• Title/Summary/Keyword: Adjusting

Search Result 4,385, Processing Time 0.029 seconds

A Study on the Adjustment Method of Bicycle Shoe Cleat for Bicycle Fitting System

  • Shon, Gyoung-Hoan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.5
    • /
    • pp.93-102
    • /
    • 2019
  • The nation's fraternity and elite players who have built up a global bicycle infrastructure often find it to be a problem with the bicycle's speed and speed reduction, pain in knees and hip joints, or even with the bike itself, or with the bike's own physical defects or a riding posture. However, we found that most cases of cleat adjustment errors were likely to be true. Accurate adjustment of the cleats is the most important of the entire fitting process and can be the basis for improving the ability of the bicycle rider and preventing injury. Therefore, the study was intended to give a prior study of bicycle fitting, which can improve bicycle efficiency and prevent injury when riding bicycle, and specific ways of adjusting bicycle shoe cleats, and the following results were obtained. First, the cleat characteristics of Shimano, LOOK and Speedplay, which are currently used in public, and the characteristics during the cleat adjustment process, were derived. In addition, the structure and characteristics of dedicated shoes using cleats and the method of using pedalling by the structure of shoes after adjusting the cleats were derived. Second, the position of the shoe and its relationship with torque in pedalling was discussed, and the method of adjusting front and back of cleats was derived. Third, leg length, ASIS, Q-Angle and Q-factor etc. were analyzed and the method of setting and adjusting cleat left and right values were derived. Fourth, the relationship between walking angle and cleat rotation was analyzed, the method was derived, and the torque size and angle behind the cleat adjustment were compared and analyzed using the spinner to indicate the torque and the effective mean torque angle after the cleat adjustment.

A method for automatically adjusting threshold to improve the intercept pulse detection performance of submarine (잠수함의 방수펄스탐지 성능 향상을 위한 문턱값 자동 조절 방법)

  • Kim, Do-Young;Shin, Kee-Cheol;Eom, Min-Jeong;Kwon, Sung-Chur
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.4
    • /
    • pp.213-219
    • /
    • 2021
  • The submarine's intercept pulse detection detects pulses radiated from enemy surface ships, submarines, and torpedoes, and performs an important function of providing maneuverability and survivability of submarine. Whether or not the intercept pulse is detected is determined by comparing the size of the received pulse with the threshold value by the operator. In the case of intercept pulses, the intensity of the pulses is frequently reduced under the influence of various environmental factors. In the situation, if detection is performed with a fixed threshold, a non-detection problem occurs and persists until the operator sets a low threshold. In this paper, we proposed method for automatically adjusting threshold to reduce the non-detection problem caused by a fixed threshold. Simulation were preformed on 4 cases with different pulse level fluctuation widths, and it was confirmed that the detection performance was improved by increasing the number of detections when a method for automatically adjusting threshold was applied to all cases. Through the proposed method, it is expected that the intercept pulse detection performance will be improved in the marine environment the large fluctuations in pulse level in the future.

Radiation Dose Reduction of Lens by Adjusting Table Height and Magnification Ratio in 3D Cerebral Angiography (삼차원 뇌혈관조영술에서 테이블 높이와 확대율 조절에 따른 수정체 선량 감소에 대한 연구)

  • Yoon, Jong-Tae;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.313-320
    • /
    • 2022
  • Both angiography and interventional procedures accompanied by angiography provide many diagnostic and therapeutic benefits to patients and are rapidly increasing. However, unlike general radiography or computed tomography using the same X-ray, the amount of radiation is quite high, but the dose range can vary considerably for each patient and operator. The high sensitivity of the lens to radiation during cerebral angiography and neurointervention is already well known, and although there are many related studies, it is insufficient to easily reduce radiation in diagnosis and treatment. In this situation, in particular, by adding three-dimensional rotational angiography (3D-RA) to the existing two-dimensional (2D) angiography, it is now possible to make an accurate diagnosis. However, since this 3D-RA acquires images through projection of more radiation than before, the exposure dose of the lens may be higher. Therefore, we tried to analyze whether the radiation dose of the lens can be reduced by moving the lens out of the field range by adjusting the table height and magnification ratio during the examination using 3D-RA. The surface dose was measured using a rando phantom and a radiophotoluminescent glass dosimeter (PLD) and the radiation dose was compared by adjusting the table height and magnification ratio based on the central point. As a result, it was found that the radiation dose of the lens decreased as the table height increased from the central point, that is, as the lens was out of the field of view. In conclusion, in 3D-RA, moving the table position of about 2 cm in height will make a significant contribution to the dose reduction of the lens, and it was confirmed that adjusting the magnification ratio can also reduce the surface dose of the lens.

