Development of wearable Range of Motion measurement device capable of dynamic measurement

  • Song, Seo Won;Lee, Minho;Kang, Min Soo
    • International journal of advanced smart convergence
    • /
    • v.8 no.4
    • /
    • pp.154-160
    • /
    • 2019
  • In this paper, we propose the miniaturization size of wearable Range of Motion(ROM) and a system that can be connected with smart devices in real-time to measure the joint movement range dynamically. Currently, the ROM of the joint is directly measured by a person using a goniometer. Conventional methods are different depending on the measurement method and location of the measurement person, which makes it difficult to measure consistently and may cause errors. Also, it is impossible to measure the ROM of joints in real-life situations. Therefore, the wearable sensor is attached to the joint to be measured to develop a miniaturize size ROM device that can measure the range of motion of the joint in real-time. The sensor measured the resistance value changed according to the movement of the joint using a load cell. Also, the sensed analog values were converted to digital values using an Analog to Digital Converter(ADC). The converted amount can be transmitted wireless to the smart device through the wearable sensor node. As a result, the developed device can be measured more consistently than the measurement using the goniometer, communication with IoT-based smart devices, and wearable enables dynamic observation. The developed wearable sensor node will be able to monitor the dynamic state of rehabilitation patients in real-time and improve the rapid change of treatment method and customized treatment.

Development of a Ring-type Wearable Healthcare Device (반지 형태의 웨어러블 헬스케어 디바이스 개발)

  • Baek, Hyun Jae;Cho, Jaegeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.892-897
    • /
    • 2018
  • Due to population aging, an increase in the number of patients with chronic illnesses, and an increase in the number of single-person households, monitoring of health status in everyday life without the need for a hospital has become very important. For this reason, researches on various health care devices have been attempted, among which wearable devices are attracting much attention. In this paper, we propose a new ring-type wearable device for next generation healthcare. On the inner side of the ring, a metal electrodes for GSR measurement and an optical sensor for measurement of pulse wave signals of two wavelengths of red and near-infrared light were mounted. In addition, it was equipped with an acceleration sensor, and information about the degree of motion could be obtained. In this paper, it is shown that a health monitoring device can be implemented in the form of a ring, and the measured signals can be used to calculate heart rate, oxygen saturation, sleep time and sleep efficiency. Through the advanced algorithm, it is expected that we can extract various health information, especially sleep related health information by using the ring device, and it is also expected that it can contribute to the implementation of wearable healthcare effectively.

Does the maxillary anterior ratio in Korean adults follow the Golden Proportion?

  • Jin, Ming-Xu;Hong, Min-Ho;Lee, Kee-Joon;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.125-130
    • /
    • 2016
  • PURPOSE. The purpose of this study was to determine the effect of changes in the horizontal plane angle on the mesiodistal width ratios of the maxillary anterior teeth during the acquisition of frontal view photographs, derive these ratios for Korean adults on the basis of the data obtained, and analyze them using the Golden Proportion as a reference. MATERIALS AND METHODS. In experiment I, 30 plaster casts were mounted on an articulator and positioned on the angle-measuring device with a center setting of $0^{\circ}$. The device was rotated to $10^{\circ}$ in $1^{\circ}$ increments in a counterclockwise direction. At each angle, photographs were obtained and analyzed. Experiment II was based on 60 patients who visited the Department of Prosthodontics at Kyungpook National University Dental Hospital from February 2012 to February 2015. The patients were divided into three groups [Male (M), Female (F), Total (M + F)]. Frontal views were obtained for all groups and analyzed. RESULTS. From $1^{\circ}$ to $10^{\circ}$, the relative mesiodistal width ratios for the maxillary anterior teeth showed no significant differences from those at $0^{\circ}$. In all three groups, the relative width ratio of the maxillary central incisor was smaller than that specified in the Golden Proportion; the opposite was true for the canine. CONCLUSION. Our results suggest that the mesiodistal width ratios of the maxillary anterior teeth do not follow the Golden Proportion in Korean adults, and that a change in the horizontal plane angle from $1^{\circ}$ to $10^{\circ}$ during frontal photography does not affect these ratios.

