• 제목/요약/키워드: Advanced imaging techniques

검색결과 102건 처리시간 0.03초

Mandibular lateral incisor with four root canals: A unique case of double tooth diagnosed using multidetector computed tomography

  • Gupta, Sunil Kumar;Gupta, Jaya;Acharya, Shashi Rashmi;Ather, Amber
    • Imaging Science in Dentistry
    • /
    • 제43권2호
    • /
    • pp.123-128
    • /
    • 2013
  • Double tooth is a dental anomaly consequent to fusion of two or more teeth or gemination of a single tooth. This report describes a unique case of double tooth in relation to a mandibular lateral incisor exhibiting the presence of four root canals. The role of conventional radiography and advanced three-dimensional imaging techniques in the better assessment of complex root canal systems and their aid in endodontic management has also been highlighted.

Multimodal neuroimaging in presurgical evaluation of childhood epilepsy

  • Jung, Da-Eun;Lee, Joon-Soo
    • Clinical and Experimental Pediatrics
    • /
    • 제53권8호
    • /
    • pp.779-785
    • /
    • 2010
  • In pre-surgical evaluation of pediatric epilepsy, the combined use of multiple imaging modalities for precise localization of the epileptogenic focus is a worthwhile endeavor. Advanced neuroimaging by high field Magnetic resonance imaging (MRI), diffusion tensor images, and MR spectroscopy have the potential to identify subtle lesions. $^{18}F$-FDG positron emission tomography and single photon emission tomography provide visualization of metabolic alterations of the brain in the ictal and interictal states. These techniques may have localizing value for patients which exhibit normal MRI scans. Functional MRI is helpful for non-invasively identifying areas of eloquent cortex. These advances are improving our ability to noninvasively detect epileptogenic foci which have gone undetected in the past and whose accurate localization is crucial for a favorable outcome following surgical resection.

단일 카메라를 이용한 보행자의 높이 및 위치 추정 기법 (Estimation of Human Height and Position using a Single Camera)

  • 이석한;최종수
    • 전자공학회논문지SC
    • /
    • 제45권3호
    • /
    • pp.20-31
    • /
    • 2008
  • 본 논문에서는 단일 카메라를 이용하여 영상 내에 존재하는 객체의 3차원 공간 상에서의 위치 및 높이를 추출하기 위한 기법을 제안한다. 본 논문에서 제안하는 방법은 영상으로 사영된 3차원 장면(scene)에 대한 기준 좌표계를 마커(marker)를 이용해서 설정한 다음, 대상 물체의 2차원 영상을 기준 좌표계로 직접 역사영(back-projection) 시킴으로써 대상 물체에 대한 3차원 공간에서의 위치 및 높이를 계산한다. 그리고 부정확한 카메라 교정으로 인하여 발생하는 역사영 오차를 마커의 기하학 정보를 이용해서 보정한다. 제안된 방법은 기존의 방법에서 주로 이용되던 소실점(vanishing point) 및 소실선(vanishing line) 등을 이용하지 않으며, 3차원 공간 내에서의 객체의 높이 및 위치의 동시 추정이 가능한 장점이 있다. 또한 단일 카메라만을 이용하여 필요한 위치 및 높이 정보를 추출하기 때문에 다중 카메라를 이용한 기법에서 발생할 수 있는 3차원 좌표계 상에서의 대응점의 모호성, 다수의 카메라를 정확히 교정시켜야 하는 어려움 등의 문제가 발생하지 않는다. 실험 결과를 통하여 제안된 기법의 정확도 및 안정성을 확인하였다.

다기능 NSOM (mf-NSOM) 을 이용한 나노 구조 재료 분석에 관한 원리와 응용 (Fundamentals and Applications of Multi-functional NSOM Technology to Characterization of Nano Structured Materials)

  • 이우진;변수일
    • 전기화학회지
    • /
    • 제7권2호
    • /
    • pp.108-123
    • /
    • 2004
  • 최근 근접장 광학주사현미경 (NSOM)을 이용한 재료의 표면 및 구조 분석은 생물학에서 재료과학에까지 광범위하게 응용되고 있다. 본 총설에서는 기존의 NSOM을 여러가지 현미경법 (광학, 형광, 전자 및 전기화학 현미경 관찰법)과 접목하여 구성한 다기능 NSOM (multi-functional NSOM, mf-NSOM)을 이용, 나노 재료의 고분해능 이미징에 대한 원리와 응용을 고찰하였다. 본 mf-NSOM 기술을 이용하여 실제로 Al합금 및 다결정 Ti 표면에서의 공식 (pitting)을 일으키는 취약 지역을 광학적으로 분석한 결과를 기술하였다. 또한, mf-NSOM과 레이저 기술을 통해 나노 Ag 입자를 형성하고 실시간 분석한 연구결과에 대해서도 소개하고자 한다.

