• Title/Summary/Keyword: Advanced Dentistry

Search Result 1,048, Processing Time 0.039 seconds

Bond strength of veneer ceramic and zirconia cores with different surface modifications after microwave sintering

  • Saka, Muhammet;Yuzugullu, Bulem
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.485-493
    • /
    • 2013
  • PURPOSE. To evaluate the effects of surface treatments on shear bond strength (SBS) between microwave and conventionally sintered zirconia core/veneers. MATERIALS AND METHODS. 96 disc shaped Noritake Alliance zirconia specimens were fabricated using YenaDent CAM unit and were divided in 2 groups with respect to microwave or conventional methods (n=48/group). Surface roughness (Ra) evaluation was made with a profilometer on randomly selected microwave (n=10) and conventionally sintered (n=10) cores. Specimens were then assessed into 4 subgroups according to surface treatments applied (n=12/group). Groups for microwave (M) and conventionally (C) sintered core specimens were as follows; $M_C$,$C_C$: untreated (control group), $M_1,C_1:Al_2O_3$ sandblasting, $M_2,C_2$:liner, $M_3,C_3:Al_2O_3$ sandblasting followed by liner. Veneer ceramic was fired on zirconia cores and specimens were thermocycled (6000 cycles between $5^{\circ}-55^{\circ}C$). All specimens were subjected to SBS test using a universal testing machine at 0.5 mm/min, failure were evaluated under an optical microscope. Data were statistically analyzed using Shapiro Wilk, Levene, Post-hoc Tukey HSD and Student's t tests, Two-Way-Variance- Analysis and One-Way-Variance-Analysis (${\alpha}$=.05). RESULTS. Conventionally sintered specimens ($1.06{\pm}0.32{\mu}m$) showed rougher surfaces compared to microwave sintered ones ($0.76{\pm}0.32{\mu}m$)(P=.046), however, no correlation was found between SBS and surface roughness (r=-0.109, P=.658). The statistical comparison of the shear bond strengths of $C_3$ and $C_1$ group (P=.015); $C_C$ and $M_C$ group (P=.004) and $C_3$ and $M_3$ group presented statistically higher (P=.005) values. While adhesive failure was not seen in any of the groups, cohesive and combined patterns were seen in all groups. CONCLUSION. Based on the results of this in-vitro study, $Al_2O_{3-}$ sandblasting followed by liner application on conventionally sintered zirconia cores may be preferred to enhance bond strength.

A comparative study on the accuracy of the devices for measuring the implant stability

  • Cho, In-Ho;Lee, Young-Il;Kim, Young-Mi
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.3
    • /
    • pp.124-128
    • /
    • 2009
  • STATEMENT OF PROBLEM. How the ISQ values measured by $Osstell^{TM}$ and $Osstell^{TM}$ Mentor are related, and whether the ISQ values acquired from the two machines changes in accordance with changes in implant stability are not yet fully understood. PURPOSE. The aim of this study was to find out correlation between the ISQ values acquired from $Osstell^{TM}$ and $Osstell^{TM}$ Mentor, and to evaluate the clinical effectiveness and accuracy of two devices. MATERIAL AND METHODS. Sixty two implants were inserted into 47 patients, and their ISQ values were measured using $Osstell^{TM}$ and $Osstell^{TM}$ Mentor. In the first stage surgery, the ISQ values of forty four implants inserted into thirty five patients were measured. In the second stage surgery, the values of fifty implants inserted into thirty seven patients were measured. The values were analyzed to determine the difference between the mean ISQ values of $Osstell^{TM}$ and $Osstell^{TM}$ Mentor. In addition, the correlation between implants used in the first and second stage of surgery with regard to their types and areas of insertion were analyzed. The difference between the ISQ values of 32 implants in each patient during the first and second stage was analyzed. The statistical assessment was carried out using SPSS V. 12.0 for Win. (SPSS Inc., Chicago, USA). The Pearson correlation coefficient was used to examine the correlation between $Osstell^{TM}$ and $Osstell^{TM}$ Mentor in the first and second stages of surgery, whereas the difference between their ISQ values was evaluated using a paired t-test. RESULTS. In the first stage, the mean ISQ value for $Osstell^{TM}$ and $Osstell^{TM}$ Mentor was 70.84 and 75.09, respectively, showing a significant difference (P < .01). In the second stage, the mean ISQ value of $Osstell^{TM}$ and $Osstell^{TM}$ Mentor was 71.76 and 75.94, respectively, also showing a significant difference (P < .01). The difference between the ISQ values in patients in the first and the second stages was significant with both instruments. CONCLUSION. The significant difference in the values obtained using the $Osstell^{TM}$ and $Osstell^{TM}$ Mentor between the first and second stages of implant surgery indicates that these values can be a convenient and precise way for evaluating the implant stability in clinical practice.

