• 제목/요약/키워드: Advanced imaging techniques

검색결과 102건 처리시간 0.034초

Usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases

  • Ogura, Ichiro;Nakahara, Ken;Sasaki, Yoshihiko;Sue, Mikiko;Oda, Takaaki
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.161-165
    • /
    • 2018
  • Purpose: To evaluate the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Materials and Methods: Ten patients with oral and maxillofacial diseases and 28 volunteers drawn from our student doctors were examined by shear wave elastography with a 14-MHz linear transducer using an Aplio 300 apparatus (Canon Medical Systems, Otawara, Japan). A statistical analysis of the shear elastic modulus(kPa) of healthy tissue (the sublingual gland, submandibular gland, anterior belly of the digastric muscle, and geniohyoid muscle) in the 28 volunteers was performed using 1-way repeated measures analysis of variance with the Tukey honest significant difference test. The maximum shear elastic modulus(kPa) of 8 patients with squamous cell carcinoma (SCC) and 2 patients with benign lesions was evaluated with the Mann-Whitney U test. The analysis used a 5% significance level. Results: The mean shear elastic modulus of the sublingual gland ($9.4{\pm}3.7kPa$) was lower than that of the geniohyoid muscle ($19.2{\pm}9.2kPa$, P=.000) and the anterior belly of the digastric muscle ($15.3{\pm}6.1kPa$, P=.004). The maximum shear elastic modulus of the SCCs($109.6{\pm}14.4kPa$) was higher than that of the benign lesions($46.4{\pm}26.8kPa$, P=.044). Conclusion: Our results demonstrated the usefulness of shear wave elastography in the diagnosis of oral and maxillofacial diseases. Shear wave elastography has the potential to be an effective technique for the objective and quantitative diagnosis of oral and maxillofacial diseases.

방사선치료를 위한 영상장비의 선량 및 영상 평가 (Dose and Image Evaluations of Imaging for Radiotherapy)

  • 이형건;윤창연;김태준;김동욱;정원규;박성호;이원호
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.292-302
    • /
    • 2012
  • 최근 방사선치료 분야에 있어서 환자 선량이 중요한 쟁점이 되고 있다. 선량 감소를 위해 선진 기술을 이용한 방사선치료 시 사용하는 진단영상 장비에 대한 평가가 이루어져야 한다. 특히 CT는 방사선치료 분야에서 널리 사용되는 영상 장비이며, 본 연구에서는 CT의 선량과 영상에 대한 평가를 실시하였다. 선량과 영상을 동시에 비교할 수 있도록 동일한 조건 하에서 평가를 실시하였다. 또한 몬테카를로 시뮬레이션 툴인 MCNPX를 이용한 선량과 영상 평가가 가능하다는 것을 확인하였다. 저 선량 CT 영상의 질을 향상시키기 위하여 MLEM기법을 이용한 반복적 영상재구성 기법을 구축하였다. 본 연구의 평가 방법을 통해 방사선 치료 분야에서의 환자 선량을 줄이는 것뿐만 아니라 산업 연구 분야에서의 영상장비들의 총체적인 평가가 가능할 것이다.

워터마킹 영상의 비가시성 개선에 관한 연구 (A Study on Invisibility Improvement of Watermarking Image)

  • 김형균;이양원
    • 한국항행학회논문지
    • /
    • 제11권3호
    • /
    • pp.329-336
    • /
    • 2007
  • 최근 몇 년 동안 인터넷을 기반으로 한 디지털 영상 기술과 디지털 콘텐츠의 사용이 빠르게 증가하고 있어서 디지털 영상 보호에 대한 요구가 더욱 중요시되고 있다. 디지털 이미지의 저작권 보호를 위해, 콘텐츠 인증, 소유권 인증, 불법 복제등과 같은 인증 기술의 검증이 필요하다. 영상에 디지털 워터마크를 삽입하는 비가시적 부호화 기술인 디지털 워터마킹은 정교한 인지 정보를 워터마킹 과정에 영상의 투명도와 강건함을 제공하기 위해 사용되어야 한다. 본 논문에서는 시각 특성을 이용한 주파수 영역에서 DWT 변환을 이용해 위조 공격, 소유권 보호 및 인증 방지를 위한 디지털 워터마킹 알고리즘을 구현하고자 한다.

