• 제목/요약/키워드: Advanced Water Treatment Process

검색결과 342건 처리시간 0.028초

산업폐수 중의 질소 성분의 제거를 위한 고도처리 공정의 응용 (Application of Advanced Treatment Process for Nitrogen Compounds Removal of Industrial Waste-water)

  • 방성훈;임은태;정귀택;박재희;박석환;김성준;박돈희
    • KSBB Journal
    • /
    • 제23권6호
    • /
    • pp.541-545
    • /
    • 2008
  • This paper was studied to research regarding the removal of contained nitrogen in industrial wastewater which uses the A2O4 advanced water treatment process. The field researches of two companies' wastewater occurred in each wastewater treatment site to apply the A2O4 process system, it was observed them for 20 days. As a result of the A2O4 system advanced wastewater process which applied an altitude control process obtained $10{\sim}76\;mg/L$, and 20 mg/L total nitrogen compound concentration in the two wastewater plants. In conclusion, it applied the A2O4 system in the two companies' wastewater system.

세라믹막(MF) 고도정수처리에서 NOM 제거 특성 (Removal characteristics of NOM in advanced water treatment using ceramic MF membrane)

  • 유상준;박성한;임재림;서정민;장성호;홍성철;이병인
    • 상하수도학회지
    • /
    • 제28권4호
    • /
    • pp.367-376
    • /
    • 2014
  • This study assessed the removal efficiency of NOM which is known as the precursors of DBPs in advanced water treatment using the ceramic membrane filtration, introduced the first in the nation at the Y water treatment plant (WTP). It is generally well-known that the removal of NOM by MF Membrane is very low in water treatment process. But, the result of investigation on removal efficiency of NOM in advanced water treatment using the ceramic membrane was different as follows. The removal rate of organic contaminant by the ceramic membrane advanced water treatment was determined to be 65.5% for the DOC, 85.8% for UV254, and 77 to 86% for DBPFP. The removal rate of pre-ozonation was found to be 6 to 15% more effective compared with the pre-chlorination. The removal rate of DOC and $UV_{254}$ in biological activated carbon(BAC) process was over 50% and 75%, respectively although the rate was decreased 10 ~ 20% according to analysis items in converting from GAC to BAC.

정수처리에서의 Peroxone ($O_3/H_2O_2$) 공정 (Peroxone ($O_3/H_2O_2$) Process in Drinking Water Treatment)

  • 손희종;염훈식;빈재훈
    • 대한환경공학회지
    • /
    • 제32권3호
    • /
    • pp.296-308
    • /
    • 2010
  • Peroxone 공정은 정수처리 공정에서 기존의 염소와 오존 공정들의 여러 가지 한계점들을 극복할 수 있는 공정이다. 과산화수소와 오존에 의해 생성되는 OH 라디칼은 다양한 유기성 오염물질들에 대해 빠른 산화분해 및 높은 제거효율을 나타낸다. Peroxone 공정을 운영하는데 있어 주요 과제는 OH 라디칼 생성을 저해시키는 또는 생성된 OH 라디칼을 소모시키는 scavenger들과 공존할 때 peroxone 공정의 효율을 높일 수 있는 방안을 강구하는 것이다. Bromate와 같은 무기성 산화 부산물의 생성을 최소화할 수 있는 방안과 peroxone 공정 처리 후 염소 소독시 생성되는 염소 소독부산물들의 생성을 보다 저감할 수 있는 방안에 대해서도 많은 연구가 필요하다. 또한, 수중에 잔류하는 과산화수소에 대한 문제이다. 잔류 과산화수소를 on-line으로 측정할 수 있는 정밀한 측정장비의 개발 및 보급이 우선되어야 peroxone 공정의 운영에 있어서 안전성이 확보될 수 있다. 이러한 과제들이 해결이 된다면 peroxone 공정은 보다 다양한 목적으로 정수처리에 효율적으로 적용될 수 있을 것이다.