Packaging MEMS, The Great Challenge of the $21^{st}$ Century

  • Bauer, Charles-E.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2000.04a
    • /
    • pp.29-33
    • /
    • 2000
  • MEMS, Micro Electro-Mechanical Systems, present one of the greatest advanced packaging challenges of the next decade. Historically hybrid technology, generally thick film, provided sensors and actuators while integrated circuit technologies provided the microelectronics for interpretation and control of the sensor input and actuator output. Brought together in MEMS these technical fields create new opportunities for miniaturization and performance. Integrated circuit processing technologies combined with hybrid design systems yield innovative sensors and actuators for a variety of applications from single crystal silicon wafers. MEMS packages, far more simple in principle than today's electronic packages, provide only physical protection to the devices they house. However, they cannot interfere with the function of the devices and often must actually facilitate the performance of the device. For example, a pressure transducer may need to be open to atmospheric pressure on one side of the detector yet protected from contamination and blockage. Similarly, an optical device requires protection from contamination without optical attenuation or distortion being introduced. Despite impediments such as package standardization and complexity, MEMS markets expect to double by 2003 to more than $9 billion, largely driven by micro-fluidic applications in the medical arena. Like the semiconductor industry before it. MEMS present many diverse demands on the advanced packaging engineering community. With focused effort, particularly on standards and packaging process efficiency. MEMS may offer the greatest opportunity for technical advancement as well as profitability in advanced packaging in the first decade of the 21st century! This paper explores MEMS packaging opportunities and reviews specific technical challenges to be met.

  • PDF

Development of Controllable Cannular Catheter using Bio Shape Memory Alloy (SMA) during Percutaneous Minimally Invasive Spine Surgery (경피적 최소침습 척추시술 중 디스크 내에서 방향제어가 가능한 Bio-SMA 캐뉼라 카테터의 개발)

  • Kim, Cheol-Woong
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.378-383
    • /
    • 2007
  • As the Minimally Invasive Surgery (MIS) is developed, an interventional procedure becomes the major of the spine surgery in the world. Despite of the use of the expensive medical equipments, the success chance of the nucleoplasty is about 30%. The reason is that the shape of the cannular needle is similar to that of the conventional injector and looks like the straight. Because the tip of these straight needles is not able to reach in the vicinity of the disc bulging or the protrusion, which are the cause of the low back pain and because the far indirect plasma discharge results in the decompression, the nucleoplasty has the limit. Many incurable diseases has not been solved due to the unexistence of the advanced technique for the MIS human body cannula device. If 3-D direction controllable cannular catheter (whose direction is accurately controlled after inserting into the bodies to cure the lesion) is developed, it is expected that new devised cannular catheter can cure many incurable diseases simultaneously. Therefore, the aims of this research are to develop the new devised cannular catheter of SMA direction controller for the medical situation, which has been produced through many previous trial-error procedures, and to produce the commercial medical device.

  • PDF

Research and consideration on the evaluation of usability formation of focused ultrasonic stimulation systems (집속형 초음파 자극 시스템의 사용적합성 형성평가에 대한 연구 및 고찰)

  • Kim, Jun-tae;Kim, Ju-hee;Joo, Kyu-tai;Kim, Kyung-ah;Ryu, Ok-su;Jo, Jae-hyun;Jeong, Jin-Hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.164-177
    • /
    • 2022
  • Medical device usability evaluation refers to the evaluation of medical devices through actual users before the final prototype production is completed. IEC 62366, one of the international safety standards for electronic medical devices, is a standard that must be applied to obtain medical device licenses in major advanced countries such as Europe and the United States. In Korea, through the Ministry of Food and Drug Safety's notice, from January 2021, sequential application by grade has been implemented. In this study, 15 participant specialists were recruited through the Incheon G University Hospital Medical Device Convergence Center for formative evaluation during user suitability evaluation of the focused ultrasound stimulation system being developed by Icleo Co., Ltd., and the test was conducted through joint scenario development. . In the result of task performance, the performance rate was 90.67%, and after the completion of the performance, 86.67% of 'Easy user interface' and 94% of 'Identification/Readability/Understanding of information' questions in the participant survey results analysis by question. The response rate was above average.

A comparison of ventilation effects using bag-valve-mask assist device (백-밸브-마스크 보조장치를 이용한 환기효과 비교)

