• 제목/요약/키워드: Advanced type

검색결과 4,144건 처리시간 0.034초

ABC 배전방식의 전망과 현장 적용상의 문제점 검토 (The Prospect and the Problems at Site of ABC-type Distribution)

  • 박중신;이수묵;강원구;김승돈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.504-506
    • /
    • 2000
  • In other advanced countries, an ABC-type distribution was employed few decades ago. It was, however, introduced, in this country, in late 1999. In order to apply it to the sites, several things have to be improved to comply with Korean distribution condition. It is very important to investigate the prospect and the problems in applying this type of distribution at site. To effectively employ it at site ASAP, follows have to be considered: easy installation of a transformer the development of branch gear, easy connections, the preventive diagnosis technique of insulating materials for ABC applications, etc. This paper describes the problems and the advanced plans of ABC-type distribution, and in construction.

  • PDF

3GPP LTE-Advanced을 위한 Relay 개선 방안 (The Improvements for 3GPP LTE-Advanced Relay)

  • 박병성;김상하;장일두;이희봉;권경인
    • 한국통신학회논문지
    • /
    • 제36권12B호
    • /
    • pp.1647-1658
    • /
    • 2011
  • 본 논문에서는 3GPP LTE-Advanced에서 지원하고 있는 Relay Node의 FDD 모드에서 무선 백홀 링크 성능 향상을 위한 방안을 제안한다. 백홀 링크에서 Carrier Aggregation을 적용하기 위한 고려 사항을 살펴보고 이를 위한 RRC (Radio Resource Control) 메시지와 Relay startup 절차를 제안한다. 또한 Type 1 Relay에서 백홀과 엑세스 링크사이의 full-duplexing 가능한 reference signal를 설계하여 자원 활용을 극대화 할 수 있는 방안을 제시한다. 마지막으로 본 논문에서는 LTE Release 10 Relay의 백홀 자원 할당 방법내에서 주기적으로 전송되는 상향 제어 정보 및 무선 채널 정보의 효율적인 전송 방법을 제안한다. 이후의 3GPP RAN(Radio Access Network) 표준화는 LTE-Advanced 요소 기술들을 개선시키는 방향으로 진행될 것으로 예상되기 때문에 본 논문에서 제안된 기술들에 대한 표준 채택 논의가 활발히 진행될 것으로 기대된다.

아치형 복부판 보강재가 설치된 플레이트거더 강합성교의 구조적 거동특성 (Structural Characteristics of Steel-Concrete Composite Plate Girder with Arch-Type Web Stiffener)

  • 우상벽;유종호;이홍규;원용석;김선희;윤순종
    • 복합신소재구조학회 논문집
    • /
    • 제6권4호
    • /
    • pp.1-7
    • /
    • 2015
  • In this paper, we present the result of analytical investigation pertaining to the structural behavior of steel-concrete composite plate girder with arch-type web stiffener. In the arch-type web stiffener located in the compression side of web, infill concrete is cast to strengthen the arch-type stiffener and also to exert resisting force against compression force. This type of composite steel-concrete plate girder bridge is built and is in service. To understand the behavior thoroughly, analytical parametric study was conducted by using the finite element method. As a result it was found that the effect of arch-type stiffener with infill concrete is considerable for the design of such type composite girder bridge.

CGL의 재료에 따른 청색 형광 Tandem OLED의 발광 특성 (Emission Characteristics of Blue Fluorescence Tandem OLED with Materials of CGL)

  • 곽태호;주성후
    • 한국표면공학회지
    • /
    • 제47권4호
    • /
    • pp.210-214
    • /
    • 2014
  • We investigated emission characteristics of tandem organic light emitting devices (OLEDs) with p-type materials as charge generation layer. The tandem OLEDs were fabricated by using $MoO_x$, $WO_x$, C60 and HATCN as p-type material or not using p-type material for charge generation. When HATCN was used as p-type material, it showed high current density at low applied voltage, but increase of efficiency was small because of charge unbalance in emitting layer. In case of tandem OLED not using p-type material, applied voltage increased remarkably because of difficulty of hole injection. In case of $MoO_x$, $WO_x$ or C60 as p-type material, current emission efficiency increased greatly. In particular, current emission efficiency of tandem OLED using $MoO_x$ as p-type material increased up to 3 times than current emission efficiency of single OLED. The Commission Internationale de l'Eclairage (CIE) 1931 color coordinates were changed by overlapping of 504 nm emission wavelength. As a result, emission efficiency of tandem OLED improved compared with single OLED, but driving voltage also increased by increase of organic layer thickness.

