• 제목/요약/키워드: Adiabatic temperature rise

검색결과 89건 처리시간 0.022초

규불화염계 복합 조성물을 사용한 콘크리트의 수밀특성에 관한 실험적 연구 (Experimental Study on Watertightness Properties of Concrete Using Fluosilicates Based Composite)

  • 정원섭;박동수;권기주;김정우;김도수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.429-432
    • /
    • 2008
  • Large area members such as foundation concrete of underground structures in power plants have an effect on structural stability and durability of the structure due to danger of crack occurrence and shrinkage crack that occur owing to the difference of temperature by heat of hydration between inside and outside of the members at initial age. And a construction for waterproofness is performed additionally to protect marine structures from osmosis of seawater because the structures adjoin below the surface of sea. So, if a rise of the heat of hydration, crack, and corrosion of bars are controled effectively using a composite such as fluosilicate salt in concrete production process of a initial construction, expenses are cut down and construction hours are reduced by securing durability through improvement of watertightness. The property tests of adiabatic temperature by hydration are carried out at initial age about standard concrete and test concrete using a fluosilicate salt composite to evaluate an effect on improvement of watertightness for concrete structures in this study. And the experiments such as a permeability test of hardened concrete, a water absorption test, a compression strength test and a elongation test are carried out and the results from these are described.

  • PDF

굵은 입자 시멘트 및 플라이애시를 복합 사용한 콘크리트의 Mock-up Test (Mock-up Test of Concrete using Combined Coarse particle Cement and Fly-Ash)

  • 이충섭;이재윤;장덕배;김영필;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 춘계 학술논문 발표대회 학계
    • /
    • pp.87-91
    • /
    • 2009
  • This study investigates possibility for practical use through small sized test with OPC and substituted fly ash 10% and return coarse cement (RCC), classed 1100${\sim}$1200 cm2/g, which is made by Cyclone Separator at cement producing process 20% (CF) for OPC. The experimental factors are 48% of W/B and OPC and 2 kinds of concrete proportions. The target slump and air content are $150{\pm}25$ mm and $4.5{\pm}1.5$ %. For the results, the flowalility and air content of CF are less than OPC because it needs more superplasticiser and air-entraining agent. The temperature history of CF is lower than OPC about $6{\sim}10^{\circ}C$. For the strength properties, CF is less than OPC, but their gap is declined at 28 days. The strength of the specimens are ordered by standard curing, field cured specimens, and core specimens.

  • PDF

조립시멘트와 플라이애시를 조합 사용한 콘크리트의 기초적 특성 (Fundamental Properties of the Concrete Incorporating Coarse Particle Cement and Fly Ash)

  • 이충섭;장덕배;차완호;권오봉;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.553-556
    • /
    • 2008
  • 본 연구는 보통포틀랜드 시멘트(이하 OPC)의 제조공정 중 입도 분급에 의해 포집된 조립시멘트(역송분, 이하 RCC)와 저발열 혼화재료인 플라이애시(이하 FA)를 조합 치환하여 사용한 콘크리트의 기초적 특성에 대해 검토하고자 하였다. 실험은 W/B 50% 1수준에 대하여 OPC를 100% 사용한 것을Plain으로 하고, RCC를 0, 10, 20, 30%의 4수준, 혼화재로 FA를 0, 10, 20, 30%의 4수준으로 치환하여총 16배치를 계획 하였다. 실험결과로 유동성의 경우는 RCC를 치환하였을 때 증가하였으며, FA의 치환율이 증가 함에 따라 저하하는 경향을 나타냈다. 간이 단열에 의한 온도 상승량은 RCC 및 FA의치환율이 증가할수록 낮아졌고, FA를 조합하여 사용한 경우는 온도 상승을 저하시키는데 보다 효과적인 것을 알 수 있었으며, RCC30, FA30의 경우는 온도저감효과가 가장 뛰어난 것으로 나타났다. 초기강도는 RCC 및 FA의 치환율이 증가 할수록 저하하였고, 28일에서의 Plain에 대한 강도 발현율은RCC 치환율 별 FA10%에서 Plain에 비해 약 88%${\sim}$98%정도로 비교적 우수한 성능을 나타냈다.