A HISTOLOGIC STUDY OF THE OSSEOINTEGRATION PROCESS TO THE TITANIUM TOOTH ROOT IMPLANT (타이타늄 치근형 매식체에 대한 골유착 과정에 관한 조직학적 연구)

  • Ahn, Chang Young;Kim, Yung Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.2
    • /
    • pp.1-28
    • /
    • 1990
  • The severe atrophic edentulism with poor neuromuscular control militates against successful conventional denture therapy. To such situation, a prescribing of dental implant treatment has been considered with some probability. Implant materials used as a trial for dental implants includes metals, plastic polymers and ceramics. The purpose of this study was to observe histologic response in osseointegration process at titanium implant-tissue interface based on biocompatibility at specific period of sequential natures which were divided into a half month, one, month, two months, three months and immediate as a base line. In this study, unilateral lower left premolar and molar teeth were extraced in three dogs. After allowing to heal for 6 months, three kinds of osseointegrated implant, $Br{\aa}nemark$, Corevent and kimplant(a prototype of SNU implant study)were inserted in each dog respectively according to the above sequence from front to back. The specimens were taken from those dogs at the same time since implant were inserted quite reverse order of the specified periods, and decalcified and processed for histologic examination for the light microscopy and the electron microscopy. The microscopic histologic findings at the interface between titanium implants and tissue were interpretated as follows : A. Light microscopic findings : a. Immediate : Implant were surrounded by compact bone and spongy bone. Microcrak was observed in the superficial bone tissue. Osteocytes were disappeared and bone lacunae were observed as a vacant space in some parts. In the contacting with the spongy bone, bone trabeculae and bone marrow were in contact with the implant. b. A half Month : Osteoblasts exist as a monolayer in th inner bone trabeculae and do bone additiocn. Osteoblasts&inflammatory cells were observed in some parts. c. One Month : The presence of osteoclasts decreased. Osteoblasts did active bone fromation, and bone marrow was in contact with the implant in the many places. d. Two Months : Bone formation was advanced in comparison with the b and c. The presence of osteoclsts was not observed. e. Three Months : The superficial bone tissue contacted with the implants was entirely composed by the compact bone. B. Electron microscopic findings : a. A half month and one month group : In the parts of the active bone formation, osteoblasts with the well developed endoplasmic reticulum and Golgi apparatus were arranged in the monolayer. In the parts of the bone resorption, ruffled border was well developed and many osteoclasts with the well-developed golgi apparatus, mitochondria, vacuole, vesicle and lysosome were existed. b. Three months group : No osteoblasts were observed in the superficial bone tissue. Bone matrix with collaen fiber was observed. c. No significant dirrerence in the histologic findings was observed in $Br{\aa}nemark$, Core-vent and kimplant.

  • PDF

A STUDY ON SHEAR BOND STRENGTH OF INTERFACE BETWEEN BONE AND TITANIUM PLASMA SPRAYED IMZ IMPLANT IN RABBITS (가토에 이식된 Titanium plasma Sprayed IMZ 임프란트와 골의 계면 접촉 양상에 따른 결합력에 관한 연구)

