• Title/Summary/Keyword: Adjusting p-value

Search Result 83, Processing Time 0.03 seconds

Introduction of Corrosion Index System for Stability of Drinking Water Quality (음용수질의 안정성을 위한 부식지수제도의 도입)

  • Kim, Yeong-Kwan;Kim, Jin-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.5
    • /
    • pp.707-717
    • /
    • 2011
  • Replacement of old water distribution pipes for protecting water quality induced by pipe corrosion requires enormous budget. Even after the replacement, however, corrosion can occur again at any times and, therefore, inhibitive measure of the corrosion will be not only economical but needed to diminish the consumers' distrust on tap water quality. In 2008, National Environmental Research Institute did a survey on 8 major drinking water source and proposed to establish the Langelier Saturation Index(LI) as a corrosion index in Drinking Water Quality Criteria. Among the water industries of Korea, K-Water is the only one that set up the level of pH over 7.0 and LI above -1.5 on yearly average basis. However, no systematic regulation including LI to inhibit the corrosive tendency has been established yet. In this paper, LI values out of 31 drinking water treatment plants were analyzed and two-stage control of LI value as a measure of corrosive tendency of water is proposed. Primarily, water treatment facilities may operate the system at a target LI value below -1.5. Following the investigation on the effect caused by adjusting the LI value on water quality and corrosiveness, it will be desirable to improve LI value below -1.0 in the long run. In addition to the LI, supplemental use of Larson's modified ratio (LMR) which incorporates hydraulic detention time will be necessary. Several methods to prove the inhibitive effect of improving the LI value on water quality have been also suggested.

The Study on Arc Suppression of Line-to-Line Electrodes in Air and Removal of the Metaloxide (선대 선 전극방식의 대기압 아크억제 대책 및 Metaloxide 제거에 관한 연구)

  • 정종한;김문환
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.264-267
    • /
    • 2004
  • Recently the pulsed power systems have been widely used in many fields such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power systems, ozone generators and power sources of the laser beam. In this paper, we studied various electrical characteristics for arc suppression of line-to-line electrodes in air and removal of the metaloxide using our pulsed power system. To obtain high efficiency of the pulsed power system, we repeatedly experimented and tested their characteristics. by adjusting electrode length of the load. As a result, when the value of the electrode length and pulse repetition rate were changed at the load, the value of the arc voltage changed at the electrode load. In conclusion, we controlled arc voltage of the load by ,changing electrode length and pulse repetition rate. Also. we stydied removal area of the metaloxide using area discharge according to pulse repetition rate.

Morphology and Formation Mechanism of Sn Nanoparticles Synthesized by Modified Polyol Process at Various pH Values (변형 폴리올 공정에서 pH에 따라 합성된 Sn 나노입자의 형상 변화 및 형성기구)

  • Shin, Yong Moo;Lee, Jong-Hyun
    • Korean Journal of Materials Research
    • /
    • v.24 no.11
    • /
    • pp.578-584
    • /
    • 2014
  • To synthesize Sn nanoparticles (NPs) less than 30 nm in diameter, a modified polyol process was conducted at room temperature using a reducing agent, and the effects of different pH values of the initial solutions on the morphology and size of the synthesized Sn NPs were analyzed. tin(II) 2-ethylhexanoate, diethylene glycol, sodium borohydride, polyvinyl pyrrolidone (PVP), and sodium hydroxide were used as a precursor, reaction medium, reducing agent, capping agent, and pH adjusting agent, respectively. It was found by transmission electron microscopy that the morphology of the synthesized Sn NPs varied according to the pH of the initial solution. Moreover, while the size decreased to 11.32 nm with an increase up to 11.66 of the pH value, the size increased rapidly to 39.25 nm with an increase to 12.69. The pH increase up to 11.66 dominantly promoted generation of electrons and increased the amount of initial nucleation in the solution, finally inducing the reduced-size of the Sn particles. However, the additional increase of pH dominantly induced a decrease of PVP by neutralization, which resulted in acceleration of the agglomeration by collisions between particles.

