• 제목/요약/키워드: Advanced Dentistry

검색결과 1,057건 처리시간 0.025초

Effect of dentin treatment on proliferation and differentiation of human dental pulp stem cells

  • Park, Minjeong;Pang, Nan-Sim;Jung, Il-Young
    • Restorative Dentistry and Endodontics
    • /
    • 제40권4호
    • /
    • pp.290-298
    • /
    • 2015
  • Objectives: Sodium hypochlorite (NaOCl) is an excellent bactericidal agent, but it is detrimental to stem cell survival, whereas intracanal medicaments such as calcium hydroxide ($Ca[OH]_2$) promote the survival and proliferation of stem cells. This study evaluated the effect of sequential NaOCl and $Ca(OH)_2$ application on the attachment and differentiation of dental pulp stem cells (DPSCs). Materials and Methods: DPSCs were obtained from human third molars. All dentin specimens were treated with 5.25% NaOCl for 30 min. DPSCs were seeded on the dentin specimens and processed with additional 1 mg/mL $Ca(OH)_2$, 17% ethylenediaminetetraacetic acid (EDTA) treatment, file instrumentation, or a combination of these methods. After 7 day of culture, we examined DPSC morphology using scanning electron microscopy and determined the cell survival rate with 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay. We measured cell adhesion gene expression levels after 4 day of culture and odontogenic differentiation gene expression levels after 4 wk using quantitative real-time polymerase chain reaction. Results: DPSCs did not attach to the dentin in the NaOCl-treated group. The gene expression levels of fibronectin-1 and secreted phosphoprotein-1 gene in both the $Ca(OH)_2$- and the EDTA-treated groups were significantly higher than those in the other groups. All $Ca(OH)_2$-treated groups showed higher expression levels of dentin matrix protein-1 than that of the control. The dentin sialophosphoprotein level was significantly higher in the groups treated with both $Ca(OH)_2$ and EDTA. Conclusions: The application of $Ca(OH)_2$ and additional treatment such as EDTA or instrumentation promoted the attachment and differentiation of DPSCs after NaOCl treatment.

Wear of primary teeth caused by opposed all-ceramic or stainless steel crowns

  • Choi, Jae-Won;Bae, Ik-Hyun;Noh, Tae-Hwan;Ju, Sung-Won;Lee, Tae-Kyoung;Ahn, Jin-Soo;Jeong, Tae-Sung;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권1호
    • /
    • pp.43-52
    • /
    • 2016
  • PURPOSE. This study was conducted to evaluate the effects of full-coverage all-ceramic zirconia, lithium disilicate glass-ceramic, leucite glass-ceramic, or stainless steel crowns on antagonistic primary tooth wear. MATERIALS AND METHODS. There were four study groups: the stainless steel (Steel) group, the leucite glass-ceramic (Leucite) group, the lithium disilicate glass-ceramic (Lithium) group, and the monolithic zirconia (Zirconia) group. Ten flat crown specimens were prepared per group; opposing teeth were prepared using primary canines. A wear test was conducted over 100,000 chewing cycles using a dual-axis chewing simulator and a 50 N masticating force, and wear losses of antagonistic teeth and restorative materials were calculated using a three-dimensional profiling system and an electronic scale, respectively. Statistical significance was determined using One-way ANOVA and Tukey's test (P<.05). RESULTS. The Leucite group ($2.670{\pm}1.471mm^3$) showed the greatest amount of antagonist tooth wear, followed by in decreasing order by the Lithium ($2.042{\pm}0.696mm^3$), Zirconia ($1.426{\pm}0.477mm^3$), and Steel groups ($0.397{\pm}0.192mm^3$). Mean volume losses in the Leucite and Lithium groups were significantly greater than in the Steel group (P<.05). No significant difference was observed between mean volume losses in the Zirconia and Steel groups (P>.05). CONCLUSION. Leucite glass-ceramic and lithium disilicate glass-ceramic cause more primary tooth wear than stainless steel or zirconia.

Development of implant loading device for animal study about various loading protocol: a pilot study

  • Yoon, Joon-Ho;Park, Young-Bum;Cho, Yuna;Kim, Chang-Sung;Choi, Seong-Ho;Moon, Hong-Seok;Lee, Keun-Woo;Shim, June-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권4호
    • /
    • pp.227-234
    • /
    • 2012
  • PURPOSE. The aims of this pilot study were to introduce implant loading devices designed for animal study and to evaluate the validity of the load transmission ability of the loading devices. MATERIALS AND METHODS. Implant loading devices were specially designed and fabricated with two implant abutments and cast metal bars, and orthodontic expansion screw. In six Beagles, all premolars were extracted and two implants were placed in each side of the mandibles. The loading device was inserted two weeks after the implant placement. According to the loading protocol, the load was applied to the implants with different time and method, simulating early, progressive, and delayed loading. The implants were clinically evaluated and the loading devices were removed and replaced to the master cast, followed by stress-strain analysis. Descriptive statistics of remained strain (${\mu}{\varepsilon}$) was evaluated after repeating three cycles of the loading device activation. Statistic analysis was performed using nonparametric, independent t-test with 5% significance level and Friedman's test was also used for verification. RESULTS. The loading devices were in good action. However, four implants in three Beagles showed loss of osseointegration. In stress-strain analysis, loading devices showed similar amount of increase in the remained strain after applying 1-unit load for three times. CONCLUSION. Specialized design of the implant loading device was introduced. The loading device applied similar amount of loads near the implant after each 1-unit loading. However, the direction of the loads was not parallel to the long axis of the implants as predicted before the study.