  • EunYoung, Seo;ByoungGil, Yoon;GaEun, Kim;YougSeok, Kim
    • The Korean Journal of Emergency Medical Services
    • /
    • v.26 no.3
    • /
    • pp.37-46
    • /
    • 2022
  • Purpose: TThe experiment was designed to compare the efficiency of ventilation between conventional BVM ventilation and a newly devised A-BVM ventilation method with Tidal volume, total ventilation rate, average Ventilation speed, and average Ventilation volume. Methods: 40 Paramedical students who agreed to participate in the study were analyzed. Values were measured using IMB PASS after 2 minutes of Brayden Pro manikin with BVM and A-BVM ventilation. The difference in general characteristics was assessed by t-test and ANOVA and the difference in ventilation methods was analyzed by IBM SPSS. Results: A significant difference was found between the two ventilation methods in terms of tidal volume (t=-11.203, p<.001), ventilation time (t=-3.834, p<.001), and optimum ventilation probability (t=10.770, p<.001). A-BVM ventilation method, rather than BVM ventilation method, showed a value close to the appropriate amount recommended by Korean Advanced Life Support (500~600mL) in tidal volume, and higher in optimum ventilation probability. Conclusion: We could identify the a better mode of ventilation. Further studies on the efficacy of existing BVM ventilation methods as compared to device augmented BVM ventilation methods should be carried out to ensure that adequate ventilation is available to patients in clinical practice.

Blood Compatibility of Hollow Fiber Membranes Treated by Plasma Polymerization (플라즈마 중합 처리된 중공사 막의 혈액 적합성)

  • Lee, Sam-Cheol;Kwon, O-Sung
    • Membrane Journal
    • /
    • v.15 no.3
    • /
    • pp.233-240
    • /
    • 2005
  • Surface modification of polypropylene hollow fiber membranes was performed in order to develop blood-compatibility biomaterials for use in the blood contacting surfaces and oxygenation membranes of a lung assist device (LAD), important medical device even more useful. Blood compatibility of materials was determined by using anticoagulation blood and evaluating formation of blood clots on their surfaces as well as activation of plasma coagulation cascade, platelet adhesion, and aggregation. It was verified that the number of platelets on the silicone coated fibers was significantly lower than that on untreated fiber membrane, indicating improved blood compatibility. It was also found that the polypropylene hollow fiber membranes using plasma treatment exhibited suppression of complement activation in blood compatibility test.

Development of Head Mounted Display Interface System for Controlling Wireless Capsule Endoscope (무선 캡슐내시경 조종을 위한 머리부착형 디스플레이 인터페이스 시스템의 개발)

  • Young-Eun, Hwang;Young-Don, Son
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.417-423
    • /
    • 2022
  • The present study proposed a new interface system for capsule endoscopy by using head mounted display (HMD) device, which can control the orientation of the capsule endoscope with electromagnetic actuator (EMA) system. The orientation information of the HMD user was detected by the gyroscope sensor built into the device and then calculated to as an angle increment using Unity Engine compiler. The measured angle changes from the HMD were converted to the current values of the corresponding coils to be changed in the EMA system. Two experiments were designed to measure the accuracy and the intuitiveness of the HMD interface system. In the angle accuracy measurement, the capsule endoscope driven by HMD interface system showed the averaged errors of 0.68 degrees horizontally and 1.001 degrees vertically for given test angles. In the intuitiveness measurement, HMD interface system showed 1.33 times faster manipulation speed rather than the joystick interface system. In this respect, the HMD interface system for capsule endoscopy was expected to improve the overall diagnostic environment while maintaining comfort of patients and clinicians.

Comparison of changes in ventilation volume according to fixation method of I-gel during cardiopulmonary resuscitation: a study using a simulated manikin (심폐소생술 시 아이젤의 고정 방법에 따른 환기량의 변화 비교: 시뮬레이션 마네킨을 이용한 연구)

  • Kim, Seon Tae;Shin, Sang-Yol;Choi, Jeong Woo
    • The Korean Journal of Emergency Medical Services
    • /
    • v.25 no.3
    • /
    • pp.7-16
    • /
    • 2021
  • Purpose: The I-gel device is Korea's most frequently used airway management method during pre-hospital cardiopulmonary resuscitation (CPR). This study aimed to compare changes in ventilation volume according to the fixation method with a simulated manikin. Methods: We placed I-gel into an advanced life support simulator and compared tape and band fixation conditions. CPR was performed according to the 2020 Korean CPR guidelines, using a mechanical chest compression device and an adult bag. The positional shift of I-gel and the ventilation volume of the simulated manikin were measured after performing CPR for 20 minutes. Five trials were carried out in each setting. Statistical analysis was carried out with SPSS 27.0. P < .05 was considered significant. Results: Positional shift after 20 minutes of CPR was as follows: tape fixation, 7.2 ± 0.2 mm; band fixation, no change, indicating a significant difference between the two groups (p=.003). The mean ventilation volume was tape fixation, 482.63 ± 30.84 mL; band fixation, 544.96 ± 22.98 mL, showing a significant difference (p=.002). Conclusion: When using the I-gel during pre-hospital CPR, using a band-type fixing device with elasticity rather than fixing the tape provides stable and appropriate ventilation by maintaining the fixed position.