• Title/Summary/Keyword: Advanced Water Treatment Process

Search Result 339, Processing Time 0.132 seconds

수정 RABC 공정을 이용한 영양염류 제거능 제고에 관한 연구 (Nutrients removal enhancement using a modified rotating activated bacillus contactor (RABC) process)

  • 김선희;김동환;장기웅;김응호
    • 상하수도학회지
    • /
    • 제30권1호
    • /
    • pp.99-104
    • /
    • 2016
  • This study was performed to develop a new process technology for advanced wastewater treatment using a modified Rotating Activated Bacillus Contactor (RABC) process that adopts anoxic-oxic suspended biomass tanks to enhance nutrients removal. A modified lab-scale RABC process was applied to examine its applicability and to obtain the design factors for the optimum operation of the system. The modified RABC process showed a little more stable and high nutrients removal efficiency than the prototype RABC process: about 70% of nitrogen and 55% of phosphorous removal when the low organic loading (influent COD 200mg/L). However, the processing efficiency of nutrients removal rates was enhanced to great extent when high organic loading: nitrogen 90% and phosphorous 85% (influent COD 500mg/L). High organic loading stimulated extremely good biomass attachment on the reticular carrier RABC stage and the excellent nutrients removal, nevertheless with almost no offensive odor.

Effect of Thermal Treatment Temperature on Lifespan of Conductive Oxide Electrode

  • Yoo, Y.R.;Chang, H.Y.;Jang, S.G.;Nam, H.S.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • 제6권2호
    • /
    • pp.44-49
    • /
    • 2007
  • Dimensionally stable anodes have been widely used to cathodically protect the metallic materials in corrosive environments including concrete structure as the insoluble anode. Lifespan of the anode for concrete construction can be determined by NACE TM0294-94 method. Lifespan of conductive oxide electrode would be affected by thermal treatment condition in the process of sol-gel coatings. This work aims to evaluate the effect of thermal treatment temperature on the lifespan of the $RuO_{2}$ electrode. $450^{\circ}C$ treated conductive oxide electrode showed the excellent properties and its lifespan was evaluated to be over 88 years in 3% NaCl, 4% NaOH, and simulated pore water. This behavior was related to the formation of $RuO_{2}$.

Which CDM methodology is the best option? A case study of CDM business on S-Water treatment plant

  • Kyung, Daeseung;Lee, Woojin
    • Advances in environmental research
    • /
    • 제1권2호
    • /
    • pp.125-142
    • /
    • 2012
  • Clean development mechanism (CDM) validity study was conducted to suggest better and more adaptable CDM scenario on water treatment plant (WTP). Potential four scenarios for CDM project; improvement of intake pumping efficiency, hydro power plant construction, solar panel construction and system optimization of mechanical mixing process were evaluated on S-WTP in Korea. Net present value (NPV) of each scenario was estimated based on sensitivity analysis with the variable factors to investigate the CDM validity percentile. Hydro power plant construction was the best option for CDM business with 97.76% validity and $1,127,069 mean profit by 9,813 $tonsCO_2e$/yr reduction. CDM validity on improvement of intake pumping efficiency was 90.2% with $124,305 mean profit by huge amount of $CO_2$ mitigation (10,347 $tonsCO_2e$/yr). System optimization of mechanical mixing process reduced 15% of energy consumption (3,184 $tonsCO_2e$/yr) and its CDM validity and mean profit was 77.25% and $23,942, respectively. Solar panel construction could make the effect of 14,094 $tonsCO_2$ mitigation annually and its CDM validity and mean profit was 64.68% and $228,487, respectively.

정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구 (A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process)

  • 국영롱;주재영;배윤선;이혜인;정인호;박철휘
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.595-601
    • /
    • 2010
  • It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.

수정된 MLE 공정을 이용한 Full-Scale에서의 돈사분뇨처리 (Piggery Waste Treatment using Improved MLE Process in Full-Scale)

  • 황인수;민경석
    • 한국물환경학회지
    • /
    • 제22권5호
    • /
    • pp.895-904
    • /
    • 2006
  • The improved MLE (modified Ludzack-Ettinger) process was operated for piggery waste treatment in full-scale public livestock waste treatment plant. The treated waste from bioreactor was suitable for the strict effluent standard of 200 mgCOD/L and 60 mgTN/L as it was dewatered chemically without settling tank and passed through filtration process. Though this treatment method produced a great deal of sludge ($6.4m^3\;per\;m^3$ dewatered piggery waste) it was able to accomplish predominant effluent quality by removing non-biodegradable COD and color without advanced oxidation process as ozone, fenton and etc.. The nitrogen removal efficiency of bioreactor was rapidly declined from March to May (from 0.016 to 0.005 kgN/kgVSS-day) when disinfection is in earnest as well as from warm season when reactor temperature rises higher than $35^{\circ}C$(from 0.016 to 0.008 kgN/kgVSS-day). This study proves that counterplanes for infection residuals, bioreactor temperature and dewatering sludge reduction are necessary for piggery waste treatment.