전기응집을 이용한 2차 유출수의 질소.인 제거 공정 연구 (Removal of nitrogen and phosphorus of the secondary effluent by electro-coagulation)

  • 한송희;장인성
    • 상하수도학회지
    • /
    • 제26권4호
    • /
    • pp.579-589
    • /
    • 2012
  • To reduce extensive energy costs of the internal recycling for the purpose of denitrification in the advanced wastewater treatment, a post-treatment process using an electro-coagulation to treat nitrate in the secondary effluents is evaluated in this study. Removals of phosphorus and organics in the secondary effluents by the electro-coagulation were also evaluated to propose an alternative advanced wastewatert treatment process. A series of experiments of the electro-coagulation were carried out with the following 4 different samples: synthetic solution containing nitrate only, synthetic solution containing nitrate as well as phosphorus, secondary effluents from activated sludge cultivated in laboratory, and secondary effluents from real wastewater treatment plants. Removals of nitrate and phosphorus in the synthetic solution were 30 and 97 % respectively, which verified the feasibility of the process. Removals of nitrate, phosphorus and COD in the secondary effluents from the cultivated sludge in laboratory were 49, 90 and 19 % respectively. Removal efficiency of the total nitrogen, nitrrate, phosphorus and COD in the secondary effluent from real wastewater treatment plant were 50, 61, 98 and 80 % respectively. The removal of the total nitrogen was less than the nitrate as expected, which is due to the formation of ammonia nitrogen in the cathode. But the proposed scheme could be an energy saving and alternative process for the advanced wastewater treatment if further studies for the process optimization are carried out.

고도정수처리에 따른 상수도 공급과정에서의 소독부산물 농도 예측모델 개발 (Development of a Concentration Prediction Model for Disinfection By-product according to Introduce the Advanced Water Treatment Process in Water Supply Network)

  • 서지원;김기범;김기범;구자용
    • 상하수도학회지
    • /
    • 제31권5호
    • /
    • pp.421-430
    • /
    • 2017
  • In this study, a model was developed to predict for Disinfection By-Products (DBPs) generated in water supply networks and consumer premises, before and after the introduction of advanced water purification facilities. Based on two-way ANOVA, which was carried out to statistically verify the water quality difference in the water supply network according to introduce the advanced water treatment process. The water quality before and after advanced water purification was shown to have a statistically significant difference. A multiple regression model was developed to predict the concentration of DBPs in consumer premises before and after the introduction of advanced water purification facilities. The prediction model developed for the concentration of DBPs accurately simulated the actual measurements, as its coefficients of correlation with the actual measurements were all 0.88 or higher. In addition, the prediction for the period not used in the model development to verify the developed model also showed coefficients of correlation with the actual measurements of 0.96 or higher. As the prediction model developed in this study has an advantage in that the variables that compose the model are relatively simple when compared with those of models developed in previous studies, it is considered highly usable for further study and field application. The methodology proposed in this study and the study findings can be used to meet the level of consumer requirement related to DBPs and to analyze and set the service level when establishing a master plan for development of water supply, and a water supply facility asset management plan.

자외선/염소 반응해석 모델에 의한 미량유기물질 제거에 관한 연구 (Removal of microorganic pollutants based on reaction model of UV/chlorine process)

  • 황태문;남숙현;권민환;강준원
    • 상하수도학회지
    • /
    • 제31권1호
    • /
    • pp.73-81
    • /
    • 2017
  • The UV/chlorine process is a UV-based advanced oxidation process for removing various organic pollutants in water. The process is becoming increasingly popular because of its effectiveness in practice. It is important to the safe and efficient operation of a UV/chlorine process that the optimal operating conditions for both target removal objective and saving energy are determined. Treatment efficiency of target compounds in UV/chlorine process was mainly affected by pH and scavenging factor. In this study, kinetic based mathematical model considering water characteristics and electrical energy dose calculations model was developed to predict of treatment efficiency and optimal operating conditions. The model equation was validated for the UV/chlorine process at the laboratory scale and in pilot tests at water treatment plants.

고급산화공정을 이용한 염료폐수의 처리기술 연구 (A Study on the Dye Wastewater Treatment by Advanced Oxidation Process)

  • 강태희;오병수;박세준;강민구;김종성;강준원
    • 한국물환경학회지
    • /
    • 제21권3호
    • /
    • pp.267-273
    • /
    • 2005
  • Dye wastewater generally contains strong color and non-biodegradable materials. Therefore, the conventional wastewater treatment plant can hardly meet the regulation of wastewater effluent water. In this study, a pilot plant of the conventional process followed by advanced oxidation process (AOP), was set up to treat the dying wastewater. The treatment efficiencies on the various candidate processes, such as ozone alone, UV alone, ozone/UV, $ozone/H_2O_2$, $H_2O_2/UV$ and $ozone/UV/H_2O_2$, were investigated in the various ozone and $H_2O_2$ doses. As the results, the $ozone/H_2O_2$ process, among the tested processes, showed the highest efficiency for removing color and $COD_{Cr}$. For color removal, the ozone alone process was enough without combining UV or $H_2O_2$. No significantly enhanced efficiency for removing color and $COD_{Cr}$ by UV irradiation was observed because of the very low transmittance of UV light in dye wastewater.