Prognostic Implication of Right Ventricle Parameters Measured on Preoperative Cardiac MRI in Patients with Functional Tricuspid Regurgitation

  • Yura Ahn;Hyun Jung Koo;Joon-Won Kang;Won Jin Choi;Dae-Hee Kim;Jong-Min Song;Duk-Hyun Kang;Jae-Kwan Song;Joon Bum Kim;Sung-Ho Jung;Suk Jung Choo;Cheol Hyun Chung;Jae Won Lee;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1253-1265
    • /
    • 2021
  • Objective: To investigate the prognostic value of preoperative cardiac magnetic resonance imaging (MRI) for long-term major adverse cardiac and cerebrovascular events (MACCEs) in patients undergoing tricuspid valve (TV) surgery for functional tricuspid regurgitation (TR). Materials and Methods: The preoperative cardiac MR images, New York Heart Association functional class, comorbidities, and clinical events of 78 patients (median [interquartile range], 59 [51-66.3] years, 28.2% male) who underwent TV surgery for functional TR were comprehensively reviewed. Cox proportional hazards analyses were performed to assess the associations of clinical and imaging parameters with MACCEs and all-cause mortality. Results: For the median follow-up duration of 5.4 years (interquartile range, 1.2-6.6), MACCEs and all-cause mortality were 51.3% and 23.1%, respectively. The right ventricular (RV) end-systolic volume index (ESVI) and the systolic RV mass index (RVMI) were higher in patients with MACCEs than those without them (77 vs. 68 mL/m2, p = 0.048; 23.5 vs. 18.0%, p = 0.011, respectively). A high RV ESVI was associated with all-cause mortality (hazard ratio [HR] per value of 10 higher ESVI = 1.10, p = 0.03). A high RVMI was also associated with all-cause mortality (HR per increase of 5 mL/m2 RVMI = 1.75, p < 0.001). After adjusting for age and sex, only RVMI remained a significant predictor of MACCEs and all-cause mortality (p < 0.05 for both). After adjusting for multiple clinical variables, RVMI remained significantly associated with all-cause mortality (p = 0.005). Conclusion: RVMI measured on preoperative cardiac MRI was an independent predictor of long-term outcomes in patients who underwent TV surgery for functional TR.

Relationship Between Serum Concentrations of Organochlorine Pesticides and Metabolic Syndrome Among Non-Diabetic Adults

  • Park, Sun-Kyun;Son, Hyo-Kyung;Lee, Sung-Kook;Kang, Jung-Ho;Chang, Yoon-Seok;Jacobs, David R. Jr.;Lee, Duk-Hee
    • Journal of Preventive Medicine and Public Health
    • /
    • v.43 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • Objectives: This study was performed to investigate if organochlorine pesticides (OCPs) were associated with metabolic syndrome and insulin resistance among non-diabetes. Methods: Among subjects who participated in a community-based health survey, 50 non-diabetic subjects with metabolic syndrome and 50 normal controls were selected. Insulin resistance was measured by the homeostasis model assessment (HOMA-IR). Eight OCPs were selected. Results: After adjusting for confounders except for body mass index (BMI), beta-hexachlorocyclohexane ($\beta$-HCH) and heptachlor epoxide were positively associated with metabolic syndrome. Odds ratios across tertiles of $\beta$-HCH and heptachlor epoxide were 1.0, 3.2 and 4.4, and 1.0, 4.0 and 6.0, respectively (p for trend = 0.01 and <0.01). After additional adjustment for body mass index (BMI), heptachlor epoxide still showed an increasing trend with adjusted odds ratios of 1.0, 4.1, and 4.6 (p for trend = 0.10). When the five components of metabolic syndrome (with the definition of high fasting glucose ($\geq$ 100 mg/dL) were separately analyzed, all components were positively, but not significantly, associated with heptachlor epoxide. As the serum concentration of heptachlor epoxide increased, HOMA-IR increased significantly in subjects with metabolic syndrome even after adjusting for BMI (p value <0.05 and <0.01). Conclusions: Despite the small sample size, this study suggests that the background exposure to some OCPs may be associated with metabolic syndrome.