Operational Envelope of a 150 kW Huels Type Arc-jet

  • Na, Jae-Jeong;Moon, Kwan-Ho;Hong, Yun-Ky;Baek, Seung-Wook;Park, Chul
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.187-195
    • /
    • 2006
  • In this work, we introduce a newly constructed arc-jet device of 150 kW input power. The design of this device is a Huels type with a narrow downstream electrode. General features of this device are first described. From the measured values of electrical power input, heat discharged into cooling water, gas flow rate, and settling chamber pressure, average enthalpy was determined using the heat balance and sonic throat methods. Using the settling chamber pressure and average enthalpy values, the flow properties in the nozzle and the heat transfer rate to the stagnation point of a blunt body are calculated accounting for thermochemical nonequilibrium. The envelope of enthalpy, pressure, degree of dissociation, and heat transfer rate are presented. Stagnation temperature is predicted to be between 4630 to 6050 $^{\circ}K$, and the stagnation point heat transfer rate is predicted to be between 175 and 318 W/$cm^{2}$ for a blunt body of 3 mm nose radius. Degree of dissociation in the stagnation region of the blunt body exceeds 30%.

  • PDF

Visual Inspection of Tube Internal

  • Choi, Young-Soo;Cho, Jai-Wan;Kim, Chang-Hoi;Seo, Yong-Chil;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.789-792
    • /
    • 2003
  • Pipe inspection has a great importance to ensure safety for the nuclear power plant. In this paper, we designed visual inspection module for the tube internal, which diameter is 15${\sim}$20mm. And we made inspection module which consisted of CCD camera and light. And the relation between image and real world coordinate is established. Image processing is performed to calculate mapping parameter and analyze the size of defect. For the calculation of mapping parameter, experiment is performed using grid type test pattern. Acquired image is processed to extract image coordinate. Edge detection, thresholding, median filtering and morphology filtering is applied to extract grid pattern. Extracted image coordinate is used to calculate image to real world mapping. Lens distortion was considered and corrected to get exact data. Coordinate transformation data is provided for the users to recognize easily. Experiment was performed using grid type test pattern, we extracted lens distortion parameter and real coordinate of defect point. Radial distortion of lens was corrected but tangential distortion was not considered. As continuum to this study, the tangential distortion of lens is considered and improvement of analy zing technique for the tube internal be explored continuously.

  • PDF

탄성 힌지 타입 레버 메커니즘을 이용한 자동 초점 조절 미세구동장치에 대한 연구 (A study on fine actuating stage for autofocus by using flexure-hinge type lever mechanism)

  • 이재석;홍석인;김호상;장한기;이경돈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.665-666
    • /
    • 2006
  • In precision laser microfabrication, focusing is essential to acquire good machining precision and uniform machining quality. If it does not perform, laser machining cannot be realized. So, confocal scanning method with high depth resolution is used for focus detection technique. This paper is concerned with a procedure for design, analysis and performance test of an autofocus fine actuating stage, which is composed of flexure-hinge type lever mechanism and piezoelectric actuator. Through series of analytical design, the stage is simplified as a rigid bodies(lever and main body) and springs(flexure hinges). The simplified model was applied to determine the dimension of flexure hinges and lever. After structural analysis confirmed design requirement, an actual stage was made and verified through an experiment on the static and dynamic characteristics(maximum stroke and 1st natural frequency). The fabricated stage was satisfied with the design requirement.

