PVDF)-type hollow fiber membrane modules with a treatment capacity of 10 ton/day. A pilot plant was installed in a sewage treatment plant and was operated with an intermittent aeration method which avoids any concentration gradient of suspended solids (SS) in the MBR. For continuous operation, the pilot plant was first tested with influent (mixed liquor suspended solid:MLSS of 1000-2000 mg/L) of aeration tanks in the sewage treatment plant. The MBR was pre-treated with washing water, 10% ethanol solution, 5% NaOCl solution and finally washing water, one after another. To demonstrate the effect of the MBR on sewage treatment, compared with conventional activated sludge processes, we investigated the relationships among permeate amount (LMH), change in operation conditions, influent MLSS level and sludge production. It was found that the optimum aeration rate and suction pressure were $0.3\;m^3$/min and 30~31 cmHg, respectively. Under stable conditions in aeration, suction pressure, influent flow rate and drainage, the SS removal efficiency was more than 99.99% even when the MLSS loading rate changes. Compared with conventional activated sludge processes, the MBR was more effective in cost reduction by 27% based on permeate amount and by 51.5% on sludge production.

Study on Flow Instability and Countermeasure in a Draft tube with Swirling flow

  • Nakashima, Takahiro;Matsuzaka, Ryo;Miyagawa, Kazuyoshi;Yonezawa, Koichi;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • 제8권4호
    • /
    • pp.230-239
    • /
    • 2015
  • The swirling flow in the draft tube of a Francis turbine can cause the flow instability and the cavitation surge and has a larger influence on hydraulic power operating system. In this paper, the cavitating flow with swirling flow in the diffuser was studied by the draft tube component experiment, the model Francis turbine experiment and the numerical simulation. In the component experiment, several types of fluctuations were observed, including the cavitation surge and the vortex rope behaviour by the swirling flow. While the cavitation surge and the vortex rope behaviour were suppressed by the aeration into the diffuser, the loss coefficient in the diffuser increased by the aeration. In the model turbine test the aeration decreased the efficiency of the model turbine by several percent. In the numerical simulation, the cavitating flow was studied using Scale-Adaptive Simulation (SAS) with particular emphasis on understanding the unsteady characteristics of the vortex rope structure. The generation and evolution of the vortex rope structures have been investigated throughout the diffuser using the iso-surface of vapor volume fraction. The pressure fluctuation in the diffuser by numerical simulation confirmed the cavitation surge observed in the experiment. Finally, this pressure fluctuation of the cavitation surge was examined and interpreted by CFD.

수중폭기용 노즐형 산기관 개발에 관한 연구 (Study on the Development of Nozzle-Type Diffusers for Submersible Aeration Process)

  • 임동렬;이상규
    • 한국유체기계학회 논문집
    • /
    • 제8권5호
    • /
    • pp.7-12
    • /
    • 2005
  • Experimental study was conducted to increase the oxygen transfer efficiency of air diffusers in clean water. By measuring the bubble size from the bubbly two-phase flow visualization with several air diffusers, the size of air bubbles near the top surface of aeration tank seems to be independent on the diffuser types. Considering design parameters for the better break-up of larger bubbles around the air diffusers, advanced conceptual air diffusers using nozzle-type throat showing the higher oxygen transfer efficiencies were made.

자화-생물처리 시스템에 의한 염색폐수의 처리 (Treatment of Dyeing Wastewater by Magnetic-Biological Treatment System)

  • 이선하
    • 한국환경과학회지
    • /
    • 제19권3호
    • /
    • pp.371-377
    • /
    • 2010
  • The purpose of this study is to investigate treatment efficiency in dyeing wastewater treatment by the high rate aeration system(HRA) and a combination of the HRA with magnetized wastewater treatment system(MWS). At the hydraulic retention time of 16hr, 24hr, 30hr, BOD removal efficiencies of HRA system were 93%, 96% and 98%, combination of the HRA with MWS system were 94%, 96.8% and 98.2%, respectively. In ease of COD, at the hydraulic retention time of 16hr, 24hr, 30hr, COD removal efficiencies of HRA system were 66%, 77.1% and 83.1%, combination of the HRA with MWS system were 70.2%, 80.1% and 86.6%, respectively. The comparison of the HRA and combination of the HRA with MWS, effluent BOD of the former was 22.7mg/${\ell}$ and the latter was 19.4mg/${\ell}$, theretore biological treatment efficiency identified to increase by the MWS.