수열처리에 의한 폐병유리의 다공질 재료화 (Porous Materials from Waste Bottle Glasses by Hydrothermal Treatment)

  • 임동규;강은태
    • 한국세라믹학회지
    • /
    • 제46권3호
    • /
    • pp.275-281
    • /
    • 2009
  • Porous materials were manufactured by hydrothermal treatment of waste bottle glass without foam agent. Factorial design was applied to analyze data by statistical methods and deal with the important factors for a process. The largest effect for porosity was for temperature of hydrothermal treatment. Amount of water and temperature-water interaction appeared to have little effect. The particle size of raw material was also identified as a major factor by one-way ANOVA and the porosity decreased as the size increased. The sintering temperature was not statistically significant for the porosity but was significant for the pore size. The porous material had compressive strength and thermal conductivity comparing with those of ALC (autoclaved lightweight concrete), although it has higher porosity than for ALC.

제지폐수의 COD 저감 및 처리공정 최적화에 관한 연구 (COD Reduction and Process Optimization of Waste Water from the Paper-mill)

  • 신동호;이용택
    • 공업화학
    • /
    • 제16권5호
    • /
    • pp.693-697
    • /
    • 2005
  • 제지산업에서 COD 부하 및 난분해성 COD 부하가 높은 생산지종별 발생폐수의 처리방안을 통하여 단위공정의 최적화와 방류수의 수질 안정화에 대해 연구하였다. 그 결과 1차 처리 공정에서는 SS와 더불어 colloid성 물질제거를 통한 COD 제거효율을 향상시키기 위해서 음이온 응집제 및 Alum의 병행사용이 효과적인 것으로 분석되었다. 또한 Fenton 산화법의 병행사용으로 인한 약품의 과량투입은 수질상태에 악영향을 주는 것으로 확인되었기 때문에 최적량인 $FeCl_2$$H_2O_2$의 비가 1:1인 농도비 1000 ppm 일 때 COD 제거율이 가장 높다고 판단된다.

초순수 생산을 위한 최적공정 조합 평가 (A Study of the Optimization Process Combination on the Ultrapure Water Treatment System)

  • 이경혁;김동규;권병수;정관수
    • 대한환경공학회지
    • /
    • 제38권7호
    • /
    • pp.364-370
    • /
    • 2016
  • 본 연구에서는 초순수 생산을 위한 개별공정들의 특성을 고려하여 공정조합 최적화 방안을 결정하는 기법을 연구하였다. 산업 활동에 사용하는 공업용수 중 고도의 기술집합 산업에서 요구되는 고순도 용수인 초순수를 생산하는 공정은 여과, 이온교환, 역삼투, 탈기, 자외선 산화 등 이 있다. 초순수 공정은 다양한 15~20개 정도의 수처리 단위 공정이 조합을 이루고 있다. 본 연구에서는 초순수 생산 모형플랜트를 운영하여 다양한 처리 공정의 조합을 통해 수질 및 경제성을 고려하여 평가하였다. 평가된 19종류의 공정조합 중 11개 공정조합이 목표로 하는 최종 수질을 만족했다. 이러한 11종의 공정조합에 대해 안정성과 경제성을 평가하였다.

역세척수 회수시스템이 포함된 배출수처리공정의 설계 (Design of Residual Treatment Process with Filter Backwash Recycle System)

  • 배병욱;최경환
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.109-114
    • /
    • 2012
  • In this study, both sedimentation and thickening experiments were conducted for residuals produced from an advanced water treatment plant for more accurate and practical design of residual treatment train. In order to design a backwashed residual sedimentation basin (SRSB) in the filter backwash water recycle system, two kinds of backwash waters, one from sand filter (SFBW) and the other from GAC adsorption bed (GACBW), were separately collected and their surface loading rate measured. In addition, in order to design a gravity thickener, batch thickening tests were conducted for concentrated residuals taken from sedimentation basin and their limiting solid flux ($SF_{L}$) measured. From the experimental results and consideration of the seasonal characteristics of the residual, surface loading rate of $70m^{3}/m^{2}{\cdot}d$ was proposed as a design parameter for SRSB and solid loading rate of 20 kg $TS/m^{2}{\cdot}d$ was proposed as a design parameter for gravity thickeners. Finally, the material mass-balance was made for the design of each unit process in the residual treatment train.

Bacillus subtilis를 이용한 폐수처리 효과연구: 오존의 영향을 중심으로 (Study of wastewater-treatment's efficiency using Bacillus subtilis: with an effect of ozonation)

  • 박영규
    • 환경위생공학
    • /
    • 제17권4호
    • /
    • pp.29-38
    • /
    • 2002
  • Advanced oxidation of wastewater was studied with a purpose to remove TOC and color by the ozone-assisted Fenton reaction. The optimal conditions were determined by hydrogen peroxide and ozone concentrations. Experimental results indicate that the ozone treatment after Fentons process was found to provide very efficient removal efficiency in the process, avoiding the exclusive ozone treatment. The combined process of ozone in the Fenton oxidation respectively was increased removal efficiences of 10.7% in comparison with exclusive Fenton oxidation. Also, the treatments of ozone after Fenton's oxidation respectively had increased the removal efficiences of 16.%. As a result, the treatment of ozone after Fentons oxidation had the best removal efficiency of approximately 96%. Removal efficiency of color was significantly increased as mush as 26% by the advanced Fenton's oxidation in comparison with exclusive Fenton's oxidation. The removal efficiencies in the biological treatment using Bacillus subtilis after Fenton's oxidation and after Fenton's and ozone's oxidation were increased by 14% and 19% respectively. Although these combined Bacillus subtilis-assisted Fenton's oxidation was determined to be effective method to treat the dyeing wastewater in an economic point of view, the choice of wastewater treatment can be varied depending on water quality.