VR, AR 시뮬레이션 및 3D Printing을 활용한 어깨와 팔꿈치 수술실습 (VR, AR Simulation and 3D Printing for Shoulder and Elbow Practice)

  • 임원봉;문영래
    • 전자공학회논문지
    • /
    • 제53권12호
    • /
    • pp.175-179
    • /
    • 2016
  • 최근 의료 영상 기술의 발전은 진단, 수술계획, 또는 교육에 도움이 되는 수술 시뮬레이션을 만들어 왔다. 개선된 고화질 영상과 3차원 시각화는 의료 영상 가용성을 향상시키고 수술, 교육 분야에서 더 잘 이용할 수 있게 되었다. 실제 인간의 시각은 입체이다. 따라서, 외과의사의 판단을 통해 2차원 영상을 스테레오로 재구성하여 처리하는 것이 함께 필요하다. 이러한 과정을 줄이기 위해, 3차원 (3D) 이미지가 사용되어 왔다. 3D 영상은 복잡한 상황에서 외과 의사가 매우 짧은 시간에 판단할 수 있도록 3D 시각화를 강화하여 제공한다. 3D 화상 데이터 세트에 기초하여, 가상 내시경 수술 계획, 실시간 상호 작용 가상 의료 시뮬레이션이 가능하게 되었다. 본 논문은 새로운 이미징 기술의 최근 응용 프로그램을 설명하고 이의 기본과 특별히 주목할만한 의료 3D 복원 기술에 관한 것이다. 최근 CT, MR 및 기타 영상 양식의 기술발전은 흥미로운 새로운 솔루션과 어깨 영상의 활용 가능성을 넓혀왔다. 특히, 의료 기기에서 파생 된 3차원 (3D) 이미지는 고급 정보를 제공한다. 이 프레젠테이션은 어깨와 팔꿈치의 수술실습에서 원리, 3D 영상기술의 잠재적 응용가능성, 시뮬레이션, 3D프린팅을 설명한다.

Advanced Cryo-Electron Microscopy Technology: High Resolution Structure of Macromolecules

  • Chung, Jeong Min;Jung, Hyun Suk
    • Applied Microscopy
    • /
    • 제46권1호
    • /
    • pp.1-5
    • /
    • 2016
  • Recent cryo-electron microscopy (EM) studies reported the structure of various types of proteins at high resolution which is sufficient to visualize the intermolecular interaction at near atomic level. There are two main factors that cause the advances in cryo-EM; the development of image processing techniques, such as single particle analysis, and the improved electron detection devices. Although the atomic structures of small and asymmetric proteins are not yet to be determined by cryo-EM, this striking improvement implies the bright prospect of the application in biomedical studies. This study reviews the recently published studies reported high resolution structures using improved imaging analysis techniques and electron detectors. Furthermore, we will discuss about the future aspects of cryo-EM application.

Design and Manufacture of an Off-axis Aluminum Mirror for Visible-light Imaging

  • Zhang, Jizhen;Zhang, Xin;Tan, Shuanglong;Xie, Xiaolin
    • Current Optics and Photonics
    • /
    • 제1권4호
    • /
    • pp.364-371
    • /
    • 2017
  • Compared to one made of glass, an aluminum mirror features light weight, compact design, low cost, and quick manufacturing. Reflective mirrors and supporting structures can be made from the same material, to improve the athermal performance of the system. With the rapid development of ultraprecise machining technologies, the field of applications for aluminum mirrors has been developed rapidly. However, most of them are rotationally symmetric in shape, and are used for infrared applications. In this paper, the design and manufacture of an off-axis aluminum mirror used for a three-mirror-anastigmat (TMA) optical system at visible wavelengths is presented. An optimized, lightweight design provides a weight reduction of more than 40%, while the surface deformation caused by earth's gravity can meet the required tolerance. The two pieces of an off-axis mirror can be diamond-turned simultaneously in one setup. The centrifugal deformation of the off-axis mirror during single-point diamond turning (SPDT) is simulated through the finite-element method (FEM). The techniques used to overcome centrifugal deformation are thoroughly described in this paper, and the surface error is reduced to about 1% of the original value. After post-polishing, the form error is $1/30{\lambda}$ RMS and the surface roughness is better than 5 nm Ra, which can meet the requirements for visible-light imaging.