  • PDF

Plant-scale experiments of an air inflow accident under sub-atmospheric pressure by pipe break in an open-pool type research reactor

  • Donkoan Hwang;Nakjun Choi;WooHyun Jung;Taeil Kim;Yohan Lee;HangJin Jo
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1604-1615
    • /
    • 2023
  • In an open-pool type research reactor with a downward forced flow in the core, pipes can be under sub-atmospheric pressure because of the large pressure drop at the reactor core in the atmospheric pool. Sub-atmospheric pressure can result in air inflow into the pipe from the pressure difference between the atmosphere and the inside of the pipe, which in a postulated pipe break scenario can lead to the breakdown of the cooling pump. In this study, a plant-scale experiment was conducted to study air inflow in large piping systems by considering the actual operational conditions of an advanced research reactor. The air inflow rate was measured, and the entrained air was visualized to investigate the behavior of air inflow and flow regime depending on the pipe break size. In addition, the developed drift-flux model for a large vertical pipe with a diameter of 600 mm was compared with other correlations. The flow regime transition in a large vertical pipe under downward flow was also studied using the newly developed drift-flux model. Consequently, the characteristics of two-phase flow in a large vertical pipe were found to differ from those in small vertical pipes where liquid recirculation was not dominant.

Monocytes Contribute to IFN-β Production via the MyD88-Dependent Pathway and Cytotoxic T-Cell Responses against Mucosal Respiratory Syncytial Virus Infection

  • Tae Hoon Kim;Chae Won Kim;Dong Sun Oh;Hi Eun Jung;Heung Kyu Lee
    • IMMUNE NETWORK
    • /
    • 제21권4호
    • /
    • pp.27.1-27.12
    • /
    • 2021
  • Respiratory syncytial virus (RSV) is the leading cause of respiratory viral infection in infants and children. However, little is known about the contribution of monocytes to antiviral responses against RSV infection. We identified the IFN-β production of monocytes using IFN-β/YFP reporter mice. The kinetic analysis of IFN-β-producing cells in in vivo RSV-infected lung cells indicated that monocytes are recruited to the inflamed lung during the early phase of infection. These cells produced IFN-β via the myeloid differentiation factor 88-mediated pathway, rather than the TLR7- or mitochondrial antiviral signaling protein-mediated pathway. In addition, monocyte-ablated mice exhibited decreased numbers of IFN-γ-producing and RSV Ag-specific CD8+ T cells. Collectively, these data indicate that monocytes play pivotal roles in cytotoxic T-cell responses and act as type I IFN producers during RSV infection.

Differentiation of Benign from Malignant Adnexal Masses by Functional 3 Tesla MRI Techniques: Diffusion-Weighted Imaging and Time-Intensity Curves of Dynamic Contrast-Enhanced MRI

  • Malek, Mahrooz;Pourashraf, Maryam;Mousavi, Azam Sadat;Rahmani, Maryam;Ahmadinejad, Nasrin;Alipour, Azam;Hashemi, Firoozeh Sadat;Shakiba, Madjid
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권8호
    • /
    • pp.3407-3412
    • /
    • 2015
  • Background: The aim of this study was to evaluate and compare the accuracy of diffusion-weighted imaging (DWI), apparent diffusion coefficient (ADC) value, and time-intensity curve (TIC) type analysis derived from dynamic contrast-enhanced MR imaging (DCE-MRI) in differentiating benign from malignant adnexal masses. Materials and Methods: 47 patients with 56 adnexal masses (27 malignant and 29 benign) underwent DWI and DCE-MRI examinations, prior to surgery. DWI signal intensity, mean ADC value, and TIC type were determined for all the masses. Results: High signal intensity on DWI and type 3 TIC were helpful in differentiating benign from malignant adnexal masses (p<0.001). The mean ADC value was significantly lower in malignant adnexal masses (p<0.001). An ADC value< $1.20{\times}10^{-3}mm^2/s$ may be the optimal cutoff for differentiating between benign and malignant tumors. The negative predictive value for low signal intensity on DWI, and type 1 TIC were 100%. The pairwise comparison among the receiver operating characteristic (ROC) curves showed that the area under the curve (AUC) of TIC was significantly larger than the AUCs of DWI and ADC (p<0.001 for comparison of TIC and DWI, p<0.02 for comparison of TIC and ADC value). Conclusions: DWI, ADC value and TIC type derived from DCE-MRI are all sensitive and relatively specific methods for differentiating benign from malignant adnexal masses. By comparing these functional MR techniques, TIC was found to be more accurate than DWI and ADC.