  • PDF

조분시멘트와 플라이애시를 조합 사용한 콘크리트의 수화발열 특성 (Generation of Hydration Heat of the Concrete Combined Coarse Particle cement and Fly ash)

  • 이충섭;백대현;차완호;권오봉;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.889-892
    • /
    • 2008
  • 본 연구는 보통포틀랜드 시멘트(이하 OPC)의 제조공정 중 입도 분급에 의해 포집된 조분시멘트(이하 CC)와 저발열 혼화재료인 플라이애시(이하 FA)를 조합 치환하여 콘크리트에 미치는 수화발열특성에 대해 검토하고자 하였다. 실험은 W/B 50% 1수준에 대하여 OPC를 100% 사용한 것을 Plain 배합으로 하고, CC를 OPC에 대하여 25, 50, 75%의 3수준으로 치환하고, 혼화재로 FA를 0, 10, 20, 30, 40%의 5수준으로 치환하여 총 16배치를 계획 하였다. 실험결과로 유동성의 경우는 CC 치환율이 증가할수록 점점 감소하는 경향을 나타냈고, FA의 치환율이 증가할수록 증가하였다. CC 및 FA 치환율 별간이단열에 의한 온도 상승량은 치환율이 증가할수록 감소하였는데, 특히 FA40의 경우 CC치환율에 관계없이 최대 피크온도가 $7.3{\sim}8.9^{\circ}C$로 45%정도 아주 낮게 나타났다. 초기 압축강도는 CC 및 FA치환율 증가에 따라 비례적으로 저하하였는데, 재령경과에 따라 강도저하 폭은 감소하는 것으로 나타났다.

  • PDF

강원영동 강풍 관측설계와 예비 관측결과 (Gangwon Yeongdong Wind Experiments (G-WEX) Pilot Study: Downslope windstorms in the Taebaek Mountains, South Korea)

  • 김지은;권태영;박균명;한윤덕;신동현
    • 대기
    • /
    • 제31권4호
    • /
    • pp.361-376
    • /
    • 2021
  • "Gangwon Yeongdong Wind Experiments (G-WEX) Pilot Study: Downslope windstorms in the Taebaek Mountains, South Korea" is promoted based on joint organization by Gangwon Regional Office of Meteorology and National Institute of Meteorological Research and participation by 12 institutions to understand the mechanism in development of Yeongdong wind phenomena. The special observation (G-WEX) involved total of 5 intensive observations in March 2020 and April 2020. To collect the data necessary for the research on Yeongdong wind phenomena, (1) high-resolution surface observation network was used to examine surface wind and (2) atmospheric soundings were observed by using Rawinsonde, Wind profiler, Wind Lidar, and Drone. This study covers the detailed information on the special observational experiments for downslope windstorms in the leeward of the Taebaek Mountains, named as the Yeongdong wind, including the observational strategies, experimental designs, and pilot studies during the Intensified Observing Period (IOPs). According to 2020 G-WEX observation results, downslope windstorms were observed in 2~3 km of upper atmosphere when the strong winds happened around the top of the mountain near Daegwallyeong. Also, dry adiabatic expansion related to downslope windstorms caused temperature rise and led to formation of an inversion layer in altitude below 2.5 km. Bands of strong wind were located right under the altitude where downslope windstorms are observed with temporal rise of the temperature. As these are preliminary observation results, there needs to be continuous related researches and high-resolution weather observation.

