• 제목/요약/키워드: Advanced Wastewater Treatment

검색결과 376건 처리시간 0.03초

FAULT DETECTION, MONITORING AND DIAGNOSIS OF SEQUENCING BATCH REACTOR FOR INTEGRATED WASTEWATER TREATMENT MANAGEMENT SYSTEM

  • Yoo, Chang-Kyoo;Vanrolleghem, Peter A.;Lee, In-Beum
    • Environmental Engineering Research
    • /
    • 제11권2호
    • /
    • pp.63-76
    • /
    • 2006
  • Multivariate analysis and batch monitoring on a pilot-scale sequencing batch reactor (SBR) are described for integrated wastewater treatment management system, where a batchwise multiway independent component analysis method (MICA) are used to extract meaningful hidden information from non-Gaussian wastewater treatment data. Three-way batch data of SBR are unfolded batch-wisely, and then a non-Gaussian multivariate monitoring method is used to capture the non-Gaussian characteristics of normal batches in biological wastewater treatment plant. It is successfully applied to an 80L SBR for biological wastewater treatment, which is characterized by a variety of error sources with non-Gaussian characteristics. The batchwise multivariate monitoring results of a pilot-scale SBR for integrated wastewater treatment management system showed more powerful monitoring performance on a WWTP application than the conventional method since it can extract non-Gaussian source signals which are independent and cross-correlation of variables.

BIO-CLOD를 이용한 고도처리공정에서의 영양염류 제거 (Nutrient Removal in an Advanced Treatment Process using BIO-CLOD)

  • 박완철;이미애;성일화
    • 한국환경보건학회지
    • /
    • 제40권4호
    • /
    • pp.322-329
    • /
    • 2014
  • Objectives: The purpose of this study was to investigate the effect of BIO-CLOD on advanced wastewater treatment for enhanced removal efficiency and meeting the stringent discharge water requirements of wastewater treatment plants. Methods: Two experimental apparatuses consisting of anaerobic, anoxic and aeration tanks were operated. One included a BIO-CLOD cultivation tank. Organic and nutrient parameters and removal efficiency were analyzed by pH, BOD, CODcr, SS, T-N and T-P. Results: The average removal efficiencies of BOD, COD and SS from the apparatus with BIO-CLOD tank installation were 95.5%, 88.6% and 92.9%, respectively, and these were higher than the results from the apparatus without BIO-CLOD. The average TP removal efficiency with BIO-CLOD tank marked 56.0%, higher than the 47.3% from the apparatus without one. BIO-CLOD showed a higher performance for TN removal at 49.6%, compared to the result without BIO-CLOD of 34.3% Conclusion: By reaction with BIO-CLOD, ammonia removal was effective in the aeration tank, as was phosphorus release in the anaerobic tank. Phosphorus luxury uptake and nitrification in aeration tank proceeded smoothly. The application of BIO-CLOD can improve the decrease of odor and settleability of activated sludge in a wastewater treatment plant, as well as increase the removal efficiency of organic and nutrient materials in water.

고도처리 효율 향상을 위한 통계적 접근 (Improvement of Operating Efficiency on Advanced Wastewater Plant Using Statistical Approach)

  • 문경숙;민경섭;김승민;이찬형
    • 한국환경과학회지
    • /
    • 제17권4호
    • /
    • pp.405-412
    • /
    • 2008
  • Statistical analysis technique was applied to operating parameters and removal efficiency data sets obtained from advanced wastewater treatment plant during 1 year. Through factor analysis three factors derived varimax rotation were selected each plant. Three components explained 96%, 87% of the total variance of the process, respectively. The components on $A_2O$ Plant were identified in the following order : 1) Shortening the SRT during high-flow period, 2) Keeping biomass high on winter 3) factor was related to DO. On DNR plant, we defined them as follows: factor 1, Prolonged the SRT during high-flow period; factor 2 was related to sludge return; factor 3, Influent BOD during low-DO period. This technique was believed to assist operators in identifying priorities to improve operation efficiency.