  • PDF

Brain Metastases from Solid Tumors: an Institutional Study from South India

  • Ghosh, Saptarshi;Rao, Pamidimukkala Brahmananda
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권13호
    • /
    • pp.5401-5406
    • /
    • 2015
  • Background: Brain metastases are the most common intra-cranial neoplasms. The incidence is on a rise due to advanced imaging techniques. Aims: The objective of the study was to analyse the clinical and demographic profile of patients with brain metastases from primary solid tumors. Materials and Methods: This is a retrospective single institutional study covering 130 consecutive patients with brain metastases from January 2007 to August 2014. Results: Some 64.6% of the patients were females. The majority were in the sixth decade of life. The site of the primary tumor was the lungs in 50.8% of the cases. The overall median time from the diagnosis of the primary malignancy to detection of brain metastases was 21.4 months. Survival was found to be significantly improved in patients with solitary brain lesions when compared to patients with multiple brain metastases, and in patients undergoing surgical excision with or without cranial irradiation when compared to whole brain irradiation alone. The majority of the cases belonged to the recursive partitioning analysis class II group. Whole brain radiation therapy was delivered to 79% of the patients. Conclusions: Most of the patients with brain metastases in the study belonged to recursive partitioning analysis classes II or III, and hence had poor prognosis. Most of the patients in the Indian context either do not satisfy the indications for surgical excision or are incapable of bearing the high cost associated with stereotactic radiosurgery. Treatment should be tailored on an individual basis to all these patients.

고액공존 과공정 Al-Si합금의 교반응고시 미세조직변화 (Microstructural changes during semi-solid state processing of hypereutectic Al-Si alloys)

  • 유영호;김도향
    • 한국주조공학회지
    • /
    • 제15권5호
    • /
    • pp.483-493
    • /
    • 1995
  • The microstructural changes during semi-solid state processing of hypereutectic Al-Si alloy has been investigated in the present study. Stirring of semi-solid slurry results in the morphological changes of the primary Si particles, i.e. from angular rod shape to near-spherical shape. Besides the spherodization of primary Si particles, the average particle size increases, especially, at much higher rate in the final stage than that in the early stage of stirring. Various microstructure characterization techniques, such as anisotropic etching, SEM imaging and ECP analysis, reveal that the spherodization of primary Si particles occurs by the combinations of the mechanisms of coalescence, fracture, and wear of the individual particles. Isothermal shearing of hypereutectic Al-Si at $580^{\circ}C$ shows that spherical ${\alpha}-Al$ particles are formed by the dissociation of Al-Si eutectic structure at the early stage of isothermal shearing. The spherical ${\alpha}-Al$ particles gradually grow by the mechanisms of Ostwald ripening and coalescence of the particles.

  • PDF

HIFU: 현황 및 기술적 동향 (High Intensity Focused Ultrasound for Cancer Treatment: Current Agenda and the Latest Technology Trends)

  • 서종범
    • The Journal of the Acoustical Society of Korea
    • /
    • 제29권2E호
    • /
    • pp.55-63
    • /
    • 2010
  • High Intensity Focused Ultrasound (HIFU) is a noninvasive surgical method mainly targeting deeply located cancer tissue. Ultrasound is generated from an extemally located transducer and the beam is focused at the target volume, so that selective damage can be achieved without harm to overlying or surrounding tissues. The mechanism for cell killing can be combination of thermal and cavitational damage. Although cavitation can be an effective means of tissue destruction, the possibility of massive hemorrhage and the unpredictable nature of cavitational events prevent clinical application of cavitation. Hence, thermal damage has been a main focus related to HIFU research. 2D phased array transducer systems allow electronic scanning of focus, multi-foci, and anti-focus with multi-foci, so that HIFU becomes more applicable in clinical use. Currently, lack of noninvasive monitoring means of HIFU is the main factor to limit clinical applications, but development in MRI and Ultrasound Imaging techniques may be able to provide solutions to overcome this problem. With the development of advanced focusing algorithm and monitoring means, complete noninvasive surgery is expected to be implemented in the near future.