  • Han, Chong-Hyun;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.2
    • /
    • pp.225-243
    • /
    • 1991
  • In recent years immediate implantation has been tried by a few clinicians. This study placed IMZ implants in the rabbit femur with and without bony defects around the implant for simulating fresh extraction site. And one group with bony defects used porous hydroxyapatite ganules(HA) to fill if and the other group left the bony defects around the implant. The purpose of this study was to compare the shear bond strength and the bony contact and formation around the implant. Fifteen rabbits were divided into three groups and placed 10 IMZ implants to each group. Implant sites were surgically prepared with IMZ drills kit and implants were placed(Control), artificial bony defect was created with Apaceram drills kit around the implant sites and implants were placed(Experimental I), bony defect was filled with porous hydroxyapatite granules(Experimental II). Thereafter, rabbits were sacrificed at 8th week and specimens were prepared and pushout tested for shear bond strength of bone-implant interface immediately. Undecalcified and decalcified specimens were prepared with Vilanueva and hematoxylin-eosin stain for light microscopic finding. The results of this study were as follows. 1. In the control group, mean shear strength of bone-implant interface was $2.614{\pm}0.680$ MPa, experimental I was $0.664{\pm}0.322$ MPa, and experimental II was $2.281{\pm}0.606$ MPa. There was significant difference between control and experimental I, between experimental I and experimental II, but did not show significant difference between control and experimental II statistically. 2. In the bony formation surrounding IMZ implant of the three groups, that of cortical bone is more advanced than cancellous bone area. 3. In the histological findings of undecalcified specimens, control and experimental II showed more than 50% of bony or osteoid formation at the bony-implant interface. 4. In the histological findings of undecalcified specimens, experimental I showed less than 50% of bony or osteoid formation at the interface, and observed partial bony defect in the coronal zone. 5. In the experimental II group, were observed direct bony contact to hydroxyapatite granules, and infiltration of a few giant cells. 6. No inflammatory responses were seen around the titanium implants and the hydroxyapatite granules.

  • PDF

The effect of immobilization of heparin and bone morphogenic protein-2 to bovine bone substitute on osteoblast-like cell's function

  • Huh, Jung-Bo;Kim, Sung-Eun;Song, Se-Kyung;Yun, Mi-Jung;Shim, Ji-Suk;Lee, Jeong-Yo;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.3 no.3
    • /
    • pp.145-151
    • /
    • 2011
  • PURPOSE. This study was performed to investigate the ability of recombinant human-bone morphogenic protein-2 immobilized on a heparin-grafted bone substrate to enhance the osteoblastic functions. MATERIALS AND METHODS. The Bio-$Oss^{(R)}$, not coated with any material, was used as a control group. In rhBMP-2-Bio-$Oss^{(R)}$ group, rhBMP-2 was coated with Bio-$Oss^{(R)}$ using only deep and dry methods (50 ng/mL, 24 h). In heparinized rhBMP-2-Bio-$Oss^{(R)}$ group, dopamine was anchored to the surface of Bio-$Oss^{(R)}$, and coated with heparin. rhBMP-2 was immobilized onto the heparinized- Bio-$Oss^{(R)}$ surface. The release kinetics of the rhBMP-2-Bio-$Oss^{(R)}$ and heparinized rhBMP-2-Bio-$Oss^{(R)}$ were analyzed using an enzyme-linked immunosorbent assay. The biological activities of the MG63 cells on the three groups were investigated via cytotoxicity assay, cell proliferation assay, alkaline phosphatase (ALP) measurement, and calcium deposition determination. Statistical comparisons were carried out by one-way ANOVA test. Differences were considered statistically significant at $^*$P<.05 and $^{**}$P<.001. RESULTS. The heparinized rhBMP-2-Bio-$Oss^{(R)}$ showed more sustained release compared to the rhBMP-2-Bio-$Oss^{(R)}$ over an extended time. In the measurement of the ALP activity, the heparinized group showed a significantly higher ALP activity when compared with the non-heparinized groups (P<.05). The MG63 cells cultivated in the group with rhBMP-2 showed increased calcium deposition, and the MG63 cells from the heparinized group increased more than those that were cultivated in the non-heparinized groups. CONCLUSION. Heparin increased the rhBMP-2 release amount and made sustained release possible, and heparinized Bio-$Oss^{(R)}$ with rhBMP-2 successfully improved the osteoblastic functions.

