• Title/Summary/Keyword: Adsorber

Search Result 48, Processing Time 0.036 seconds

Adsorption Characteristics of Malachite Green on Zeolite (제올라이트에 의한 말라카이트 그린의 흡착특성)

  • Lee, Jong-Jib;Um, Myeong-Heon
    • Clean Technology
    • /
    • v.18 no.3
    • /
    • pp.312-319
    • /
    • 2012
  • Malachite green is used a dye but malachite green is harmful toxic substance. In this study, the adsorption characteristics of zeolite has been investigated for the adsorption of malachite green dissolved in water. The effects of initial dye concentration, contact time, pH and temperature on adsorption of malachite green by a fixed amount of zeolite have been studied in batch adsorber and fixed bed. The adsorption equilibrium data are successfully fitted to the Freundlich isotherm equation in the temperature range from 25 to $45^{\circ}C$. The estimated values of k and ${\beta}$ are 23.60-46.88, 0.225-0.347, respectively. The mechanism of the adsorption process was determined from the intraparticle diffusion model. The effects of the operation conditions of the fixed bed on the breakthrough curve were investigated. When the inlet concentration and initial flow rate of malachite green are increased, the corresponding adsorption breaktime appears to decrease. Breaktime increased with increasing bed height and length of adsorption zone showed similar patterns.

Competitive Adsorption for Binary Mixture of 4-Nitrophenol and Phenol on RSTA using GAC (GAC를 이용한 RSTA에서 Phenol과 4-Nitrophenol의 이성분계 경쟁흡착)

  • Lee, Seung-Mok;Kim, Dae-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.723-731
    • /
    • 2000
  • In recent years, the amount and number of synthetic organic compounds(SOCs) discharged from various industries has been increasing. Granular activated carbon(GAC) adsorption is one of the best available technology to remove SOCs from water supplies and wastewater. In this paper competitive adsorption for binary mixture of 4-nitrophenol and phenol on reverse stratified tapered adsorber(RSTA) using GAC was studied. Two isotherm experiments were conducted, one for phenol and the other for 4-nitrophenol. The phenol data of binary mixture isotherm were not fitted to Freundlich isotherm. The competitive adsorption increased significantly with decreasing carbon dose and increasing adsorbate concentration. The RSTA was found to provide an increase in breakthrough time when decreasing flow rate, increasing angle and injection layers. The performance enhancement provided by RSTA can be exploited in separation and in the purification of fluids.

  • PDF

An Experimental Study on the Heat and Mass Transfer of Adsorption Chiller (흡착식 냉동기의 열 및 물질전달에 관한 실험적 연구)

  • Kwon Oh-Kyung;Yun Jae-Ho;Joo Young-Ju;Kim Yong-Chan;Kim Joung-Ha
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.746-753
    • /
    • 2005
  • Adsorption chillers have been receiving considerable attentions as they are energy-saving and environmentally benign systems. In order to evaluate adsorption rates, experiments were performed in the batch type adsorption apparatus. Three types of silica gels were investigated under an assortment of experimental conditions that are representatives of the actual operating environments in the adsorber of adsorption chillers. Experimental results revealed the effects of silica gel particle size, bed temperature, and fin pitch of fin tube on the adsorption rate. The $0.25\~1.18mm$ particle size of silica gel with high adsorption rate was selected as a suitable adsorbent. The measured adsorption rate became bigger with decreasing particle size. From the comparison of adsorption rate, it is found that the fin tube has about $21\%$ higher value than that of the bare tube. The effect of heat and mass flux is found to be more significant in the fin tube than in the bare tube.

Removal Charateristics of Erythrosine by Activated Carbon Adsorption (활성탄 흡착에 의한 Erythrosine의 제거 특성)

  • Lee, Jong-Jib;Yoon, Sung-Wook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.499-504
    • /
    • 2009
  • Erythrosine is used a food coloring, ink and dye, etc. but erithrosine is rarely used in United States due to its known hazards. The adsorption characteristics of erythrosine by granular activated carbon were investigated in the batch adsorber and the packed column. The adsorptivity of activated carbon for erythrosine were largely improved by pH control. When the pH was 11 in the sample, the erythrosine could be removed 98% of initial concentration. It was estabilished that the adsorption equilibrium of erythrosine on granular activated carbon was successfully fitted by Freundlich isotherm equation in the concentration range from 10mg/L to 1,000mg/L. The characteristics of breakthrough curve of activated carbon packed column depend on the design variables such as initial concentration, bed height, and flow rate.