Association of diet quality score with the risk of mild cognitive impairment in the elderly

  • Kim, Eunbin;Choi, Bo Youl;Kim, Mi Kyung;Yang, Yoon Jung
    • Nutrition Research and Practice
    • /
    • v.16 no.5
    • /
    • pp.673-684
    • /
    • 2022
  • BACKGROUND/OBJECTIVES: Although adherence to a higher diet quality may help prevent cognitive decline in older adults, literature for this in a Korean population is limited. Thus, the aim of this study was to examine the association between diet quality indices and the risk of mild cognitive impairment (MCI) in Korean older adults. SUBJECTS/METHODS: This cross-sectional study included 806 community-dwelling people aged 60 yrs and over in Korea. Diet quality was assessed via the revised Recommended Food Score (RFS) and alternate Mediterranean Diet Score (aMDS). Cognitive function was measured using a Korean version of the Mini-Mental State Examination (MMSE-KC). Associations between diet quality indices and MMSE-KC score were assessed with a general linear model after adjusting for covariates. Logistic regression was used to determine the association between diet quality indices and the risk of MCI. RESULTS: The prevalence of MCI was 35.3%. There were no significant trends between MMSE-KC scores and RFS and aMDS after adjusting for age, gender, education, exercise, living status, social activity, and alcohol drinking. Among total subjects, RFS was inversely associated with the risk of MCI after adjusting for covariates (Q5 vs. Q1; odds ratio [OR], 0.49; 95% confidence interval [CI], 0.28-0.83). Among total subjects and men, aMDS was inversely related to the risk of MCI after adjusting for covariates (Q5 vs. Q1; OR, 0.51; 95% CI, 0.29-0.89 for total subjects; Q5 vs. Q1; OR, 0.36; 95% CI, 0.15-0.83 for men). CONCLUSIONS: Our results demonstrate that high diet quality evaluated by RFS and aMDS is inversely associated with the risk of MCI. Thus, high quality diet may reduce or retard cognitive decline in the old population. Longitudinal studies are needed to determine the causal relationship between diet quality and the risk of MCI in the elderly.

A Technique of Applying Embedded Sensors to Intuitive Adjustment of Image Filtering Effect in Smart Phone (스마트폰에서 이미지 필터링 효과의 직관적 조정을 위한 내장센서의 적용 기법)

  • Kim, Jiyeon;Kwon, Sukmin;Jung, Jongjin
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.8
    • /
    • pp.960-967
    • /
    • 2015
  • In this paper, we propose a user interface technique based on embedded sensors applying to apps in smart phone. Especially, we implement avata generation application using image filtering technique for photo image in smart phone. In the application, The embedded sensors are used as intuitive user interface to adjust the image filtering effect for making user satisfied effect in real time after the system produced the image filtering effect for avatar. This technique provides not a simple typed method of parameter values adjustment but a new intuitively emotional adjustment method in image filtering applications. The proposed technique can use sound values from embedded mike sensor for adjusting key values of sketch filter effect if the smart phone user produces sound. Similiarly the proposed technique can use coordinate values from embedded acceleration sensor for adjusting masking values of oil painting filter effect and use brightness values from embedded light sensor for adjusting masking values of sharp filter effect. Finally, we implement image filtering application and evaluate efficiency and effectiveness for the proposed technique.

Evaluation of Performance and Service Life of Low Pressure LPG Regulators for Home Use (가정용 LP가스 저압조정기의 성능 및 수명 평가)

  • Kim Young-Gyu;Cho Seok-Beom;Kim Pil-Jong
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.23-27
    • /
    • 2006
  • This paper presents the evaluation of LPG (Liquefied petroleum gas) regulators for home use. For the evaluation, several properties of the regulators were experimentally analyzed, such as the operation of safety device, the adjusting and lock-up pressure, the adjusting spring and the diaphragm, with respect to the used time of the regulators. Experimental results showed that the initial operation performance of regulators were degraded with increase of the service time and also showed that the degradation of the performance and material property could become serious after six-year-use of the regulator.