Effect of different provisional cement remnant cleaning procedures including Er:YAG laser on shear bond strength of ceramics

  • Zortuk, Mustafa;Gumus, Hasan Onder;Kilinc, Halil Ibrahim;Tuncdemir, Ali Riza
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권4호
    • /
    • pp.192-196
    • /
    • 2012
  • PURPOSE. The purpose of this study was to evaluate the effect of provisional cement removal by different dentin cleaning protocols (dental explorer, pumice, cleaning bur, Er:YAG laser) on the shear bond strength between ceramic and dentin. MATERIALS AND METHODS. In total, 36 caries-free unrestored human third molars were selected as tooth specimens. Provisional restorations were fabricated and cemented with eugenol-free provisional cement. Then, disc-shaped ceramic specimens were fabricated and randomly assigned to four groups of dentin cleaning protocols (n = 9). Group 1 (control): Provisional cements were mechanically removed with a dental explorer. Group 2: The dentin surfaces were treated with a cleaning brush with pumice Group 3: The dentin surfaces were treated with a cleaning bur. Group 4: The provisional cements were removed by an Er:YAG laser. Self-adhesive luting cement was used to bond ceramic discs to dentin surfaces. Shear bond strength (SBS) was measured using a universal testing machine at a 0.05 mm/min crosshead speed. The data were analyzed using a Kolmogorov Smirnov, One-way ANOVA and Tukey HSD tests to perform multiple comparisons (${\alpha}$=0.05). RESULTS. The dentin cleaning methods did not significantly affect the SBS of ceramic discs to dentin as follows: dental explorer, pumice, cleaning bur, and Er:YAG laser. CONCLUSION. The use of different cleaning protocols did not affect the SBS between dentin and ceramic surfaces.

임플란트 수술 시 통증에 영향을 주는 요인에 관한 평가 (Contributing factors related to patients' pain on implant surgery)

  • 김용태;박정철;윤정호;정의원;김창성;조규성;채중규;최성호
    • 대한치과의사협회지
    • /
    • 제49권2호
    • /
    • pp.95-103
    • /
    • 2011
  • Purpose : The purpose of this study was to identify and assess factors that may contribute to pain of patients undergoing implant surgery. Materials and Methods: A total of 24 patients who underwent implant surgery were included in the study. Each patient's anxiety was measured using Corah's dental anxiety score(DAS) and modified Spielberger's state-trait anxiety inventory(STAI) immediately after the operation. Also, level of pain was measured using visual analog scale(VAS) during the operation and 48 hours after the surgery. The effect of various factors, such as demographic variables, previous dental experiences and operation time were also analyzed. Results: Postoperative pain levels were relatively low than expected. However, DAS and STAI were high among patients, and it showed that patients had anxieties about implant surgery according to DAS and STAI values. The previous dental experience did not affect the pain level, but the duration of surgery and the presence of accompanied advanced surgery did. Conclusion: To reduce patient's pain, proper management of anxiety will be required and careful attention is needed when performing local infiltration.

Obstructive Sialadenitis associated with Injectable Facial Fillers

  • Kim, Sora;Hong, Youree;Kim, Bokeum;Park, YounJung;Ahn, Hyung-Joon;Kim, Seong-Taek;Choi, Jong-Hoon;Kwon, Jeong-Seung
    • Journal of Oral Medicine and Pain
    • /
    • 제47권3호
    • /
    • pp.148-151
    • /
    • 2022
  • Obstructive sialadenitis, one of the diseases that most frequently causes swelling and pain in the salivary glands, is mainly caused by structural obstructions. Sialolithiasis is the most frequent cause of the disease, and other causes include calculus formation, duct strictures, foreign bodies, and anatomical variations. Although there is a possibility that facial fillers directly block the salivary ducts, no cases of obstructive sialadenitis associated with them have been reported yet. We report the case of a 34-year-old female patient who complained of recurrent swelling and pain in the left buccal mucosa. She had undergone facial filler injection procedures on her facial area for cosmetic purposes several years before. Based on the findings of magnetic resonance imaging (MRI) and MR sialography, she was diagnosed with obstructive sialadenitis due to facial fillers. Through this case, we should remember to obtain a thorough history including filler treatments in the case of parotid gland swelling. We also suggest proper utilization of advanced imaging such as MRI in evaluating the location of facial fillers.