분뇨처리장의 공정개선에 의한 처리효율 향상에 관한 연구 (Improvement of treatment efficiency for sanitary treatment facilities by process modifications)

  • 이찬원;김승현;김창수;문성원;전홍표;윤종섭
    • 한국환경과학회지
    • /
    • 제13권6호
    • /
    • pp.571-579
    • /
    • 2004
  • There is a need to improve the efficiency of the existing sanitary treatment facilities, because the effluent standard becomes more stricter and septic sludge increased. Thus, operating processes of sanitary treatment system in M city changed with installation of additional facilities. Process modifications were as follows: Dilution water was added to the next process after primary aeration tank. Some secondary sedimentation sludge was recycled to primary aerator so that most of the organics were stabilized in primary aeration tank under automatic control of dissolved oxygen. The line of effluent from dewatering process flowing to the activated sludge tank was changed to the primary aerator. The primary sedimentation sludge line was linked to a thickener. Polymer was added to the activated sludge tank. The effluent of primary aerator and aerobic digester was recycled from the 5th to the 1st sector. As consequencies of above process modifications, the improvement of removal efficiency was achieved as BOD 54%, COD 42%, SS 61%, T-N 39%, and T-P 12%, respectively.

바실러스 미생물을 이용한 고농도 유가공 폐수처리에 있어서 유기물질과 영양염류의 동시제거에 대한 평가 (Evaluation for the simultaneous Removal of Organic Matters and Nutrients by the RBC and tapered Aeration Processes with Bacillus sp. for the high Strength of Dairy Wastewater)

  • 이상호
    • 상하수도학회지
    • /
    • 제24권2호
    • /
    • pp.195-202
    • /
    • 2010
  • The evaluation of organic matters and nutrients removal was investigated for the synthetic wastewater and the high strength of dairy wastewater. Two different systems were performed for this research. System A composing of a single RBC with tapered aeration was fed with the synthetic wastewater for 74 days with 173L/day of influent, 200% of internal return and 100% of sludge return for the period 1 and 2. The feed conditions were maintained 346L/day of influent, 50% of internal return and sludge return for the period 3. The dairy wastewater was introduced to evaluate treatment efficiency for system B composing of dual RBCs and tapered aeration tanks for 50 days of experimental run time, in which hydraulic rates were maintained at the constant ratios of 346L/day, 50% of internal return and 50% of sludge return. The spiral string media made of nylon fibre was attached by Bacillus sp. in RBC for both systems. The specific area of string media was $1.4m^2$/m and biomass was maintained at the concentrations of 23g/m. The synthetic wastewater was supplied by 1,800mg/L of glucose, 500mg/L of $NH_4Cl$, and 500mg/L of $KH_2PO_4$ to system A. The dairy wastewater was supplied to system B from dairy production plant. The average influent concentrations were 1,334mg/L of BOD, 2,014mg/L of CODcr, 160mg/L of T-N, and 12mg/L of T-P in system A. The average influent concentrations of parameters were 1,006 mg/L for BOD, 1,875mg/L for $COD_{cr}$, 51.6mg/L for T-N and 8.9mg/L for T-P in system B. Results indicated that removal efficiencies of BOD and $COD_{cr}$ were more than 90% however, the removal efficiency of T-N was 87%, and that of T-P was 82% for system A. Removal efficiencies were 98.5% of BOD, 91.3% of nitrogen and 89% of phosphorus for system B. The removal efficiencies of organic matters, T-N and T-P were higher in system B than in system A. The effluent quality issued by the stringent national legislations for the discharge of the high strength of dairy products wastewater can be improved using sequential RBCsand tapered aeration reactors rather than a single RBC and tapered aeration reactors with Bacillus sp.

Bench-scale 선박용 고도수처리장치에서의 T-N 제거효율 연구 (A Study on Removal Efficiency of T-N in Bench-scale for Shipboard Sewage Treatment Plant)

  • 최영익;신대열;이승철;정진희;윤영내
    • 한국환경과학회지
    • /
    • 제27권1호
    • /
    • pp.39-45
    • /
    • 2018
  • In this study, the International Maritime Organization (IMO)'s guideline MEPC. 277 (64) was developed and evaluated for the removal efficiency of T-N in a SBR and MBR combined process. This combined process of resized equipment based on large capacity water treatment device for a protection of marine aquatic life. In this experiment, T-N concentration of influent and effluent was measured through with the artificial wastewater. The SBR reactor operation time was varied according to the C : N : P ratios so that different conditions for mixing and aeration period in mins (90 : 60, 80 : 40, 70 : 50) and two C: N: P ratios (10 : 5 : 3, 10 : 3 : 1) were used. During experiment in the reactor's aeration and anoxic tank DO concentrations were 3 mg/L and 0.2 mg/L respectively. Furthermore, in the reactor MLSS concentration was 2000 mg/L and flowrate was 2 L/hr. Experiment results showed that C : N : P, 10 : 3 : 1 ratio with 90 mins mixing and 60 mins aeration maximized removal efficiency at 97.3% T-N as compared to other conditions. The application of the SBR and MBR combined process showed efficient results.