Bridge Inspection and condition assessment using Unmanned Aerial Vehicles (UAVs): Major challenges and solutions from a practical perspective

  • Jung, Hyung-Jo;Lee, Jin-Hwan;Yoon, Sungsik;Kim, In-Ho
    • Smart Structures and Systems
    • /
    • 제24권5호
    • /
    • pp.669-681
    • /
    • 2019
  • Bridge collapses may deliver a huge impact on our society in a very negative way. Out of many reasons why bridges collapse, poor maintenance is becoming a main contributing factor to many recent collapses. Furthermore, the aging of bridges is able to make the situation much worse. In order to prevent this unwanted event, it is indispensable to conduct continuous bridge monitoring and timely maintenance. Visual inspection is the most widely used method, but it is heavily dependent on the experience of the inspectors. It is also time-consuming, labor-intensive, costly, disruptive, and even unsafe for the inspectors. In order to address its limitations, in recent years increasing interests have been paid to the use of unmanned aerial vehicles (UAVs), which is expected to make the inspection process safer, faster and more cost-effective. In addition, it can cover the area where it is too hard to reach by inspectors. However, this strategy is still in a primitive stage because there are many things to be addressed for real implementation. In this paper, a typical procedure of bridge inspection using UAVs consisting of three phases (i.e., pre-inspection, inspection, and post-inspection phases) and the detailed tasks by phase are described. Also, three major challenges, which are related to a UAV's flight, image data acquisition, and damage identification, respectively, are identified from a practical perspective (e.g., localization of a UAV under the bridge, high-quality image capture, etc.) and their possible solutions are discussed by examining recently developed or currently developing techniques such as the graph-based localization algorithm, and the image quality assessment and enhancement strategy. In particular, deep learning based algorithms such as R-CNN and Mask R-CNN for classifying, localizing and quantifying several damage types (e.g., cracks, corrosion, spalling, efflorescence, etc.) in an automatic manner are discussed. This strategy is based on a huge amount of image data obtained from unmanned inspection equipment consisting of the UAV and imaging devices (vision and IR cameras).

소 동물 1H 1.5 T 자기공명영상 장치용 유연인쇄기판 기반 새장형 수신 코일 센서 (FPCB-based Birdcage-Type Receiving Coil Sensor for Small Animal 1H 1.5 T Magnetic Resonance Imaging System)

  • 세이크 파이잘 아마드;김현덕
    • 센서학회지
    • /
    • 제26권4호
    • /
    • pp.245-250
    • /
    • 2017
  • A novel method to implement a birdcage-type receiving coil sensor for use in a magnetic resonance imaging(MRI) system has been demonstrated employing a flexible printed circuit board (FPCB) fabrication technique. Unlike the conventional methods, the two-dimensional shape of the coil sensor is first implemented as a FPCB and then it is attached to the surface of a cylindrical supporting structure to implement the three-dimensional birdcage-type coil sensor. The proposed method is very effective to implement object-specific MRI coil sensors especially for small animal measurements in research and preclinical applications since the existing well-developed FPCB-based techniques can easily meet the requirements on accuracies and costs during coil implement process. The performances of the coil sensor verified through $^1H$ 1.5T MRI measurements for small animals and it showed excellent characteristics by providing a high spatial precision and a high signal-to-noise ratio.

3차원 디지탈 내시경 영상의 임상적 효용성 평가 (Evaluation of Clinical Effectiveness of 3D Digital Endoscopic Image)

  • 송철규;김경섭;김남균
    • 대한디지털의료영상학회논문지
    • /
    • 제5권1호
    • /
    • pp.26-31
    • /
    • 2002
  • 본 연구의 목적은 복강경 수술환경에서 2D와 3D 내시경 비디오 영상이 수술에 미치는 영향을 평가하기 위한 연구이며, 이를 위해 3D 내시경 시스템을 구성하고 성능 평가를 수행하였다. 결과적으로 본 연구에서 제안한 3D 방식이 기존의 전자셔터 방식에 의한 3D 영상에 비해 화질과 시야각이 우수하며, 2종류의 모의 수술 실험 비교를 한 결과, 제안한 방식의 디지털 영상을 이용하는 경우가 성능이 가장 우수함을 정량적으로 확인하였다.

  • PDF