전기화학적 처리에 의한 배추 절임염수 재이용 가능성 평가 (Evaluation of brine reuse on salting of chinese cabbage using electrochemical process)

  • 정희숙;이은실;한성국;한응수
    • 상하수도학회지
    • /
    • 제28권5호
    • /
    • pp.541-548
    • /
    • 2014
  • The pickling brine generated from the salting process of kimchi production is difficult to treat biologically due to very high content of salt. When pickling brine is treated and discharged, it cannot satisfy the criteria for effluent water quality in clean areas, while resources such as the salt to be recycled and the industrial water are wasted. However, sterilization by ozone, UV and photocatalyst is expensive installation costs and operating costs when considering the small kimchi manufacturers. Therefore there is a need to develop economical process. The study was conducted on the sterilization efficiency of the pickling brine using electrochemical processing. The electrochemical treatment of organic matters has advantages over conventional methods such as active carbon absorption process, chemical oxidation, and biological treatment because the response speed is faster and it does not require expensive, harmful oxidizing agents. This study were performed to examine the possibility of electrochemical treatment for the efficient processing of pickling brine and evaluated the performance of residual chlorine for the microbial sterilization.

고도정수처리 신(新) 공정(PMR)개발 및 처리효율 평가 (Development of a New Advanced Water Treatment Process (PMR) and Assessment of Its Treatment Efficiency)

  • 안효원;노수홍;권오성;박용효;왕창근
    • 멤브레인
    • /
    • 제18권2호
    • /
    • pp.157-167
    • /
    • 2008
  • 수돗물 공급에 있어서의 미량 유기물질 및 맛냄새 제거의 중요도가 높아짐에 따라 오존, GAC 및 PAC 등 고도 정수처리공정의 도입이 지속적으로 증대되고 있다. 하지만, 원수의 수질악화, 새로운 오염물질의 출현 등에 의해 기존의 고도처리공정이 향후에도 충분한 대안이 된다고 확신하기는 어려운 실정이다. 본 연구에서는 고농도의 분말활성탄을 slurry blanket의 형태로 체류시킨다는 새로운 개념의 접촉조를 구상, 막여과조와 연계하여 하나의 공정으로 완성하였다. 한강원수를 대상으로 $80m^3/일$ 규모의 pilot plant를 이용, 유기물질 및 2-MIB, Geosmin에 대한 제거특성을 살펴본 결과 DOC의 경우 운영초기 90% 이상, 안정화된 이후에도 $70{\sim}80%$ 내외의 높은 처리효율을 나타내었으며 2-MIB Geosmin의 경우 검출한계 이하로 제거되었다. 본 공정은 1년 이상의 장기간의 고도처리 효율 검증 및 안정된 PAC 접촉조의 운영방안 등 공정 최적화를 위한 추가적인 연구가 필요한 실정이나 기존의 고도처리에 비해 컴팩트하면서 높은 처리효율을 안정적으로 나타냄으로써 맛냄새물질을 비롯한 미량 오염물질을 제거하기 위한 대안공정으로서의 높은 가능성을 확인하였다.

상수고도정수처리의 효율적 이용을 위한 경제성 검토 (Economic Feasibility Study on the Efficient Use of Advanced Water Treatment for Water Supply)

  • 이상일
    • 물과 미래
    • /
    • 제29권1호
    • /
    • pp.191-202
    • /
    • 1996
  • 기존의 정수처리기법으로는 처리되지 않는 여러 가지 유기물질의 처리를 위해 상수고도처리가 도입되고 있다. 국내실정에 적합한 고도정수처리 시스템의 개발과 아울러, 이를 실생활에 도입할 경우의 소요비용과 사회적 영향에 대한 연구도 필요하다. 본 연구에서는 고도정수처리시스템의 설비비와 유지보수비를 산정하는 방법을 오존과 활성탄, 그리고 막분리 시스템을 중심으로 제시하고 이를 정부예산과 비교하여 타당성을 검증하였다. 또한 이를 바탕으로 투자비와 시설용랑에 관한 일반적인 관계식도 유도하였다. 한편, 정수된 상질의 물을 수요자에게 공급하는 방안을 네 가지로 검토하고 이를 부산지역에 적용하였다. 생산량과 수송체계에 따른 각각의 대안을 경제적/사회적 측면에서 비교한 결과, 음용수만을 고도정수처리하여 관로를 통하지 않고 병물로 공급하는 방안이 수질을 떨어뜨리지 않으면서 가장 경제성이 있는 방법인것으로 나타났다.

  • PDF