Accuracy and time efficiency of conventional and digital outlining of extensions of denture foundation on preliminary casts

  • Anne Kaline Claudino Ribeiro;Aretha Heitor Verissimo;Rodrigo Falcao Carvalho Porto de Freitas;Rayanna Thayse Florencio Costa;Burak Yilmaz;Sandra Lucia Dantas de Moraes;Adriana da Fonte Porto Carreiro
    • The Journal of Advanced Prosthodontics
    • /
    • 제16권3호
    • /
    • pp.139-150
    • /
    • 2024
  • PURPOSE. The purpose of this diagnostic study was to assess the accuracy and time efficiency of a digital method to draw the denture foundation extension outline on preliminary casts compared with the conventional technique. MATERIALS AND METHODS. A total of 28 preliminary edentulous casts with no anatomical landmarks were digitized using a laboratory scanner. The outlining of the entire basal seat of the denture was performed on preliminary casts and digitized. Casts with no extension outline were digitized and outlines were drawn using software (DWOS, Straumann). The accuracy of the extension outlined between both techniques was evaluated in the software (GOM Inspect; GOM GmbH) by file superimposition. Specificity and sensitivity tests were applied to measure accuracy. The paired t-test (95% CI) was used to compare the mean total area and the working time. RESULTS. The accuracy ranged from 0.57 to 0.92. The buccal and labial frenulum showed a lower value in the maxilla (0.57); while the area between the retromolar pad and buccal frenulum (0.64) showed a lower score in the mandible. The maxillary denture foundation and the working time for both arches were significantly longer for the digital method (P < .001). CONCLUSION. The denture foundation extension outline exhibited a sufficiently excellent accuracy for the digital method, except for the maxillary anterior region. However, the digital method required a longer working time.

두경부에 발생한 편평상피세포암의 항암제 치료후 조직반응에 관한 연구 : COB Regimen (HISTOPATHOLOGICAL CHANGE AFTER CHEMOTHERAPY OF SQUAMOUS CELL CARCINOMA IN HEAD AND NECK : COB REGIMEN)

  • 김영균;여환호;조재오
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제15권2호
    • /
    • pp.147-155
    • /
    • 1993
  • The combined induction chemotherapy is usually used to treat the advanced head and neck cancer. In particular, it is considered that the COB(Cisplatin, Oncovin, Bleomycin)regimen is very effective against the squamous cell carcinoma in head and neck region. The purpose of this study is to evaluate the cancer tissue response to chemotherapy (COB Regimen) histopath ologically.

  • PDF

Comparison of light transmittance in different thicknesses of zirconia under various light curing units

  • Cekic-Nagas, Isil;Egilmez, Ferhan;Ergun, Gulfem
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권2호
    • /
    • pp.93-96
    • /
    • 2012
  • PURPOSE. The objective of this study was to compare the light transmittance of zirconia in different thicknesses using various light curing units. MATERIALS AND METHODS. A total of 21 disc-shaped zirconia specimens (5 mm in diameter) in different thicknesses (0.3, 0.5 and 0.8 mm) were prepared. The light transmittance of the specimens under three different light-curing units (quartz tungsten halogen, light-emitting diodes and plasma arc) was compared by using a hand-held radiometer. Statistical significance was determined using two-way ANOVA (${\alpha}$=.05). RESULTS. ANOVA revealed that thickness of zirconia and light curing unit had significant effects on light transmittance ($P$ <.001). CONCLUSION. Greater thickness of zirconia results in lower light transmittance. Light-emitting diodes light-curing units might be considered as effective as Plasma arc light-curing units or more effective than Quartz-tungsten-halogen light-curing units for polymerization of the resin-based materials.

Dental treatment in patients with severe gag reflex using propofol-remifentanil intravenous sedation

  • Shin, Sooil;Kim, Seungoh
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제17권1호
    • /
    • pp.65-69
    • /
    • 2017
  • Patients with severe gag reflex (SGR) have difficulty getting the treatment they require in local clinics, and many tend to postpone the start of their treatment. To address this problem, dentists have used behavioral techniques and/or pharmacological techniques for treatment. Among the pharmacological methods available, propofol IV sedation is preferred over general anesthesia because it is a simpler procedure. Propofol in combination with remifentanil is characterized by stable sedative effects and quick recovery, leading to a deep sedation. Remifentanil acts to reduce the pain caused by lipid-soluble propofol on injection. The synergistic effects of propofol-remifentanil include reduction in the total amount of drug required to achieve a desired sedation level and anti-emetic effects. In this case report, we outline how the use of propofol-remifentanil IV sedation enabled us to successfully complete a wide range of dental treatments in a patient with SGR.