Analysis of Flight Trajectory Characteristics of the MRBM by Adjusting the Angle of a Flight Path (비행경로각 조정에 의한 중거리 탄도미사일의 비행궤적 특성 해석)

  • Kim, Jiwon;Kwon, Yong Soo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.173-180
    • /
    • 2015
  • North Korea has developed ballistic missiles over the past 30 years. It is believed that they have a variety of ballistic missiles more than 1,000. Because these ballistic missiles threaten South Korea directly, accurate analysis of them is essential. Flight trajectories of the ballistic missiles are generally changed by means of adjusting payload weight, Isp, flight path angle, and cut-off time. The flight path angle is widely used to control the missile range. However it is difficult to predict the missile trajectory exactly in real operational environment because the missile could be launched according to its intention and purpose. This work analyzed the 1,000 km range MRBM's trajectory characteristics from adjusting flight path angle which is depressed as well as lofted method. The analysis of missile trajectory characteristics is based on the simulation of the missile trajectory model developed by KNDU research team.

A Study on the Vibration/Noise Reduction of a Gear Driving System by Adjusting the Distance between Gear Shafts (기어열의 축간거리 조절을 통한 진동/소음 저감에 대한 연구)

  • Kim, Chea-Sil;Lee, Won-Chang;Lee, Jong-Pan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.7 s.112
    • /
    • pp.697-703
    • /
    • 2006
  • This article proposes a new technique for the reduction of vibration and noise in the geared system by adjusting the distance between gear shafts. The vibration and noise may be produced by the abnormal force applied to the tooth face. And the force may be the cause of ununiform velocity in the driven shaft. If the velocity is obtained to be uniform by adjusting the distance between shafts. the vibration and noise may be reduced to some extent. In order to review, a dynamic analysis model for the gear train used in a mill turret and a test rig are developed. The velocities in the driven shaft are calculated by dynamic simulations for the model and noises in the test rig are measured with varying of the distance between shafts. The comparison of simulation and test data shows that the distance between shafts at the most uniform velocity has the lowest level of noise.

Approaches to Internal Corrosion Control Technologies by Controlling Water Quality in Water Treatment Systems (수질제어를 통한 관 내부 부식방지 기술의 정수처리공정 적용방안)

  • Seo, Dae-Keun;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.4
    • /
    • pp.509-518
    • /
    • 2006
  • Although final water of domestic water treatment plants almost contains highly corrosive characteristics, the countermeasures for eliminating internal corrosion of pipeline system have not been conducted yet by controlling water quality in plants. The technologies of internal corrosion control are to control water quality parameters(pH, Alkalinity, and Calcium Hardness etc.) and to use corrosion inhibitor. Under the conditions of domestic water treatment, first of all, the technologies of adjusting water quality parameters has to be considered. Otherwise, The technology of using corrosion inhibitor is favorably thought to be applied with the technology of adjusting water quality parameters in accordance with the result of availability for water treatment process. Since the technology of adjusting water quality parameter influences on other water treatment processes, the guideline of water quality management to be apt for water quality characteristic is required to be estabilished. While the selection of proper chemicals and technologies is dependent upon the raw water characteristics and water treatment process, typically, the technology of $Ca(OH)_2$ & $CO_2$ additions is considered more effective than other technologies in order to adjust pH and Alkalinity, increase $Ca^{2+}$ and form $CaCO_3$ film

Successful nonsurgical treatment of type II dens invaginatus with 5 root canals using a self-adjusting file: a case report

  • George Taccio de Miranda Candeiro;Antonio Sergio Teixeira de Menezes;Ana Carolina Saldanha de Oliveira;Flavio Rodrigues Ferreira Alves
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.2
    • /
    • pp.17.1-17.8
    • /
    • 2023
  • The present report describes the endodontic treatment of an Oehlers type II dens invaginatus in a maxillary lateral incisor with 5 root canals, an extremely rare condition. Apical periodontitis and related symptoms were noted. Cone-beam computed tomography was used to aid the diagnosis, reveal tooth morphology, and assist in canal location. The pulp chamber was carefully accessed, and the root canals were explored under magnification. All root canals were prepared with an R25 Reciproc Blue system and sodium hypochlorite (NaOCl) irrigation. After initial preparation, a self-adjusting file (SAF) with NaOCl and ethylenediaminetetraacetic acid was used to complement the disinfection. Additionally, calcium hydroxide medication was applied. Vertical compaction was used to fill the canals with a calcium silicate-based endodontic sealer and gutta-percha. After 12 months, the patient exhibited healing of the periapical region, absence of symptoms, and normal dental function. In conclusion, this nonsurgical treatment protocol was successful in promoting the cure of apical periodontitis. Both complementary disinfection with an SAF and use of calcium hydroxide medication should be considered when choosing the best treatment approach for dens invaginatus with very complex anatomy.