Biological Hydrogen Production from Mixed Waste of Food and Activated Sludge (음식물쓰레기와 폐활성슬러지의 혼합물로부터 혐기성 바이오 수소 생산)

  • Chung, Chong Min;Hong, Seok Won;Park, Chul Hee;Kim, Young O;Lee, Sang Hyup
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.5
    • /
    • pp.571-580
    • /
    • 2008
  • The influence of bacterial stress on anaerobic hydrogen-producing microorganisms was investigated in batch tests using serum bottles. Several physical and chemical stresses (i.e., heating, adding methane producing inhibitor and chemical acidification) were adapted as a pretreament of the seed sludge. In this experiment, the cultivation temperature were set at mesophilic ($35^{\circ}C$) and thermophilic conditions ($55^{\circ}C$) with adjusting pH at 5, 6, and 7 when using the mixture of food waste and activated sludge as a substrate. In conjunction with the pretreatment, hydrogen production was significantly enhanced as compared with that from untreated sludge. However, less biogas (hydrogen and methane) was produced without the pH control, resulted from the decrease of pH to below 4, mainly due to the formation of VFAs. Hydrogen and carbon dioxide gas were analyzed as main components of the biogas while methane not detected. With an application of chemical acidification, the highest hydrogen production value of 248 ml/l/day achieved at pH 7 and $35^{\circ}C$. In addition, more hydrogen gas produced when the ratio of butyric/acetic acid ratio increased. The optimum pH and temperature for hydrogen production were found to be 7 and $35^{\circ}C$, respectively.

Solid Circulation Rate in a 3-phase (gas/liquid/solid) Viscous Circulating Fluidized Bed

  • Jang, Hyung Ryun;Yoon, Hyuen Min;Yang, Si Woo;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.56 no.2
    • /
    • pp.186-190
    • /
    • 2018
  • For the first time, the characteristics of solid circulation rate ($G_S$) were investigated in a three-phase (gas-liquid-solid) viscous circulating fluidized bed (TPCFB). The solid circulation rate was controlled separately by adjusting the experimental apparatus as well as operating variables. Effects of primary and secondary liquid velocities ($U_{L1}$ and $U_{L2}$), gas velocity ($U_G$), particle size ($d_p$), height of particles piled up in the solid recycle device (h), and viscosity of continuous liquid media (${\mu}_L$) on the value of $G_S$ were determined. The experimental results showed that the value of $G_S$ increased with increases in the values of $U_{L1}$, $U_{L2}$, h and ${\mu}_L$, while it decreased with increasing $U_G$ and $d_p$ in TPCFBs with viscous liquid media. The values of $G_S$ were well correlated in terms of dimensionless groups within this experimental conditions.

Effects of Factors Associated with Urine Hippuric Acid Correction Values in Urinary Creatinine by HPLC and Jaffe Method and Specific Gravity HPLC Jaffe Method (HPLC와 Jaffe method의 요중 크레아티닌 및 비중이 마뇨산 보정값에 미치는 요인에 관한 연구)