GIS를 이용한 한반도 기온의 시·공간적 분포패턴에 관한 연구 (Research on the Spatio-temporal Distribution Pattern of Temperature Using GIS in Korea Peninsular)

  • 김남신
    • 한국지형학회지
    • /
    • 제15권2호
    • /
    • pp.85-94
    • /
    • 2008
  • 본 연구는 한반도 기온변화를 분석하여 기후대의 변화와 도시지역에서의 기온분포의 시 공간적 특성을 파악하고자 하였다. 분석에 사용된 자료는 1974년부터 2007년까지 34년간 남북의 기상관측소에서 수집된 자료를 활용하였다. 기온은 고도와 선형관계를 갖기 때문에 고도별 월별 기온단열감율을 계산하여 역거리가중법으로 500m 해상도의 분포도를 작성하였다. 도시화 지역에서의 자료는 연도별 인구변화와 기온변화를 비교 분석하였다. 기온의 연간상승율은 $0.0056^{\circ}C$로 계산되었는데, 1974년과 2107년에는 $2.14^{\circ}C$나 상승한 것으로 나타났다. 기온변화에 따라 온량지수로 구분한 기후대는 남부기후구가 90년대 이후 위도가 크게 상승하는 것으로 분석되었다. 도시지역의 평균기온상승은 80년대와 90년대에 $0.5-1.2^{\circ}C$ 상승한 것으로 분석되었다. 기온이 상승한 도시지역은 서울과 광역시 그리고 시단위 지역에서 나타났는데 이들 지역은 80년대와 90년대에 인구증가와 더불어 도시화와 산업화의 속도가 빠르게 진행된 지역이다. 북한의 경우는 평양, 안주시, 개천시, 혜산시에서도 인구증가와 더불어 기온상승 효과가 있는 것으로 나타났다. 도시의 기온상승은 식생에도 영향을 미쳐 소나무의 경우 겨울눈의 이차생장이 늦가을에 대도시의 도심부와 주변부에서 확인되고 있다. 미래의 기후변화에 대해 체계적인 접근과 대응책을 제시하기 위해서는 인덱스를 찾아 장기적인 연구가 필요하다.

경화촉진제를 사용한 프리캐스트 콘크리트의 단열온도특성 및 FEM해석에 의한 균열성능 평가에 관한 연구 (Effect of Hardening Accelerators on the Adiabatic Temperature property Properties of Precast Concrete and FEM analysis for Evaluating the Crack Performance)

  • 민태범;조인성;문영범;이한승
    • 한국건축시공학회지
    • /
    • 제15권1호
    • /
    • pp.25-33
    • /
    • 2015
  • 본 연구에서는 콘크리트 레벨에서의 프리케스트 콘크리트 개발을 목적으로 하며 수화열에 의한 균열발생을 확인하기 위해 FEM해석을 실시하여 초기균열 지수를 평가하였다. 평가결과 경화촉진제 사용량이 증가할수록 조기 압축강도가 증가하는 것으로 나타났으며 응결 시간 또한 단축되는 것을 알 수 있었다. 이는 경화촉진제에 의하여 시멘트 화합물중 $C_3A$의 반응에 의해서 응결시간이 단축되는 것으로 판단된다. 또한 단열온도 상승 시험 결과 경화촉진제의 사용량이 증가 할수록 콘크리트 중심부 온도 $80^{\circ}C$이상의 온도를 나타냈으며 경화촉진제에 의해서 최고 온도 발열시간을 단축시키는 것으로 나타났다. 이는 경화촉진제가 시멘트 수화반응을 촉진시켜 수화열을 짧은 시간에 높게 나타나는 현상으로 판단된다. 또한 높은 수화열은 균열을 발생시킬 수 있음으로 FEM 해석을 통하여 균열지수 평가를 실시하였다. FEM 해석 결과 조기에 높은 수화열이 증가하여도 균열에는 영향이 없는 예측된다. 이는 초기강도가 높기 때문에 허용응력이 증가로 인하여 인장강도가 증가하기 때문이다.