Membrane Filter를 이용한 수산물 가공폐수처리에 대한 연구 (Research of Sea Food Wastewater Treatment using Membrane Filter)

  • 한동준
    • 환경위생공학
    • /
    • 제22권4호
    • /
    • pp.119-130
    • /
    • 2007
  • Sea food wastewater including high concentration of organics and nutrients is hard to treat stably by established traditional activated sludge process. This research is aimed to obey more and more of strengthened the law and to secure stable effluents by using advanced treatment process applied membrane filter in aeration tank for treatment of wastewater from marine products. It must maintain pH of influent over 6.0 to keep up stably biological sludge of advanced treatment process. At 38hr of HRT, removal rates of TBOD and TCOD were 99.9% and 99.4% respectively and TSS also removed with high efficiency. Most organics in the effluent was constituted with soluble type materials, it caused that membrane filter installed aeration tank should remove minute suspended particles. The reactor was operated well to get stable treatment results for operation period, in spite of high loading of organics like that $0.67{\sim}1.67\;kgTBOD/m^3/day$ of organics loading and $0.10{\sim}0.21\;kgBOD_5/kgMLSS/day$ of F/M ratio. At $36{\sim}48hr$ of HRT, removal rates of T-N and T-P were $89.7{\sim}90.7%\;and\;91.5{\sim}96.0%$ respectively. It means this treatment process also work to remove nutrients of high concentration. Upon investigation of advanced treatment's operation factors, optimum SRT was about 30days and average SNR that showed tendency to increase according to increase water temperature was calculated 0.014 gN/g MLVSS/d. SDNR was risen in conformity to increase F/M ratio of Non-aeration tank and investigated as $0.038{\sim}0.051\;gN/gMLVSS/d$.

부레옥잠을 이용한 생활하수의 고도처리에 관한 연구( I ) (A Study on Advanced Treatment of Sewage Wastewater by Eichhornia crassipes)

  • 정순형
    • 환경위생공학
    • /
    • 제18권3호통권49호
    • /
    • pp.69-77
    • /
    • 2003
  • The present time, water hyacinth(Eichhornia crassipes) was widely used for a purification of a polluted lake, livestock wastewater and sewage wastewater treatment. This study was conducted to evaluate the propriety of sewage wastewater treatment by water hyacinth(Eichhornia crassipes). On the study of optimal cultivation density, 3 kg/m$^2$ was selected for the most suitable initial cultivation density through the BOD, T-N and T-removal efficiency. In experiment of purification capacity, hyacinth(Eichhornia crassipes) removed the 267.2 mg BOD/kg · day, 72 mg T-N/kg · day and 8.6 mg T-P/kg · day at 30 operation days respectively. The result showed that hyacinth(Eichhornia crassipes) could be used for recovery of eutrophic lake effectively. In the test of optimal HRT(hydraulic retention time), 9 days was selected with the suitable HRT, and BOD, T-N and T-P were removed with 75%, T-N 88% and T-P 97% respectively.

MHD 수처리방식에 의한 에멀젼오일폐수의 처리 (Emulsified Oily Wastewater Treatment by MHD Water Treatment Device)

  • 김인수;박승조
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권4호
    • /
    • pp.20-27
    • /
    • 1993
  • Emulsified oily wastewater is generally hard to treat in separating oil and water by conventional separators. In this paper the magnetohydrodynamic water treatment device was used to separate oil from emulsified oily wastewater which contained high conductivity. The emulsified oil removal rates and economic ranges of oil separation at various factors were investigated to confirm the influence of the magnetic field in MHD water treatment device according to the characteristics of emulsion brake. Experimental results proved that the oil removal rates were proportional to Lorentz force which depends on the intensity of magnetic field, conductivity and velocity of wastewater.

  • PDF

미세조류를 이용한 양돈폐수 고도처리에서 슬러지 및 이산화탄소의 첨가의 영향 (Effects of sludge and $CO_2$ addition on advanced treatment of swine wastewater by using microalgae)

  • 임병란;박기영;이기세;이수구
    • 상하수도학회지
    • /
    • 제25권3호
    • /
    • pp.307-312
    • /
    • 2011
  • The potential of algal-bacterial culture was investigated for advanced treatment of animal wastewater. Fed-batch experiments were carried out to examine treatability of nitrogen and phosphorus in different microbial consortium: Chlorella vulgaris, activated sludge, three microalgae strains (Scenedesmus, Microcystis, Chlorella) and Bacillus consortium, and three microalgae strains and sludge consortium. Single culture of C. vugaris showed the better efficiency for nitrogen removal but was not good at organic matter and phosphorus removal compared with activated sludge. Three microalgae and Bacillus consortium was best culture among the culture and consortium for pollutants removal tested in this experiment. Effect of $CO_2$ addition was studied by using three microalgae and Bacillus consortium. $CO_2$ addition enhanced T-P removal efficiency up to 60%. However, removal efficiencies of T-N and ammonia nitrogen reduced on the contrary.