UNDERSTANDING OF EPIGENETICS AND DNA METHYLATION (인간 게놈의 Copy Number Variation과 유전자 질환)

  • Oh, Jung-Hwan;Nishimura, Ichiro
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.2
    • /
    • pp.205-212
    • /
    • 2008
  • Genetic variation in the human genome occurs on various levels; from the single nucleotide polymorphism to large, microscopically visible chromosome anomalies. It can be present in many forms, including variable number of tandem repeat (VNTRs; e.g., mini- and microsatellites), presence/absence of transposable elements (e.g., Alu elements), single nucleotide polymorphisms, and structural alterations (e.g., copy number variation, segmental duplication, inversion, translocation). Until recently SNPs were thought to be the main source of genetic and phenotypic human variation. However, the use of methods such as array comparative genomic hybridization (array CGH) and fluorescence in situ hybridization (FISH) have revealed the presence of copy number variations(CNVs) ranging from kilobases (kb) to megabases (Mb) in the human genome. There is great interest in the possibility that CNVs playa role in the etiology of common disease such as HIV-1/AIDS, diabetes, autoimmune disease, heart disease and cancer. The discovery of widespread copy number variation in human provides insights into genetic variability among populations and provides a foundation for studies of the contribution of CNVs to evolution and disease.

Gaussian Noise Reduction Method using Adaptive Total Variation : Application to Cone-Beam Computed Tomography Dental Image (적응형 총변이 기법을 이용한 가우시안 잡음 제거 방법: CBCT 치과 영상에 적용)

  • Kim, Joong-Hyuk;Kim, Jung-Chae;Kim, Kee-Deog;Yoo, Sun-K.
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.29-38
    • /
    • 2012
  • The noise generated in the process of obtaining the medical image acts as the element obstructing the image interpretation and diagnosis. To restore the true image from the image polluted from the noise, the total variation optimization algorithm was proposed by the R.O. F (L.Rudin, S Osher, E. Fatemi). This method removes the noise by fitting the balance of the regularity and fidelity. However, the blurring phenomenon of the border area generated in the process of performing the iterative operation cannot be avoided. In this paper, we propose the adaptive total variation method by mapping the control parameter to the proposed transfer function for minimizing boundary error. The proposed transfer function is determined by the noise variance and the local property of the image. The proposed method was applied to 464 tooth images. To evaluate proposed method performance, PSNR which is a indicator of signal and noise's signal power ratio was used. The experimental results show that the proposed method has better performance than other methods.

Dislodgement resistance of modified resin-bonded fixed partial dentures utilizing tooth undercuts: an in vitro study

  • Doh, Re-Mee;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.2
    • /
    • pp.85-90
    • /
    • 2009
  • STATEMENT OF PROBLEM. Over the years, resin-bonded fixed partial dentures (RBFPDs) have gone through substantial development and refinement. Several studies examined the biomechanics of tooth preparation and framework design in relation to the success rate of RBFPDs and considered retention and resistance form essential for increase of clinical retention. However, these criteria required preparations to be more invasive, which violates not only the original intentions of the RBFPD, but may also have an adverse effect on retention due to loss of enamel, an important factor in bonding. PURPOSE. The object of this in vitro study was to compare the dislodgement resistance of the new types of RBFPDs, the conventional three-unit fixed partial denture, and conventional design of RBFPD (Maryland bridge). MATERIAL AND METHODS. Fifty resin mandibular left second premolars and second molars were prepared on dentiforms, according to the RBFPD design. After model fabrication (five group, n = 10), prostheses were fabricated and cemented with zinc phosphate cement. After cementation, the specimens were subjected to tensile loading at a cross head speed of 4 mm/min in a universal testing machine. The separation load was recorded and analyzed statistically using one-way analysis of variance followed by Duncan's multiple range test. RESULTS. Group V, the pin-retained RBFPDs, had the highest mean dislodgement resistance, whereas specimens of group II, the conventional RBFPDs, exhibited a significantly lower mean dislodgement resistance compared to the other 4 groups (P <.05). There were no significant differences between group I, III, and IV in terms of dislodgement resistance (P>.05). Group V had the highest mean MPa (N/$mm^2$) (P <.05). There was no significant difference between groups I, II, III and IV (P > .05). CONCLUSION. Within the limits of the design of this in vitro study, it was concluded that: 1. The modified RBFPDs which utilizes the original tooth undercuts and requires no tooth preparation, compared with the conventional design of RBFPDs, has significantly high dislodgement resistance (P < .05). 2. The modified RBFPDs which utilizes the original tooth undercuts and requires minimal tooth preparation, compared with the conventional FPDs, has significantly no difference in retention and dislodgement resistance)(P>.05). 3. The pin-retained FPDs showed a high dislodgement resistance compared to the conventional three-unit FPDs (P<.05).