저온 소성한 MgO 분말을 함유한 플라이애시 콘크리트의 기본 물성 (Fundamental Properties of Fly ash Concrete Containing Lightly Burnt MgO Powder)

  • 최슬우;장봉석;이광명
    • 대한토목학회논문집
    • /
    • 제33권2호
    • /
    • pp.475-481
    • /
    • 2013
  • $850{\sim}1000^{\circ}C$ 정도의 저온에서 소성된 MgO 분말을 적정량 치환한 콘크리트는 장기팽창성을 갖는다. 이러한 팽창성은 저온소성한 MgO 분말의 느린 수화반응을 통해 이루어지기 때문에 장기재령까지 수축을 보상하는 특성을 가진다. 최근 수화열 저감, 내구성 향상 등의 이유와 함께 건설 산업의 탄소저감을 위한 방안으로 플라이애시 및 고로슬래그 등과 같은 혼화재의 사용이 증가하고 있다. 따라서 저온소성한 MgO 분말을 팽창재로 사용하기 위해서는 이러한 혼화재와 MgO 분말을 함께 사용한 콘크리트의 특성 규명이 필요하다. 이 연구에서는 플라이애시 콘크리트에 저온소성한 MgO 분말을 치환한 콘크리트의 슬럼프, 공기량, 수화열뿐만 아니라 장기재령 압축강도 및 길이변화 등의 기본 물성을 실험을 통해 조사하였다. 단열온도 상승시험 결과, 5% 수준으로 MgO 분말을 치환한 콘크리트의 단열온도상승속도 및 최종온도가 플라이애시 콘크리트보다 다소 작게 나타났다. 또한 압축 강도 실험결과 물-결합재비에 따라 저온소성한 MgO 분말이 장기재령 압축강도에 미치는 영향이 다르게 나타났으며, 장기적인 길이변화 실험 결과 저온소성한 MgO 분말을 치환한 콘크리트에서 큰 팽창효과를 확인할 수 있었다.

수평격판을 갖는 정사각형 밀폐공간내에서 자연대류 유동 및 열전달 (Natural Convective Flow and Heat Transfer in a Square Enclosure with a Horizontal Partition)

  • 정인기;김점수;송동주
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2304-2314
    • /
    • 1993
  • Natural convective flow and heat transfer in a two-dimensional square enclosure fitted with a horizontal partition are investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and a partition was situated perpendicularly at the one vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations were carried out with the variations of length, position and thermal conductivity of the partition, and Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). As the results, an oscillatory motion of natural convection is resulted in a sudden rise of overall heat transfer, but the increase of length of partition is significantly restrained the increase of Nusselt number. The maximum heat transfer was shown just before the transition of the direction of oscillating flow. An oscillatory motion of flow was perfectly shown the stability with the decrease of the length of partition and Rayleigh number. Also, the heat transfer was raised with the increase of the thermal conductivity in proportion to the increase of the length of partition. The stability and oscillation of flow are affected by the position of partition.

성덕 다목적댐 콘크리트의 배합설계 및 역학적 특성 (Mix Design and Physical Properties of Concrete Used in Seongdeok Multi-purpose Dam)

  • 김진근;장봉석;하재담;류종현;고석우;김정수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.517-520
    • /
    • 2008
  • 중력식 콘크리트 댐은 댐의 자중에 의해 수압 등의 외력에 저항하여 역학적인 안정을 유지하는 댐으로 크게 내부콘크리트와 외부콘크리트로 분류되어 시공된다. 성덕 다목적댐은 경북내륙지역의 안정적 용수공급 및 보현천, 길안천유역의 홍수피해 경감을 위해 경상북도 청송군에 건설 중인 댐으로, 댐길이 274m 댐높이 58.5m 총 저수용량 27.9${\times}$10$^6$ m$^3$ 규모의 중력식 다목적 댐이다. 본 댐의 분할 타설고 설정 및 수화열에 의한 온도 균열 유무 조사 등의 목적으로 상류 가물막이댐에 대한 시험시공을 실시하였다.본 연구에서는 성덕 다목적댐의 내부 및 외부콘크리트의 배합, 강도 특성 및 단열온도 등의 역학적 특성과 발열 특성을 실내실험을 통하여 확인하고, 상류 가물막이댐의 시험시공시 온도 및 응력 계측을통한 현장에서의 수화열과 온도응력 특성을 검토하였다.

  • PDF