침지식 중공사막을 결합한 Dynamic state 하수고도처리공정(KSMBR process)의 개발 및 현장적용평가 (Development and Field Application of the Advanced Wastewater Treatment process (KSMBR) by Hollow Fiber Submerged Membrane)

  • 김지연;서인석;김홍석;김연권;김병군;최창규;안효원;서완석;장문석
    • 한국물환경학회지
    • /
    • 제22권2호
    • /
    • pp.358-363
    • /
    • 2006
  • KSMBR process is dynamic state advanced wastewater treatment applied with Trisectional Aeration (TSA) mode combined with membrane. TSA was remodeled conventional intermittent aeration which was operated nonaeration-aeration. TSA operates nonaeration ($N_1$) - aeration (A) - nonaeration ($N_2$) in Trisectional Aeration Reactor (TAR). Organics of influent could be nearly consumed to denitrification without influence by remained DO in TAR and it could be operated about sludge return ratio of 1Q (influent base). The purpose of this study was to apply KSMBR to the full-scale plant and to evaluate efficiency of nitrogen and phosphorus removal and TSA operation. The result of this study, average CODcr/T-N and CODcr/T-P ratio were 7.8 and 59.6, respectively. BOD, TCODcr, SS, T-N, T-P, E-coli removal efficiency were 98.4, 95.2, 73.0, 69.6, 99.95 %, respectively. KSMBR obtained high removal efficiencies of C, N and P when it applied full-scale plant.

Integrated Applications of Microalgae to Wastewater Treatment and Biorefinery: Recent Advances and Opportunities

  • Nguyen, Van Tuyen;Limjuco, Lawrence A.;Lee, Kisay;Dang, Nhat Minh
    • 공업화학
    • /
    • 제33권3호
    • /
    • pp.242-257
    • /
    • 2022
  • Microalgae is becoming a vital component for a circular economy and ultimately for sustainable development. Herein, recent developments in different outcomes of microalgae for wastewater treatment and biorefinery were reviewed. From its primary function as a third-generation resource of biofuel, the usage of microalgae has been diversified as an integral element for the CO2 sequestration and production of economically valuable products (e.g., pharmaceuticals, animal feeds, biofertilizer, biochar, etc.). Principles and recent challenges for each microalgae application were presented to suggest a motivation for future research and the direction of development. The integration of microalgae within the concept of the circular economy was also discussed with various routes of microalgae-based biorefinery.

효과적 공간활용을 위한 Side Stream Plug-Flow Reactor를 이용한 하수 고도처리 공정 적용에 관한 연구 (A study on Applicable to Advanced treatment of using Side Stream Plug-Flow Reactor)

  • 김삼주;현인환;독고석
    • 상하수도학회지
    • /
    • 제22권3호
    • /
    • pp.367-372
    • /
    • 2008
  • This study configured the conventional $A^2O$ (Anaerobic-Anoxic-Aerobic bioreactor) system which the fixed media immersed into the anoxic reactor(Named PFR system : Plug Flow Reactor) for evaluating the removal efficiency of nitrogen in the wastewater. The experimental equipment was a cylinder which was consist of 4 pleated PE Pipes(Length 330M, Diameter 100mm) including 2 rope shape media. As a result, the average effluent T-N removal efficiency of the conventional $A^2O$ system was 17.9, 40.3, 50.6, 44.6% in each mode, but the average effluent T-N removal efficiency of the PFR system could achieve 38.8, 57.1, 71.8, 65.4% in each mode. It indicated that the PFR system caused to the increasing of C/N ratio that effected to the increasing of the denitrification efficiency. Not only the effective T-N removal efficiency but also the controllable install space will give advantages for retrofitting of the wastewater treatment plant with the conventional treatment system to the PFR system.