Removal of Quinoline Yellow by Granular Activated Carbon (입상 활성탄에 의한 Quinoline Yellow의 제거)

  • Lee, Jong-Jib;Lee, Chang-Yong
    • Clean Technology
    • /
    • v.16 no.3
    • /
    • pp.206-212
    • /
    • 2010
  • The adsorption characteristics of quinoline yellow by granular activated carbon were investigated experimently in the batch adsorber and packed column. The adsorptivity of activated carbon for quinoline yellow were largely improved by acidic pH and higher temperature. When the pH was 3 at $60^{\circ}C$, quinoline yellowcould be removed 97 percent of initial concentration(10 mg/L). It was estabilished that the adsorption equilibrium of quinoline yellow on granular activated carbon was successfully fitted by Freundlich isotherm equation in the temperature range from $25^{\circ}C$ to $60^{\circ}C$. The estimated values of k and ${\beta}$ are 38.71~166.60, 0.380~0.490, respectively. The breakthrough curve of activated carbon-packed column depends on the design variables such as initial concentration, bed height, and flow rate.

Adsorption Removal of Eosin Y by Granular Activated Carbon (입자상 활성탄에 의한 Eosin Y의 홉착제거)

  • Lee, Jong-Jib
    • Clean Technology
    • /
    • v.16 no.4
    • /
    • pp.277-283
    • /
    • 2010
  • Eosin Y is used a colorant and dye but eosin Y is harmful toxic substance. In this study, the adsorption characteristics of granular activated carbon have been investigated for the adsorption of eosin dye dissolved in water. The effects of initial dye concentration, contact time, pH and temperature on adsorption of eosin by a fixed amount of activated carbon have been studied in batch adsorber and fixed bed. The adsorptivity of activated carbon for eosin Y were largely improved by pH control. When the pH was 3 in the sample, the eosin Y could be removed 99% of initial concentration (10 mg/L). The adsorption equilibrium data are successfully fitted to the Freundlich isotherm equation in the temperature range from 293 to 333 K. The estimated values of k and ${\beta}$ are 19.56-134.62, 0.442-0.678, respectively. The effects of the operation conditions of the fixed bed on the breakthrough curve were investigated. When the inlet eosin Y concentration is increased from 10 to 30 mg/L, the corresponding adsorption breaktime appears to decrease from 470 to 268 min at bed height of 3 cm and a constant flow rate of 2 g/min. When the initial eosin Y flow rate is increased from 1 to 3 g/min, the corresponding adsorption breaktime appears to decrease from 272 to 140 min at bed height of 3 cm and inlet concentration of 10 mg/L. Also, breaktime increased with increasing bed height at flow rate of 2 g/min and inlet concentration of 10 mg/L. And length of adsorption zone showed similar patterns.

A Study on Construction and Application of Nuclear Grade ESF ACS Simulator (원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kei-Woo;Park, Jeong-Seo;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.319-327
    • /
    • 2010
  • A nuclear plant ESF ACS simulator was designed, built, and verified to perform experiment related to ESF ACS of nuclear power plants. The dimension of 3D CAD model was based on drawings of the main control room(MCR) of Yonggwang units 5 and 6. The CFD analysis was performed based on the measurement of the actual flow rate of ESF ACS. The air flowing in ACS was assumed to have $30^{\circ}C$ and uniform flow. The flow rate across the HEPA filter was estimated to be 1.83 m/s based on the MCR ACS flow rate of 12,986 CFM and HEPA filter area of 9 filters having effective area of $610{\times}610mm^2$ each. When MCR ACS was modeled, air flow blocking filter frames were considered for better simulation of the real ACS. In CFD analysis, the air flow rate in the lower part of the active carbon adsorber was simulated separately at higher than 7 m/s to reflect the measured value of 8 m/s. Through the CFD analyses of the ACSes of fuel building emergency ventilation system, emergency core cooling system equipment room ventilation cleanup system, it was confirmed that all three EFS ACSes can be simulated by controlling the flow rate of the simulator. After the CFD analysis, the simulator was built in nuclear grade and its reliability was verified through air flow distribution tests before it was used in main tests. The verification result showed that distribution of the internal flow was uniform except near the filter frames when medium filter was installed. The simulator was used in the tests to confirm the revised contents in Reg. Guide 1.52 (Rev. 3).

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.