  • Kim, Key-Young;Kim, Jong-Gyu;Yoon, Ki-Nam;Park, Wha-Me;Park, Hun-Hee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.493-505
    • /
    • 2015
  • Objectives: The purpose of this study was to evaluate the relevance of adjusting a urinary sample for urine hippuric correction value and its effects. Urinary biological monitoring data are typically adjusted to a constant creatinine and specific gravity concentration to correct for variable dilutions among spot samples. This study was conducted to evaluate the suitability of adjusting the urinary concentrations of urine creatinine and specific gravity(SG). Methods: We measured the concentrations of hippuric acid, in spot urine samples collected from control(119), case(120) individuals. The value of hippuric acid was adjusted by SG and urinary creatinine(HPLC & Jaffe). Results: The major results were as follows. The concentrations of urinary creatinine and SG for the control group were 1.84 g/L(SD 0.99) for arithmetic mean and 1.56 g/L(GSD 1.86) for geometric mean by HPLC method, 1.57 g/L (SD, 0.82) for arithmetic mean and 1.33 g/L(GSD 1.85) for geometric mean by Jaffe method, 1.028(SD 0.09) for arithmetic mean and 1.02(GSD 1.06) for geometric mean by refractometer. Hippuric acid levels were 0.40 g/L(SD 0.51) by arithmetic mean and 0.20 g/L(GSD 3.59). In that case the exposed group was 1.40 g/L(SD 0.58) for arithmetic mean and 1.28 g/L(GSD 1.55) for geometric mean by HPLC method, 1.27 g/L(SD 0.56) for arithmetic mean and 1.14 g/L(GSD 1.62) for geometric mean by Jaffe method, 1.045 L(SD 0.27) for arithmetic mean and 1.02(GSD 1.13) for geometric mean by refractometer(P<0.05). Hippuric acid levels were 0.67 g/L(SD 0.79) for arithmetic mean and 0.39 g/L(GSD 2.94)(p<0.05). The urine creatinine concentrations were affected by gender(p < 0.01) but SG levels were not affected by gender or age(p>0.05). After adjustment, urine hippuric acid was correlated with creatinine(HPLC & Jaffe)(r=0.723, P<0.05, r=0.708, P<0.05) and SG(r=0.936, P<0.05) and the control group shows significantly higher than the case group. In the case group for adjusted urine hippuric acid was correlated with creatinine(HPLC & Jaffe), (r=0.736, P<0.05), r=0.549, P<0.05), SG(r=0.549, P<0.05). After adjusting urine hippuric acid by urine creatinine(HPLC and Jaffe method) and specific gravity, significant associations were found between the control group and case group, respectively(r=0.832, P<0.05, r=0.845, P<0.05) and (r=0.841, P<0.05, r=0.849, P<0.05). Specific gravity adjustment appears to be more appropriate for variations in the urine creatinine method. Conclusion: we found that urinary creatinine concentrations were significantly affected by gender, and other factors and that care should therefore be exercised when correcting urinary metabolites according to the urinary creatinine concentration in spot urine. It is determined that additional study is needed for biological monitoring.

Trends of Tongue Features in Functional Dyspepsia Patients (기능성 소화불량 환자에서 설 지표의 경향성 파악)

  • Kim, Jihye;Ko, Seok-jae;Park, Jae-woo;Kim, Keun Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.39 no.4
    • /
    • pp.637-644
    • /
    • 2018
  • Objectives: In this study, the tongue features of patients with functional dyspepsia (FD) were compared with those of healthy controls. Methods: This prospective, case-control study was conducted on patients with FD and controls recruited at a single center. After screening, the subjects were allocated to the patient or control groups (patients=42, controls=40). Tongue images were acquired using a computerized tongue image acquisition system (CTIS). An independent t-test was conducted to compare the measurements from patients and controls. Binary logistic regression was performed to determine significant differences between the two groups after adjusting for age and sex. Results: The CIE $a^*$ color value in the tongue coating area was significantly lower in the patients with FD than in the controls (p=0.001). The tongue coating ratios were also significantly higher in the FD group than in the control group (p=0.003). We found that the CIE $a^*$ color value in the tongue coating area and the tongue coating ratios were significant predictive factors in both groups, based on binary regression analysis (p=0.016, 0.044, respectively). Conclusions: This study found that FD was significantly associated with CIE $a^*$ color value in the tongue coating area and tongue coating ratios. We suggest that these factors could be used as objective indicators of FD.

Landfill Leachate Treatment and Boron Removal by Reverse Osmosis (RO막을 이용한 매립지 침출수 처리 및 붕소 제거)

  • Jung, Soojung;Na, Sukhyun;Bae, Sangok;Lim, Byungjin
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.657-662
    • /
    • 2012
  • This study was carried out to evaluate the removal rate of organic and inorganic matters from landfill leachate using pre-treatment process as coagulation and limonite adsorption, and membrane process as RO (reverse osmosis) and NF(nanofiltration). By adding limonite adsorption as pre-treatment process, about 40% of organic matters in leachate was removed through pre-treatment process and 74.7% of boron was removed after RO process without pH adjustment. The rejection rate of boron in RO process mainly depends on the pH and increased at pH value of 10. RO process was performed as two stage system adjusting pH condtion to 7 and 10 in second RO stage for boron removal. Most (>90%) of TOC, Cl- and inorganic matters as Ca was rejected in first RO stage, the residue was rejected in second RO and the rejection rate was above 97%. Considering economic efficiency of operation cost, NF substituted for the first RO and total removal rate of TOC was above 90%. Through RO system toxicity to Daphnia in leachate was removed completely.