Morphometric study of the calculus and periodontal tissues adhered to the root surfaces in periodontitis (치주염이환 치아표면에 부착된 치석과 치주조직의 형태 계측학적 연구)

  • Kim, Chong-Kwan;Yi, Seung-Won
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.621-631
    • /
    • 1997
  • To verify the effect of subgingival calculus on the periodontal tissues in periodontitis and the effectiveness of supragingival scaling to remove the calculus, 30 teeth from healthy group (Probing pocket depth:$PPD{\leq}mm$: HP group), 15 teeth from moderate group ($4{\leq}PD<7mm$:MP group), 30 teeth from advanced group (PPD>7mm: AP group) were selected and supragingival scaling was performed before extraction of all experimental teeth. After careful extraction, the teeth were cleaned with saline and disclosed with toluidine blue and carefully examined the relationship and distance between the calculus attached on the root surface and periodontal tissues. As a result, it was; 1. The calculus was not discovered on the root surface of teeth in HP group, but was in MP and AP group, mostly on interproximal surface and furca area. The shape of the attached calculus was ovoid, trepazoid and polygonal and the calculus was distributed randomly over the root surface. 2. PPD was more than the distance between the gingival margin to the level of attached connective tissue in AP group rather than in HP and MP group. 3. The length of calculus was $2.7mm{\pm}.44mm$ in HP group and $4.1{\pm}.89in$ AP group. 4. The distance between the apical margin of calculus and the level of attached connective tissue was $2.4{\pm}.33mm$ in MP group and $3.4{\pm}.89mm$ in AP group. 5. The length of subgingival calculus was tended to increase in relation to the probing pocket depth. Therefore, it can be concluded, the calculus in periodontal pocket can not be removed completely with supragingival scaling. As the terminal part of calculus was far away with limited distance from the periodontal tissue, it can be said that the calculus was not a direct factor in destroying the periodontal tissue. In this study, the extent of the plaque was not verified but the location of calculus can be used in clinical practice for complete removal of calculus when the distance relation bewteen calculus and plaque will be known.

  • PDF

Mechanical behavior and microstructural characterization of different zirconia polycrystals in different thicknesses

  • Arcila, Laura Viviana Calvache;Ramos, Nathalia de Carvalho;Campos, Tiago Moreira Bastos;Dapieve, Kiara Serafini;Valandro, Luiz Felipe;de Melo, Renata Marques;Bottino, Marco Antonio
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.6
    • /
    • pp.385-395
    • /
    • 2021
  • PURPOSE. To characterize the microstructure of three yttria partially stabilized zirconia ceramics and to compare their hardness, indentation fracture resistance (IFR), biaxial flexural strength (BFS), and fatigue flexural strength. MATERIALS AND METHODS. Disc-shaped specimens were obtained from 3Y-TZP (Vita YZ HT), 4Y-PSZ (Vita YZ ST) and 5Y-PSZ (Vita YZ XT), following the ISO 6872/2015 guidelines for BFS testing (final dimensions of 12 mm in diameter, 0.7 and 1.2 ± 0.1 mm in thicknesses). Energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and scanning electron microscopy (SEM) analyses were performed, and mechanical properties were assessed by Vickers hardness, IFR, quasi-static BFS and fatigue tests. RESULTS. All ceramics showed similar chemical compositions, but mainly differed in the amount of yttria, which was higher as the amount of cubic phase in the diffractogram (5Y-PSZ > 4Y-PSZ > 3Y-TZP). The 4Y- and 5Y-PSZ specimens showed surface defects under SEM, while 3Y-TZP exhibited greater grain uniformity on the surface. 5Y-PSZ and 3Y-TZP presented the highest hardness values, while 3Y-TZP was higher than 4Y- and 5Y-PSZ with regard to the IFR. The 5Y-PSZ specimen (0.7 and 1.2 mm) showed the worst mechanical performance (fatigue BFS and cycles until failure), while 3Y-TZP and 4Y-PSZ presented statistically similar values, higher than 5Y-PSZ for both thicknesses (0.7 and 1.2 mm). Moreover, 3Y-TZP showed the highest (1.2 mm group) and the lowest (0.7 mm group) degradation percentage, and 5Y-PSZ had higher strength degradation than 4Y-PSZ group. CONCLUSION. Despite the microstructural differences, 4Y-PSZ and 3Y-TZP had similar fatigue behavior regardless of thickness. 5Y-PSZ had the lowest mechanical performance.