Application of Autofluorescence for Confocal Microscopy to Aid in Archaeoparasitological Analyses

  • Morrow, Johnica Jo;Elowsky, Christian
    • Parasites, Hosts and Diseases
    • /
    • 제57권6호
    • /
    • pp.581-585
    • /
    • 2019
  • Confocal laser scanning microscopy (CLSM) was used to examine archaeoparasitological specimens from coprolites associated with La Cueva de los Muertos Chiquitos (CMC) located near present-day Durango, Mexico. The eggs for 4 different types of parasites recovered from CMC coprolites were imaged using CLSM to assist with identification efforts. While some of the parasite eggs recovered from CMC coprolites were readily identified using standard light microscopy (LM), CLSM provided useful data for more challenging identifications by highlighting subtle morphological features and enhancing visualization of parasite egg anatomy. While other advanced microscopy techniques, such as scanning electron microscopy (SEM), may also detect cryptic identifying characters, CLSM is less destructive to the specimens. Utilizing CLSM allows for subsequent examinations, such as molecular analyses, that cannot be performed following SEM sample preparation and imaging. Furthermore, CLSM detects intrinsic autofluorescence molecules, making improved identification independent of resource and time-intensive protocols. These aspects of CLSM make it an excellent method for assisting in taxonomic identification and for acquiring more detailed images of archaeoparasitological specimens.

다층구조 엑스선 검출기를 이용한 이중에너지 조영제 영상의 물질 구분에 관한 연구 (A Study on the Material Decomposition of Dual-Energy Iodine Image by Using the Multilayer X-ray Detector)

  • 김준우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.465-471
    • /
    • 2021
  • Dual-energy X-ray imaging (DEI) techniques can provide X-ray images that a certain material is suppressed or emphasized by combining two X-ray images obtained from two different x-ray spectrum. In this paper, a single-shot DEI, which uses stacked two detectors (i.e., multilayer detector), is proposed to reduce the patient dose and increase throughput in angiography. The polymethyl methacrylate (PMMA) and aluminum (Al) were selected as two basis materials for material decomposition, and material-specific images are reconstructed as a vector combination of these two materials. We investigate the contrast and noise performance of material-decomposed images using iodine phantoms with various concentrations and diameters. The single-shot DEI shows comparable performances to the conventional dual-shot DEI. In particular, the single-shot DEI shows edge enhancement in material-decomposed images due to the different spatial-resolution characteristics of upper and lower detectors. This study could be useful for designing the multilayer detector including scintillators and energy-separation filter for angiography purposes.

Stochastic nature of magnetic processes studied by full-field soft X-ray microscopy

  • Im, Mi-Young
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1174-1181
    • /
    • 2018
  • In nanomagnetism, one of the crucial scientific questions is whether magnetic behaviors are deterministic or stochastic on a nanoscale. Apart from the exciting physical issue, this question is also of paramount highest relevance for using magnetic materials in a wealth of technological applications such as magnetic storage and sensor devices. In the past, the research on the stochasticity of a magnetic process has been mainly done by macroscopic measurements, which only offer ensemble-averaged information. To give more accurate answer for the question and to fully understand related underlying physics, the direct observation of statistical behaviors in magnetic structures and magnetic phenomena utilizing advanced characterization techniques is highly required. One of the ideal tools for such study is a full-field soft X-ray microscope since it enables imaging of magnetic structures on the large field of view within a few seconds. Here we review the stochastic behaviors of various magnetic processes including magnetization reversal process in thin films, magnetic domain wall motions in nanowires, and magnetic vortex formations in nanodisks studied by full-field soft X-ray microscopy. The origin triggering the stochastic nature witnessed in each magnetic process and the way to control the intrinsic nature are also discussed.

고압 인젝터의 분사율 예측을 위한 경량 모델 개발 (Development of a Lightweight Prediction Model of Fuel Injection Rates from High Pressure Fuel Injectors)

  • 이상권;배규한;;문석수;강진석
    • 한국분무공학회지
    • /
    • 제25권4호
    • /
    • pp.188-195
    • /
    • 2020
  • To meet stringent emission regulations of automotive engines, fuel injection control techniques have advanced based on reliable and fast computing prediction models. This study aims to develop a reliable lightweight prediction model of fuel injection rates using a small number of input parameters and based on simple fluid dynamic theories. The prediction model uses the geometry of the injector nozzle, needle motion data, injection conditions and the fuel properties. A commercial diesel injector and US No. 2 diesel were used as the test injector and fuel, respectively. The needle motion data were measured using X-ray phase-contrast imaging technique under various fuel injection pressures and injection pulse durations. The actual injector rate profiles were measured using an injection rate meter for the validation of the model prediction results. In the case of long injection durations with the steady-state operation, the model prediction results showed over 99 % consistency with the measurement results. However, in the case of short injection cases with the transient operation, the prediction model overestimated the injection rate that needs to be further improved.